MAURY USCG vessel records Sign in
← All vessels

LAINE

LAINE is a 1985 freight ship. The Coast Guard has recorded 37 inspections since 1995, most recently in March 2005, along with 53 deficiencies and 8 operational controls.

Records from 1995 to 2005. Most recent: inspection, 28 March 2005.

Built
1985
Last inspected
28 March 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8314615 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
415955
Flag
PANAMA
—
Maury page id
psix-415955

Inspections, by type

…with no type recorded31
Years with a record 10 calendar years (1995–2005)
The 37 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it15893 - Convention (Subpart B), Gross Ton
8126 - Convention (Subpart B), Net Ton
17850 - Dead Weight, Ton
26770 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 37

28 March 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2323993
25 March 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2320023
22 March 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2317883
12 March 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2308794
11 March 2005 PII Safety Exam · Administrative Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2308247
4 November 2004 NPV Safety Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2235045
31 July 2004 Ballast Water Examination · ISPS II Exam · NPV Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2150339
30 July 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2150871
28 July 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2148456
15 April 2004 Re-Inspection · Deficiency Check · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2044742
7 April 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2044777
21 March 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2028647
20 March 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2027863
21 December 2003 Damage Survey
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1969191
16 July 2003 Annual Inspection · Ballast Water Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1848719
6 December 2001 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 296143
26 November 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 295791
14 July 2001 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 511547
11 June 2001 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 290849
28 January 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 55925
16 January 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 285986
16 June 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 278900
8 June 2000 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 278584
17 January 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 273779
17 May 1999 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 34555
17 May 1999 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 428773
7 May 1999 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 428411
21 May 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 416158
17 May 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 416066
29 December 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 411180
10 December 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 410631
29 May 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 391675
29 May 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 645352
14 March 1996 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 388723
28 February 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 388257
19 October 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 383855
10 March 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 376073

