MAURY USCG vessel records Sign in
← All vessels

INDEPENDENCE II

INDEPENDENCE II is a freight ship. The Coast Guard has recorded 80 inspections since 1995, most recently in December 2019, along with 63 deficiencies, 5 operational controls, 1 with no removal date recorded and 8 casualty investigations between 2008 and 2016.

Records from 1995 to 2019. Most recent: inspection, 4 December 2019.

Built
Not recorded
Last inspected
4 December 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

9070448 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
415666
Flag
UNITED STATES
367318000
Maury page id
psix-415666

Inspections, by type

…with no type recorded25
Years with a record 22 calendar years (1995–2019)
The 80 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it55598 - Convention (Subpart B), Gross Ton
23033 - Convention (Subpart B), Net Ton
15199 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WGAXMMSI 367318000 · active · compulsorily equipped · granted 3 February 2018, expires 4 February 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

HARRIET Towing Vessel · MISLE 56942 · 24 September 2008 · activity 3332550CAPE ROMAIN Towing Vessel · MISLE 175672 · 24 September 2008 · activity 3332550

Inspection history · 80

4 December 2019 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6866955
23 May 2019 Administrative Inspection
Administrative · Activities Europe · Activity 6691262
3 May 2019 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6676001
9 April 2019 Administrative Inspection
Administrative · Activities Europe · Activity 6658677
6 April 2019 Administrative Inspection
Administrative · Activities Europe · Activity 6656998
19 March 2019 Administrative Inspection · MSP Periodic Oversight
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6645754
6 March 2019 Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6638190
5 March 2019 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6638959
30 November 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6589923
19 October 2018 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6564551
24 September 2018 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6547341
19 September 2018 Administrative Inspection · Re-Inspection · MTSA Verification · In-Service Inspection · Annual Inspection · MSP Select Additional Oversight – Risk Assessment
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6544272
19 September 2018 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6553928
21 May 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6420219
10 May 2018 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6410728
27 February 2018 COI Inspection · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6362594
15 February 2018 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6356277
1 February 2018 MSP Select Additional Oversight – Risk Assessment
Administrative · Commandant (CG-5P-TI) · Activity 6347771
12 January 2018 MSP Periodic Oversight · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6339286
4 January 2018 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6332756
2 January 2018 MSP Periodic Oversight
Type not classified · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6331586
10 November 2017 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6317668
4 October 2017 Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Activities Europe · Activity 6280859
8 August 2017 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6234629
20 July 2017 Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6215645
1 June 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6162138
19 May 2017 MTSA/ISPS Verification · Annual Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6149496
31 March 2017 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6115155
22 February 2017 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6092843
10 February 2017 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6086076
29 December 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6155697
6 June 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5899143
3 June 2016 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 5896154
29 April 2016 Deficiency Check · Examination of Repairs · Damage Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5865381
24 April 2016 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5863032
19 April 2016 Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5857810
18 April 2016 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5856611
14 April 2016 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5854098
14 April 2016 Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5854506
13 April 2016 Annual Inspection · MTSA/ISPS Verification · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5853989
11 April 2016 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 5853063
29 February 2016 Administrative Inspection
Administrative · Activities Europe · Activity 5823654
24 February 2016 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5822597
6 February 2016 In-Service Inspection
Physical examination · Activities Europe · Activity 5812516
21 September 2015 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5726989
7 August 2015 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5208535
27 October 2014 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Activities Europe · Activity 4988972
27 October 2014 Administrative Inspection
Administrative · Activities Europe · Activity 5021869
1 October 2014 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4997281
28 August 2014 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4968034
26 March 2014 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4823532
17 May 2012 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4314065
6 August 2011 Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 4107446
2 March 2010 MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3688609
22 December 2009 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3654168
12 December 2009 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3654939
24 March 2009 MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3438992
9 January 2009 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3391222
24 September 2008 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3332550
17 March 2008 MTSA/ISPS Verification · COI Inspection · Reflagging & Initial Certification
Physical examination · Activities Europe · Activity 3166055
30 May 2007 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2946282
14 February 2007 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2872082
3 August 2006 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2734656
1 August 2006 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2732826
7 June 2006 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2673090
7 June 2006 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2673295
2 June 2006 MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2668141
29 August 2005 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2478327
14 November 2004 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2240605
10 November 2004 NPV Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2238504
29 October 2004 ISPS II Exam
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2232180
17 September 2003 Annual Inspection · Ballast Water Examination · Security Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1906523
17 September 2003 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1908049
30 January 2001 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 286616
21 January 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 273821
11 September 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 420267
12 September 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 407804
22 January 1996 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 387087
17 October 1995 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 383789
2 January 1995 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 373720

