ATLANTIC is a 1995 tank barge. The Coast Guard has recorded 80 inspections since 1995, most recently in March 2020, along with 79 deficiencies and 2 operational controls.

Records from 1995 to 2020. Most recent: inspection, 23 March 2020.

Built
1995
Last inspected
23 March 2020
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 23 March 2020
…with no type recorded32
Operational controls None recorded without a removal date
Years with a record 23 calendar years (1995–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCP7873
416194
Flag
UNITED STATES
Maury page id
psix-416194

Documentation record

Tonnage as PSIX records it8327 - Convention (Subpart B), Gross Ton
5750 - Convention (Subpart B), Net Ton
3805 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

Inspection history · 80

23 March 2020 Administrative Inspection · MARPOL Annex I Examination · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6929568
27 March 2019 MTSA Verification · Annual Inspection · Administrative Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6650570
30 October 2017 Periodic Inspection · Administrative Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6297301
10 February 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6087145
8 February 2017 Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6082313
29 September 2016 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6012656
24 August 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5981672
26 January 2016 MARPOL Annex I Examination · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5803822
21 December 2015 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5787084
29 July 2015 Deficiency Check · Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5200912
26 January 2015 Deficiency Check · Administrative Inspection · Annual Inspection · Hull Examination · Internal Structural Exam · Cargo Tank Internal · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5059153
21 January 2015 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5056323
8 December 2014 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5037847
12 June 2014 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4887233
28 April 2014 Deficiency Check · MARPOL Annex VI Survey · MARPOL Annex I Examination · MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4843588
28 February 2014 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4807758
19 August 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4415356
26 April 2012 Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4293241
4 June 2010 Damage Survey · Examination of Repairs
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3757745
10 February 2010 Administrative Inspection · Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3677548
8 April 2009 Periodic Inspection · MTSA/ISPS Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3448695
1 July 2008 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3252424
23 June 2008 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3245830
14 May 2008 Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3204796
31 January 2008 Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3141270
5 July 2007 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2982261
14 May 2007 Annual Inspection · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2930106
7 March 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2597889
24 February 2006 COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2591180
27 January 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2597591
20 October 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2525540
14 February 2005 Examination of Repairs
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2293485
1 February 2005 Annual Inspection · Internal Structural Exam · Hull Examination · MTSA/ISPS Verification · Cargo Tank Internal
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2302604
9 November 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2238032
26 October 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2228555
29 July 2004 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2148743
19 April 2004 Periodic Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2047737
23 March 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2061771
17 February 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2016374
9 February 2004 MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2002905
12 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1980825
7 March 2003 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1751849
27 February 2003 Internal Structural Exam · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1751865
10 April 2002 Annual Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1600737
28 February 2001 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1058706
26 January 2001 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1444455
27 September 2000 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 822436
1 June 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 278493
27 May 2000 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 526899
5 April 2000 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1426360
22 February 2000 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1426333
7 October 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 540370
2 October 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 25019
12 April 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 451330
1 February 1999 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1410024
2 September 1998 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 117062
11 August 1998 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 488626
20 June 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 147293
22 May 1998 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1438731
20 April 1998 Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 790269
15 March 1998 Damage Survey
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1122491
22 December 1997 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1116828
3 November 1997 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 450031
3 May 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 98578
14 February 1997 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1092038
6 November 1996 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 397048
10 October 1996 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 199207
10 October 1996 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 752087
10 October 1996 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 841073
1 October 1996 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 675908
27 September 1996 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 485515
17 April 1996 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1079900
17 January 1996 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 873127
14 December 1995 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 881058
25 August 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 524587
16 August 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 129746
8 June 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 755544
3 June 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 199208
20 April 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 99691
27 February 1995 Initial Construction-Excluding Oversight · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1390074

Deficiency record · 79

Deck/Cargo › Mooring/Anchoring › Anchor
Issued 10 February 2017 Resolved
Vessel must provide a class report attesting to satisfactory replacement of anchor as well as provide a salvage plan documenting how the lost anchor will be located and recovered.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 10 February 2017
Resolved 20 February 2017
Resolution: Vessel provided a salvage plan for lost anchor on 2/13 and a class report attesting to proper replacement of anchor on 2/15.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 24 August 2016 Resolved
Vessel lost anchor at Kenner Bend Anchorage. Replace anchor. Submit class report.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2016
Resolved 24 August 2016
Resolution: Anchor replaced. Class report accepted.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 21 December 2015 Resolved
Vsl lost anchor while transiting LMR. Vsl authorized transit to [name withheld] Wharf for repairs, with tug alongside. Issued CG-835.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 December 2015
Resolved 25 December 2015
Resolution: Received verification that new anchor was installed. Cleared CG-835. Vessel is clear to depart. Salvage operations for lost anchor to begin 28DEC2015.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 29 July 2015 Resolved
Vessel's windlass and anchor were damaged during deployment resulting in a complete loss of anchor and anchor cable and damage to windlass bearings and couplings. Complete permanent repairs prior to sailing.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 August 2015
Resolved 31 July 2015
Resolution: Witnessed satisfactory operational test of anchor windlass and associated gear. Test Sat.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 23 March 2015 Resolved
Anchor windless has a leaking O-ring. 46CFR96.07
Action required: 705 - Other - as specified
Resolved 24 March 2015
Resolution: Vessel rep proved proper operation of anchor windless.
