MAURY USCG vessel records Sign in
← All vessels

MARY E

MARY E is a 1906 passenger vessel (inspected). The Coast Guard has recorded 62 inspections since 1985, most recently in April 2026, along with 112 deficiencies — 4 with no resolution recorded —, 1 operational control, 1 with no removal date recorded and 5 casualty investigations between 2009 and 2021.

Records from 1985 to 2026. Most recent: inspection, 17 April 2026.

Built
1906
Last inspected
17 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

WDD7873
Flag
UNITED STATES
367192450
Maury page id
psix-41706

Inspections, by type

…with no type recorded10
…past their stated due date4
Years with a record 35 calendar years (1985–2026)
The 62 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)46.4 ft × 14.0 ft × 5.8 ft
Registered tonnagegross 16 / net 5
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderUNKNOWN · BATH, ME, UNITED STATES · built 1906
Hull materialWood
PropulsionCombination Types
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBATH, ME
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it5 - Regulatory (Subpart C or D), Net Ton
16 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK3025MMSI 367192450 · active · compulsorily equipped · granted 29 May 2018, expires 29 May 2028
WDD7873MMSI 367192450 · expired · compulsorily equipped · granted 6 June 2007, cancelled 12 August 2017
WCZ2182MMSI not assigned · expired · voluntarily equipped · granted 27 April 1999, cancelled 27 June 2009
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 62

17 April 2026 Drydock Exam · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8352507
12 April 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7895952
19 April 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7439198
2 August 2021 Damage Survey
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7275188
30 July 2021 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7275064
30 July 2020 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7020194
20 April 2020 Internal Structural Exam · Hull Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6941840
10 July 2019 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6744812
7 August 2017 COI Inspection · Hull Examination · Examination of Repairs · Deficiency Check · DAPI Audit
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6233367
29 August 2016 Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5989873
15 October 2015 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5743121
28 September 2015 Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5731391
24 October 2014 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5011594
29 August 2014 Drydock Extension · Hull Examination · Internal Structural Exam · Deficiency Check · Annual Inspection · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4968842
14 February 2012 Drydock Exam · Internal Structural Exam · In-Service Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4244874
19 September 2011 In-Service Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4155747
18 September 2011 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4149305
17 August 2011 Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4117525
18 February 2011 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3947852
6 January 2010 Inclining Experiment
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3661933
5 July 2009 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3556466
3 October 2008 Type not recorded
No type recorded · Station New London · USCG Northeast District (CGD-NE) · Activity 3338351
31 October 2007 Plan Review "T" Boat · Hull Examination · Examination of Repairs · Deficiency Check · Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3090739
4 June 2007 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2950958
27 July 2006 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2725807
4 April 2006 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2616101
25 April 2005 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2341999
10 June 2004 MARPOL Annex V Examination · Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2091173
13 November 2003 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1946150
14 April 2003 MARPOL Annex V Examination · Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1771923
17 July 2002 Internal Structural Exam · Damage Survey · Hull Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1763239
16 April 2001 Re-Inspection · Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1456984
12 May 2000 COI Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1406720
22 October 1999 Deficiency Check · Plan Review "T" Boat
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1411885
20 May 1999 MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1471864
13 April 1999 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1446714
8 March 1999 Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 801223
10 July 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1375432
10 July 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1375434
20 April 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 789597
1 December 1997 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1437353
31 July 1997 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 784284
23 May 1997 MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1109205
22 May 1996 MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1085152
4 January 1996 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 872019
19 January 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1176030
16 December 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1178710
30 June 1994 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1170249
20 June 1994 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 871331
26 April 1994 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 106869
18 April 1994 COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 860056
30 October 1992 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1136103
27 April 1992 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 953739
24 October 1991 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 941582
16 October 1990 Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 915934
12 April 1990 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1230490
18 July 1989 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1202515
18 May 1989 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1345595
13 March 1989 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 886969
27 October 1987 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1327275
15 September 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1005154
25 November 1985 Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 995391

Deficiency record · 112

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 July 2020 No resolution recorded
Provide Preventative Maintenance Plan for sail rigging IAW NVIC 02-16 in addition to sail rigging log or provide third party survey on sail rigging IAW NVIC 02-16.
