← All vessels
KENSINGTON
KENSINGTON is a 1995 tank ship. The Coast Guard has recorded 10 inspections since 1996, most recently in October 2008, along with 3 deficiencies and 1 operational control.
Records from 1996 to 2008. Most recent: inspection, 10 October 2008.
- Built
- 1995
- Last inspected
- 10 October 2008
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 3 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9077874 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7FV9
417121
Flag
MARSHALL ISLANDS
—
Maury page id
psix-417121
Inspections, by type
…with no type recorded2
Years with a record
8 calendar years (1996–2008)
The 10 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it156802 - Convention (Subpart B), Gross Ton
107829 - Convention (Subpart B), Net Ton
298306 - Dead Weight, Ton
107829 - Convention (Subpart B), Net Ton
298306 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 10
10 October 2008
ISPS II Exam · COC-TVE Renew · Deficiency Check · Ballast Water Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3332563
23 October 2007
COC-CVE Annual · ISPS II Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3084805
17 April 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2909669
5 September 2006
COC-TVE Renew · Ballast Water Examination · ISPS III Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2758415
16 March 2005
ISPS II Exam · COC-TVE Annual
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2311907
19 October 2004
NPV Safety Exam · ISPS II Exam
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2223680
14 March 2004
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2026414
24 December 2002
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1735776
21 December 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 424183
1 July 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 392889
Deficiency record · 3
Deck/Cargo › Inert Gas System › IGS Blower
Issued 10 October 2008
Resolved
During the testing of the inert gas system, Port State Control Officers discovered that one of the inert gas blowers was inoperable. Vessel is to provide attestation from certificate issuing authority that permanent repairs and normal testing of inert gas blower is conducted to the satisfaction of local OCMI. This is to be rectified prior to next U.S. port after sailing foreign.
Documentation
Issued 1 July 1996
Resolved
APPROVAL LETTER OR CLASS CERTIFICATE MISSING FOR "HOTFOAM" FIXED FOAM FIREFIGHTING SYSTEM. PROOF OF COMPLIANCE WITH SOLAS TO BE SENT TO MSO MORGAN CITY PRIOR TO NEXT ENTRY INTO U.S. WATERS.
Documentation
Issued 1 July 1996
Resolved
VESSEL RESPONSE PLAN NOT APPROVED.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National