Records from 1994 to 2019. Most recent: inspection, 10 September 2019.
Inspection history · 57
10 September 2019
Administrative Inspection · In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6808251
27 March 2018
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6379587
16 October 2017
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6286087
26 June 2012
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4345080
22 February 2011
Internal Structural Exam · Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3950208
26 January 2011
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3933756
12 October 2010
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3872215
9 March 2010
Re-Inspection · MARPOL Annex VI Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3685507
10 July 2009
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3530076
20 February 2009
Drydock Exam · COI Inspection · Construction Oversight · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3415352
8 September 2008
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3320249
2 April 2007
Internal Structural Exam · Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2900158
11 September 2006
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2775614
11 July 2006
COI Inspection · MTSA/ISPS Verification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2709003
16 June 2006
MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2681369
7 June 2006
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2699731
21 February 2006
Hull Examination · Internal Structural Exam
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2598400
21 October 2005
ISM Oversight
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2519137
27 July 2005
COI Inspection · Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2441653
3 May 2005
Internal Structural Exam · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2345921
29 April 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2345558
28 April 2005
Administrative Inspection
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2344882
2 March 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2302237
28 September 2004
ISM Oversight
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2207225
19 July 2004
MTSA/ISPS Verification
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2137904
30 June 2004
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2116263
23 February 2004
Hull Examination · COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2011343
7 July 2003
COI Inspection · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1837998
17 June 2003
Administrative Inspection
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1820688
18 June 2002
Hull Examination · COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1601138
28 February 2002
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1490725
3 July 2001
Hull Examination · COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1458909
22 June 2000
Hull Examination · COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1468982
19 June 2000
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1053434
5 April 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 87892
29 June 1999
Hull Examination · COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1401210
8 April 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 760820
30 March 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 204331
16 July 1998
COI Inspection · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1130541
31 July 1997
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 65668
23 July 1997
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 780179
16 July 1997
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1115781
11 January 1997
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5878
25 September 1996
Damage Survey
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 829389
26 July 1996
Hull Examination · COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1084467
30 April 1996
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1414639
29 November 1995
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1416211
21 September 1995
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1367443
16 August 1995
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 873431
11 August 1995
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1186157
2 August 1995
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1186155
12 May 1995
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1226960
5 April 1995
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 840856
12 January 1995
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 840359
29 November 1994
Initial Certification
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 862543
9 November 1994
Inclining Experiment
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 862544
17 October 1994
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1179208
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 September 2019
No resolution recorded
Complete credit renewal Certificate of inspection.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 September 2019 — due date passed with no resolution recorded
Construction/Loadline › Hull › Bottom Plating
Issued 16 October 2017
Resolved
Clad weld areas marked, due to pitting of steel place, both port and starboard side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2017
Resolution: All areas were welded, all sat
Construction/Loadline › Hull › Weld
Issued 16 October 2017
Resolved
Repair/re-weld stbd chine weld near frame 40 (Tank Compartment #2 - stbd fuel wing tank)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2017
Resolution: Welding completed, all sat.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 16 October 2017
Resolved
Pull both shafts, replace in kind, both shafts are to be condemned due to corrosion.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2017
Resolution: Both shafts were replaced in kind.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 16 October 2017
Resolved
Replace both cutlass bearings for each shaft replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2017
Resolution: All bearings replaced in kind.
Engineering › Thrusters › Tunnel
Issued 16 October 2017
Resolved
Address pitting corrosion in bow thruster tunnel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2017
Resolution: Coated bow thruster tunnel with BALZONA marine adhesive to protect, all sat.
Construction/Loadline › Structures › Superstructure
Issued 16 October 2017
Resolved
Replace stanchion pipes on swim platform, replace all in kind.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2018
Resolution: Replaced all stanchions in kind and relayed fiber glass for section of swim platform.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 16 October 2017
Resolved
Centerline compartment aft of forepeak, re-weld weld on aft bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2017
Resolution: Weld completed, all sat.
Engineering › Bilge Water Management System › Piping
Issued 16 October 2017
Resolved
Repair hole in ballast pipe in Lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 November 2017
Resolution: Repaired hole, inserted mechanical plug, with threaded fitting, all sat.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 16 October 2017
Resolved
Repair vent pipes for fuel tank on stbd side as original.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2018
Resolution: Repaired vent pipes for fuel tank on stbd side as original.
