MAURY USCG vessel records Sign in
← All vessels

DREAM ON

DREAM ON is a 1995 passenger vessel (inspected). The Coast Guard has recorded 71 inspections since 1995, most recently in March 2026, along with 50 deficiencies, 1 operational control and 1 casualty investigation in 2005.

Records from 1995 to 2026. Most recent: inspection, 17 March 2026.

Built
1995
Last inspected
17 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC8659
416582
Flag
UNITED STATES
367090960
Maury page id
psix-416582

Inspections, by type

…with no type recorded6
Years with a record 30 calendar years (1995–2026)
The 71 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)84.8 ft × 22.6 ft × 8.1 ft
Registered tonnagegross 88 / net 60
ITC dimensions (L × B × D)84.8 ft × 22.6 ft × 8.1 ft
ITC tonnagegross 175 / net 76
BuilderBREAUX BROTHERS ENTERPRISES INC · LOREAUVILLE, LA, UNITED STATES · built 1995
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portWILMINGTON, DE
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 25 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it175 - Convention (Subpart B), Gross Ton
88 - Regulatory (Subpart C or D), Gross Ton
76 - Convention (Subpart B), Net Ton
60 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI7492MMSI 367090960 · active · compulsorily equipped · granted 2 April 2026, expires 21 April 2036
WDC8659MMSI 367090960 · expired · compulsorily equipped · granted 3 February 2006, cancelled 9 April 2016
WCQ3326MMSI not assigned · expired · compulsorily equipped · granted 7 March 1995, cancelled 7 May 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 71

17 March 2026 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8282184
17 August 2025 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8204876
26 February 2025 Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7923301
4 February 2025 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7927716
3 November 2024 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8023606
24 April 2024 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7867583
13 December 2023 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7810805
18 September 2023 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7793695
4 May 2023 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7675500
5 April 2023 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7624686
8 March 2023 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7606499
11 May 2022 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7448436
19 October 2021 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7335967
8 July 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7250047
6 July 2021 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7247525
2 March 2021 Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7148438
11 January 2021 Drydock Extension · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7127871
10 February 2020 COI Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6902135
7 May 2019 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6645251
2 January 2019 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6562587
18 April 2018 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6347957
8 February 2017 Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6082024
6 January 2017 Plan Review (Other than "T")
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6084327
4 January 2017 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6065685
4 May 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5858416
5 May 2014 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4836735
15 May 2012 DAPI Audit · Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4321699
3 May 2012 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4290448
23 February 2011 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3950772
11 February 2010 Internal Structural Exam · DAPI Audit · COI Inspection · MTSA Verification
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3667591
5 May 2009 Annual Inspection · MTSA Verification
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3467287
27 February 2009 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3424705
15 May 2008 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3201151
21 March 2008 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3169141
12 July 2007 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2996017
12 June 2007 Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 2966073
18 May 2007 Administrative Inspection
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 2958712
3 May 2007 Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2921509
6 March 2007 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2880565
4 August 2006 Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2735770
26 April 2006 Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2593995
26 April 2006 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2653077
14 May 2005 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2396670
7 April 2005 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2333165
23 March 2005 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2317899
14 February 2005 MTSA Verification · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2285590
13 January 2005 Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2274549
3 September 2004 MTSA Verification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2185546
16 April 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2045243
23 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978125
8 April 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1756005
30 March 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1799261
11 March 2003 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1749233
3 March 2003 Drydock Extension · Internal Structural Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1751974
19 February 2002 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1487381
10 April 2001 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1384743
26 February 2001 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1362409
16 February 2000 Deficiency Check · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1395391
6 December 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1408414
26 February 1999 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1441451
22 February 1999 Deadweight Survey
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1375655
19 February 1999 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1467105
29 January 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1375627
10 April 1998 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1409882
21 February 1997 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1100970
11 February 1997 Hull Examination · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1385900
15 May 1996 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1083361
20 March 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1078504
21 February 1996 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1451043
23 March 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 841967
24 February 1995 Hull Examination · Inclining Experiment · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1440920