Deficiency record · 63

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 May 2019 Resolved
A main source of electrical power of sufficient capacity to supply all of those services mentioned in regulation 40.1.1 shall be provided. This main source of electrical power shall consist of at least two generating sets. Inlet casing of the turbo charger on the inboard diesel generator has developed an internal cooling water leak, and the engine should not be operated unless in an emergency. Vessel has one functional generator of the two required. Provide repair and prove proper operation to inboard generator turbo casing to the satisfaction of the attending class surveyor prior to departing the port of Antwerp. 74 SOLAS (04) II-1/Reg 41.1.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2019
Resolved 27 May 2019
Resolution: Tech made and LR verified turbo repairs. See attached reports.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 9 April 2019 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Vessel reported a failure of the ability to recover the free fall lifeboat due to a faulty winch.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2019
Resolved 11 April 2019
Resolution: Received class statement after satisfactory load test for freefall lifeboat recovery crane.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 19 March 2019 Resolved
Free fall lifeboat hand/hydraulic steering pump inoperable due to reservoir being empty. No leaks found. Engineers filled reservoir and steering was sat.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 March 2019
Resolved 19 March 2019
Resolution: Engineers filled reservoir and steering was sat.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 6 March 2019 Resolved
Rescue boat davit winch is inoperable. Make repairs to same prior to departure.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2019
Resolution: Witnessed satisfactory weight test with class present.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 6 March 2019 Resolved
Suitable handholds shall be provided or a bouyant lifeline shall be becketed around the outside of the lifeboat above the waterline and within reach of a person in the water. Marine inspector noticed several deteriorated handlines, 03 lines parted when touched.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 March 2019
Resolution: Inspectors witnessed satisfactory repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 19 September 2018 Resolved
Show proper operation of the rescue boat search light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2018
Resolved 19 October 2018
Resolution: LR attested to the proper function of the searchlight.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 19 September 2018 Resolved
Provide repairs to the port side bridge buoy release.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2018
Resolved 19 October 2018
Resolution: LR attested to the repair to the port side bridge buoy release.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 6 March 2018 Resolved
Fixed fire extinguishing systems must be maintained in a ready condition. Vessel's crew was unable to demonstrate and test the following low press CO2 systems functions and alarm: 1. Tank level alarm 2. Tank High and Low pressure alarm 3. Compressor failure alarm 4. Compressor auto-start
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 March 2018
Resolution: Attended vessel and witness functional test of all alarms associated with Low press CO2 system. All Sat
Electrical › Electric Generation Source (emergency) › Switch
Issued 6 March 2018 Resolved
Demonstrate proper operation of vessel's emergency generator low lube oil alarm and Hi-Jacket water alarm to satisfaction of attending MI.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 April 2018
Resolution: Attended vessel and witnessed satisfactory test of Emergency generators Low lube-oil alarm and High Jacket water alarm. All sat.
Engineering › Steam Boiler (propulsion) › Water Drum/Header
Issued 12 January 2018 Resolved
Provide repair proposal for holed area of lower water drum.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2018
Resolution: Repair proposal received.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 12 January 2018 Resolved
Prove proper operation of Low Pressure CO2 Extinguishing System prior to departure from port.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 January 2018
Resolution: System repaired and proper operation demonstrated.
Lifesaving › Launching Appliances › Ramp (free-fall)
Issued 4 January 2018 Resolved
Lifeboat shall be provided with an appliacne which is capable of launching and recovering the lifeboat. Launching appliance is currently unservicable, correct to satisfaction of the ACS and CG inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 15 February 2018
