Records from 1995 to 2014. Most recent: inspection, 9 October 2014.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 13
9 October 2014
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4998790
15 August 2005
ISPS II Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · NPV Safety Exam · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2464258
11 August 2005
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2459777
1 November 2004
ISPS II Exam · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2232139
5 January 2004
Annual Inspection · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1975695
8 January 2002
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1476749
6 January 2002
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1476114
2 October 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 282745
20 February 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 425616
22 October 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 421237
29 March 1997
Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 402197
19 June 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 379396
6 January 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 374055
Lifesaving › Lifebuoys › Not on Board
Issued 15 August 2005
Resolved
Provide ring buoys with rescue line at port and starboard pilot embarkation areas.
Action required: 705 - Other - as specified
Due 16 September 2005
Resolved 9 October 2009
Resolution: Life ring buoys fitted with rescue lines.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 15 August 2005
Resolved
Provide spray shielding on incinerator fuel oil pipe unions.
Action required: 705 - Other - as specified
Due 16 September 2005
Resolved 9 October 2009
Resolution: Spray shielding put in place.
Electrical › Electric Generation Source (service) › Generator
Issued 15 August 2005
Resolved
install missing high pressure fuel oil pump cover on all ship service generators.
Action required: 705 - Other - as specified
Due 16 September 2005
Resolved 9 October 2009
Resolution: Covers fitted on all high pressure fuel oil pumps.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 15 August 2005
Resolved
Provide electric insulating mats in front of anchor windlass switch board/controls in forepeak.
Action required: 705 - Other - as specified
Due 16 September 2005
Resolved 9 October 2009
Resolution: Not conductive matting put in place.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 5 January 2004
Resolved
Fix leak on CO2 System, IWO closer bottle to access ladder, prior to departure. And fax report to USCG. LEGACY COMPONENT DESC: Piping
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 January 2004
Resolution: The cylinder was taken ashore, and valve was rebuilt, cylinder was then recharged and placed back in service.
Electrical
Issued 6 January 2002
Resolved
REMOTE FUEL SHUT-OFF CABLE WAS NOT CONNECTED TO EMERGENCY SHUT-OFF VALVE IN EMERGENCY GENERATOR ROOM.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 January 2002
Resolved 8 January 2002
Fire Fighting
Issued 22 October 1998
Resolved
Prior to departure, perform satisfactory fire drill in the presence of a USCG marine inspector. SOLAS 74 II-2/20
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Fire Fighting
Issued 22 October 1998
Resolved
Prior to 12 November 1998, provide Flag State approval of the vessel's firecontrol plans. SOLAS 74 II-2/20
Condition: Unknown
Due 12 November 1998
Resolved 22 October 1998
Fire Fighting
Issued 22 October 1998
Resolved
Prior to 12 November 1998, place international shore connection in area specified by the vessel's fire control plan. SOLAS 74 II-2/20
Condition: Unknown
Due 12 November 1998
Resolved 22 October 1998
Documentation
Issued 22 October 1998
Resolved
Prior to completion of AEF, Flag administration to provide report to USCG attesting to satisfactory performance of fire drill.
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998