Due 30 September 2020 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 30 July 2020 Resolved
Install life float IAW NVIC 1-83. Additionally secure oars to life float.
Due 6 August 2020
Resolved 21 August 2020
Resolution: Life float properly installed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 July 2020 No resolution recorded
Properly mount mast head light IAW COLREGS. Light is impeded by topmast. Prior to sailing in low visibility.
Action required: 705 - Other - as specified
Due 30 July 2020 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 July 2020 No resolution recorded
Install smoke detectors with proper approvals IAW 46CFR181.450. Must meet UL 217 and be listed as a "Single Station Smoke detector- also suitable for use in a Recreational Vehicle.
Due 30 August 2020 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 July 2020 No resolution recorded
Fill in holes in vapor barriers/watertight bulkheads. Cable pass thru in engine room needs filled in.
Due 6 August 2020 — due date passed with no resolution recorded
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 July 2019 Resolved
CHARTS NOT CURRENT NOR CORRECTED; REPLACE WITH CURRENT OR CORRECTED CHARTS. 46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 6 August 2019
Resolution: Charts provided.
Navigation › Piloting/Steering › Magnetic Compass
Issued 29 August 2016 Resolved
Repair compass light.
Action required: 705 - Other - as specified
Due 29 September 2016
Resolved 28 September 2016
Resolution: Compass light replaced.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 29 August 2016 Resolved
Provide 2 Adult PFD, vessel is restricted to carriage if 26 total adults.
Action required: 705 - Other - as specified
Due 29 September 2016
Resolved 28 September 2016
Resolution: Purchased additional life jackets.
Communications › Radio Communications › EPIRB
Issued 29 August 2016 Resolved
Provide EPIRB.
Action required: 705 - Other - as specified
Due 29 September 2016
Resolved 14 June 2018
Resolution: New EPIRB has been installed and verified
Lifesaving › Hand Flares › Quantity
Issued 29 August 2016 Resolved
Provide 6 additional distress signals, vessel is restricted to Lakes, Bays, and Sounds route until item are provided.
Action required: 705 - Other - as specified
Due 29 September 2016
Resolved 14 June 2018
Resolution: All required flares have been added on board.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 29 August 2016 Resolved
Provide 60ft 5/16 life line
Action required: 705 - Other - as specified
Due 29 September 2016
Resolved 28 September 2016
Resolution: Purchased new 60' 5/16th" lifeline for the ring buoy.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 29 August 2016 Resolved
Tighten linkange on engine shutdown solenoid.
Action required: 705 - Other - as specified
Due 29 September 2016
Resolved 28 September 2016
Resolution: Operator replaced linkage with a tigher linkage.
Engineering › Steering Gear System › Ram Seal
Issued 29 August 2016 Resolved
Tighten shaft packing gland
Action required: 705 - Other - as specified
Due 29 September 2016
Resolved 28 September 2016
Resolution: Packing gland was tightened. The packing gland did not leak at the time of the re-inspection.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 August 2016 Resolved
Properly bundle electrical cables in the engine room.
Action required: 705 - Other - as specified
Due 29 September 2016
Resolved 28 September 2016
Resolution: Cables were rebundled using proper ties.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 August 2016 Resolved
Remove dead end wiring in the Captain's Cabin.
Action required: 705 - Other - as specified
Due 29 September 2016
Resolved 28 September 2016
Resolution: Dead end wiring was removed.
Sail Rigging › Deck Hardware › Shackles
Issued 29 August 2016 Resolved
Replace two damage blocks, 1 damaged gaff boom, and 1 mizzen gaff boom.
Action required: 705 - Other - as specified
Due 29 September 2016
Resolved 28 September 2016
Resolution: Both booms were replaced.
Sail Rigging › Running Rigging › Topping Lifts/Attachments
Issued 29 August 2016 Resolved
Provide either preventative maintenance plan or third party rig inspection in accordance with NVIC 02-16.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2018
Resolution: Rig inspection plan has been completed.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 28 September 2015 Resolved
Repair audible alarm for engine room fire boy.
Condition: Improper/Lack of Maintenance
Due 6 October 2015
Resolved 6 October 2015
Resolution: ALarm repaired.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 28 September 2015 Resolved
replace retro-reflective tape on child PFDs as needed.
Due 6 October 2015
Resolved 6 October 2015
Resolution: Retro installed.