Deficiency record · 50

09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 17 March 2026 Resolved
An exposed hazard, such as gears or rotating machinery, must be protected by a cover, guard, or rail. MI observed rotating shaft on the port side of the engine room was not protected by a cover or guard. Install protective equipment around rotating port shaft.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2026
Resolved 7 April 2026
Resolution: Received picture of repairs-all sat
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 17 March 2026 Resolved
Ceilings, linings, and any furring incidental to their installation in control spaces, passageways, stairways, accommodation spaces and service spaces must be of noncombustible material. MI observed detached ceiling lining in the lazarette. Repair and secure lining.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2026
Resolved 7 April 2026
Resolution: Received picture of repairs-all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 February 2025 Resolved
46CFR 183.10, The general electrical installation shall be installed with metal supports spaced not more than 24 inches apart, and in such a manner as to avoid chafing and other damage. Marine Inspector found spacing greater than 24 inches throughout the engine room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2025
Resolved 18 February 2025
Resolution: Metal supports are installed and within 24 inches.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 February 2025 Resolved
33 CFR 83.33 states a vessel of 20 meters or more in length shall be provided with a bell in addition to a whistle. Marine Inspector identified no bell on board.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2025
Resolved 18 February 2025
Resolution: The proper bell size is onboard
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 April 2024 Resolved
A vessel on a limited coastwise route must carry six red and six orange flares. Vessel was in possession of 05 red flares.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2024
Resolution: Received pictures showing the deficiency corrected.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 24 April 2024 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date charts. Vessel's charts were last updated in 2013.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 May 2024
Resolution: Received pictures showing the deficiency corrected.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 April 2024 Resolved
Penetrations and openings in watertight bulkheads must be watertight. Penetration in the engine room aft bulkhead has separated from bulkhead.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 May 2024
Resolution: Received pictures showing the deficiency corrected.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 May 2022 Resolved
Fire alarm detection system at operating station failed on standby power supply. Repair
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2022
Resolved 10 June 2022
Resolution: Corrected verified by MI.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 11 May 2022 Resolved
Three emergency lighting units at upper deck passenger area SBTD side not operational. Repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2022
Resolved 10 June 2022
Resolution: Corrected; verified by MI.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 11 May 2022 Resolved
Engine room at forward bulkhead overhead light fixture missing it diffuser cover. Repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2022
Resolved 15 June 2022
Resolution: Repaired. Verified by MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 11 May 2022 Resolved
Potable water system in Void space #3; outboard pump unit gauge broken. Repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2022
Resolved 10 June 2022
Resolution: Replaced gauge unit.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 May 2022 Resolved
Upper deck head light fixture over sink missing bulb & diffuser cover. Repair
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2022
Resolved 15 June 2022
Resolution: Repaired; verified by MI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 July 2021 Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date of the COI. Vessel exceeded 3 month interval on 10MAY2020. Vessel is required to complete a satisfactory annual inspection prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2021
Resolution: MI conducted Annual Inspection.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 May 2019 Resolved
Fire hose nozzles shall be made of bronze or same strength and corrosion resistant materials. Both stations equipped with plastic nozzles.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2019
Resolved 9 May 2019
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 7 May 2019 Resolved
Provide updated navigational charts
