← All vessels
ARMONIA
Freight Ship · General Dry Cargo Ship class · Built 1990s · USCG East District (CGD-E) · Other hulls named ARMONIA
ARMONIA is a 1992 freight ship. The Coast Guard has recorded 25 inspections since 2004, most recently in December 2010, along with 19 deficiencies and 7 operational controls.
Records from 2004 to 2010. Most recent: inspection, 6 December 2010.
- Built
- 1992
- Last inspected
- 6 December 2010
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 19 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9017628 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3EZY9
417433
Flag
SINGAPORE
—
Maury page id
psix-417433
Inspections, by type
…with no type recorded11
Years with a record
6 calendar years (2004–2010)
The 25 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it5988 - Convention (Subpart B), Gross Ton
3602 - Convention (Subpart B), Net Ton
3602 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 25
6 December 2010
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3901414
26 November 2010
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3899066
19 November 2010
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3894738
29 November 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3370968
12 June 2008
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3234868
20 March 2007
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2891239
7 February 2007
Random ISPS/MTSA/PSC
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2868690
2 February 2007
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2866193
28 August 2006
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2762725
31 July 2006
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2731010
10 June 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2675492
23 May 2006
Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2656803
27 February 2006
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2579038
23 January 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2571289
12 December 2005
Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2550167
22 October 2005
Ballast Water Examination · NPV Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2523911
14 September 2005
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2492161
23 August 2005
ISPS III Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2472085
17 April 2005
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2336001
17 April 2005
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2478628
14 January 2005
NPV Safety Exam · Ballast Water Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2274744
20 October 2004
ISPS II Exam · ILO-147 Exam · ISM Exam · MARPOL Annex V Examination · PII Safety Exam · MARPOL Annex I Examination · Loadline Exam · STCW 95 Exam
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2225061
11 June 2004
MTSA/ISPS Verification
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2095522
10 June 2004
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2095207
19 April 2004
Annual Inspection · Ballast Water Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2047249
Deficiency record · 19
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 November 2010
Resolved
Vessel's self-igniting light on the stern by the mooring winches does not operate properly. Repair/replace self-igniting light as per manufacturers guidelines. SOLAS 74 (Con. 92) III/31.2
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 November 2010
Resolved
Vessel's self-igniting light beside the starboard side liferaft does not operate properly. Repair/replace self-igniting light as per manufacturers guidelines. SOLAS 74 (Con. 92) III/31.2
Electrical › Electrical Distribution System (service) › Switchboard
Issued 19 November 2010
Resolved
Vessel's main switchboard in the engine control room ahs multiple boxes and equipment stored behind the switch board. Remove all unnecessary items for easy access. SOLAS 74 (Con. 92) I/45.2
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 29 November 2008
Resolved
Received notification that the vessel's automated bridge control for the main engine controllable pitch is non-operational and the vessel can only operate the system manually. Prior to departure from the Port of Houston, the vessel shall submit documentation from the Certificate [name withheld] attesting to the proper operation of the pitch controller.
Engineering › Fuel Oil Service System › Pump
Issued 12 June 2008
Resolved
Fuel oil pumps #3 and #4 have noticeable leaks. The return line has severe leaks form all the valves causing severe saturation on all applicable lagging.
Fire Fighting › Fire Hoses › Location
Issued 7 February 2007
Resolved
Class to attest to the location of fire hose in relation to hydrant on forecastle. Currently hose in locked space. Solas CH II-2 reg 10.2.3.1.1
Construction/Loadline › Structures › End Bulkhead
Issued 7 February 2007
Resolved
Soft patch needs to be repaired to ensure watertight integrity on starboard side of super structure forward bulkhead, in vent #53 on boat deck. Solas CH1 reg 11.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 February 2007
Resolved
Deck rails on starboard side and on forecastle need to be renewed. ICLL CHII Reg 25 (2)
Construction/Loadline › Structures › Door
Issued 7 February 2007
Resolved
Weather tight door on starboard side is capable of being closed manually but dogs are inoperable repair/replace to the satisfaction of class. ICLL CH II Reg 12
Construction/Loadline › Structures › Superstructure
Issued 7 February 2007
Resolved
Vent hole leading to storage space aft starboard side has wiring that prevents proper closure. Rewire or provide alternative means for wiring. ICLL Reg 3.10 (6) (III)
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 22 October 2005
Resolved
Incinerator will not operate. Prove proper operation of incinerator.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 22 October 2005
Resolved
Currently using blower to prevent over heating of propeller shaft. Prove proper operation of main shaft.
Construction/Loadline › Structures › Superstructure
Issued 22 October 2005
Resolved
Port and Starboard side handrails are wasted and parts are missing.
Construction/Loadline › Structures › Superstructure
Issued 22 October 2005
Resolved
ladder in forecastle near paint locker is wasted beyond acceptable means.
Engineering › Diesel Engine (propulsion-electric) › Valve
Issued 17 April 2005
Resolved
Vessels main diesel engine starting valve is inoperable.
Engineering › Freshwater System (air cooling) › Pump
Issued 20 October 2004
Resolved
AC cooling pump packing needs replacement.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 20 October 2004
Resolved
Oily Water Separator system piping had inadequate fiberglass patches.
Engineering › Fuel Oil Storage/Transfer System › Flange
Issued 20 October 2004
Resolved
Replace packing in emergency shut-off valve for emergency generator fuel tank.
Lifesaving › Lifeboat
Issued 19 April 2004
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.