Fire Fighting › Fire Bucket › Quantity
Issued 28 September 2015 Resolved
Provide 1 additional fire bucket with lanyard.
Condition: Improper/Lack of Maintenance
Due 6 October 2015
Resolved 6 October 2015
Resolution: Firebucket provided.
Construction/Loadline › Hull › Transverse Frame
Issued 28 September 2015 Resolved
Provide statement and repair proposal from shipwright concerning split hanging knee in salon, port side.
Condition: Improper/Lack of Maintenance
Due 6 October 2015
Resolved 6 October 2015
Resolution: Statement from shipwright provided.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 28 September 2015 Resolved
Replace wasted fire extinguisher bracket in salon.
Condition: Improper/Lack of Maintenance
Due 6 October 2015
Resolved 6 October 2015
Resolution: New bracket installed.
Construction/Loadline › Hull › Transverse Frame
Issued 28 September 2015 Resolved
Repair split lodging knee located in the port side of the main salon.
Condition: Improper/Lack of Maintenance
Due 1 April 2016
Resolved 14 June 2018
Resolution: Vessel has had an entire retrofit and all knees have been replaced.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 November 2014 Resolved
Renew eyewash in first aid kit.
Due 8 November 2014
Resolved 8 November 2014
Resolution: Eyewash renewed.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 8 October 2014 Resolved
Repair audible and visual alarm for E/R fire boy system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2014
Resolution: Alarms repaired.
Communications › Alarms/Indicators › Bilge Alarm
Issued 8 October 2014 Resolved
Repair high bilge audible and visual alarm at operator's station.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2014
Resolution: Alarm repaired.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 8 October 2014 Resolved
Provide 18 Adult Type I PFDs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2014
Resolution: PFDs provided.
Documentation › Markings/Placards › Lifejacket Placard
Issued 8 October 2014 Resolved
Post life jacket donning placard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2014
Resolution: Placard posted.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 8 October 2014 Resolved
Provide operating instructions for E/R fire boy.
Due 8 November 2014
Resolved 24 October 2014
Resolution: Instructions provided.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 8 October 2014 Resolved
Renew fire boy manual release 'T" handle.
Due 8 November 2014
Resolved 24 October 2014
Resolution: Handle replaced.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 8 October 2014 Resolved
Provide tamper seal for Fire Boy manual pull.
Due 8 November 2014
Resolved 24 October 2014
Resolution: Tamper seal installed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 8 October 2014 Resolved
Renew mounting bracket for B-I fire extinguisher in captain cabin.
Due 8 November 2014
Resolved 10 October 2014
Resolution: Bracket replaced.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 8 October 2014 Resolved
Provide original COD and COI onboard vessel.
Due 8 November 2014
Resolved 23 April 2015
Resolution: Items cleared at 2015 Hull Exam.
Navigation › Piloting/Steering › Magnetic Compass
Issued 8 October 2014 Resolved
Provide light for magnetic compass.
Due 8 November 2014
Resolved 24 October 2014
Resolution: Compass light repaired.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 8 October 2014 Resolved
Repair main engine RPM gauge.
Due 8 November 2014
Resolved 24 October 2014
Resolution: Gauge repaired.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 October 2014 Resolved
Provide 5/16" line (3'-6') bouyant line with clip for ring bouy water light.
Due 8 November 2014
Resolved 10 October 2014
Resolution: Line installed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 8 October 2014 Resolved
Provide high bilge level alarm for main salon compartment. To be installed at next yard period.
Action required: 705 - Other - as specified
Due 15 April 2015
Resolved 23 April 2015
Resolution: Item cleared during 2015 Hull Exam.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 15 September 2014 Resolved
Vessel is restricted to PROTECTED waters only until permanent repairs are completed to the transom and the open planking seams on the starboard side forward, above the waterline, are closed.
Action required: 705 - Other - as specified
Due 15 April 2015
Resolved 23 April 2015
Resolution: Items repaired at 2015 Hull Exam.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 29 August 2014 Resolved
Vessel missed its required Hull/ISE. ISE conducted. Vessel allowed to operate through 07SEP2014. Must be made available for dry dock inspection and not allowed to carry passengers after 08SEP2014
Action required: 705 - Other - as specified
Due 8 September 2014
Resolved 9 September 2014
Resolution: Credit hull and IS exams completed on 09SEP14.