Construction/Loadline › Hull › Keel
Issued 26 January 2015 Resolved
Anchor Chaffing Bar on bow keel wasted and holed. Make repair proposal. 46 CFR 31.10-21
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2015
Resolution: Repairs made while in dock.
Deck/Cargo › Cargo Heating › General
Issued 26 January 2015 Resolved
Several Thermal Fluid Heater Manifolds and valves located on deck were found wasted and in poor condition. Make proper repairs. 46 CFR 61.30-15
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2015
Resolution: All manifolds replaced new in kind.
Construction/Loadline › Structures › Deck Plating
Issued 26 January 2015 Resolved
Deck/tank top under P&S TFH house found pitting. Gauge and provide repair proposal to areas exceeding allowable wastage. 46 CFR 31.10-21
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2015
Resolution: Q-Sea conducted UT shots, small areas that exceeded allowance were authorized to clad weld. Repairs inspected by ABS and CG, satisfactorily.
Construction/Loadline › Structures › Deck Plating
Issued 26 January 2015 Resolved
Decks in both TFH house found w/areas wasted through and patched. Make repairs. 46 CFR 31.10-21
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2015
Resolution: Cropped and renewed.
Deck/Cargo › Cargo Heating › General
Issued 26 January 2015 Resolved
Crop and renew TFH piping with doubler patches under P&S TFH house above deck. Gauge wasted piping, crop and renew as needed. 46 CFR 61.30-15
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2015
Resolution: Piping replaced new in kind.
Electrical › Electric Generation Source (service) › Conductor
Issued 26 January 2015 Resolved
Replace/Renew wasted electrical boxes and conduit on P&S TFH houses P&S. 46 CFR 120.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2015
Resolution: Replaced.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 26 January 2015 Resolved
Crop and new all wasted cargo hatch hinges, hinge pins and dogging ears on Cargo Hatches. 46 CFR 31.10-21
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2015
Resolution: Replaced new in kind.
Deck/Cargo › Holds/Tanks › Ventilation Exhaust Outlet
Issued 26 January 2015 Resolved
Noted several goose-neck vents (Cargo, Ballast & Fuel Tank) wasted and holed. Crop and renew. 46 CFR 32.55
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2015
Resolution: Repaired or replaced.
Accommodation/Occupational Safety › Ventilation › General
Issued 26 January 2015 Resolved
Vent closure to the machinery generator room, located on the roof of the Port TFH house is facing aft and is inaccessible to all dogging devices, creating a falling hazard for the crew. Provide safer means for crew to close the vent. Provide repair proposal. 46 CFR 34.15-35
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2015
Resolution: Vent turned 180 degrees.
Deck/Cargo › Holds/Tanks › Hatch
Issued 26 January 2015 Resolved
Hatches and flanges to the aft diesel tanks, voids, intercon voids on main deck and hatches/flanges on the roof of both the Port and Starboard TFH houses are wasted. Replace. 46 CFR 31.10-21
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2015
Resolution: Replaced new in kind.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 26 January 2015 Resolved
Hand rail on forward starboard side bow wasted. Repair 46 CFR 32.02-15
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2015
Resolution: Repaired
Engineering › Fuel Oil Service System › Vent Pipe
Issued 26 January 2015 Resolved
Repair/replace wasted gooseneck vents on TFH houses fuel day tanks (P&S). 46 CFR 56.50-85
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2015
Resolution: Repaired
Engineering › Fuel Oil Service System › Piping
Issued 26 January 2015 Resolved
Diesel fuel day tank valves and piping on forward TFH houses (P&S) located inboard and forward show signs of leaking and have thread tape on fittings. Repair/replace 46 CFR 56.50-60
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2015
Resolution: Piping and valves replaced new in kind.
