Records from 2004 to 2008. Most recent: inspection, 11 September 2008.
Inspection history · 37
11 September 2008
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3322704
24 June 2008
MARPOL Annex I Examination · Random ISPS/MTSA/PSC · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3246124
15 February 2008
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3147987
29 January 2008
Ballast Water Examination · PII Safety Exam · ISPS III Exam · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3138094
27 June 2007
Ballast Water Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2975434
22 August 2006
NPV Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2756134
8 June 2006
Random ISPS/MTSA/PSC
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2673676
7 June 2006
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2673371
27 March 2006
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2610468
23 March 2006
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2608378
5 January 2006
Random ISPS/MTSA/PSC
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2561135
5 January 2006
Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 2561880
4 January 2006
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2560184
3 January 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2560059
19 October 2005
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2517675
18 October 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2516804
24 August 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2473354
4 August 2005
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2452207
2 August 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2448445
2 August 2005
ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2448501
2 August 2005
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2448632
2 August 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2450876
2 August 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2475126
17 May 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2359905
17 May 2005
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2360149
4 March 2005
NPV Safety Exam · Ballast Water Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2303747
3 March 2005
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2302592
18 December 2004
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2261796
15 December 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2259699
1 October 2004
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2211157
17 July 2004
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2136004
13 July 2004
ISPS II Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2131322
13 July 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2131610
23 February 2004
Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2011282
15 February 2004
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2007062
12 February 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2005745
11 February 2004
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2005148
Engineering › Fuel Oil Service System › Piping
Issued 24 June 2008
Resolved
Heat exchangers in fuel oil purifying space located on outboard bulkhead were found with fuel oil soaked lagging, and fuel oil supply solenoid valves on boiler were also found with fuel oil all over them, vessel is to clean areas and identify source of fuel oil and make permanent repairs to satisfaction of class society.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 July 2008
Resolved 11 September 2008
Resolution: Received class report class cleared all defs.
Engineering › Thrusters › Piping
Issued 24 June 2008
Resolved
Hydraulic tank supply line from hydraulic tank in foscle stores appears to be leaking on deck of entrance to burma passage, vessel to identify source of hydraulic oil on deck and make permanent repairs to satisfaction of classification society.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 July 2008
Resolved 11 September 2008
Resolution: Received class report. Class has cleared all outstanding deficiencies.
Engineering › Feedwater/Condensate Water System › Piping
Issued 29 January 2008
Resolved
Vessel's Filter Condensation Tank (Hot Well) has a bypass line with a cement patch and a steam line with a small hole. Make permanent repairs within 30 days to the satisfaction of Class.
Action required: 705 - Other - as specified
Due 29 February 2008
Resolved 15 February 2008
Resolution: Received LR Class report on 14FEB08 that repairs were examined and found to the satisfaction of the attending surveyor. Deficiency cleared.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 29 January 2008
Resolved
Steam coil line, in the vicinity of thermo switches for Fuel Oil purifiers, is leaking water condensation at the rate of approximately 1 drip-per-second, and has a hole in the line which is letting out steam. Make permanent repairs within 30 days to the satisfaction of Class.
Action required: 705 - Other - as specified
Due 29 February 2008
Resolved 15 February 2008
Resolution: Received LR Class report on 14FEB08 that repairs were examined and found to the satisfaction of the attending surveyor. Deficiency cleared.
Engineering › Steam Boiler (auxiliary/waste heat) › Valve, Relief
Issued 29 January 2008
Resolved
Steam heating line for boiler near the regulating valve has a pencil-hole leak, letting out water. Chief Engineer and Fitter have made temporary repairs to the line. Make permanent repairs within 30 days to the satisfaction of Class.
Action required: 705 - Other - as specified
Due 29 February 2008
Resolved 15 February 2008
Resolution: Received LR Class report on 14FEB08 that repairs were examined and found to the satisfaction of the attending surveyor. Deficiency cleared.
Engineering › Generator (propulsion-electric) › Wiring
Issued 29 January 2008
Resolved
In emergency generator space, a box has been installed for radio telephone communications. The box has three wires for connecting the portable radiotelephone, two of which have black electric tape on the ends, which are not properly secured, with the possibility of electric shock hazard. Find a better means of isolating wires or connecting a permanent phone in the space within 30 days to Class.
Action required: 705 - Other - as specified
Due 29 February 2008
Resolved 15 February 2008
Resolution: Received LR Class report on 14FEB08 that repairs were examined and found to the satisfaction of the attending surveyor. Deficiency cleared.
Lifesaving › Lifejacket/PFD (General)
Issued 11 February 2004
Resolved
There was an insufficient number of life jackets at remote survival craft location forward. Must provide two additional life jackets forward to bring total number of jackets to six. LEGACY COMPONENT DESC: Quantity
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 11 February 2004
Resolution: Crew put two additional life jackets forward at the remote survival craft location.
Operations/Management › Pollution
Issued 11 February 2004
Resolved
Alarm sounds and pump secures but the oily water separator three way valve does not operate when monitoring equipment detects greater than 15ppm. Must make proper repairs. LEGACY COMPONENT DESC: Retention of Oily Mixture
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 11 February 2004
Resolution: Crew made proper repairs to oily water separator.
Fire Fighting › Means of Escape
Issued 11 February 2004
Resolved
Three of five doors to the emergency escape trunks from the engine room do not self close. Perform maintenace/ repairs so doors close properly. LEGACY COMPONENT DESC: Doorways
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 11 February 2004
Resolution: Crew performed proper maintenance to doors so they now work properly.