← All vessels
OURANIA HOPE
OURANIA HOPE is a 1989 freight ship. The Coast Guard has recorded 17 inspections since 1990, most recently in September 2005, along with 6 deficiencies and 1 operational control.
Records from 1990 to 2005. Most recent: inspection, 14 September 2005.
- Built
- 1989
- Last inspected
- 14 September 2005
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 6 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8900488 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9AND
416333
Flag
MALTA
—
Maury page id
psix-416333
Inspections, by type
The 17 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it36120 - Convention (Subpart B), Gross Ton
36120 - Regulatory (Subpart C or D), Gross Ton
23035 - Convention (Subpart B), Net Ton
23035 - Regulatory (Subpart C or D), Net Ton
68676 - Dead Weight, Metric Ton
78400 - Displacement, Metric Ton
36120 - Regulatory (Subpart C or D), Gross Ton
23035 - Convention (Subpart B), Net Ton
23035 - Regulatory (Subpart C or D), Net Ton
68676 - Dead Weight, Metric Ton
78400 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 17
14 September 2005
Spot Check · Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2481885
21 January 2005
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2278387
18 February 2004
Administrative Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2008569
22 January 2004
Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1990931
6 January 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1726571
2 December 2002
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1728024
3 June 2002
Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1625624
28 October 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 283580
22 June 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 429980
14 February 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 425469
27 May 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 404042
11 December 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 385510
23 November 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 372973
23 November 1994
Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 868487
25 June 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 445357
19 March 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 342450
18 February 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 335529
Deficiency record · 6
Pollution Prevention/Response › Prevention Equipment
Issued 22 January 2004
Resolved
The oily water separator's three-way valve is inoperative. When 15ppm is detected, the valve remains in the open position. Use of the OWS is prohibited in U.S. waters until proper operation can be proven. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Lifesaving
Issued 14 February 1999
Resolved
Renew markings on all liferaft containers. SOLAS 74 amd III/39.7.3 Correctprior to next U.S. port.
Fire Fighting
Issued 14 February 1999
Resolved
Renew or properly repair fire main where holed: aft of #6 cargo, 2 places stbd of #6 cargo and 1 place stbd of #5 cargo on main deck. The leaks did not significantly reduce fire main pressure. SOLAS 74 amd II-2/4. Correctprior to next U.S. Port.
Lifesaving
Issued 23 November 1994
Resolved
Vessel missing weaklinks for port liferafts.
Fire Fighting
Issued 23 November 1994
Resolved
Vessels fire main at cargo holds #3, and #5 had holes.
Lifesaving
Issued 23 November 1994
Resolved
Vessels emergency breathing apparatus needs hydro testing.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.