Resolution: Witnessed satisfactory operational test of Stern lauch hydraulic davit ram. All sat.
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 4 January 2018 Resolved
The lifeboat shall be in a state of continuous readiness so that two crew members can carry out preparations for embarkation and launching in less than 5 mins. Stow lifeboat to the satisfaction of the ACS and attending CG inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2018
Engineering › Steam Boiler (auxiliary/waste heat) › Mount
Issued 3 January 2018 Resolved
Auxillary boiler mount found wasted and leaking. Solas 74/78 (97 con.) I-11 (a)
Condition: Improper/Lack of Maintenance
Due 3 January 2018
Resolved 3 January 2018
Construction/Loadline › Penetrations › Valve Flange
Issued 3 January 2018 Resolved
Spool piece for bilge overboard line leaking at flange, condition of ship and equipment shall be maintained Solas 74/78(1997 con.) I/11(a)
Condition: Improper/Lack of Maintenance
Due 3 January 2018
Resolved 3 January 2018
Lifesaving › Lifebuoys › Stowage
Issued 3 January 2018 Resolved
Cargo ships shall carry lifebuoys complying with Reg 7.1, lifebouy found painted white Solas 74/78 (2014 con.) III/7.1
Condition: Improper/Lack of Maintenance
Due 3 January 2018
Resolved 3 January 2018
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 3 January 2018 Resolved
Cargo ships shall carry lifebuoys complying with Reg 7.1, Lifeline on lifebouy did not comply with requirements line not of synthetic material Solas 74/78 (2014 con.) III 7.12
Condition: Improper/Lack of Maintenance
Due 3 January 2018
Resolved 3 January 2018
Fire Fighting › Ventilation Systems › Ducts
Issued 3 January 2018 Resolved
Ducting Leak found inside fire locker #2, condition of ship and equipment shall be maintained Solas 74/78(1997 con.) I/11(a)
Due 2 February 2018
Resolved 12 January 2018
Resolution: Repaired as needed.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 3 January 2018 Resolved
Fire Damper #2 to bridge did not auto close, arrangements shall be made for rapid shutdown and effective closure of the vent system Solas 74/78 (1997 con.)II-2/2.2.3.4
Due 2 February 2018
Resolved 12 January 2018
Resolution: Repaired/Adjusted as required.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 3 January 2018 Resolved
VRP / SOPEP not current, no manned ship subject to this part may operate unless it carries on board a shipboard oil pollution plan 33 CFR 151.27
Condition: Invalid
Due 3 January 2018
Resolved 3 January 2018
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 3 January 2018 Resolved
If the entity who is responsible for the operations of the ship is other than the owner the owner must report the full name and details of such entity to the administration. Owner and company are different. Provide RO and USCG with current information required by ISM 3.1 Solas 74/78(2014 con.) IX // ISM 3.1
Due 2 February 2018
Resolved 12 February 2018
Resolution: Provided documentary evidence of compliance
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 3 January 2018 Resolved
The company should ensure each ship is manned with qualified, certificated and medically fit seafarers IAW national and international requirements. ARC SMS 3.01 hiring and crewing states "Tote Services" as crewing manager. How is ARC ensuring this is being done. Have RO attest to adequacy of provisions of ISM clause 6.2
Condition: Invalid
Due 2 February 2018
Resolved 12 February 2018
Resolution: Provided documentary evidence of compliance
Engineering › Steam Boiler (auxiliary/waste heat) › Mount
Issued 4 October 2017 Resolved
All boiler inspections must be complete by the end of November to include Hydro test.
Action required: 705 - Other - as specified
Due 31 December 2017
Resolved 12 January 2018
Resolution: Auxilliary Boiler exam conducted in presence of USCG & Lloyds surveyor. Exam included inspection/hydro of boiler, mounts, & stud inspection. After boiler returned to service a complete operational test of automation was conducted. All satisfactory.
Deck/Cargo › Ballast › Piping
Issued 20 July 2017 Resolved
Ballast branch line in double bottom tank #4 Center found leaking in way of piping coupling. Repairs are to be made to the satisfaction of attending Llyods Register surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 8 August 2017
Deck/Cargo › Ballast › Piping
Issued 20 July 2017 Resolved
Ballast branch line in double bottom tank #3 Stbd found heavily scaled. De-scale subject piping and make available for examination to the satisfaction of attending Llyod's Register surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2017
Resolved 8 August 2017
Resolution: BALLAST BRANCH LINE IN THE DOUBLE BOTTOM 3 STBD FOUND THINNED AT THE TOP OF THE 45 DEGREE ELBOW, TO BE MONITORED BY THE CREW AND DEALT WITH AS NECESSARY TO THE STATISFACTION OF LR SURVEYOR AT ANNUAL SURVEYS.