Construction/Loadline › Hull › Bottom Plating
Issued 14 February 2012 Resolved
Remove 4 planks outboard from keel on port & stbd bottom to allow further examination. (N.B. 8 port & 5 stbd removed.)
Action required: 705 - Other - as specified
Resolved 18 July 2012
Resolution: Completed.
Construction/Loadline › Hull › Keel
Issued 14 February 2012 Resolved
Remove planking IWO lower stem to allow further examination.
Action required: 705 - Other - as specified
Resolved 18 July 2012
Resolution: completed
Construction/Loadline › Hull › Transverse Frame
Issued 14 February 2012 Resolved
Renew lower futtocks port & stbd for the first forward 14 frames.
Action required: 705 - Other - as specified
Resolved 18 July 2012
Resolution: completed 17 frames
Construction/Loadline › Hull › Keel Plate
Issued 14 February 2012 Resolved
Renew forward section of keelson from section renewed aft at previous drydocking to stem.
Action required: 705 - Other - as specified
Resolved 18 July 2012
Resolution: Completed stem to fr 17.
Construction/Loadline › Structures › Superstructure
Issued 14 February 2012 Resolved
MASTS: Unstep masts & examine condition of masts & standing riging.
Action required: 705 - Other - as specified
Resolved 22 February 2012
Resolution: Mast blocked on saw horses. (See narritive w/ activity.)
Construction/Loadline › Hull › Side Shell
Issued 14 February 2012 Resolved
Develop a new six year maintenance plan giving consideration to hull caulking, deck caulking and conditions observed during U/W observations post drydock and again after vessel has been in service for two months.
Action required: 705 - Other - as specified
Due 31 October 2012
Resolved 10 September 2014
Resolution: New long term plan submitted to Sector LIS OCMI.
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 14 February 2012 Resolved
Renew rotted/fractured engine bed on the stbd side of the auxiliary diesel.
Action required: 705 - Other - as specified
Due 31 August 2012
Resolved 15 August 2012
Resolution: Repaired with an aluminum foundation secured to the vessel''s transverse framing.
Documentation › Certificates/Documents › Stability Letter
Issued 14 February 2012 Resolved
Provide a stability letter. The vessel may not carry passengers beyond a Rivers Route until she obtains a valid stability letter.
Action required: 705 - Other - as specified
Resolved 30 August 2012
Resolution: Vessel received SST and stability Letter issued.
Engineering › Reduction Gearing/Clutches › Clutch Plate
Issued 14 February 2012 Resolved
Check clutch / reverse gear remote control linkage to ensure that the operating station is capable of moving the lever on the gear control valve fully stop to stop for forward to reverse.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2012
Resolved 19 August 2012
Sail Rigging › Stays/Shrouds › Turnbuckles and Toggles
Issued 14 February 2012 Resolved
After necessary adjustments are completed mouse or use some other acceptable means the turnbuckles and rigging.
Action required: 705 - Other - as specified
Due 31 August 2012
Resolved 19 August 2012
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 14 February 2012 Resolved
Adjust shaft log packing gland.
Action required: 705 - Other - as specified
Due 31 August 2012
Resolved 28 July 2012
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 17 August 2011 Resolved
Prove enrollment of all crew in drug testing program.
Action required: 705 - Other - as specified
Due 24 August 2011
Resolved 15 September 2011
Resolution: All members are now enrolled.
Documentation › Certificates/Documents › FCC SSL
Issued 17 August 2011 Resolved
Provide FCC Safety Certificate
Action required: 705 - Other - as specified
Due 1 September 2011
Resolved 8 October 2013
Resolution: Vessel does not need FCC safety certificate becasue of rivers route.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 17 August 2011 Resolved
Address corrosion on exhaust riser (next drydock).
Action required: 705 - Other - as specified
Due 30 November 2011
Resolved 19 August 2012
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 17 August 2011 Resolved
Provide hanger on wet exhaust where missing.
Action required: 705 - Other - as specified
Due 24 August 2011
Resolved 23 August 2011
Resolution: Attended vessel. Hanger installed.
Fire Fighting › Ventilation Systems › Ducts
Issued 17 August 2011 Resolved
Provide means to close/block engine room ventilation.