Deficiency record · 53

Electrical › Electrical Distribution System (service) › Ground Detection
Issued 4 November 2004 Resolved
Low insulation monitoring device for the primary electrical distribution system (380V) is inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 March 2005
Resolution: Survey report from RMS stated the device was repaired by crew. Audible and visual indication of abnormally low insulation valves was provided. Tested in operation, found fit.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 4 November 2004 Resolved
Main switchboard in engine room is missing several glass guards. Access panels to electrical boxes all around the machinery spaces have left open.
Action required: 705 - Other - as specified
Due 11 November 2004
Resolved 11 March 2005
Resolution: Report from RMS stated: Five glass guards were fabricated and installed in the main switchboard by crew. All access panels were closed on 05 Nov 04 and found fit.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 4 November 2004 Resolved
The Class-A opening self closing device for the engine room is inoperable.
Action required: 705 - Other - as specified
Due 11 November 2004
Resolved 11 March 2005
Resolution: Report from RMS stated: Repaired by the crew, tested in operation and found fit. All other closing devices for doors of the Class A (according to Fire Plan) were tested in operation on 05 Nov 04 and found fit.
Engineering › Generator (propulsion-electric)
Issued 15 April 2004 Resolved
The No. 4 generator's No. 2 cylinder has a notable F/O leak. LEGACY COMPONENT DESC: Cylinder
Action required: 705 - Other - as specified
Due 29 April 2004
Resolved 20 April 2004
Resolution: Received class report from [name withheld] stating outstanding deficiency has been rectified.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 15 April 2004 Resolved
The No. 3 generator's No.2 and No. 3 cylinders have notable F/O leaks. LEGACY COMPONENT DESC: Cylinders
Action required: 705 - Other - as specified
Due 29 April 2004
Resolved 20 April 2004
Resolution: Received class report from [name withheld] stating outstanding deficiency has been rectified.
Pollution Prevention/Response › Prevention Equipment
Issued 15 April 2004 Resolved
The piping from the OWS to the sludge tank has numerous temporary band patches. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 705 - Other - as specified
Due 29 April 2004
Resolved 20 April 2004
Resolution: Received class report from [name withheld] stating outstanding deficiency has been rectified.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 15 April 2004 Resolved
The F/O day tank sight glass for the main engine has a notable leak. LEGACY COMPONENT DESC: Day tank
Action required: 705 - Other - as specified
Due 29 April 2004
Resolved 20 April 2004
Resolution: Received class report from [name withheld] stating outstanding deficiency has been rectified.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 15 April 2004 Resolved
The machinery spaces, containments, and bilge areas have excessive amounts of oil. Empty all containments and make the machinery and bilge spaces oil free.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2004
Resolved 20 April 2004
Resolution: Received class report from [name withheld] stating outstanding deficiency has been rectified.
Navigation › Piloting/Steering
Issued 21 March 2004 Resolved
This is a carry over discrepancy from activity #2027863. Gyrocompass inoperative. LEGACY COMPONENT DESC: Gyro Compass
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 April 2004
Resolved 16 April 2004
Resolution: Rcvd report from Sperry Marine stating that gyrocompass was repaired and working normal.
Navigation › Piloting/Steering
Issued 20 March 2004 Resolved
Make proper repairs to the Gyrocompass. LEGACY COMPONENT DESC: Gyro Compass
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2004
Resolution: Forwarded to activity #2028647.
Fire Fighting › Fire Pumps
Issued 16 July 2003 Resolved
MOTOR FOR THE #1 FIREPUMP IS INOPERABLE REPAIR TO THE SATISFACTION OF CLASS PRIOR TO DEPARTURE. VSL WAS CLEARED TO LEAVE THE PORT OF SAVANNAH TO TRANSIT TO TAMPA. CLASS REPORT BY BV STATES THAT VESSEL IS ABLE TO USE BALLEST PUMP AS AUX FIRE PUMP. VSL MADE ARANGEMENTS FOR REPAIRS IN TAMPA. LEGACY COMPONENT DESC: Power Source