Deck/Cargo › Holds/Tanks › Ullage
Issued 20 July 2017 Resolved
Sounding tubes and pneumatic sounding system found fractured/wasted in the following ballast tanks" 3 upper port, 3 DB Stbd, and after peak tank. Make repairs to the satisfaction of the attending LR surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2017
Resolved 8 August 2017
Resolution: Sounding tube No3. upper port ballast tank renewed 3 meters; pneumatic sounding pip No.3 STBD double bottom ballast renewed 11 meters; sounding tube in aft peak ballast renewed 4 meters.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 20 July 2017 Resolved
The address for the owner on the COD does not match the address for the owner listed on the current CSR Document #6. Update CSR to align with COD to be provided on board to the satisfaction of USCG (Flag)
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 September 2017
Resolved 25 August 2017
Resolution: CSR corrected.
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 29 April 2016 Resolved
Main engine forward turbocharger damaged. Turbocharger secured by locking rotor. Must be corrected prior to departure from Baltimore around May 4th.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 May 2016
Resolved 6 June 2016
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 19 April 2016 Resolved
10 cm with ARPA capabilities failed. Requested for an LOD to proceed to Galveston for repairs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2016
Resolution: Recieved and accepted tech report. Report located in documents.
Engineering › Diesel Engine (propulsion-direct drive) › Distributor (fuel injection)
Issued 14 April 2016 Resolved
Vessel sustained malfunction of #8 cylinder fuel oil injection pump. vessel is to effect repairs to satisfaction of classification society.
Condition: Invalid
Due 14 April 2016
Resolved 14 April 2016
Resolution: item cleared. due to parts availability vessel allowed to preceed to Charleston and effect repairs. See def #2
Engineering › Diesel Engine (propulsion-direct drive) › Distributor (fuel injection)
Issued 14 April 2016 Resolved
Vessel suffered malfunction to #8 cylinder fuel oil injection pump. due to parts availability vessel alowed to sail to Charleston and effect repairs
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 29 April 2016
Resolution: Fuel injection pump replaced and satisfactory verified by attending Surveyor.
Engineering › Lubricating Oil Service System › Gauge
Issued 13 April 2016 Resolved
OUTBOARD MDG HAS CRACKED LUBE OIL THERMOSTAT HOUSING. INITIALLY REPORTED TO SECTOR HR DURING INBOUND NOTIFICATION. [name withheld] THE 835 TO EFFECT REPAIRS DUE TO REPLACEMENT NOT ARRIVING IN USA & CLEARING CUSTOMS IN TIME. VESSEL ALLOWED TO MAINTAIN SCHEDULE TO CHARLESTON AND REPAIR UPON RECEIPT OF PARTS. CLASS ATTENDED, CONCURRED. ISSUED CLASS CONDITION TO REPAIR NLT 4/30/16
Condition: Invalid
Due 30 April 2016
Resolved 17 April 2016
Resolution: New Manifold delivered, installed, & inspected by LR Surveyor. Report #CHL 1600045.
Electrical › Electric Generation Source (service) › Generator
Issued 11 April 2016 Resolved
Outboard main diesel generator has a crack on the lube oil thermostat housing. The main source of electrical power shall consist of at least two generator sets (74 SOLAS, 04 Con, II-1/41.1.1) . Make permanent repairs to the outboard main diesel generator to the satisfaction of the attending USCG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2016
Resolution: Cleared by class. See attached class report
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 6 February 2016 Resolved
Refit insulation in way of emergency escape in forward mid level engine room.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 February 2016
Resolved 8 February 2016
Resolution: A-60 insulation was placed as required in section by ship's crew. Inspection Sat.
Engineering › Steam System (auxiliary) › Lagging/Insulation
Issued 6 February 2016 Resolved
Replace worn and old lagging throughout engine room on various systems to include fuel piping leading to fuel injectors on main diesel engine, boiler fuel system, steam piping and in the purifier room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 March 2016
Resolved 24 March 2016
Resolution: Recieved pictures of replaced lagging abord the vessel.
Lifesaving › Launching Appliances › Davit
Issued 6 February 2016 Resolved
Mark the port liferaft davit to clearly reflect it has been decommissioned and is not to be used to lower liferafts.
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 8 February 2016
Resolution: Crew stenciled the davit with a contrasting color as specified.
Accommodation/Occupational Safety › Potable Water System › General
Issued 6 February 2016 Resolved