Construction/Loadline › Structures › Door
Issued 26 January 2015 Resolved
Inspect and repair all Watertight Doors (WTD) for fit and seal. This includes wasted hinges and gaskets. 46 CFR 42.15-10
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2015
Resolution: Repaired/replaced new in kind, chalk test satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 26 January 2015 Resolved
Replace all wasted platform grates in Ballast Tank entry ladders. 46 CFR 32.02-15
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2015
Resolution: Replaced new in kind.
Deck/Cargo › Ballast › Tank
Issued 26 January 2015 Resolved
Pick-up weld in Ballast Tank #3 Starboard forward bulkhead bracket. 46 CFR 31.10-21
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2015
Resolution: Repaired
Construction/Loadline › Structures › Cofferdam
Issued 26 January 2015 Resolved
Cargo Leak found in aft Cofferdam at 3rd swash bulkhead to starboard from entry hatch between the 1st and 2nd transverse frame above deck. Provide repair proposal as this seems to be a reoccurring issue from an old repair. Upon completion, pressure test cargo tank. 46 CFR 31.10-21
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2015
Resolution: Cropped and renewed, leak test satisfactory.
Construction/Loadline › Structures › Deck Plating
Issued 26 January 2015 Resolved
Gauge day tank, tank tops in pits on roof of the TFH houses. 46 CFR 31.10-21
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2015
Resolution: Q-Sea conducted.
Engineering › Thrusters › Piping
Issued 26 January 2015 Resolved
Gauge Bow Thruster pipe dome (just above ballast pump impeller) and pipe just above connection flange for wastage. 46 CFR 31.10-21
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2015
Resolution: Q-Sea, gauging was satisfactory.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 26 January 2015 Resolved
Gauge cargo piping (in pits for wastage) crop and renew as needed. 46 CFR 31.10-21
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2015
Resolution: Area of pitting cropped and renewed.
Deck/Cargo › Cargo Heating › General
Issued 26 January 2015 Resolved
Thermal Fluid Heater piping under both P & S houses were leaking fluid (3 leaks) through the welds at deck/pipe junction in new pipe installation. Make proper repairs. (see narrative for details)
Action required: 705 - Other - as specified
Resolved 20 March 2015
Resolution: Cropped and renewed.
Deck/Cargo › Cargo Heating › General
Issued 26 January 2015 Resolved
Replace damaged rotating machinery guard on port TFH electric motor. 46 CFR 58.01-20
Action required: 705 - Other - as specified
Resolved 25 March 2015
Resolution: Guard was place on damaged machinery guard on the TFH elecrtic motor.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 28 April 2014 Resolved
Repair stbd prime mover discharge cargo pump emergency shutdown.
Action required: 705 - Other - as specified
Due 30 May 2014
Resolved 23 May 2014
Resolution: Witnessed satisfactory test of emergency shutdown
Electrical › Electrical Distribution System (service) › Panelboard
Issued 28 April 2014 Resolved
Install drip shield on electrical distribution panel under ladder down to the bow thruster room.
Action required: 705 - Other - as specified
Due 30 May 2014
Resolved 23 May 2014
Resolution: Drip shield installed
Stability › Watertight Integrity › General
Issued 28 April 2014 Resolved
Replace gaskets on forward watertight doors of pump rooms.
Action required: 705 - Other - as specified
Due 30 May 2014
Resolved 23 May 2014
Resolution: Gaskets replaced
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 28 April 2014 Resolved
Install chaffing gear on inboard of cargo pump engines as needed.
Action required: 705 - Other - as specified
Due 30 May 2014
Resolved 23 May 2014
Resolution: Installed chaffing gear
Stability › Watertight Integrity › General
Issued 28 April 2014 Resolved
Reseat the inboard WTD gasket on stbd pump room.
Action required: 705 - Other - as specified
Due 30 May 2014
Resolved 23 May 2014
Resolution: Completed
Electrical › Electrical Distribution System (service) › Panelboard
Issued 28 April 2014 Resolved
Replace generator space breaker panel door.