Construction/Loadline › Hull › Weld
Issued 16 October 2017
Resolved
Re-weld two marked areas on hull for washed out welds, gouge out and re-weld.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 October 2017
Resolution: Welds completed, all sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 26 June 2012
No resolution recorded
Prior to the vessel getting underway fire systems must be serviced.
Action required: 705 - Other - as specified
Due 26 June 2013 — due date passed with no resolution recorded
Lifesaving › Inflatable Liferafts › Servicing
Issued 26 June 2012
No resolution recorded
Prior to the vessel getting underway life rafts must be serviced.
Action required: 705 - Other - as specified
Due 26 June 2012 — due date passed with no resolution recorded
Documentation › Certificates/Documents › Certificate of Inspection
Issued 26 June 2012
No resolution recorded
Prior to carrying passengers the vessel must complete a satisfactory coast guard re-inspection.
Action required: 705 - Other - as specified
Due 26 June 2013 — due date passed with no resolution recorded
Construction/Loadline › Structures › Superstructure
Issued 26 June 2012
No resolution recorded
Properly repair the broken window on the 2nd deck aft door leading to weather deck.
Action required: 705 - Other - as specified
Due 26 June 2012 — due date passed with no resolution recorded
Communications › Alarms/Indicators › Fire Alarm
Issued 26 June 2012
No resolution recorded
Properly repair the fire detection system.
Action required: 705 - Other - as specified
Due 26 June 2012 — due date passed with no resolution recorded
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 9 March 2010
Resolved
Repair or replace time delay for engine room CO2 system and demonstrate valid test in presence of Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2010
Resolution: New time delay installed and tested.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 9 March 2010
Resolved
Replace missing insulation in the miscellaneous stores space.
Action required: 705 - Other - as specified
Due 16 March 2010
Resolved 17 March 2010
Resolution: Insulation replaced
Engineering › Bilge Water Management System › Valve
Issued 9 March 2010
Resolved
Repair or replace check valves in both bilge pumps in the tank compartment.
Action required: 705 - Other - as specified
Due 16 March 2010
Resolved 17 March 2010
Resolution: Valves were cleaned and tested.
Engineering › Diesel Engine (propulsion-reduction gear) › Bearing
Issued 9 March 2010
Resolved
Address excessive water flow from stbd side shaft gland.
Action required: 705 - Other - as specified
Due 16 March 2010
Resolved 17 March 2010
Resolution: Shaft gland was tightened.
Electrical › Electrical Distribution System (service) › Conductor
Issued 9 March 2010
Resolved
Address dead end wire for ballast pump in tank compartment as discussed with marine inspector.
Action required: 705 - Other - as specified
Due 16 March 2010
Resolved 17 March 2010
Resolution: Wire was properly secured.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 9 March 2010
Resolved
Replace missing junction box cover in lazarette as discussed with Marine Inspector.
Action required: 705 - Other - as specified
Due 16 March 2010
Resolved 17 March 2010
Resolution: Cover was replaced.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 8 June 2009
Resolved
33U.S.C.1321(j)(5)(G)-The vessel owner/operator has not provided certification ensuring that response resources are capable of responding to the maximum extent practicable, to a worst case discharge.
33U.S.C.1321(j)(5)(D)(i)-Due to the publication of the tech amendments to 33 CFR Part 3, the COTP zone names need to be updated to reflect this amendment.
Due 8 July 2009
Resolved 17 August 2009
Resolution: Plan holder addressed outstanding deficiencies and amended NTVRP Control #05948 accordingly. Vessel issued interim operating authorization expiring 8/17/11.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 8 June 2009
Resolved
33U.S.C.1321(j)(5)(D)(i)-It is recommended that the NTVRP Control #05948 include the IMO number for the vessels and include the GT ITC of 667 tons since reviewed nontank vessels have an ITC over 400.
Due 8 July 2009
Resolved 17 August 2009
Resolution: Plan holder addressed outstanding deficiencies and amended NTVRP Control #05948 accordingly. Vessel issued interim operating authorization expiring 8/17/11.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 20 February 2009
Resolved
Prove proper operation of oily water separator
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2009
Resolution: Disconnected sucton side of OWS and capped piping to prevent continued operation. Vessel has the means to contain oily mixtures on board and have removed via reception facility.
