MAURY USCG vessel records Sign in
← All vessels

SHI DAI 6

SHI DAI 6 is a 1994 freight ship. The Coast Guard has recorded 23 inspections since 1995, most recently in November 2010, along with 15 deficiencies and 2 operational controls.

Records from 1995 to 2010. Most recent: inspection, 22 November 2010.

Built
1994
Last inspected
22 November 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9115224 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
415674
Flag
CHINA
—
Maury page id
psix-415674

Inspections, by type

…with no type recorded13
Years with a record 13 calendar years (1995–2010)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it35879 - Convention (Subpart B), Gross Ton
23407 - Convention (Subpart B), Net Ton
69180 - Dead Weight, Ton
78854 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 23

22 November 2010 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3896672
19 November 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3894910
19 November 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3898262
29 July 2009 Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · MARPOL Annex VI Survey · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3541349
18 August 2006 ISPS II Exam · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2751912
17 February 2006 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2588022
3 August 2005 PII Safety Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2450059
27 May 2005 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2370055
30 December 2004 ISPS II Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2266452
30 December 2004 PII Safety Exam · Ballast Water Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2266454
16 October 2003 MARPOL Annex I Examination · Annual Inspection · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1928401
14 October 2003 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1929077
5 November 2002 Deficiency Check · Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1701816
8 May 2002 Re-Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1614675
6 May 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1614797
21 February 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 287513
29 August 2000 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 281536
31 August 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 432760
24 March 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 426887
20 November 1997 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 410110
1 July 1996 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 392673
18 January 1996 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 386824
5 January 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 373992

Deficiency record · 15

Construction/Loadline › Hull › Bottom Plating
Issued 22 November 2010 Resolved
The vessel experienced a grounding while in the Mississippi River.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 November 2010
Resolved 22 November 2010
Resolution: Received, reviewed and accepted class report from CCS stating the hull was repaired, tested and found satisfactory.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 29 July 2009 Resolved
1499- A SOFT PATCH WAS NOTED ON THE MAIN ENGINE JACKET WATER HEAT EXCHANGER PIPING. MAKE PERMANENT REPAIRS TO THE SATISFACTION OF CLASS. SOLAS I/11
Action required: 705 - Other - as specified
Due 12 August 2009
Resolved 19 October 2009
Resolution: Received class report from [name withheld] Satisfying the requirement.
Engineering › Feedwater/Condensate Water System › Piping
Issued 29 July 2009 Resolved
1499- THE FEEDWATER CONDENSATE HEAT EXCHANGER TANK HAS A TEMPORARY REPAIR. MAKE PERMANENT REPAIRS TO THE SATISFACTION OF CLASS SOCIETY. SOLASI/11
Action required: 705 - Other - as specified
Due 12 August 2009
Resolved 19 October 2009
Resolution: Received class report from [name withheld] Satisfying the requirement.
Lifesaving › Launching Appliances
Issued 5 November 2002 Resolved
Limit switch for port side lifeboat inoperable.
Action required: 705 - Other - as specified
Due 5 November 2002
Resolved 5 November 2002
Resolution: New limit switch installed and tested satisfactorily.
Pollution Prevention/Response › Prevention Equipment
Issued 5 November 2002 Resolved
OWS Unit is malfunctioning, and alarm sounds at various PPM and requires thorough calibration. Do not operate in U.S. waters until proper operation is proven. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 705 - Other - as specified
Due 10 November 2002
Resolved 16 October 2003
Resolution: Proper operation of the OWS was observed.
Engineering › Steering Gear System
Issued 8 May 2002 Resolved
No. 2 steering pump seal is leaking at a rate of 70-80 drops per minute. LEGACY COMPONENT DESC: Pump
Action required: 15 - Rectify deficiencies by next port
Due 16 May 2002
Resolved 5 November 2002
Resolution: Steering pump seal has been repaired satisfactorily.
Navigation
Issued 21 February 2001 Resolved
Crew members unable to perform satisfactory steering tests._x001C_ Perform satisfactory steering test prior to departure.
Condition: Unknown
Due 24 February 2001
Resolved 6 March 2001
Fire Fighting
Issued 21 February 2001 Resolved
SCBA bottles and spares had insufficient air to perform drills._x001C_ Provide SCBA bottles and spares with the required amount of air.
Condition: Unknown
Due 24 February 2001
Resolved 6 March 2001
Fire Fighting
Issued 21 February 2001 Resolved
Crew members unable to perform satisfactory fire drill._x001C_ Perform satisfactory fire drill prior to departure.
Condition: Unknown
Due 24 February 2001
Resolved 6 March 2001
Fire Fighting
Issued 21 February 2001 Resolved
Command provided no control or instructions for crew during fire drill._x001C_
Condition: Unknown
Due 24 February 2001
Resolved 6 March 2001
Fire Fighting
Issued 21 February 2001 Resolved
Crew members did not dress out properly._x001C_ Perform proper dressing procedures prior to departure.
Condition: Unknown
Due 24 February 2001
Resolved 6 March 2001
Lifesaving
Issued 29 August 2000 Resolved
VESSEL LIFERAFTS ARE BEING SERVICED AND ARE PRESENTLY INCORRECTLY CONNECTEDFOR HYDROSTATIC RELEASE. VESSEL REQUIRED TO PROVIDE SERVICING REPORT FROM LIFERAFT FACILITY PRIOR TO DEPARTURE FROM JACMS 30AUG00.
Condition: Unknown
Due 30 August 2000
Resolved 5 September 2000
Lifesaving
Issued 24 March 1999 Resolved
LIFE RAFT OPERATING INSTRUCTIONS WERE NOT CORRECT FOR THE TYPE OF LIFE RAFTTHE SHIP IS EQUIPED WITH. VESSEL MUST PROVIDE CORRECT MOUNTED INSTRUCTIONS PRIOR TO ENTRY INTO NEXT US PORT_x001C_
Condition: Unknown
Due 13 September 1999
Resolved 13 September 1999
Navigation
Issued 20 November 1997 Resolved
SHIPS GYRO COMPASS WAS INOPERATIVE DURING THE INSPECTION. REPAIR AND PROVIDE TECHNICIANS REPORT OF REPAIRS PRIOR TO DEPARTURE.
Condition: Unknown
Due 21 November 1997
Resolved 20 November 1997
Lifesaving
Issued 5 January 1995 Resolved
Vessel stored paints and thinners in the forward bosun hold, which was not a suitable location for these products.
Condition: Unknown
Due 6 January 1995
Resolved 6 January 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.