Action required: 705 - Other - as specified
Due 30 May 2014
Resolved 23 May 2014
Resolution: Completed
Stability › Watertight Integrity › General
Issued 28 April 2014 Resolved
Make machinery vent closure dogs operable.
Action required: 705 - Other - as specified
Due 30 May 2014
Resolved 23 May 2014
Resolution: Owner had new vent closer installed.
Fire Fighting › Ventilation Systems › Ducts
Issued 28 April 2014 Resolved
Crop and renew stbd inboard vent closure for machinery space.
Action required: 705 - Other - as specified
Due 30 May 2014
Resolved 23 May 2014
Resolution: Owner had vent closure renewed.
Electrical › Electrical Distribution System (service) › Switch
Issued 28 April 2014 Resolved
Repair pump stop button in port thermal fluid heater space.
Action required: 705 - Other - as specified
Due 30 May 2014
Resolved 23 May 2014
Resolution: Owner had tech rep attend barge and make needed repairs, provided tech report for documentation.
Electrical › Electrical Distribution System (service) › Cable
Issued 28 April 2014 Resolved
Properly dead end electrical cable in generator space.
Action required: 705 - Other - as specified
Due 30 May 2014
Resolved 23 May 2014
Resolution: Completed
Engineering › Diesel Engine (auxiliary) › Governor
Issued 28 April 2014 Resolved
Replace hose on hotel generator as marked.
Action required: 705 - Other - as specified
Due 30 May 2014
Resolved 23 May 2014
Resolution: Completed
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 28 April 2014 Resolved
Replace hose on paint locker fixed CO2 bottle.
Action required: 705 - Other - as specified
Due 30 May 2014
Resolved 23 May 2014
Resolution: Completed
Deck/Cargo › Cargo Heating › General
Issued 28 April 2014 Resolved
Provide 3rd party tech reports for the following: 1) Operation of the day tank hi-level alarm; 2) Operation of generator space blower shutoff; 3) Operation of #1 generator; 4) Results for internal inspection of both thermal fluid heaters; 5) Results for safety test procedures for both thermal fluid heaters.
Action required: 705 - Other - as specified
Due 30 May 2014
Resolved 23 May 2014
Resolution: Volcanic tech visited the barge to clear this discrepancy. Tech conducted internal exam, alarms tests, and operational test of both fluid heaters.
Stability › Watertight Integrity › General
Issued 28 April 2014 Resolved
Adjust all WTD's.
Action required: 705 - Other - as specified
Due 30 May 2014
Resolved 23 May 2014
Resolution: Completed
Stability › Watertight Integrity › Weathertight Enclosure
Issued 28 April 2014 Resolved
Provide dogging wrenches for office, port cargo pump room, and port thermal fluid heater WTD's.
Action required: 705 - Other - as specified
Due 30 May 2014
Resolved 23 May 2014
Resolution: Completed
Deck/Cargo › Cargo Heating › General
Issued 28 April 2014 Resolved
Replace port thermal fluid heater exhaust closure gasket.
Action required: 705 - Other - as specified
Due 30 May 2014
Resolved 16 May 2014
Resolution: Completed
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 14 May 2008 Resolved
Provide non-conductive deck coverings in front of the switchboards in the generator room (3) in accordance with 46 CFR 111.30-11
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 1 July 2008
Resolution: Non-conductive deck coverings provided in front of the switchboards in the generator room.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 14 May 2008 Resolved
Permanently attach all ballast tank hatches to the barge.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 1 July 2008
Resolution: Ballast tank hatches permanently attached to the barge.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 14 May 2008 Resolved
Remove the paint locker from the barge or provide proof it is approved to be on board
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 1 July 2008
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 14 May 2008 Resolved
Prove proper operation of the #2 generator overspeed trip in accordance with 46 CFR 111.12-11
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 1 July 2008
Resolution: Demonstrated proper operation of the #2 generator overspeed trip.