Construction/Loadline › Structures › Superstructure
Issued 11 July 2006
Resolved
Make permanent repairs to cracks on 2nd deck window frames, port & stbd, to the satisfaction of classification society.
Action required: 705 - Other - as specified
Due 29 January 2007
Resolved 20 October 2006
Resolution: Verified w/ ABS Surveyor that cracks were drill-stopped, vee''d out and rewelded. ABS witnessed hose test of welds and windows.
Fire Fighting › Means of Escape › Corridors
Issued 27 July 2005
Resolved
Ensure escape from passenger cabins is readily apparent.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2005
Engineering › Steering Gear System › Linkage
Issued 27 July 2005
Resolved
Ensure emergency steering system engages & disengages properly.
Action required: 703 - Prior to bunkering operations
Resolved 4 August 2005
Engineering › Bilge Water Management System › Pump
Issued 27 July 2005
Resolved
Perform operational test of aft steering compartment bilge pump
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2005
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Nozzle, Injection (fuel injection)
Issued 27 July 2005
Resolved
Properly repair F/O leak from #3 injector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2005
Communications › Alarms/Indicators › Bilge Alarm
Issued 3 May 2005
Resolved
Provide a more suitable wire run for bilge high level alarms, current installation of wire and junction boxes located within port ballast tanks. Indication of water damage in junction box is evident.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2005
Resolved 15 August 2005
Construction/Loadline › Penetrations › Pipe Flange
Issued 7 July 2003
Resolved
Starboard side seachest iwo of lazzerette wasted to 35% replace same at next haulout in November. LEGACY COMPONENT DESC: Seachest for starboard side ballast and A/C
Condition: Improper/Lack of Maintenance
Due 30 November 2003
Resolved 5 March 2004
Resolution: Starboard ballast and A/C sea chest replaced sat.
System not recorded
Issued 3 July 2001
Resolved
INSTALL AN AUDIBLE/VISUAL BILGE LEVEL ALARM AT THE OPERATING STATION THAT MONITORS ALL SPACES CAPABLE OF INDICATING MORE THAN ONE FAULT AND WHERE THEACCEPTANCE OF ANY ALARM WILL NOT INHIBIT ANOTHER.
Condition: Unknown
Due 22 October 2001
Resolved 28 February 2002
Resolution: Witness satisfactory test of monitor alarm system.
System not recorded
Issued 3 July 2001
Resolved
UNTIL TR1 IS CLEAR- UPON A SINGLE BILGE ALARM CONDITION THE SPACE MUST BE TENDED TO IN ORDER TO CLEAR THAT ALARM. UNTIL THAT SINGLE ALARM IS CLEAREDROMING WATCH MUST MAKE OBSERVATION OF BILGE ALARM PANEL IN E-GEN RM EVERY HALF HOUR TO IDENTIFY A SECOND ALARM CONDITION AND REPORT IT TO THE MASTER
Condition: Unknown
Due 22 October 2001
Resolved 28 February 2002
Unknown
Issued 16 July 1998
Resolved
REMOVE FIRE DOOR CLOSURE RESTRIANTS AT GALLEY.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Unknown
Issued 16 July 1998
Resolved
INSTALL EXHAUST WRAP ON STBD ENGING EXHAUST PIPE.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Unknown
Issued 16 July 1998
Resolved
INSTALL RIGID GUARD FOR DAY TANK SIGHT GLASS.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Lifesaving
Issued 16 July 1998
Resolved
REPLACE UNSERVICABLE RING BUOY.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Unknown
Issued 16 July 1998
Resolved
LABEL ENGINE RO0M VENTILATION SHUTDOWN AT PORT AND STBD PASSAGEWAYS.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Navigation
Issued 16 July 1998
Resolved
REPLACE STBD RUDDER AND RUDDER POST.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Construction/Loadline
Issued 26 July 1996
Resolved
SUBMIT REVISED BALLAST SYSTEM PIPING DIAGRAM REFLECTING THE IN-LINE BALLASTPUMPS. DRAWINGS TO BE SUBMITTED TO MSC AND MSO PROVIDENCE.
Condition: Unknown
Due 30 August 1996
Resolved 4 September 1996
Construction/Loadline
Issued 26 July 1996
Resolved
SUBMIT REVISED ELECTRICAL DIAGRAM REFLECTING THE INSTALLATION OF THE IN-LINE BALLAST PUMPS.