Make permanent repairs for three soft patches found on potable water line directly above the OWS in the engine room.
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 8 February 2016
Resolution: Removed damaged piping from flange to flange and installed new pipe
Engineering › Steam System (main) › Valve
Issued 6 February 2016 Resolved
Repair all steam leaks in engine room found on steam lines.
Due 8 March 2016
Resolved 8 February 2016
Resolution: Crew conducted maintenance on the valves that were leaking which corected the leaks.
Engineering › Lubricating Oil Service System › Hose
Issued 6 February 2016 Resolved
Replace worn armored hose for the supply to the # 2 generator lube oil purifier.
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 8 February 2016
Resolution: Crew replaced worn hose, deficiency cleared.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 6 February 2016 Resolved
Demonstrate proper operation of all emergencylighting for liferaft embarkation stations.
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 7 February 2016
Resolution: Vessel replaced several cables, fixtures. Witnessed satisfactory operation of lights.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 6 February 2016 Resolved
Demonstrate proper operation of self-closing fire doors
Due 8 March 2016
Resolved 7 February 2016
Resolution: Crew conducted maintenance on the fire doors. Witnessed satisfactory closing of fire doors
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 6 February 2016 Resolved
Smoke detector in aft steering was found to be broken off mounting. Re-moount smoke detector as required.
Due 8 March 2016
Resolved 8 February 2016
Resolution: Crew repaired bracket and re-mounted
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 February 2016 Resolved
Panel for steering gear electrical feed was found with access to the inside through penetrations. Ensure no access to the inside of the panel unless panel opened by design.
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 8 February 2016
Resolution: Crew fixed penetrations, all sat.
Electrical › Electrical Distribution System (emergency) › Panelboard
Issued 6 February 2016 Resolved
Controller panel in AC room for the old rescue boat was found to allow acces to live electrical wiring from outside the panel while closed. Ensure there is no access to live electrical wiring.
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 7 February 2016
Resolution: Crew blanked off front of AC controller with a metal plate preventing access to the electrical wiring inside the panel.
Construction/Loadline › Hull › Side Shell
Issued 27 October 2014 Resolved
Sharp indention on starboard stern quarter on side shell iwo frame 21.
Action required: 705 - Other - as specified
Due 27 November 2014
Resolved 12 November 2014
Resolution: Received class report attesting to repairs.
Construction/Loadline › Structures › Door
Issued 27 October 2014 Resolved
Verify operation of watertight and weather tight doors
Action required: 705 - Other - as specified
Due 27 November 2014
Resolved 12 November 2014
Resolution: Received class report attesting to repairs.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 27 October 2014 Resolved
Make permanent repairs to overhead iwo of forward bulkhead near the hatch on deck 13.
Action required: 705 - Other - as specified
Due 27 November 2014
Resolved 12 November 2014
Resolution: Received class report attesting to repairs.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 27 October 2014 Resolved
Make permanent repairs to both aft corners of superstructure on deck 14. Areas show visible signs of water intrusion.
Action required: 705 - Other - as specified
Due 27 November 2014
Resolved 12 November 2014
Resolution: Received class report attesting to repairs.
Construction/Loadline › Hull › Stringer
Issued 27 October 2014 Resolved
Make permanent repairs to crack noted by previous CG inspection iwo fwd entrance to #3 port side wing tank.
Action required: 705 - Other - as specified
Due 27 November 2014
Resolved 12 November 2014
Resolution: Received class report attesting to repairs.
Construction/Loadline › Structures › Door
Issued 27 October 2014 Resolved
Verify wastage on upper deck natural ventilation covers is within acceptable class specifications. Replace gaskets or make repairs to prevent continued water intrusion.
Action required: 705 - Other - as specified
Due 27 November 2014
Resolved 12 November 2014
Resolution: Received class report attesting to repairs.
Fire Fighting › Ventilation Systems › Exhaust Ducts (Galley Ranges)
Issued 27 October 2014 Resolved
PMS and replace gasket on galley fire damper to ensure proper operation.
Action required: 705 - Other - as specified
Due 27 November 2014
Resolved 12 November 2014
