Records from 1995 to 2021. Most recent: inspection, 20 September 2021.
Inspection history · 93
20 September 2021
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7316146
29 September 2015
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5731890
12 March 2009
COI Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3432320
7 January 2009
Underwater Inspection in lieu of Drydock
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3390405
19 November 2008
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3366146
10 October 2008
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3349561
8 April 2008
COI Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3179673
9 January 2008
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3127386
8 January 2008
Deadweight Survey · Internal Structural Exam · Underwater Inspection in lieu of Drydock
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3126988
15 October 2007
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3080632
24 July 2007
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3005972
17 July 2007
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2998426
11 June 2007
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2958536
25 April 2007
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2915118
11 April 2007
Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2906128
5 February 2007
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2867344
31 January 2007
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2864751
10 January 2007
Administrative Inspection · Hull Examination · Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2853519
20 October 2006
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2804473
11 September 2006
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2776491
21 June 2006
Administrative Inspection · Plan Review (Other than "T")
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2686783
24 April 2006
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2632077
9 January 2006
Hull Examination · Internal Structural Exam
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2564285
12 December 2005
Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2549847
4 August 2005
Plan Review (Other than "T") · Administrative Inspection
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2451257
23 May 2005
Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2366179
21 April 2005
MTSA Verification · COI Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2339489
9 February 2005
Hull Examination
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2289154
22 April 2004
COI Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2049842
22 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979456
12 December 2003
Administrative Inspection
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1963053
23 October 2003
Periodic Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1936959
24 April 2003
COI Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1779897
13 January 2003
Internal Structural Exam · Hull Examination
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1733971
3 January 2003
Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1999390
22 October 2002
Periodic Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1693416
17 April 2002
COI Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1609775
5 November 2001
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 772024
14 August 2001
Re-Inspection · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1069200
24 May 2001
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1065632
7 May 2001
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1366342
11 April 2001
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1061910
28 February 2001
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1451664
13 February 2001
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1373321
8 January 2001
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1448214
6 September 2000
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 822384
17 August 2000
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 821883
9 May 2000
COI Inspection · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1379093
19 April 2000
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1423353
8 February 2000
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 816368
8 February 2000
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1391243
8 February 2000
Drydock Extension
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1397232
22 December 1999
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 812156
9 November 1999
Re-Inspection · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1378859
10 August 1999
Deficiency Check · Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1397233
10 May 1999
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1416910
16 March 1999
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 807753
4 February 1999
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1129470
9 December 1998
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 809295
9 October 1998
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 803610
3 September 1998
Re-Inspection · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1418396
19 August 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 797586
23 June 1998
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 170194
19 May 1998
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 63990
19 May 1998
Deficiency Check · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1472515
16 April 1998
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 790033
10 March 1998
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1466504
11 February 1998
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 72110
17 December 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 784089
3 December 1997
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1375210
20 November 1997
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1107845
27 August 1997
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1437309
3 June 1997
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 187774
27 May 1997
Deficiency Check · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1386040
20 April 1997
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1093427
19 March 1997
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 224139
17 March 1997
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1383480
21 January 1997
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1105662
9 December 1996
Re-Inspection · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1435853
28 October 1996
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1173714
21 October 1996
Examination of Repairs · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1421212
9 September 1996
Re-Inspection · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1446387
20 June 1996
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1417980
29 May 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1360510
12 May 1996
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1083992
7 July 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 882826
14 June 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1188486
2 June 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 874441
23 May 1995
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1355246
26 April 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 187457
24 March 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1358658
10 February 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 24890
8 February 1995
Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1160105
Fire Fighting › Automatic Sprinkler System › Piping
Issued 11 April 2007
Resolved
Port side, aux machine room - fire sprinkler pump and #2 fire pump loose suction prime when crossover valves to chiller units are open. Draft proposal and submit to local CG OCMI for review modifications to fire main piping to correct this situation. Make all alterations to fire main piping in accordance with 46 CFR 76.25 "Automatic Sprinkler Systems".
Action required: 705 - Other - as specified
Due 12 May 2007
Resolved 17 July 2007
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 11 April 2007
Resolved
#2 main diesel engine - Prove proper operation of all automation alarms.
Action required: 705 - Other - as specified
Due 26 April 2007
Resolved 17 July 2007
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 11 April 2007
Resolved
#3 main diesel engine - Prove proper operation of low lube oil pressure and high jacket water temperature alarms.