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 July 2003
Resolved 4 August 2003
Resolution: Received a class report from Bureau Veritas #MIAO/2003/J0497. The report states that the fire pump has been replaced a nd tested satisfactory.
Lifesaving
Issued 11 June 2001 Resolved
Safety lines for lifeboat rotten.
Condition: Unknown
Due 11 June 2001
Resolved 15 June 2001
Lifesaving
Issued 11 June 2001 Resolved
Aft davit block & tackle wasted.
Condition: Unknown
Due 11 June 2001
Resolved 15 June 2001
Lifesaving
Issued 11 June 2001 Resolved
Helm cover hinge wasted and latching devices missing.
Condition: Unknown
Due 11 June 2001
Resolved 15 June 2001
Lifesaving
Issued 11 June 2001 Resolved
Return fuel line cracked at tank (stbd side fitting).
Condition: Unknown
Due 11 June 2001
Resolved 15 June 2001
Lifesaving
Issued 11 June 2001 Resolved
Forward sea painter missing. Replace and attach like BA09.
Condition: Unknown
Due 11 June 2001
Resolved 15 June 2001
Lifesaving
Issued 11 June 2001 Resolved
Access doors for lifeboat handles wasted.
Condition: Unknown
Due 11 July 2001
Resolved 15 June 2001
Lifesaving
Issued 11 June 2001 Resolved
Forward davit arm stop cylinder wasted.
Condition: Unknown
Due 11 June 2001
Resolved 15 June 2001
Lifesaving
Issued 11 June 2001 Resolved
Safety limit switch mounts wasted-forward and aft.
Condition: Unknown
Due 11 June 2001
Resolved 15 June 2001
Lifesaving
Issued 11 June 2001 Resolved
Return fuel line craked at tank fitting (stbd side of tank) on port lifeboat.
Condition: Unknown
Due 11 June 2001
Resolved 15 June 2001
Lifesaving
Issued 11 June 2001 Resolved
Helm cover missing latching devices.
Condition: Unknown
Due 11 June 2001
Resolved 15 June 2001
Lifesaving
Issued 11 June 2001 Resolved
Forward sea painter is made fast to the boat, not immediately ready for release.
Condition: Unknown
Due 11 June 2001
Resolved 15 June 2001
Lifesaving
Issued 11 June 2001 Resolved
Prop wasted where blades meet hub.
Condition: Unknown
Due 11 June 2001
Resolved 15 June 2001
Lifesaving
Issued 11 June 2001 Resolved
Access doors to lifeboat handles wasted.
Condition: Unknown
Due 11 July 2001
Resolved 15 June 2001
Lifesaving
Issued 11 June 2001 Resolved
Condition of Class-Renew all davit blocks by 13Aug2001.
Condition: Unknown
Due 30 November 2001
Resolved 30 November 2001
Lifesaving
Issued 11 June 2001 Resolved
Lifeboat not able to free fall (had to operate electric wrench to lower- maintenance on falls required.)
Condition: Unknown
Due 11 June 2001
Resolved 15 June 2001
Lifesaving
Issued 11 June 2001 Resolved
Forward davit arm, forward sheave wasted.
Condition: Unknown
Due 11 June 2001
Resolved 15 June 2001
Documentation
Issued 11 June 2001 Resolved
Have agent fax a copy of Safety Equipment Certificate to USCG @ 410-576- 2655.
Condition: Unknown
Due 11 June 2001
Resolved 12 June 2001
Documentation
Issued 8 June 2000 Resolved
Vessel's Class Society Surveyor to attend and attest to the validity of theCargo Ship Safety Equipment Certificate with regard to the Fire Safety Plan.
Condition: Unknown
Due 9 June 2000
Resolved 13 June 2000
Construction/Loadline
Issued 8 June 2000 Resolved
Vessel's class society surveyor to attend and attest to the proper operation of the OWS, including proper operation of alarms and calibration.
Condition: Unknown
Due 9 June 2000
Resolved 13 June 2000
Lifesaving
Issued 8 June 2000 Resolved
Provide the proper quantity of rations in the port and starboard lifeboats.
Condition: Unknown
Due 9 June 2000
Resolved 13 June 2000
Lifesaving
Issued 8 June 2000 Resolved
Vessel's class society to attend vessel and attest to the condition and proper size of the wire rope falls port and starboard.
Condition: Unknown
Due 9 June 2000
Resolved 13 June 2000
Fire Fighting
Issued 8 June 2000 Resolved
Renew as original, the missing fire hose and nozzle located on the starboard main deck forward. Also, renew the holed fire hose located on the bow.
Condition: Unknown
Due 9 June 2000
Resolved 13 June 2000
Electrical
Issued 8 June 2000 Resolved