Deck/Cargo › Cargo Heating › General
Issued 14 May 2008 Resolved
Prove the proper operation of the manual push-button shutdown on the starboard thermal fluid heater in accordance with 46 CFR 61.30-20
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 1 July 2008
Resolution: Demonstrated the proper operation of the manual push-button shutdown on the starboard thermal fluid heater.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 14 May 2007 Resolved
Remove all paint containers from inside the tug ELIZA.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2007
Resolved 5 July 2007
Resolution: Removed cans.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 14 May 2007 Resolved
Remove paint locker from barge until an approved fixed firefighting system is installed.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2007
Resolved 5 July 2007
Resolution: After consultation with the CID, the container meets the requirements of 46 CFR 32 and 34. Satisfactory without change.
Deck/Cargo › Cargo Heating › General
Issued 14 May 2007 Resolved
Renew fuel oil pressure guage on the STBD thermal fluid heater.
Action required: 705 - Other - as specified
Due 18 June 2007
Resolved 5 July 2007
Resolution: New gauge installed.
Fire Fighting › Remote Fuel Shutoff › General
Issued 14 May 2007 Resolved
Demonstrate proper operation of the port side hydraulic pressure unit fuel tank and the bow thruster fuel tank remote shut-off valves.
Action required: 705 - Other - as specified
Due 18 June 2007
Resolved 5 July 2007
Resolution: Reach rods and valves tested satisfactorily.
Stability › Watertight Integrity › General
Issued 14 May 2007 Resolved
Renew or replace STBD aft thermal fluid heater compartment water tight door. 6/13/07 - OCMI approved extension of resolution date to drydock prior to 2/27/08.
Action required: 705 - Other - as specified
Due 27 February 2008
Resolved 28 February 2008
Resolution: Water tight door was replaced during drydock.
Fire Fighting › Remote Fuel Shutoff › General
Issued 14 May 2007 Resolved
Properly secure STBD emergency shutdown switch box for the STBD thermal fluid heater compartment.
Action required: 705 - Other - as specified
Due 18 June 2007
Resolved 5 July 2007
Resolution: Switch is properly secured to the bulkhead.
Deck/Cargo › Cargo Heating › General
Issued 14 May 2007 Resolved
Update the thermal fluid heater test procedures to reflect the proper procedures for the air pressure switch and the non-recycling interlock.
Action required: 705 - Other - as specified
Due 18 June 2007
Resolved 5 July 2007
Resolution: Procedures updated to reflect the new unit installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 May 2007 Resolved
Properly support wiring for the bow thruster from battery to starter.
Action required: 705 - Other - as specified
Due 18 June 2007
Resolved 10 July 2007
Resolution: Properly supported wiring for the bow thruster and confirmed with a digital photo to CWO R.S.Moseley [phone withheld].
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 14 May 2007 Resolved
Install blank in distribution panel in bow thruster compartment.
Action required: 705 - Other - as specified
Due 18 June 2007
Resolved 5 July 2007
Resolution: All blanks are present. Panel registers are being revised to reflect ampacity.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 May 2007 Resolved
Repair exhaust lagging on the port prime mover.
Action required: 705 - Other - as specified
Due 18 June 2007
Resolved 5 July 2007
Resolution: Prime mover lagging is in place and properly affixed.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 14 May 2007 Resolved
Renew STBD cargo hose.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2007
Resolved 5 July 2007
Resolution: STBD cargo hose has been removed and painted along the hose DO NOT USE in red paint in preparation for disposal upon return to New Orleans.
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 14 May 2007 Resolved
Properly secure worklight wiring to support brackets.
Action required: 705 - Other - as specified
Due 18 June 2007
Resolved 5 July 2007
Resolution: All brackets in place and a box of spares is now onboard.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 24 February 2006 Resolved
Low lube oil pressure switch inoperable.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 March 2006
Resolved 22 March 2006
Resolution: Verified by report from Bluewater Electric, LLC. that pressure swithc replaced and tested sat.
Engineering › Diesel Engine (propulsion-electric) › Pump, High Pressure (fuel injection)
Issued 21 April 2004 Resolved
Remove plastic drain plug in Fuel/Oil filter bowl with metal one LEGACY COMPONENT DESC: Filter/Strainer
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 May 2004
Resolved 28 July 2004
Resolution: Engineer removed all drain plugs, all sat.
Engineering › Diesel Engine (propulsion-electric) › Gear/Clutch Starter (electric)
Issued 21 April 2004 Resolved
Replace damaged starting cables on #2 Generator LEGACY COMPONENT DESC: Gear/Clutch Starter (electric)
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 May 2004
Resolved 28 July 2004
Resolution: Visual inspect new cable, all sat.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 21 April 2004 Resolved
Replace drip shield on distribution panel in generator room LEGACY COMPONENT DESC: Junction Box
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 May 2004
Resolved 28 July 2004
Resolution: All sat.