Action required: 705 - Other - as specified
Due 26 April 2007
Resolved 17 July 2007
Electrical › Electrical Distribution System (service) › Panelboard
Issued 11 April 2007
Resolved
Properly label all circuit breaker panels throughout vessel in accordance with 46 cfr 111.40-11.
Action required: 705 - Other - as specified
Due 17 August 2007
Resolved 10 April 2008
Resolution: Labeled all pannels.
Electrical › Electrical Distribution System (service) › Cable
Issued 11 April 2007
Resolved
Port side main deck, forward cable run access closet - Properly seal 2 fire stop blocks in way of deck. Pull back and remove any unused cable, and clean out excessive amount of clutter and trash on deck.
Action required: 705 - Other - as specified
Due 17 August 2007
Resolved 10 April 2008
Resolution: Replaced blocks.
Fire Fighting › Ventilation Systems › Ducts
Issued 11 April 2007
Resolved
Throughout vessel - Clean excessive accumulation of dirt, dust, and debris from ventilation system, fire dampeners, and any associated HVAC ducting. Prove proper operation of all fire dampeners.
Action required: 705 - Other - as specified
Due 26 April 2007
Resolved 17 July 2007
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 11 April 2007
Resolved
Throughout vessel - Numerous areas of fire retardant overhead insulation and ceiling panels missing or improperly installed. Properly repair or install all fire protective coverings and panels.
Action required: 705 - Other - as specified
Due 17 August 2007
Resolved 10 April 2008
Resolution: Replaced all ceiling tiles.
Fire Fighting › Means of Escape › Doorways
Issued 11 April 2007
Resolved
Main deck exterior doors, ensure proper operation of general use and emergency exit doors.
Action required: 705 - Other - as specified
Due 26 April 2007
Resolved 17 July 2007
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 11 April 2007
Resolved
In addition to identified CG-835 deficiency items, complete all additional items on worklist generated during CG inspection.
Action required: 705 - Other - as specified
Due 12 May 2007
Resolved 17 July 2007
Electrical › Lighting (emergency) › Lighting Fixture
Issued 11 April 2007
Resolved
Emergency lighting throughout vessel - restencil or label missing or painted over red "E" on fixtures.
Action required: 705 - Other - as specified
Due 26 April 2007
Resolved 17 July 2007
Operations/Management › Pollution › Control of Discharge of Oil
Issued 21 April 2005
Resolved
remove/clean lube oil discharged from generators.
Action required: 705 - Other - as specified
Due 21 May 2005
Resolved 21 April 2005
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Overspeed Device
Issued 21 April 2005
Resolved
calibrate/adjust overspeed trips on control panel.
Action required: 705 - Other - as specified
Due 21 June 2005
Resolved 21 April 2006
Fire Fighting › Nozzles › Condition
Issued 21 April 2005
Resolved
Free up firestation 1 hose nozzle.
Action required: 705 - Other - as specified
Due 21 May 2005
Resolved 21 April 2005
Communications › Alarms/Indicators › General Alarm
Issued 21 April 2005
Resolved
place general alarm...report to station.... signs as appropriate.
Action required: 705 - Other - as specified
Due 21 May 2005
Resolved 24 April 2005
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 21 April 2005
Resolved
Fire and escape plan needs to be USCG approved and stamped and old plans need to be removed.
Action required: 705 - Other - as specified
Due 21 June 2005
Resolved 4 August 2005
Fire Fighting › Means of Escape › Doorways
Issued 21 April 2005
Resolved
Repair roll down door at patron ramp.
Action required: 705 - Other - as specified
Due 21 May 2005
Resolved 10 May 2005
Communications › Audible Communications › SPD (Other)
Issued 21 April 2005
Resolved
have all AEVADS areas working properly.
Action required: 705 - Other - as specified
Due 21 June 2005
Resolved 21 April 2006
Electrical › Electric Generation Source (emergency) › Overcurrent Device
Issued 22 April 2004
Resolved
Replace solenoid on trip.
Due 22 May 2004
Resolved 22 April 2004
Resolution: Contractor replaced solinoid.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 22 April 2004
Resolved
Replace out of date and under presure extinguisher.
Due 22 April 2004
Resolved 22 April 2004
Resolution: Extinguisher replaced.
Fire Fighting › Ventilation Systems › Ducts
Issued 22 April 2004
Resolved
Replace fire damper handle 1-21.
Due 22 April 2004
Resolved 22 April 2004
Resolution: Handle replaced.
