Records from 1983 to 2008. Most recent: inspection, 14 July 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 30
14 July 2008
Simplified Stability Test
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3267637
29 January 2006
Deficiency Check · Plan Review "T" Boat
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2970334
2 February 2005
Administrative Inspection
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2285244
31 January 2005
Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2285038
8 September 2003
Hull Examination
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2098215
5 October 2001
Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1074505
22 June 2000
COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1393457
1 June 1999
Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1384152
11 March 1999
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 809745
23 June 1998
Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1368797
13 June 1997
Hull Examination · Initial Certification
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1460055
9 May 1996
Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1088148
30 June 1995
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 884208
26 May 1995
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 862411
26 May 1995
COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1467899
19 October 1994
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 864468
20 July 1994
Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 870256
25 May 1993
Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1417492
13 January 1993
Examination of Repairs
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1389758
22 May 1992
COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1465713
17 May 1991
Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1220948
2 April 1991
Hull Examination
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1224561
10 May 1990
Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 918777
8 June 1989
COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1201089
13 June 1988
Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1201232
15 July 1987
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1333277
15 April 1987
Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1318101
16 May 1986
COI Inspection · Credit Drydock
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 993614
16 May 1985
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 988919
16 May 1983
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 989083
Construction/Loadline › Hull › Hull Plating
Issued 2 February 2005
Resolved
Vessel shows evidence of sagging on the starboard side aft 10ft forward of the stern. Owner states the vessel was lengthened to 59ft, however all documentation states 49ft.. Provide a full inclining test report attesting to the stability of of the vessel, in it's present condition.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 February 2005
Resolved 8 February 2005
Construction/Loadline › Structures › Deck Plating
Issued 2 February 2005
Resolved
Remove all decking to expose the internal framing, to the satisfaction of the attending Marine Inspector.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 February 2005
Construction/Loadline › Penetrations › Pipe Flange
Issued 2 February 2005
Resolved
Remove all through hull fittings for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2005
Construction/Loadline › Penetrations › Bottom Plug Packing
Issued 2 February 2005
Resolved
Remove shaft and replace bearing in both struts and through hull, to the satisfaction of the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 November 2005
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 2 February 2005
Resolved
Provide new Certificate of documentation with the proper length of the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 February 2005
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 31 January 2005
Resolved
Provide new Certificate of Documentation with the proper length of the vessel.
Action required: 705 - Other - as specified
Resolved 8 February 2005
Construction/Loadline › Hull › Hull Plating
Issued 31 January 2005
Resolved
Caulking has been removed from the planking. Continue to replace caulking to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 November 2005
Construction/Loadline › Hull › Keel
Issued 31 January 2005
Resolved
Keel has been repaired, is soft and cracked in the area just aft of the stem and aft 15ft. Expose the area from interior as need to inspect. Submit repair proposal proper to conducting repairs.
Action required: 705 - Other - as specified
Resolved 8 February 2005
Construction/Loadline › Hull › Keel
Issued 31 January 2005
Resolved
Several keel bolts exposed and show signs of wastage. Clean and expose all visible bolts in the keel or planking for further inspection to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Resolved 8 February 2005
Construction/Loadline › Hull › Keel Plate
Issued 31 January 2005
Resolved
Plank forward starboard side cracked and rotted in way of fasteners. Replace plank as marked to the satisfaction of the attending Marine Inspector. Do not replace planks until further inspection is compete
Action required: 705 - Other - as specified
Resolved 8 February 2005
Construction/Loadline › Hull › Keel
Issued 31 January 2005
Resolved
Improper repair of the stem in way of the rabbit. Expose from interior and remove planks for inspection of stem for further inspection to the satisfaction of the attending Marine Inspector. Do not replace planks until further inspection is completed
Action required: 705 - Other - as specified
Resolved 8 February 2005
Construction/Loadline › Hull › Hull Plating
Issued 31 January 2005
Resolved
Plank on the turn of the bilge aft on stern rotted and cracked. Replace plank as marked, to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Resolved 16 September 2005
Construction/Loadline › Hull › Keel Plate
Issued 31 January 2005
Resolved
Four planks in way of the starboard strut with improper repairs and rot. Remove planks and expose framing for further inspection to the satisfaction of the attending Marine Inspector. Do not replace planks until further inspection is competed.
