02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 3 July 2019
No resolution recorded
Conduct permannent repairs to lower and middle clamp at midbody
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 July 2019 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 3 July 2019
No resolution recorded
Conduct permanennt repairs to failed transverse frames within machinery space, approximately 20 laminar 2'X4" white oak frames have seperated from their lower laminate on the starboard side, appproixamtely 6 frames on the Port side have failed identically
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 3 July 2019 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 3 July 2019
No resolution recorded
Replace as original 3 transverse frames and 3 underdeck frames as marked in forward laz
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 3 July 2019 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 3 July 2019
No resolution recorded
Open and make available for inspection intersection of transverse under deck framing that ties the rudder stock into the clamp on both Port anad Starboard side
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 3 July 2019 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 3 July 2019
No resolution recorded
Conduct permanenet repairs to Port aft qtr. clampboard sistered to a 4"4" that has rotted due to fresh water ingress
Action required: 15 - Rectify deficiencies by next port
Due 3 July 2019 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 3 July 2019
No resolution recorded
Replace all underdeck transverse frames as marked with line locker space as marked
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Due 3 July 2019 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 3 July 2019
No resolution recorded
Within froward lazarette replace all failed transverse frames stbd. side as marked
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 3 July 2019 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 3 July 2019
No resolution recorded
Within forward lazarette repalce all failed underdeck transverse as marked
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 3 July 2019 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 3 July 2019
No resolution recorded
Remove and make available plexiglass doubler above prop that is reported by O/O to stop water ingress into forward laz
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 3 July 2019 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 July 2019
No resolution recorded
Conduct credit fastener pull
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 3 July 2019 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 3 July 2019
No resolution recorded
Effect permanenet repair to fractured garboard plank
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 3 July 2019 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 3 July 2019
No resolution recorded
Replace wasted deck covering focsle and line locker
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 3 July 2019 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 3 July 2019
No resolution recorded
Replace all under deck transverse deck frames that are rotting at the intersection of the clamp
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 3 July 2019 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 3 July 2019
No resolution recorded
Recotton/caulk as observed based on water leaking out of hul at CVK, garboard plank and multiple butts
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 3 July 2019 — due date passed with no resolution recorded
Construction/Loadline › Structures › Superstructure
Issued 11 May 2017
No resolution recorded
Owner has been told that a repair proposal needs to be submitted and all repairs need to be conducted on vessel before credit dry-dock will be issued. Vessel has extensive damage to sheer strake and superstructure due to water immersion from the upper and lower deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Documentation › Certificates/Documents › FCC SSL
Issued 15 June 2016
Resolved
Provide FCC station Lic and Renew Safety Radio Cert
Due 15 July 2016
Resolved 9 August 2016
Resolution: Cert provided.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 15 June 2016
Resolved
Post Life Jacket Donning Instructions
Due 15 July 2016
Resolved 19 July 2016
Resolution: Life jacket placard posted.
Lifesaving › Lifebuoys › Serviceable
Issued 15 June 2016
Resolved
Renew ring bouy and float light.
Due 15 July 2016
Resolved 19 July 2016
Resolution: Ring bouy replaced. Light does not need to be replaced.
Lifesaving › Hand Flares › Expired
Issued 15 June 2016
Resolved
provide distress signals
Due 15 July 2016
Resolved 9 August 2016
Resolution: Distress signals provided.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 15 June 2016
Resolved
Mark upper deck passenger limit.
Due 15 July 2016
Resolved 19 July 2016
Resolution: Passenger deck labeled.
Navigation › Piloting/Steering › Notices to Navigation
Issued 15 June 2016
Resolved
Read notice to mariners
Due 15 July 2016
Resolved 19 July 2016
Resolution: Notice to mariners read.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 15 June 2016
Resolved
Repair forepeak hatch cover
Due 15 July 2016
Resolved 19 July 2016
Resolution: Hatch cover repaired.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 15 June 2016
Resolved
Secure sewage pipe in transome (zipties removed)
Due 15 July 2016
Resolved 19 July 2016
Resolution: Pipe secured.
Engineering › Bilge Water Management System › Valve
Issued 15 June 2016
Resolved
Secure valve on PS transome hose (bilge)
Due 15 July 2016
Resolved 19 July 2016
Resolution: valve secured.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 June 2016
Resolved
repair/replace stern light. (restricted to day operations only).
Due 15 July 2016
Resolved 19 July 2016
Resolution: Stern light repaired.
Engineering › Freshwater System (cylinder head cooling) › Hose
Issued 15 June 2016
Resolved
Replace cooling hose on MDE
Due 15 July 2016
Resolved 19 July 2016
Resolution: Hose replaced.
Fire Fighting › Fire Pumps › Pressure
Issued 15 June 2016
Resolved
Repair fire pump and demonstrate water pressure stream.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2016
Resolved 15 June 2016
Resolution: Received an email with a photo and video showing that the pump has been repaired and the pressure is acceptable. 07/19/2016 Had operator operate fire pump during def check exam. Pressure good.