Records from 2005 to 2026. Most recent: inspection, 17 March 2026.
Documentation record
Registered dimensions (L × B × D)84.8 ft × 22.6 ft × 8.1 ft
Registered tonnagegross 88 / net 60
ITC dimensions (L × B × D)84.8 ft × 22.6 ft × 8.1 ft
ITC tonnagegross 175 / net 76
BuilderBREAUX BROTHERS ENTERPRISES INC · LOREAUVILLE, LA, UNITED STATES · built 1995
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portWILMINGTON, DE
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 25 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it175 - Convention (Subpart B), Gross Ton
88 - Regulatory (Subpart C or D), Gross Ton
76 - Convention (Subpart B), Net Ton
60 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 25
17 March 2026
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8282184
17 August 2025
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8204876
26 February 2025
Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7923301
4 February 2025
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7927716
3 November 2024
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8023606
24 April 2024
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7867583
13 December 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7810805
18 September 2023
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7793695
4 May 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7675500
5 April 2023
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7624686
8 March 2023
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7606499
11 May 2022
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7448436
19 October 2021
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7335967
8 July 2021
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7250047
6 July 2021
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7247525
2 March 2021
Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7148438
11 January 2021
Drydock Extension · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7127871
10 February 2020
COI Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6902135
7 May 2019
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6645251
2 January 2019
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6562587
18 April 2018
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6347957
8 February 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6082024
6 January 2017
Plan Review (Other than "T")
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6084327
4 January 2017
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6065685
4 May 2016
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5858416
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 17 March 2026
Resolved
An exposed hazard, such as gears or rotating machinery, must be protected by a cover, guard, or rail. MI observed rotating shaft on the port side of the engine room was not protected by a cover or guard. Install protective equipment around rotating port shaft.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2026
Resolved 7 April 2026
Resolution: Received picture of repairs-all sat
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 17 March 2026
Resolved
Ceilings, linings, and any furring incidental to their installation in control spaces, passageways, stairways, accommodation spaces and service spaces must be of noncombustible material. MI observed detached ceiling lining in the lazarette. Repair and secure lining.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2026
Resolved 7 April 2026
Resolution: Received picture of repairs-all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 February 2025
Resolved
46CFR 183.10, The general electrical installation shall be installed with metal supports spaced not more than 24 inches apart, and in such a manner as to avoid chafing and other damage. Marine Inspector found spacing greater than 24 inches throughout the engine room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2025
Resolved 18 February 2025
Resolution: Metal supports are installed and within 24 inches.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 February 2025
Resolved
33 CFR 83.33 states a vessel of 20 meters or more in length shall be provided with a bell in addition to a whistle. Marine Inspector identified no bell on board.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2025
Resolved 18 February 2025
Resolution: The proper bell size is onboard
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 April 2024
Resolved
A vessel on a limited coastwise route must carry six red and six orange flares. Vessel was in possession of 05 red flares.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2024
Resolution: Received pictures showing the deficiency corrected.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 24 April 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date charts. Vessel's charts were last updated in 2013.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 May 2024
Resolution: Received pictures showing the deficiency corrected.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 April 2024
Resolved
Penetrations and openings in watertight bulkheads must be watertight. Penetration in the engine room aft bulkhead has separated from bulkhead.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 May 2024
Resolution: Received pictures showing the deficiency corrected.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 May 2022
Resolved
Fire alarm detection system at operating station failed on standby power supply. Repair
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2022
Resolved 10 June 2022
Resolution: Corrected verified by MI.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 11 May 2022
Resolved
Three emergency lighting units at upper deck passenger area SBTD side not operational. Repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2022
Resolved 10 June 2022
Resolution: Corrected; verified by MI.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 11 May 2022
Resolved
Engine room at forward bulkhead overhead light fixture missing it diffuser cover. Repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2022
Resolved 15 June 2022
Resolution: Repaired. Verified by MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 11 May 2022
Resolved
Potable water system in Void space #3; outboard pump unit gauge broken. Repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2022
Resolved 10 June 2022
Resolution: Replaced gauge unit.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 May 2022
Resolved
Upper deck head light fixture over sink missing bulb & diffuser cover. Repair
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2022
Resolved 15 June 2022
Resolution: Repaired; verified by MI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 July 2021
Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date of the COI. Vessel exceeded 3 month interval on 10MAY2020. Vessel is required to complete a satisfactory annual inspection prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2021
Resolution: MI conducted Annual Inspection.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 May 2019
Resolved
Fire hose nozzles shall be made of bronze or same strength and corrosion resistant materials. Both stations equipped with plastic nozzles.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2019
Resolved 9 May 2019
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 7 May 2019
Resolved
Provide updated navigational charts
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2019
Resolved 9 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 May 2019
Resolved
Replace painter line on STBD lifefloat group.
Vessel limited to lakes, bays and sounds route.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2019
Resolved 9 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 May 2019
Resolved
Provide 12 distress signals.
Vessel limited to lakes, bays and sounds route.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2019
Resolved 9 May 2019
Electrical › Electric Generation Source (service) › Generator
Issued 18 April 2018
Resolved
Clean starboard side generator windings to prevent fire hazards from electrical equipment. Shall be cleaned prior to operation of the generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2018
Resolved 27 April 2018
Resolution: Starboard generator windings were cleaned satisfactorily.
Lifesaving › Lifefloat › Painter
Issued 8 February 2017
Resolved
Provide proper tethering connections for all lifefloats in port side lifefloat stack.
Action required: 705 - Other - as specified
Due 8 February 2017
Resolved 8 February 2017
Resolution: Vessel crew removed wasted tethering loop on topmost lifefloat, re-installed painter lines between middle and topmost lifefloat, all satisfactory.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 8 February 2017
Resolved
Vessel crew shall properly log monthly EPIRB testing, provide approproiate log book for entry.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 February 2017
Resolved 8 February 2017
Resolution: Vessel crew provided EPIRB log book to resume monthly EPIRB testing as required.
Lifesaving › Lifebuoys › Serviceable
Issued 4 May 2016
Resolved
Grab line was deteriorated on 24 inch Ring Lifebuoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 May 2016
Resolved 4 May 2016
Resolution: Replace Ring Lifebuoy, including grab lines.