Action required: 705 - Other - as specified
Resolved 16 September 2005
Fire Fighting › Combustible Materials › Linings
Issued 31 January 2005
No resolution recorded
Provide proper insulation to engine space, inspection to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Construction/Loadline › Structures › Superstructure
Issued 31 January 2005
No resolution recorded
Hatch cover rotted and broken. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector
Action required: 705 - Other - as specified
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 31 January 2005
No resolution recorded
Navigation lights not mounted. Make permanent and proper repairs and prove proper operation, to the satisfaction of the attending Marine Inspector
Action required: 705 - Other - as specified
Construction/Loadline › Hull › Hull Plating
Issued 31 January 2005
Resolved
Four planks in way of the port strut has been removed. All carriage bolts must be removed and the holes repaired as well as other holes from other fasteners. Submitt propsal for permenant and proper repairs prior to replacing planks.
Action required: 705 - Other - as specified
Resolved 21 November 2005
Construction/Loadline › Hull › Hull Plating
Issued 31 January 2005
Resolved
Plank removed port side at transom as required. Submitt proprosal to complete repairs to the wood at the corner of the transom and cracked frames.
Action required: 705 - Other - as specified
Resolved 21 November 2005
Construction/Loadline › Hull › Hull Plating
Issued 31 January 2005
Resolved
Renew scantlings to original (plans needed) or submit plans for review to Marine Safety Center as required in 46CFR177.202 and prove proper design as in 46CFR177.300 or submit plans as required by 46CFR177.340. This must be completed before any inspections can continue so the proper scantling can be determined as well as what repairs are needed to replace the strength in the vessel.
Action required: 705 - Other - as specified
Resolved 21 November 2005
Documentation
Issued 22 June 2000
Resolved
Make vessel available for complete Inspection for Certification prior to operating with passengers for hire.
Condition: Unknown
Due 22 August 2001
Resolved 28 May 2004
Resolution: Vessel is out-of-service.
Documentation
Issued 1 June 1999
Resolved
PROVIDE RADIOTELEPHONY CERTIFICATE OR EQUIVALENT FOR RADIO. VESSEL LIMITEDTO 1000 FEET OF SHORE UNTIL PROVIDED.
Condition: Unknown
Due 21 June 1999
Resolved 15 June 1999
Lifesaving
Issued 1 June 1999
Resolved
PROVIDE 3 SMOKE FLARES.
Condition: Unknown
Due 21 June 1999
Resolved 15 June 1999
Fire Fighting
Issued 1 June 1999
Resolved
MAKE AND POST SIGN FOR BYPASS SWITCH ON F/E SYSTEM STATING "SWITCH MUST BE IN ON POSITION WHILE OPERATING" OR WORDS TO THAT EFFECT.
Condition: Unknown
Due 21 June 1999
Resolved 15 June 1999
Fire Fighting
Issued 1 June 1999
Resolved
PROVIDE APPROVED BII FIRE EXTINGUISHER.
Condition: Unknown
Due 21 June 1999
Resolved 15 June 1999
Lifesaving
Issued 1 June 1999
Resolved
REPLACE LINE FOR WATERLIGHT AND LAST 1-2 FEET OF LINE THAT ATTACHES TO RINGBOUY. STENCIL VESSEL NAME ON BOUY. WATERLIGHT TO BE ATTACHED TO BOUY WITHCLIP.
Condition: Unknown
Due 21 June 1999
Resolved 15 June 1999
Fire Fighting
Issued 1 June 1999
Resolved
FIRE EXT. SYSTEM FOR ENGINEROOM TO BE HOOKED UP PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 21 June 1999
Resolved 15 June 1999
Fire Fighting
Issued 1 June 1999
Resolved
PROVIDE 3 FIRE BUCKETS.
Condition: Unknown
Due 21 June 1999
Resolved 15 June 1999
Lifesaving
Issued 1 June 1999
Resolved
VESSEL LIMITED TO 44 TOTAL PEOPLE UNTIL ADDITIONAL APPROVED PFD'S PROVIDED.