Action required: 705 - Other - as specified
Due 24 August 2011
Resolved 23 August 2011
Resolution: Attended vessel. PVC plugs are now provided.
Engineering › Fuel Oil Service System › Valve, Control
Issued 17 August 2011 Resolved
Prove operation of emergency fuel shutoff.
Action required: 705 - Other - as specified
Due 18 August 2011
Resolved 17 August 2011
Resolution: Corrected during visit.
Fire Fighting › Ventilation Systems › Ducts
Issued 17 August 2011 Resolved
Repair/Replace crushed ventilation duct in engine room.
Action required: 705 - Other - as specified
Due 24 August 2011
Resolved 23 August 2011
Resolution: Attended vessel. New duct work installed.
Construction/Loadline › Structures › Machinery Space Opening
Issued 17 August 2011 Resolved
Plug hole (wire run) in forward engine room bulkhead.
Action required: 705 - Other - as specified
Due 24 August 2011
Resolved 23 August 2011
Resolution: Attended vessel. Hole is now sealed.
Stability › Incline Test › General
Issued 29 February 2008 Resolved
Perform an intact stability test.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 6 January 2010
Resolution: Performed by Erica Hansen, N.A. Evaluation of data by MSC pending after submittal to MSD by [name withheld] on 6.4.10 & forwarded to MSC on 6.7.10.
Construction/Loadline › Hull › Hull Plating
Issued 31 October 2007 Resolved
Repair loose planks port side midship as marked.
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 30 April 2008
Resolution: Extensive replacements completed of internals & planking fastened to renewed frames, caulked & painted.
Construction/Loadline › Hull › Hull Plating
Issued 31 October 2007 Resolved
Repair butts as marked port and stbd... multiple places aprox 4 on each side.
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 30 April 2008
Resolution: Further exam showed frames required renewal. Approximately 60% of hull frames renewed.
Construction/Loadline › Hull › Keel
Issued 31 October 2007 Resolved
Repair leak IWO stern post.
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 30 April 2008
Resolution: Reaved out, fx stopwaters renewed, planks refastened & caulking replaced,
Engineering › Thrusters › Shaft
Issued 31 October 2007 Resolved
There is nothing for mast and rigging in the MISLE menu. Main mast upper end presents w/ rotted section IWO cross-tie and section above. Propose and complete repairs.
Action required: 705 - Other - as specified
Due 29 February 2008
Resolved 30 May 2008
Resolution: Reviewed with master & shipwright. Multiple mast sections replaced.
Construction/Loadline › Hull › Keel
Issued 31 October 2007 Resolved
Pull sample keel bolt from midship / fwd area for examination.
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 30 April 2008
Resolution: Keel completely rebolted.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 31 October 2007 Resolved
Complete interior joiner work removed along w/ ceilings to allow access to hull frames and internal structural members from collision bhd to the fwd engine room bhd.
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 3 July 2008
Resolution: Passenger accommodations reinstalled to the vessel. Head compt slightly enlarged to allow easier access.
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 31 October 2007 Resolved
Plan review noted conflict in ground system method. Resolved by change to plan.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 16 June 2008
Resolution: Main panel & generator grounding completed IAW revised plans.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 31 October 2007 Resolved
Mount all portable fire extinguishing equipment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2008
Resolved 3 July 2008
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 31 October 2007 Resolved
Complete repairs to vessel and reinstall passenger accommodations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2008
Resolved 3 July 2008
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 31 October 2007 Resolved
Mark storage spaces for PFDs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2008
Resolved 3 July 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 4 June 2007 Resolved
Make permanent repair to MDE foundation at next drydocking.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 14 November 2007
Resolution: Reexamined MDE foundation after deck leaks above space were repaired and wood dried. Foundation found satisfactory because wood is sound & hard for most of depth. Note to monitor at future inspections.
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 4 June 2007 Resolved
Make temporary repairs to MDE foundation.