Stability › Watertight Integrity
Issued 24 April 2003
Resolved
Vesel was missing 2 bulkhead penetrations for eletrical wiring. LEGACY COMPONENT DESC: Bulhead penetrations
Condition: Improper Installation
Due 24 May 2003
Resolved 24 April 2003
Fire Fighting › Structural Fire Protection - General
Issued 24 April 2003
Resolved
Fire Doors on 2nd level were blocked by boxes, which prevented them from closing. LEGACY COMPONENT DESC: Fire Doors
Condition: Placed in Improper Service
Due 24 April 2003
Resolved 24 April 2003
Resolution: Office personnel were briefed on the severity of the issue and the boxes were immediately removed form the vessel.
Electrical › Electric Supply System (service)
Issued 22 October 2002
Resolved
Permanently wire toki lights, entertainment system and phones in texas deck electrical room. LEGACY COMPONENT DESC: Cable
Due 6 January 2003
Resolved 22 October 2002
Accommodation/Occupational Safety › Messroom
Issued 22 October 2002
Resolved
Clean break rooms.
Due 6 January 2003
Resolved 22 October 2002
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 22 October 2002
Resolved
Bolt down refers in break rooms.
Due 6 January 2003
Resolved 22 October 2002
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 22 October 2002
Resolved
Secure refers in break rooms.
Due 6 January 2003
Resolved 22 October 2002
Accommodation/Occupational Safety › Refrigeration (air conditioning)
Issued 22 October 2002
Resolved
repair leak in AC duct frame 17-24.
Due 6 January 2003
Resolved 22 October 2002
Engineering › Diesel Engine (propulsion-electric)
Issued 22 October 2002
Resolved
Repair head gaskets causing oil in water. LEGACY COMPONENT DESC: Cylinder Head
Due 6 January 2003
Resolved 22 October 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 22 October 2002
Resolved
Repair leaking packing in fuel oil transfer pump. LEGACY COMPONENT DESC: Pump
Due 6 January 2003
Resolved 22 October 2002
Electrical › Electric Generation Source (emergency)
Issued 22 October 2002
Resolved
Repair or replace radiator for emergency generator.
Due 6 January 2003
Resolved 22 October 2002
Electrical › Electric Supply System (service)
Issued 22 October 2002
Resolved
replace junction box cover in compartment aft of Island Gold. LEGACY COMPONENT DESC: Cable
Due 6 January 2003
Resolved 22 October 2002
Fire Fighting › Miscellaneous Items
Issued 22 October 2002
Resolved
Replace handle on fire damper closer rod 2-4.
Due 6 January 2003
Resolved 22 October 2002
Electrical › Electric Supply System (service)
Issued 22 October 2002
Resolved
Properly dead end wires throught the ship. LEGACY COMPONENT DESC: Cable
Due 6 January 2003
Resolved 22 October 2002
Electrical › Electric Supply System (service)
Issued 22 October 2002
Resolved
Properly hang wires throughout the ship. LEGACY COMPONENT DESC: Cable
Due 6 January 2003
Resolved 22 October 2002
Electrical › Electric Supply System (service)
Issued 22 October 2002
Resolved
Properly dead end wiring from starboard elevator controller. LEGACY COMPONENT DESC: Cable
Due 6 January 2003
Resolved 22 October 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 22 October 2002
Resolved
Clean (remove hydraluic oil) Port Elevator room.
Due 6 January 2003
Resolved 22 October 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 22 October 2002
Resolved
Secure work station 36, 27, and 28, as well as the "Big 6" wheel.
Due 6 January 2003
Resolved 22 October 2002
Engineering › Shafting/Propeller Arrangements
Issued 22 October 2002
Resolved
Replace rotted boards in paddle wheel.
Due 6 January 2003
Resolved 22 October 2002
Engineering › Shafting/Propeller Arrangements
Issued 22 October 2002
Resolved
Remove sea growth from paddle wheels.
Due 6 January 2003
Resolved 22 October 2002
Stability › Weathertight Integrity
Issued 22 October 2002
Resolved
Route antenna wire through rox blocks in pilot house rather than through window.
Due 6 January 2003
Resolved 22 October 2002
Electrical › Electric Supply System (service)
Issued 24 April 2002
Resolved
Remove dead ended wiring to compressor unit located ouboard on the stern bulkhead of the Texas Deck. LEGACY COMPONENT DESC: Cable
Due 24 May 2002
Resolved 24 May 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 24 April 2002
Resolved
Permenantly mount workstaion near fire door #45.