Condition: Unknown
Due 21 June 1999
Resolved 15 June 1999
Fire Fighting
Issued 11 March 1999
Resolved
VESSEL CAN NOT OPERATE WITH PASSENGERS UNTIL IT IS IN COMPLIANCE WITH THE NEW FIXED FIRE EXTINGUISHING SYSTEM REQUIREMENTS.
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Construction/Loadline
Issued 11 March 1999
Resolved
VESSEL CAN NOT OPERATE WITH PASSENGERS UNTIL IT IS IN COMPLIANCE WITH THE NEW BILGE SYSTEM REQUIREMENTS.
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Lifesaving
Issued 23 June 1998
Resolved
REPLACE BATTERIES/BULBS IN FLASHLIGHTS TO MAKE OPERATIONAL.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Lifesaving
Issued 23 June 1998
Resolved
PROVIDE INSTRUCTIONS FOR EQUIPMENT IN FIRST AID KIT.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Navigation
Issued 23 June 1998
Resolved
PROVIDE ANCHOR LIGHT AND DAY SHAPE FOR VESSEL.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Documentation
Issued 23 June 1998
Resolved
PROPERLY MARK NAME AND HOMEPORT ON STERN OF VESSEL.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Documentation
Issued 23 June 1998
Resolved
POST ORIGINAL COI UNDER GLASS FOR DISPLAY ON VESSEL.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Lifesaving
Issued 26 May 1995
Resolved
Provide sign in forward cockpit requiring passengers to remain seated.
Condition: Unknown
Due 26 June 1995
Resolved 13 June 1995
Lifesaving
Issued 26 May 1995
Resolved
Light on ring buoy inoperative.
Condition: Unknown
Due 1 June 1995
Resolved 1 June 1995
Documentation
Issued 26 May 1995
Resolved
Provide Great Lakes Radiotelephony Certificate on board.
Condition: Unknown
Due 26 June 1995
Resolved 13 June 1995
Navigation
Issued 25 May 1993
Resolved
RAISE MASTHEAD LIGHT TO A HEIGHT OF AT LEAST 2.5 METERS ABOVE THE GUNWALE.
Condition: Unknown
Due 25 May 1993
Resolved 25 May 1993
Accommodation/Occupational Safety
Issued 25 May 1993
Resolved
DEMONSTRATE OPERATION OF TOILETS AND WASH BASINS. VESSEL RESTRICTED TO VOTAGES LESS THAN 30 MINUTES UNTIL TOILETS ARE OPERATIONAL. VESSEL RESTRICTED TO LESS THAN 49 PASSENGERS UNTIL WASH BASINS ARE OPERATIONAL.
Condition: Unknown
Due 25 May 1993
Resolved 25 May 1993
Accommodation/Occupational Safety
Issued 22 May 1992
Resolved
LABLE MEN'S HEAD
Condition: Unknown
Due 26 May 1992
Resolved 1 June 1992
Documentation
Issued 22 May 1992
Resolved
CORRECT "LENGTH" ON VESSEL'S DOCUMENT.
Condition: Unknown
Due 22 May 1992
Resolved 22 May 1992
Electrical
Issued 22 May 1992
Resolved
RE-TIE AFT BILGE PUMP WIRES OUT OF BILGES.
Condition: Unknown
Due 26 May 1992
Resolved 1 June 1992
Deck/Cargo
Issued 22 May 1992
Resolved
PROVIDE ADEQUATE ANCHOR LINE
Condition: Unknown
Due 22 May 1992
Resolved 22 May 1992
Accommodation/Occupational Safety
Issued 22 May 1992
Resolved
RE-PRIME & DEMONSTRATE TOILETS & SINKS IN MEN'S & WOMEN'S HEADS.
Condition: Unknown
Due 26 May 1992
Resolved 1 June 1992
Engineering
Issued 22 May 1992
Resolved
REPLACE F/O VENT SCREENS WITH 30X30 MESH
Condition: Unknown
Due 22 May 1992
Resolved 22 May 1992
Navigation
Issued 22 May 1992
Resolved
TIGHTEN GUIDE BEARING STEERING ROD.
Condition: Unknown
Due 26 May 1992
Resolved 1 June 1992