Records from 1985 to 2012. Most recent: inspection, 31 January 2012.
Inspection history · 41
31 January 2012
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4235131
13 September 2011
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4144028
16 November 2010
Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3892149
10 December 2008
Cargo Tank Internal · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3376707
13 November 2008
Drydock Extension
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3362473
6 November 2008
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3357880
9 October 2007
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3075769
13 September 2006
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2777132
7 December 2005
Internal Structural Exam · Cargo Tank Internal · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2547389
24 September 2004
MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2367705
2 February 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1998625
12 January 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1983314
10 November 2003
Hull Examination · Cargo Tank Internal · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1944924
16 January 2003
Annual Inspection · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1731253
19 September 2001
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1447142
7 November 2000
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1415485
16 September 1999
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1413607
17 November 1998
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 805640
17 November 1998
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 805641
3 November 1998
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 803282
8 October 1998
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1424649
5 September 1997
MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1398780
28 January 1997
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1363958
12 November 1996
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 863881
31 October 1995
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 884121
18 September 1995
Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1190579
10 September 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1189287
31 August 1995
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 212760
18 February 1994
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1163853
2 August 1993
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1156733
17 November 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 830375
12 May 1992
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 680398
20 April 1992
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 96027
20 April 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 954412
16 January 1992
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 947165
12 December 1990
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 907572
12 December 1990
MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 907694
2 August 1990
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1219689
15 September 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1313862
27 November 1985
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1298727
14 March 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1286705
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 13 September 2011
Resolved
Provide manufacture certificates for all hoses onboard the vessel & include hose serial numbers on hydro test reports prior to cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 September 2011
Resolved 19 September 2011
Resolution: Attended vsl and verified all cargo hoses were documented properly.
Electrical › Mast › Lightning Ground
Issued 16 November 2010
Resolved
Found dead end wiring on the mast of the forward mast head light. Remove dead end wiring.
Action required: 705 - Other - as specified
Due 16 December 2010
Resolved 22 November 2010
Resolution: Attended vessel and verified the repair to be satisfactory. The dead end wiring was removed.
Electrical › Lighting (service) › Lighting Fixture
Issued 16 November 2010
Resolved
The port and stbd navigation lights are portable & do not have a UL stamp. Provide the navigation light meet UL 1104 IAW NAV RULES.
Action required: 705 - Other - as specified
Due 16 December 2010
Resolved 19 November 2010
Resolution: Received email link to manufacture''''s website, stating the navigation lights meet UL 1104.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 16 December 2002
Resolved
Cargo manifold containment is wasted. LEGACY COMPONENT DESC: Cargo Manifold
Condition: Improper/Lack of Maintenance
Due 16 January 2003
Resolved 19 January 2006
Resolution: Replaced at drydock period
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 16 December 2002
Resolved
Sweep up all loose paint chips in the machinery space. (Slipping Hazard)
Condition: Improper/Lack of Maintenance
Due 16 January 2003
Resolved 9 September 2004
Resolution: Administratively cleared.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 December 2002
Resolved
Repaint Nav screens black matt
Condition: Improper/Lack of Maintenance
Due 16 January 2003
Resolved 9 September 2004
Resolution: Administratively cleared.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 16 December 2002
Resolved
Obtain mandated USCG oil record book.
Condition: Improper/Lack of Maintenance
Due 16 January 2003
Resolved 13 September 2006
Resolution: Vessel had purchased a new oil record book.
Operations/Management › Navigation Safety
Issued 16 December 2002
Resolved
Provide z-card for all members of crew, when requested for by USCG Inspectors.
Condition: Unknown
Due 16 December 2002
Resolved 16 December 2002
Resolution: Z-card provided.
Fire Fighting
Issued 3 November 1998
Resolved
Provide proof of servicing for fire extinguishers on board.
Condition: Unknown
Due 3 December 1998
Resolved 20 November 1998
Engineering
Issued 3 November 1998
Resolved
Label valve for cargo pump engine fuel shut off and prove proper operation to satisfaction of attending marine inspector.
Condition: Unknown
Due 3 December 1998
Resolved 20 November 1998
Deck/Cargo
Issued 5 September 1997
Resolved
CONDUCT AIR TEST OF #1 STBD CARGO TANK TO DETERMINE SOUNDNESS OF WELD IWO RUB RAIL AND DECK STRINGER.
Condition: Unknown
Due 20 October 1997
Resolved 24 October 1997
Deck/Cargo
Issued 5 September 1997
Resolved
REPAIR/REPLACE ALL UNDERSIZED HATCH DOGS ON CARGO ULLAGES
Condition: Unknown
Due 20 October 1997
Resolved 23 October 1997
Construction/Loadline
Issued 5 September 1997
Resolved
REPAIR/REPLACE GASKET IN STBD VESTIBULE WTD
Condition: Unknown
Due 20 October 1997
Resolved 24 October 1997
Unknown
Issued 5 September 1997
Resolved
PROVID COPY OF CERT OF FINANCIAL RESPONSIBILTY. CONTACTED NPFC TO VERIFY VSL HAS VALID CERT. VSL REP HAS CONTACTED NPFC FOR REPLACEMENT COPY.
Condition: Unknown
Due 20 October 1997
Resolved 24 October 1997
Deck/Cargo
Issued 5 September 1997
Resolved
INCREASE SIZE OF CONTAINMENT ON DECK TO 8 INCHES IN AFT CORNERS (14 FEET FORWARD AND 8 FEET INBOARD OF AFT CORNERS).
Condition: Unknown
Due 31 August 1998
Resolved 23 October 1997
Construction/Loadline
Issued 5 September 1997
Resolved
C/R STBD VESTIBULE AS MARKED TO SATISFACTION OF C.G. INSPECTOR
Condition: Unknown
Due 20 October 1997
Resolved 24 October 1997
Lifesaving
Issued 5 September 1997
Resolved
REPAIR/REPLACE STBD AND PORT VESTIBULE DOOR SO AS TO MAKE WATER PROOF.
Condition: Unknown
Due 5 September 1997
Resolved 5 September 1997
Fire Fighting
Issued 12 November 1996
Resolved
Install cargo pump room CO2 port. extinquisher in proper size bracket.
Condition: Unknown
Due 12 November 1996
Resolved 12 November 1996
Deck/Cargo
Issued 12 November 1996
Resolved
Install appropriate flame screens in gooseneck vents for foward rake._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 November 1996
Resolved 12 November 1996
Construction/Loadline
Issued 18 September 1995
Resolved
PROVIDE GAUGINGS AND SECTION MODULUS ANALYSIS REPORT.
Condition: Unknown
Due 18 September 1995
Resolved 18 September 1995
Construction/Loadline
Issued 18 September 1995
Resolved
BRING BATTERY SWITCH IN PUMP ENGINE ROOM INTO COMPLIANCE WITH 46CFR111.105_x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 September 1995
Resolved 18 September 1995