Due 24 May 2002
Resolved 24 May 2002
Deck/Cargo › Mooring/Anchoring
Issued 24 April 2002
Resolved
Fix or submit proposal to remove mooring winches, port side aft. LEGACY COMPONENT DESC: Capstan
Due 24 May 2002
Resolved 24 May 2002
Engineering › Non-conventional Propulsion/Steering
Issued 24 April 2002
Resolved
Replace missing and rotted boards on paddel wheel.
Condition: Improper/Lack of Maintenance
Due 24 May 2002
Resolved 24 May 2002
Engineering › Non-conventional Propulsion/Steering
Issued 24 April 2002
Resolved
Remove sea growth from paddle wheels.
Due 24 May 2002
Resolved 24 May 2002
Engineering › Feedwater/Condensate Water System
Issued 24 April 2002
Resolved
Replace missing bolts in sea chest.
Due 24 May 2002
Resolved 24 May 2002
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 24 April 2002
Resolved
Mount refers in crews lounge.
Due 24 May 2002
Resolved 24 May 2002
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 24 April 2002
Resolved
Install drains for refers in crews lounge.
Due 24 May 2002
Resolved 24 May 2002
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 24 April 2002
Resolved
replace extinguisher or bracket so that the 2 match. LEGACY COMPONENT DESC: Mounting Bracket
Due 24 May 2002
Resolved 24 May 2002
Fire Fighting › Means of Escape
Issued 24 April 2002
Resolved
Mount sewage hose so it does not block escape from engine room.
Due 24 May 2002
Resolved 24 May 2002
Construction/Loadline › Penetrations
Issued 24 April 2002
Resolved
Provide approved drawing for shore tie mounting box outboard starboard bulkhead of SCR room. LEGACY COMPONENT DESC: Weld
Due 24 May 2002
Resolved 24 May 2002
Construction/Loadline › Structures
Issued 24 April 2002
Resolved
Repair or replace door jamb to slot tech room. LEGACY COMPONENT DESC: Door
Due 24 May 2002
Resolved 24 May 2002
Stability › Watertight Integrity
Issued 24 April 2002
Resolved
Repair port side watertight door to comply with ASTM F-1196 and ABS 5-7-2-9.15.
Due 24 May 2002
Resolved 24 May 2002
Electrical › Electric Supply System (service)
Issued 24 April 2002
Resolved
Route wires correctly through ROX blocks forward bulkhead of passageway forward of slot tech room LEGACY COMPONENT DESC: Cable
Due 24 May 2002
Resolved 24 May 2002
Electrical › Electric Supply System (service)
Issued 24 April 2002
Resolved
Repair wiring in slot tech room. LEGACY COMPONENT DESC: Cable
Due 24 May 2002
Resolved 24 May 2002
Accommodation/Occupational Safety › Ventilation
Issued 24 April 2002
Resolved
Repair blower in slot tech room.
Due 24 May 2002
Resolved 24 May 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 24 April 2002
Resolved
Replace Eye wash bottle in deck stowage.
Due 24 May 2002
Resolved 24 May 2002
Lifesaving › Inflatable Liferafts
Issued 24 April 2002
Resolved
Remove placards and stencils for liferafts that have been removed. LEGACY COMPONENT DESC: Markings
Due 24 May 2002
Resolved 24 May 2002
Electrical › Electrical Distribution System (service)
Issued 24 April 2002
Resolved
ensure wiring in AC handling room complies with sub chapter "J". LEGACY COMPONENT DESC: Cable
Due 24 May 2002
Resolved 24 May 2002
Stability › Watertight Integrity
Issued 24 April 2002
Resolved
Replace bolts in hatch to #3 void.
Due 24 May 2002
Resolved 24 May 2002
Electrical › Lighting (emergency)
Issued 24 April 2002
Resolved
Repair broken "E" fixture in crews lounge. LEGACY COMPONENT DESC: Lighting Fixture
Due 24 May 2002
Resolved 24 May 2002
Communications › Internal Communications System
Issued 24 April 2002
Resolved
Repair comms to rudder room. LEGACY COMPONENT DESC: Sound-powered Telephone
Due 24 May 2002
Resolved 24 May 2002
Electrical › Electrical Distribution System (service)
Issued 24 April 2002
Resolved
replace junction box with one that complies with sub chapter "J". LEGACY COMPONENT DESC: Junction Box
Due 24 May 2002
Resolved 24 May 2002
Accommodation/Occupational Safety › Potable Water System
Issued 24 April 2002
Resolved
Repair faucet in forward hold mens head.
