HAWK is a 1994 freight ship. The Coast Guard has recorded 13 inspections since 1995, most recently in October 2014, along with 10 deficiencies.

Records from 1995 to 2014. Most recent: inspection, 9 October 2014.

Built
1994
Last inspected
9 October 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9104483 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
416178
Flag
CYPRUS
—
Maury page id
psix-416178

Inspections, by type

…with no type recorded7
Years with a record 9 calendar years (1995–2014)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it26122 - Convention (Subpart B), Gross Ton
14868 - Convention (Subpart B), Net Ton
45111 - Dead Weight, Ton
52844 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 13

9 October 2014 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4998790
15 August 2005 ISPS II Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · NPV Safety Exam · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2464258
11 August 2005 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2459777
1 November 2004 ISPS II Exam · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2232139
5 January 2004 Annual Inspection · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1975695
8 January 2002 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1476749
6 January 2002 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1476114
2 October 2000 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 282745
20 February 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 425616
22 October 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 421237
29 March 1997 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 402197
19 June 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 379396
6 January 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 374055

Deficiency record · 10

Lifesaving › Lifebuoys › Not on Board
Issued 15 August 2005 Resolved
Provide ring buoys with rescue line at port and starboard pilot embarkation areas.
Action required: 705 - Other - as specified
Due 16 September 2005
Resolved 9 October 2009
Resolution: Life ring buoys fitted with rescue lines.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 15 August 2005 Resolved
Provide spray shielding on incinerator fuel oil pipe unions.
Action required: 705 - Other - as specified
Due 16 September 2005
Resolved 9 October 2009
Resolution: Spray shielding put in place.
Electrical › Electric Generation Source (service) › Generator
Issued 15 August 2005 Resolved
install missing high pressure fuel oil pump cover on all ship service generators.
Action required: 705 - Other - as specified
Due 16 September 2005
Resolved 9 October 2009
Resolution: Covers fitted on all high pressure fuel oil pumps.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 15 August 2005 Resolved
Provide electric insulating mats in front of anchor windlass switch board/controls in forepeak.
Action required: 705 - Other - as specified
Due 16 September 2005
Resolved 9 October 2009
Resolution: Not conductive matting put in place.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 5 January 2004 Resolved
Fix leak on CO2 System, IWO closer bottle to access ladder, prior to departure. And fax report to USCG. LEGACY COMPONENT DESC: Piping
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 January 2004
Resolution: The cylinder was taken ashore, and valve was rebuilt, cylinder was then recharged and placed back in service.
Electrical
Issued 6 January 2002 Resolved
REMOTE FUEL SHUT-OFF CABLE WAS NOT CONNECTED TO EMERGENCY SHUT-OFF VALVE IN EMERGENCY GENERATOR ROOM.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 January 2002
Resolved 8 January 2002
Fire Fighting
Issued 22 October 1998 Resolved
Prior to departure, perform satisfactory fire drill in the presence of a USCG marine inspector. SOLAS 74 II-2/20
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Fire Fighting
Issued 22 October 1998 Resolved
Prior to 12 November 1998, provide Flag State approval of the vessel's firecontrol plans. SOLAS 74 II-2/20
Condition: Unknown
Due 12 November 1998
Resolved 22 October 1998
Fire Fighting
Issued 22 October 1998 Resolved
Prior to 12 November 1998, place international shore connection in area specified by the vessel's fire control plan. SOLAS 74 II-2/20
Condition: Unknown
Due 12 November 1998
Resolved 22 October 1998
Documentation
Issued 22 October 1998 Resolved
Prior to completion of AEF, Flag administration to provide report to USCG attesting to satisfactory performance of fire drill.
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998

Ownership record