ARMONIA is a 1992 freight ship. The Coast Guard has recorded 25 inspections since 2004, most recently in December 2010, along with 19 deficiencies and 7 operational controls.

Records from 2004 to 2010. Most recent: inspection, 6 December 2010.

Built
1992
Last inspected
6 December 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9017628 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
417433
Flag
SINGAPORE
—
Maury page id
psix-417433

Inspections, by type

…with no type recorded11
Years with a record 6 calendar years (2004–2010)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it5988 - Convention (Subpart B), Gross Ton
3602 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 25

6 December 2010 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3901414
26 November 2010 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3899066
19 November 2010 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3894738
29 November 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3370968
12 June 2008 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3234868
20 March 2007 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2891239
7 February 2007 Random ISPS/MTSA/PSC
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2868690
2 February 2007 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2866193
28 August 2006 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2762725
31 July 2006 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2731010
10 June 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2675492
23 May 2006 Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2656803
27 February 2006 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2579038
23 January 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2571289
12 December 2005 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2550167
22 October 2005 Ballast Water Examination · NPV Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2523911
14 September 2005 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2492161
23 August 2005 ISPS III Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2472085
17 April 2005 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2336001
17 April 2005 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2478628
14 January 2005 NPV Safety Exam · Ballast Water Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2274744
20 October 2004 ISPS II Exam · ILO-147 Exam · ISM Exam · MARPOL Annex V Examination · PII Safety Exam · MARPOL Annex I Examination · Loadline Exam · STCW 95 Exam
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2225061
11 June 2004 MTSA/ISPS Verification
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2095522
10 June 2004 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2095207
19 April 2004 Annual Inspection · Ballast Water Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2047249