Condition: Unknown
Due 30 August 1996
Resolved 4 September 1996
Construction/Loadline
Issued 26 July 1996
Resolved
PRIOR TO OPERATION OF NEW BALLAST SYSTEM PUMPS WITH PASSENGERS ON BOARD, SUBMIT NEW BALLASTING OPERATION PROCEDURE FOR APPROVAL AND HAVE THE ACTUAL OPERATION WITNESSED BY A USCG MARINE INSPECTOR.
Condition: Unknown
Due 26 July 1996
Resolved 30 July 1996
Construction/Loadline
Issued 26 July 1996
Resolved
SUBMIT REVISED BALLASTING PROCEDURE ENCOMPASSING THE USE OF THE BALLAST PUMPS IN LIEU OF FIRE HOSES FOR TOPPING OFF THE BALLAST TANKS.
Condition: Unknown
Due 30 August 1996
Resolved 4 September 1996
Lifesaving
Issued 26 July 1996
Resolved
STENCIL THE EMERGENCY FLARES CONTAINER IN ACCORDANCE WITH THE REQUIREMENTS OF 46 CFR 185.614. "DISTRESS SIGNALS" NOT LESS THAN .5" LETTERS.
Condition: Unknown
Due 31 July 1996
Resolved 30 July 1996
Fire Fighting
Issued 26 July 1996
Resolved
PROVIDE PROOF OF SERVICING OF PORTABLE FIRE EXTINGUISHER LOCATED IN EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 31 July 1996
Resolved 30 July 1996
Electrical
Issued 26 July 1996
Resolved
HARDWIRE THE PORT SHAFT LOG PUMP.
Condition: Unknown
Due 31 July 1996
Resolved 30 July 1996
Accommodation/Occupational Safety
Issued 26 July 1996
Resolved
MAKE REPAIRS TO THE HOT WATER TANK PIPING FITTING AT THE TOP OF THE TANK.
Condition: Unknown
Due 31 July 1996
Resolved 30 July 1996
Accommodation/Occupational Safety
Issued 11 August 1995
Resolved
FORWARDMOST CREW BERTHING ARRANGEMENT IS UNSAT ASCURRENT ARRANGEMENT FOR 3 PEOPLE DUE TO INABILITY OF PERSON OCCUPYING UPPER RACK TO GET IN UPPER RACKWITHOUT STEPPING ON LOWER RACK. MAKE UPPER RACK EASILY ACCESSIBLE OR DESIGNATE A PASSENGER CABIN AS ADDITIONAL CREW BERTHING.
Condition: Unknown
Due 3 September 1995
Resolved 11 August 1995
Fire Fighting
Issued 11 August 1995
Resolved
PROVIDE PROOF OF PROPER OPERATION OF FIRE DETECTION PANEL AND ASSOCIATED SENSORS.
Condition: Unknown
Due 3 September 1995
Resolved 1 September 1995
Fire Fighting
Issued 11 August 1995
Resolved
PROVIDE PROOF OF PROPER OPERATION OF FIXED CO2 SYSTEM BOTTLE NOZZLES.
Condition: Unknown
Due 3 September 1995
Resolved 1 September 1995
Fire Fighting
Issued 11 August 1995
Resolved
CONDUCT FIREFIGHTING/MAN OVERBOARD, ETC DRILLS IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 3 September 1995
Resolved 1 September 1995
Electrical
Issued 11 August 1995
Resolved
PROVIDE LABELS TO BREAKERS LOCATED IN PILOTHOUSE AS NEEDED.
Condition: Unknown
Due 3 September 1995
Resolved 1 September 1995
Navigation
Issued 11 August 1995
Resolved
MAKE COMPASS LIGHT OPERATIONAL.
Condition: Unknown
Due 3 September 1995
Resolved 1 September 1995
Lifesaving
Issued 11 August 1995
Resolved
MAKE PERMANENT REPAIRS TO EPIRB COVER.
Condition: Unknown
Due 3 September 1995
Resolved 1 September 1995
Lifesaving
Issued 11 August 1995
Resolved
PROPERLY SECURE LIFERAFTS (3) PAINTER LINES TO VESSEL.
Condition: Unknown
Due 3 September 1995
Resolved 1 September 1995
Construction/Loadline
Issued 11 August 1995
Resolved
TEST BILGE LEVEL MONITOR LIGHTS IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 3 September 1995
Resolved 1 September 1995