Condition: Improper/Lack of Maintenance
Due 14 June 2007
Resolved 9 July 2007
Resolution: Verified temp repair in place. Wet wood IWO foundation bolts dried, Rx w/ ethylene glycol and acetone, & hot coated w/ epoxy to seal out water. Permanent repairs to be completed at next drydocking.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 4 June 2007 Resolved
Provide supporting documents for the drug & alcohol screening program for the crew IAW 46 CFR 16.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2007
Resolved 9 July 2007
Engineering › Lubricating Oil Service System › Purifier
Issued 4 June 2007 Resolved
Correct oil leak from MDE lube oil filter.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 29 June 2007
Resolved 6 June 2007
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 4 June 2007 Resolved
Remove excess oil from bilge spaces.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 9 July 2007
Resolved 6 June 2007
Documentation › Certificates/Documents › FCC SSL
Issued 4 June 2007 Resolved
Provide FCC ship's station Licemse.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2007
Resolved 6 June 2007
Fire Fighting › Fire Bucket › Quantity
Issued 4 June 2007 Resolved
Provide three fire buckets.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2007
Resolved 6 June 2007
Lifesaving › Hand Flares › Expired
Issued 4 June 2007 Resolved
Provide current distress signals.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2007
Resolved 6 June 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 4 June 2007 Resolved
Repair bilge high water alarm.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2007
Resolved 6 June 2007
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 4 June 2007 Resolved
Post radio distress call placard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2007
Resolved 6 June 2007
Documentation › Certificates/Documents › FCC SSL
Issued 4 June 2007 Resolved
Provide FCC radio operators permits.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2007
Resolved 6 June 2007
Operations/Management › Drills/Instruction › Not Conducted
Issued 4 June 2007 Resolved
Conduct emergency drill w/ crew and crew training w/ CG Marine Inspector in attendance while u/w on sails.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2007
Resolved 6 June 2007
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 4 June 2007 Resolved
Provide service report for all fire protection equipment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2007
Resolved 6 June 2007
Operations/Management › Drug and Alcohol Testing › Collection Sites
Issued 4 June 2007 Resolved
Provide a means of conducting alcohol tests within two hours of any incident that should require a test.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2007
Resolved 8 June 2007
Resolution: Testing kits provided aboard vessel.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 4 June 2007 Resolved
Provide proof of enrolment and pre-employment testing for new crew members.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2007
Resolved 8 June 2007
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 4 June 2007 Resolved
Post EAP notices.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2007
Resolved 8 June 2007
Communications › Radio Communications › EPIRB
Issued 4 June 2007 Resolved
Provide EPIRB registration.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 9 July 2007
Resolved 9 July 2007
Construction/Loadline › Structures › Deck Plating
Issued 4 June 2007 Resolved
Caulk maindeck. (Deck leaks too much after crew reaved out old caulking.) Vessel not permitted to sail beyond confines of Greenport Harbor and protected route until deck recaulked.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 July 2007
Resolved 9 July 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 25 April 2005 Resolved
Replace alternator belt.
Due 10 May 2005
Resolved 3 May 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Engineering › Sea-water System (primary cooling) › Piping
Issued 25 April 2005 Resolved
Renew hose from cooling pump to expansion tank.
Due 10 May 2005
Resolved 3 May 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 25 April 2005 Resolved
Permanently connect solenoid to throttle.
Due 10 May 2005
Resolved 3 May 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Documentation › Logs/Records
Issued 10 June 2004 Resolved
Provide proof of drug testing program for vessel crew. LEGACY COMPONENT DESC: Drug Test Records
Due 24 June 2004
Resolved 11 June 2004
Documentation › Logs/Records
Issued 10 June 2004 Resolved
Start logbook for drills, firefighting and equipment safety checks.
Due 24 June 2004
Resolved 11 June 2004
Construction/Loadline › Hull
Issued 13 November 2003 Resolved
Complete previous requirements to replace starboard side planking #4, #7, and #10. Counted from keel. LEGACY COMPONENT DESC: Side Shell
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2004
Construction/Loadline › Hull
Issued 13 November 2003 Resolved
Replace #3 and #4 portside planks. Counted down from the sheer. LEGACY COMPONENT DESC: Side Shell
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 December 2003
Construction/Loadline › Hull
Issued 13 November 2003 Resolved
Refasten #7 plank on the port side of the vessel. Counted down from sheer. LEGACY COMPONENT DESC: Stiffener
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 December 2003
Construction/Loadline › Structures
Issued 13 November 2003 Resolved
On port side remove all inner ceiling were repairs are being done and contact MSFO to reinspect. Prior to leaving dry dock.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 April 2004
Construction/Loadline › Hull
Issued 13 November 2003 Resolved
Remove plank #10 on stbd side 1/4 length from bow, with dutchman repair, for CG MI to inspect frames. LEGACY COMPONENT DESC: Side Shell
Action required: 705 - Other - as specified
Resolved 16 April 2004
Construction/Loadline › Hull
Issued 17 July 2002 Resolved
Renew rotted shelf/clamp aft of stove on stbd side.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2003
Resolved 31 October 2002
Resolution: Shelf/clamp cropped and renewed.