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2019
Resolved 9 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 May 2019 Resolved
Replace painter line on STBD lifefloat group. Vessel limited to lakes, bays and sounds route.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2019
Resolved 9 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 May 2019 Resolved
Provide 12 distress signals. Vessel limited to lakes, bays and sounds route.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2019
Resolved 9 May 2019
Electrical › Electric Generation Source (service) › Generator
Issued 18 April 2018 Resolved
Clean starboard side generator windings to prevent fire hazards from electrical equipment. Shall be cleaned prior to operation of the generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2018
Resolved 27 April 2018
Resolution: Starboard generator windings were cleaned satisfactorily.
Lifesaving › Lifefloat › Painter
Issued 8 February 2017 Resolved
Provide proper tethering connections for all lifefloats in port side lifefloat stack.
Action required: 705 - Other - as specified
Due 8 February 2017
Resolved 8 February 2017
Resolution: Vessel crew removed wasted tethering loop on topmost lifefloat, re-installed painter lines between middle and topmost lifefloat, all satisfactory.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 8 February 2017 Resolved
Vessel crew shall properly log monthly EPIRB testing, provide approproiate log book for entry.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 February 2017
Resolved 8 February 2017
Resolution: Vessel crew provided EPIRB log book to resume monthly EPIRB testing as required.
Lifesaving › Lifebuoys › Serviceable
Issued 4 May 2016 Resolved
Grab line was deteriorated on 24 inch Ring Lifebuoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 May 2016
Resolved 4 May 2016
Resolution: Replace Ring Lifebuoy, including grab lines.
Electrical › Lighting (emergency) › Lighting Branch Circuit
Issued 5 May 2014 Resolved
Discovered burnt out bulb for emergency lighting, located in between the galley and the aft exit passageway.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 5 May 2014
Resolution: Fixed on the spot through bulb replacement.
Construction/Loadline › Structures › End Bulkhead
Issued 5 May 2014 Resolved
Discovered penetration in watertight bulkhead between the engine room and the void compartment aft of the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 May 2014
Resolution: Item was fixed on the spot by input of foam, making bulkhead watertight.
Documentation › Logs/Records › Drug Test Records
Issued 15 May 2012 Resolved
MIS form not submitted by March 15 as required by 46 CFR part 16.500.
Due 14 June 2012
Resolved 21 May 2012
Resolution: DER emailed proof of MIS submission.
Documentation › Logs/Records › Drug Test Records
Issued 15 May 2012 Resolved
No copy of contract or proof of enrollment in Consortium as required by 46 CFR 16.
Due 14 June 2012
Resolved 21 May 2012
Resolution: DER emailed copy of updated consortium contract.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 21 March 2008 Resolved
Post company's policy/statement for employee assistance program & hotline phone number for drug & alcohol program.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 May 2008
Resolved 15 May 2008
Resolution: Posted.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 15 July 2007 Resolved
Restricted route to no more than 3 miles from shore due to expired EPIRB hydrostatic release.
Due 23 July 2007
Resolved 19 July 2007
Documentation › Logs/Records › Drug Test Records
Issued 18 May 2007 Resolved
Random drug testing was found to not be conducted in accordance with 46 CFR 16.230. Company currently enrolls new employees in its contracted drug testing consortium on a quarterly basis, rather than at the time of hiring.
Due 5 July 2007
Resolved 12 June 2007
Resolution: New employee''s names will be added to the company''s consortium''s random drug testing list prior the employee acting in a safety sensitive position.
Documentation › Logs/Records › Drug Test Records
Issued 18 May 2007 Resolved
Random drug testing was found to not be conducted in accordance with 46 CFR 16.230. Company currently is waiving random drug testing for some employees, based upon their participation in another unaffiliated company.
Due 5 July 2007
Resolved 12 June 2007
Resolution: Random drug tests will no longer be waived.
Fire Fighting › Fire Main › Condition
Issued 3 May 2007 Resolved
Repair leaking firemain piping in engineroom STBD side aft. 46CFR118.310
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 May 2007
Resolved 10 May 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Blower, Centrifugal
Issued 3 May 2007 Resolved
Replace leaking exhaust gasket on port engine. 46CFR119.430