Vessel's class society surveyor to attend vessel and attest to the proper installation of he 380V electrical cable located port side forward under forecastle.
Condition: Unknown
Due 9 June 2000
Resolved 13 June 2000
Accommodation/Occupational Safety
Issued 10 December 1997 Resolved
REPAIR MARINE SANITATION DEVICE PRIOR TO NEXT US PORT.
Condition: Unknown
Due 31 January 1998
Resolved 19 May 1998
Electrical
Issued 10 December 1997 Resolved
REPAIR LIGHT IN CO2 STAIRWELL PRIOR TO NEXT US PORT.
Condition: Unknown
Due 29 December 1997
Resolved 29 December 1997
Electrical
Issued 10 December 1997 Resolved
REMOVE UNUSED WIRES ON FORECASTLE PRIOR TO NEXT US PORT.
Condition: Unknown
Due 29 December 1997
Resolved 29 December 1997
Fire Fighting
Issued 29 May 1996 Resolved
Renew as original deteriorated sea water pipe from #1 fire pump located engine room lower level port side
Condition: Unknown
Due 6 June 1996
Resolved 7 June 1996
Fire Fighting
Issued 29 May 1996 Resolved
Prove satisfactory operation of the #1 and #2 main fire pumps to the satisfaction of the attending U.S. Coast Guard marine inspector.
Condition: Unknown
Due 6 June 1996
Resolved 7 June 1996
Electrical
Issued 29 May 1996 Resolved
Renew as original deteriorated sea water cooling pipe to #2 main generator
Condition: Unknown
Due 6 June 1996
Resolved 7 June 1996
Engineering
Issued 29 May 1996 Resolved
Renew as original deteriorated sea water supply pipe to refrigeration system located engine room lower level stbd side
Condition: Unknown
Due 6 June 1996
Resolved 7 June 1996
Engineering
Issued 29 May 1996 Resolved
Renew as original deteriorated sea water cooling supply pipe for main engine located room 2nd level fwd centerline
Condition: Unknown
Due 6 June 1996
Resolved 7 June 1996
Engineering
Issued 29 May 1996 Resolved
Renew as original deteriorated sea water pipe in way of #2 fire pump located engine room lower level stbd side.
Condition: Unknown
Due 6 June 1996
Resolved 7 June 1996
Navigation
Issued 29 May 1996 Resolved
Repair and prove operation of echo depth sounding recorder
Condition: Unknown
Due 6 June 1996
Resolved 7 June 1996
Deck/Cargo
Issued 29 May 1996 Resolved
Remove excess oil and oil residue from all containments in the engine room,the seperator room, generator flats, from the main engine and area immediately aft of the main engine. Sludge tank is to have 50% capacity remaining prior to sailing.
Condition: Unknown
Due 6 June 1996
Resolved 7 June 1996
Engineering
Issued 29 May 1996 Resolved
Renew as original deteriorated sea water cooling supply pipe to #3 main generator
Condition: Unknown
Due 6 June 1996
Resolved 7 June 1996
Engineering
Issued 29 May 1996 Resolved
Renew as original deteriorated sea water cooling supply pipe to #1 main generator. (2 pipes)
Condition: Unknown
Due 6 June 1996
Resolved 7 June 1996
Fire Fighting
Issued 14 March 1996 Resolved
MOST OF VSL'S PORTABLE CO2 & SOME OF ITS FOAM PORTABLE FIRE EXTINGUISHERS_x001C_ HAVE WASTED HOSES WERE THE HOSE MEETS THE CYLINDER. SOLAS 74 II-2
Condition: Unknown
Due 20 March 1996
Resolved 20 March 1996
Fire Fighting
Issued 14 March 1996 Resolved
ALL FIREMANS OUTFITS (4) WERE KEPT IN ONE LOCATION. AS PER SOLAS 74_x001C_ II-2/17 4 OUTFITS SHALL BE STORED IN WIDELY SEPARATED LOCATIONS.
Condition: Unknown
Due 20 March 1996
Resolved 20 March 1996
Lifesaving
Issued 14 March 1996 Resolved
ALL VSL'S LIFEBUOYS AND BOTH LIFEBOATS NEED THIER EXISTING RETROREFLECTIVE TAPE REPLACED. ALSO ALL LIFEBUOYS NEED REPAINTING. SOLAS 74 III/30 2.6 AND 2.7
Condition: Unknown
Due 20 March 1996
Resolved 20 March 1996
Accommodation/Occupational Safety
Issued 14 March 1996 Resolved
VSL'S TYPE II MSD INOPERABLE. VSL CURRENTLY HAS ADEQUATE SIZE HOLDING _x001C_ TANK TO USE AS A TYPE III. VSL TO REPAIR TYPE II MSD PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 29 May 1996
Resolved 29 May 1996
Navigation
Issued 14 March 1996 Resolved
VSL HAS NO INLAND NAV RULES.
Condition: Unknown
Due 14 March 1996
Resolved 14 March 1996
Documentation
Issued 19 October 1995 Resolved
UPDATE OIL TRANSFER PROCEDURES IN ACCORDANCE WITH 33 CFR 155.750._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 February 1996
Resolved 28 February 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.