Construction/Loadline › Hull
Issued 17 July 2002 Resolved
Renew plank IWO wind/water line, stbd side where temp repair on gouged wood is. #7 stbd from keel.
Condition: Improper Installation
Due 31 October 2003
Resolved 23 April 2004
Construction/Loadline › Hull
Issued 17 July 2002 Resolved
Renew plank #10 from keel (wind/waterline) stbd side, 1/4 of lenght from bow.
Condition: Improper Installation
Due 31 October 2003
Resolved 23 April 2004
Construction/Loadline › Hull
Issued 17 July 2002 Resolved
Renew plank #4 from garboard, stbd side.
Condition: Improper Installation
Due 31 October 2003
Resolved 23 April 2004
Documentation
Issued 12 May 2000 Resolved
COME INTO COMPLIANCE WITH USCG DRUG TESTING REGULATIONS.
Condition: Unknown
Due 25 May 2000
Resolved 19 May 2000
Documentation
Issued 20 April 1998 Resolved
PROVIDE CURRENT COPY OF CONTRACT FM CONSORTIUM.
Condition: Unknown
Due 24 April 1998
Resolved 24 April 1998
Fire Fighting
Issued 20 April 1998 Resolved
HYDROSTATICALLY TEST THE DRY CHEM B-II EXTINGUISHERS IN E/R AND ON DECK. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 24 April 1998
Resolved 23 April 1998
Documentation
Issued 23 May 1997 Resolved
PROVIDE A CURRENT FCC SAFETY CERTIFICATE. ROUTE LIMITED TO NMT 1000' FROM SHORE.
Condition: Unknown
Due 20 August 1997
Resolved 20 August 1997
Lifesaving
Issued 23 May 1997 Resolved
PROVIDE A COPY OF THE DRUG SCREENING CONTRACT. POST HOTLINE PHONE NUMBER &EMPLOYER POLICY.
Condition: Unknown
Due 20 August 1997
Resolved 20 August 1997
Electrical
Issued 23 May 1997 Resolved
COMPLETE THE INSTALLATION OF THE NEW SHORETIE PLUG.
Condition: Unknown
Due 20 August 1997
Resolved 20 August 1997
Deck/Cargo
Issued 4 January 1996 Resolved
REPLACE FOREMAST AND ALL WORN STANDING RIGGING PRIOR TO OPERATING VESSEL.
Condition: Unknown
Due 31 March 1996
Resolved 29 May 1996
Construction/Loadline
Issued 4 January 1996 Resolved
RENEW ROTTED SECTIONS OF WOOD DECKHOUSE ABOVE ENGINE SPACE.
Condition: Unknown
Due 31 March 1996
Resolved 29 May 1996
Construction/Loadline
Issued 4 January 1996 Resolved
REPLACE ROTTED SECTION OF AFT RAIL PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 31 March 1996
Resolved 29 May 1996
Construction/Loadline
Issued 27 April 1992 Resolved
COMPLETE WORKLIST ITEMS 10APR92 NYCMI, PRIOR TO CREDIT FOR DRYDOCK GIVEN.
Condition: Unknown
Due 5 May 1992
Resolved 5 May 1992
Documentation
Issued 18 May 1989 Resolved
PROVIDE CURRENT SAFETY RADIO TELEPHONE CERTIFICATE.
Condition: Unknown
Due 18 May 1989
Resolved 18 May 1989

Casualty record · 5

5 July 2009Routine · role: Involved in a Marine Casualty · activity 3556466
18 September 2009Routine · role: Involved in a Marine Casualty · activity 3614058
18 September 2011Routine · role: Involved in a Marine Casualty · activity 4149305
15 October 2015Routine · role: Involved in a Marine Casualty · activity 5743121
30 July 2021Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7275064
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record