Resolution: Received class report attesting to repairs.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 27 October 2014 Resolved
PMS fire damper and replace missing fire damper handle.
Action required: 705 - Other - as specified
Due 27 November 2014
Resolved 12 November 2014
Resolution: Received class report attesting to repairs.
Deck/Cargo › Mooring/Anchoring › Capstan
Issued 27 October 2014 Resolved
Demonstrate proper operation of both anchors.
Action required: 705 - Other - as specified
Due 27 November 2014
Resolved 12 November 2014
Resolution: Received class report attesting to repairs.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 27 October 2014 Resolved
Replace winch brakes and demonstrate proper operation on both mooring winches.
Action required: 705 - Other - as specified
Due 27 November 2014
Resolved 12 November 2014
Resolution: Received class report attesting to repairs.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 24 March 2009 Resolved
Demonstrate proper operation of the rudder repeatback system, indicates two to three degrees off as the rudder moves toward the greater angles.
Action required: 705 - Other - as specified
Due 26 August 2009
Resolved 2 July 2009
Resolution: new repeater card installed and operational test satisfactory.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 24 March 2009 Resolved
Vessel to post permanent operating instructions at all operating stations for the LPCO2. Provide CG with Unitor tech report. 30 second time delay has been removed at some time prior to reflag. Gap analysis states system in complience, but does not mention any modification, class to provide clarification.
Action required: 705 - Other - as specified
Due 24 April 2009
Resolved 22 April 2009
Resolution: new 30 sec. TD bottle installed and tested, sat.
Navigation › Collision/Grounding Avoidance › Radar Plotting Facilities
Issued 9 January 2009 Resolved
Vessel has an inoperable Voyage Data Recorder (VDR) as reported by the Captain. Prior to sailing Foreign the VDR must be working properly as demonstrated to class. SOLAS 2004 / Chapter V, Regulation 20.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 February 2009
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 7 June 2006 Resolved
Vessel did not submit a proper notice of arrival for the Port of Brunswick. Vessel was expelled from port until proper NOA is submitted.
Action required: 705 - Other - as specified
Due 7 June 2006
Resolved 8 June 2006
Resolution: Vessel allowd to enter port after submission of proper ENOA.
Construction/Loadline › Hull › Side Shell
Issued 2 June 2006 Resolved
A 15 ft long inset located approx. 10 ft above the waterline in the vicinity of frames 30-40 starboard side. This damage resulted in approx. 10-12 bent frames in the engine room. In addition a 2 ft by 6 inch inset at frame 26 discovered. Causes unknown. Vessel shall have class survey damages and provide report attesting to structural integrity of the affected areas.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 October 2006
Resolved 3 August 2006
Resolution: recieved class report from agent via fax attesting to hull survey.
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 29 August 2005 Resolved
Document found to be expired in MISLE.
Due 30 August 2005
Resolved 29 August 2005
Resolution: Updated documents that was received via fax into MISLE.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 17 September 2003 Resolved
Battery Power insufficient
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 September 2003
Resolved 18 September 2003
Resolution: Class report received stating that two new batteries were install and emergency generator now operates properly.
Electrical
Issued 21 January 2000 Resolved
EMERGENCY GENERATOR FUEL TANK 1/2 FULL, NOT READY FOR IMMEDIATE USE. TANK FILLED WHILE ON BOARD. ITEM CLEARED BY NYCMI
Condition: Unknown
Due 24 January 2000
Resolved 24 January 2000
Lifesaving
Issued 21 January 2000 Resolved
LIFERAFT HYDRO STATIC RELEASE NOT INSTALLED CORRECTLY ON TWO (2) LIFERAFTS.CORRECTED ON BOARD. ITEM NY02 CLEARED BY NYCMI.
Condition: Unknown
Due 24 January 2000
Resolved 24 January 2000

Casualty record · 8

24 September 2008Routine · role: Involved in a Marine Casualty · activity 3332550
22 August 2010Routine · role: Involved in a Marine Casualty · activity 3831769
6 August 2011Routine · role: Involved in a Marine Casualty · activity 4107446
28 October 2011Routine · role: Involved in a Marine Casualty · activity 4179267
14 November 2011Routine · role: Involved in a Marine Casualty · activity 4188871
14 April 2016Routine · role: Involved in a Marine Casualty · activity 5854098
24 April 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 5863032
29 December 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6155697
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.