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 May 2007
Resolved 10 May 2007
Fire Fighting › Fire Main › Condition
Issued 26 April 2006 Resolved
Repair to original 3/4" diameter hole in fire main piping located in the laz, STBD side I.A.W. 46 CFR 118.310. Effective temp repairs in place.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 27 April 2006
Resolution: Permanent welding repairs completed to piping system.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 14 February 2005 Resolved
Amend fire control plan to include items listed in 46 CFR 116.530.
Action required: 705 - Other - as specified
Due 14 March 2005
Resolved 7 April 2005
Resolution: Amended fire control plan to include items listed in 46 CFR 116.530.
Documentation › Markings/Placards › Lifejacket Placard
Issued 14 February 2005 Resolved
Provide and post lifejacket placards IAW 46 CFR 122.516
Action required: 705 - Other - as specified
Due 14 March 2005
Resolved 7 April 2005
Resolution: Posted placards IAW 46 CFR 122.516.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 14 February 2005 Resolved
Provide emergency evacuation plan IAW 46 CFR 122.514
Action required: 705 - Other - as specified
Due 14 March 2005
Resolved 7 April 2005
Resolution: Provided emergency evacuation plan IAW 46 CFR 122.514.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 14 February 2005 Resolved
Provide and post station bill IAW 46 CFR 122.514
Action required: 705 - Other - as specified
Due 18 March 2005
Resolved 7 April 2005
Resolution: Posted Station Bill IAW 46 CFR 122.514.
Engineering › Fuel Oil Service System
Issued 19 February 2002 Resolved
Install flame inpingement bowls uder fuel filters for both main diesel engines. LEGACY COMPONENT DESC: Filter
Condition: Unknown
Due 19 March 2002
Resolved 21 March 2002
Resolution: Vessel faxed over receipt of two RACOR Heat Deflector Shields.
Engineering › Freshwater System (jacketwater cooling)
Issued 19 February 2002 Resolved
Support raw water hose on port main diesel engine. Corrected during course of inspection. LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Resolved 19 February 2002
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 19 February 2002 Resolved
Replace cracked and worn raw water hose on starboard generator. Corrected during course of inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 February 2002
Fire Fighting › Miscellaneous Items
Issued 19 February 2002 Resolved
Provide Fire Control Plan per 46 CFR 16.530.
Due 19 March 2002
Resolved 1 April 2002
Resolution: Received fax copy of fire control plan.
Accommodation/Occupational Safety › Medical/First Aid
Issued 19 February 2002 Resolved
Replace expired items in first aid kit.
Due 19 March 2002
Resolved 21 March 2002
Resolution: Vessel faxed receipt to show purchase of new items.
Documentation
Issued 16 February 2000 Resolved
Provide copy of 46CFR Subchapter K on vessel.
Condition: Unknown
Due 23 March 2000
Resolved 23 March 2000
Lifesaving
Issued 19 February 1999 Resolved
Label number of children's life jackets to match acual number on board (31).
Condition: Unknown
Due 18 March 1999
Resolved 19 March 1999
Lifesaving
Issued 19 February 1999 Resolved
Install 406 Mhz EPIRB in float free arrangement/automatic operation.
Condition: Unknown
Due 18 March 1999
Resolved 19 March 1999
Engineering
Issued 19 February 1999 Resolved
Provide appropriate connections for flexible hose sections for both generators to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 18 March 1999
Resolved 19 March 1999
Navigation
Issued 19 February 1999 Resolved
Provide updated local charts.
Condition: Unknown
Due 18 March 1999
Resolved 19 March 1999
Documentation
Issued 29 January 1999 Resolved
After the replacement of the engines, the vessel is restricted to a Lakes, Bays and Sounds route route until the completion and approval by the MarineSafety Center, of a deadweight survey.
Condition: Unknown
Due 29 January 1999
Resolved 29 January 1999
Lifesaving
Issued 21 February 1996 Resolved
Provide pressure vessels meeting ASME standards as per 46 CFR Subchapter F.Remove from service the unapproved pressure vessels used for the horn and beverage service.
Condition: Unknown
Due 21 February 1996
Resolved 21 February 1996
Lifesaving
Issued 21 February 1996 Resolved
Provide primary lifesaving for 153 persons or 50% of total number of persons allowed onboard. Maximum passenger capacity restricted to 259 persons until additional primary lifesaving is provided.
Condition: Unknown
Due 21 February 1996
Resolved 21 February 1996
Lifesaving
Issued 21 February 1996 Resolved
Provide a properly sized relief valve for all pressure vessels.
Condition: Unknown
Due 21 February 1996
Resolved 21 February 1996

Casualty record · 1

14 May 2005Routine · role: Involved in a Marine Casualty · 1 injured · activity 2396670
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.