Deficiency record · 19

Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 November 2010 Resolved
Vessel's self-igniting light on the stern by the mooring winches does not operate properly. Repair/replace self-igniting light as per manufacturers guidelines. SOLAS 74 (Con. 92) III/31.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 November 2010
Resolved 26 November 2010
Resolution: Vessel''s self-igniting light on stern functioning properly. All other self igniting lights checked for proper operation. All Sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 November 2010 Resolved
Vessel's self-igniting light beside the starboard side liferaft does not operate properly. Repair/replace self-igniting light as per manufacturers guidelines. SOLAS 74 (Con. 92) III/31.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 November 2010
Electrical › Electrical Distribution System (service) › Switchboard
Issued 19 November 2010 Resolved
Vessel's main switchboard in the engine control room ahs multiple boxes and equipment stored behind the switch board. Remove all unnecessary items for easy access. SOLAS 74 (Con. 92) I/45.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 November 2010
Resolved 26 November 2010
Resolution: All unnecessary items have been removed from rear of Main Switch board access to the satisfaction of Marine Inspector.
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 29 November 2008 Resolved
Received notification that the vessel's automated bridge control for the main engine controllable pitch is non-operational and the vessel can only operate the system manually. Prior to departure from the Port of Houston, the vessel shall submit documentation from the Certificate [name withheld] attesting to the proper operation of the pitch controller.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2008
Resolved 29 November 2008
Resolution: Received Class report. Imposed Condition of Class for two months for permanent reparis to be carried out of bridge controllable pitch control system. Issued conditional Certificate of Class, valid for two months, for engine room to be manned full-time.
Engineering › Fuel Oil Service System › Pump
Issued 12 June 2008 Resolved
Fuel oil pumps #3 and #4 have noticeable leaks. The return line has severe leaks form all the valves causing severe saturation on all applicable lagging.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 June 2008
Resolution: received class report attesting to the proper overhaul and replacement of fuel pumps. Vessel is released from opcon
Fire Fighting › Fire Hoses › Location
Issued 7 February 2007 Resolved
Class to attest to the location of fire hose in relation to hydrant on forecastle. Currently hose in locked space. Solas CH II-2 reg 10.2.3.1.1
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 7 March 2007
Resolved 20 March 2007
Resolution: Received class report verifying location as being in accordance with approved fire plan. Locked space is in compliance to ISPS. Space will be secured with plastic tie so hose can be accessed.
Construction/Loadline › Structures › End Bulkhead
Issued 7 February 2007 Resolved
Soft patch needs to be repaired to ensure watertight integrity on starboard side of super structure forward bulkhead, in vent #53 on boat deck. Solas CH1 reg 11.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2007
Resolved 12 June 2008
Resolution: Cleared def based on class report attesting to the temporary repairs and condition of class to be rectified on vessel''s dry dock. Permanent repairs have been completed and approved to the satisfaction of class and USCG as per inspection on 12JUN2008.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 February 2007 Resolved
Deck rails on starboard side and on forecastle need to be renewed. ICLL CHII Reg 25 (2)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 March 2007
Resolved 20 December 2007
Resolution: Deck rails renewed.
Construction/Loadline › Structures › Door
Issued 7 February 2007 Resolved
Weather tight door on starboard side is capable of being closed manually but dogs are inoperable repair/replace to the satisfaction of class. ICLL CH II Reg 12
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2007
Resolved 20 December 2007
Resolution: Mechinisium removed, all freed and nw, spindle bearing assembly made and fitted.
Construction/Loadline › Structures › Superstructure
Issued 7 February 2007 Resolved
Vent hole leading to storage space aft starboard side has wiring that prevents proper closure. Rewire or provide alternative means for wiring. ICLL Reg 3.10 (6) (III)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 March 2007
Resolved 20 December 2007
Resolution: wires and cables remved and routed through correct cable glands.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 22 October 2005 Resolved
Incinerator will not operate. Prove proper operation of incinerator.
Action required: 705 - Other - as specified
Due 29 October 2005
Resolved 12 December 2005
Resolution: Received class report stating that repairs have been made to their satisfaction.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 22 October 2005 Resolved
Currently using blower to prevent over heating of propeller shaft. Prove proper operation of main shaft.
Action required: 705 - Other - as specified
Due 29 October 2005
Resolved 12 December 2005
Resolution: Received class report that repairs were made to their satisfaction.
Construction/Loadline › Structures › Superstructure
Issued 22 October 2005 Resolved
Port and Starboard side handrails are wasted and parts are missing.
Action required: 705 - Other - as specified
Due 22 November 2005
Resolved 12 December 2005
Resolution: Received class report that all repairs to handrails have been made to their satisfaction.
Construction/Loadline › Structures › Superstructure
Issued 22 October 2005 Resolved
ladder in forecastle near paint locker is wasted beyond acceptable means.
Action required: 705 - Other - as specified
Due 22 November 2005
Resolved 12 December 2005
Resolution: Received class report that repairs have been made.
Engineering › Diesel Engine (propulsion-electric) › Valve
Issued 17 April 2005 Resolved
Vessels main diesel engine starting valve is inoperable.
Action required: 705 - Other - as specified
Due 18 April 2005
Resolved 17 April 2005
Resolution: Class surveyor for Lloyds Register inspected and verified that the main diesel engine starting valve had been replaced and was working appropriately.
Engineering › Freshwater System (air cooling) › Pump
Issued 20 October 2004 Resolved
AC cooling pump packing needs replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 November 2004
Resolved 1 November 2004
Resolution: Received class report from [name withheld] stating packing has been replaced, and actual leaking found normal for this type of pump.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 20 October 2004 Resolved
Oily Water Separator system piping had inadequate fiberglass patches.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 November 2004
Resolved 1 November 2004
Resolution: Class report from LR states pipe renewed as required. All fiberglass patches removed.
Engineering › Fuel Oil Storage/Transfer System › Flange
Issued 20 October 2004 Resolved
Replace packing in emergency shut-off valve for emergency generator fuel tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 November 2004
Resolved 1 November 2004
Resolution: Class report from LR states packing in quick closing valve for emergency generator renewed. Found free of leaks.
Lifesaving › Lifeboat
Issued 19 April 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 19 April 2004
Resolved 20 April 2004
Resolution: Received class report attesting to the satisfactory repair of lifeboat. The deficiency is considered corrected.

Ownership record