Engineering › Diesel Engine (propulsion-electric) › Bedplate
Issued 21 April 2004 Resolved
Wipe up excess fuel/oil and lub oil in generator room
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 May 2004
Resolved 28 July 2004
Resolution: All sat.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 10 April 2002 Resolved
Replace #2 generator temperature gauge.
Condition: Unknown
Due 10 April 2002
Resolved 10 April 2002
Deck/Cargo › Cargo Heating
Issued 10 April 2002 Resolved
Renew stbd Thermal Fluid Heater temperature gauge. LEGACY COMPONENT DESC: TFH
Condition: Unknown
Due 10 April 2002
Resolved 10 April 2002
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 10 April 2002 Resolved
Ensure free movement of all P/V valves due to cargo vapor build up hindering movement.
Due 10 April 2002
Resolved 10 April 2002
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 10 April 2002 Resolved
Clean all flame screens.
Due 10 April 2002
Resolved 10 April 2002
Deck/Cargo
Issued 26 January 2001 Resolved
MAKE ALL P/V VALVES READY FOR INSPECTION.
Condition: Unknown
Due 26 January 2001
Resolved 26 January 2001
Deck/Cargo
Issued 26 January 2001 Resolved
PROVE PROPER OPERATION OF ALL LIMIT AND SAFETY CONTROLS ON BOTH THERMAL FLUID HEATERS.
Condition: Unknown
Due 26 January 2001
Resolved 26 January 2001
Electrical
Issued 26 January 2001 Resolved
REPLACE LEAKING SEALS ON GENERATOR AND PROVE PROPER OPERATION.
Condition: Unknown
Due 26 January 2001
Resolved 26 January 2001
Deck/Cargo
Issued 26 January 2001 Resolved
REPLACE ALL NON-RISING STEM VALVES WITH RISING STEM VALVES OR INSTALL POSITION INDICATORS ON EXISTING NON-RISING STEM VALVES BY NEXT CARGO TANK INTERNAL.
Condition: Unknown
Due 27 February 2005
Resolved 10 April 2002
Deck/Cargo
Issued 22 February 2000 Resolved
Prior to the carriage of cargo make permanent repair to the # 5 cargo tank portside in way of # 5 double bottom ballast tank, small leak at the fwd most bay of the double bottom 3 inches from center line bulkhead. Provide an ABS report attesting to satifactory repair to [name withheld].
Condition: Unknown
Due 22 February 2000
Resolved 22 February 2000
Deck/Cargo
Issued 22 February 2000 Resolved
Prior to the carriage of cargo make permanent repair to the # 5 cargo tank suction sump starboard side in way of # 5 ballast tank, small leak at weld of sump. Provide an ABS report attesting to the satisfactory repair to OCMIMiami.
Condition: Unknown
Due 22 February 2000
Resolved 22 February 2000
Construction/Loadline
Issued 22 February 2000 Resolved
Provide an ABS report to the [name withheld] as to the condition of bottom plating in area of buckeled longs and braces in double bottom ballast tanksnumber 3 port/starboard and # 4 starboard.
Condition: Unknown
Due 22 February 2000
Resolved 22 February 2000
Engineering
Issued 20 April 1998 Resolved
PROVE TO ATTENDING MARINE INSPECTOR PROPER OPERATION OF ALL MACHINERY TO INCLUDE BOTH THERMAL FLUID HEATERS. VSL NOT TO OPERATE UNTIL THIS CG-835 ISCLEARED.
Condition: Unknown
Due 20 April 1998
Resolved 22 April 1998
Deck/Cargo
Issued 15 March 1998 Resolved
MAKE PERMANENT REPAIRS AND PROVE PROPER OPERATION OF ANCHOR WINDLASS.
Condition: Unknown
Due 16 April 1998
Resolved 23 March 1998
Documentation
Issued 27 February 1995 Resolved
PROVIDE ON BOARD AN APPROVED SHIP BOARD OIL POLLUTION EMERGENCY PLAN AS REQUIRED BY REG 26 OF MARPOL.
Condition: Unknown
Due 4 April 1995
Resolved 13 June 1995

Ownership record