Due 24 May 2002
Resolved 24 May 2002
Fire Fighting › Means of Escape
Issued 24 April 2002
Resolved
Inspect all fire doors for correct operation. LEGACY COMPONENT DESC: Doorways
Due 24 May 2002
Resolved 24 May 2002
Construction/Loadline › Structures
Issued 24 April 2002
Resolved
Provide documentation of current elevator test and inspection IAW ABS publication #16. LEGACY COMPONENT DESC: Trunk
Due 24 May 2002
Resolved 24 May 2002
Documentation › Manuals/Policy Documentation
Issued 24 April 2002
Resolved
Make available original SEILOD proposal and findings.
Due 24 May 2002
Resolved 24 May 2002
Fire Fighting › Combustible Materials
Issued 17 April 2002
Resolved
Remove 85 cardboard boxes of records from audit room.
Due 24 May 2002
Resolved 24 May 2002
Lifesaving
Issued 5 November 2001
Resolved
Replace port side midship main deck lifering.
Condition: Unknown
Due 5 December 2001
Resolved 5 November 2001
Electrical
Issued 5 November 2001
Resolved
Dead end exposed wires in Service Bar ceiling electrical box overhead.
Condition: Unknown
Due 5 December 2001
Resolved 21 October 2002
Fire Fighting
Issued 5 November 2001
Resolved
Repair/replace damper 1-13 at aft main deck port side.
Condition: Unknown
Due 5 December 2001
Resolved 21 October 2002
Lifesaving
Issued 5 November 2001
Resolved
Replace battery in port side light for lifering.
Condition: Unknown
Due 5 December 2001
Resolved 5 November 2001
Fire Fighting
Issued 5 November 2001
Resolved
Repair/replace exit doors #'s 79,80,81,95,56 and fire door on Texas deck.
Condition: Unknown
Due 5 December 2001
Resolved 21 October 2002
Fire Fighting
Issued 5 November 2001
Resolved
Repair/replace fire station no. 12 fire nozzle.
Condition: Unknown
Due 5 December 2001
Resolved 21 October 2002
Engineering
Issued 7 May 2001
Resolved
Repair/replace insulation around piping in emergency generator room.
Condition: Unknown
Due 18 May 2001
Resolved 18 May 2001
Fire Fighting
Issued 7 May 2001
Resolved
Repair/replace faulty sensor for fire system 3.
Condition: Unknown
Due 14 May 2001
Resolved 18 May 2001
Lifesaving
Issued 7 May 2001
Resolved
Provide emergency escape ladder/device for stage area on starboard texas deck.
Condition: Unknown
Due 7 May 2001
Resolved 7 May 2001
Lifesaving
Issued 7 May 2001
Resolved
Replace and stencil life rings.
Condition: Unknown
Due 17 May 2001
Resolved 18 May 2001
Fire Fighting
Issued 7 May 2001
Resolved
Manual operating instructions need to be updated for fixed systems.
Condition: Unknown
Due 7 May 2001
Resolved 7 May 2001
Deck/Cargo
Issued 7 May 2001
Resolved
Load test employee boom.
Condition: Unknown
Due 16 May 2001
Resolved 18 May 2001
Fire Fighting
Issued 7 May 2001
Resolved
Replace/repair emergency generator room smoke sensor.
Condition: Unknown
Due 18 May 2001
Resolved 18 May 2001
Fire Fighting
Issued 13 February 2001
Resolved
Verify proper operation of all vent dampers for emergency generator room.
Condition: Unknown
Due 13 February 2001
Resolved 13 February 2001
Accommodation/Occupational Safety
Issued 13 February 2001
Resolved
Replace or repair exit doors Aft port door main deck, second deck port forward, texas deck fwd stairwell door.
Condition: Unknown
Due 13 February 2001
Resolved 13 February 2001
Electrical
Issued 13 February 2001
Resolved
Replace rubber boot and properly mount exhaust fan in emergency generator room.
Condition: Unknown
Due 13 February 2001
Resolved 13 February 2001
Electrical
Issued 17 August 2000
Resolved
Repair communication system in portside elevator (Fr 36-41)._x001C_ _x001C_ System is overriden by office faxes when in secondary mode (telephone system back-up)
Condition: Unknown
Due 17 August 2000
Resolved 17 August 2000
Fire Fighting
Issued 17 August 2000
Resolved
Adjust Fire Screen Doors #5 and #16 (hinges)_x001C_ Adjust Fire Screen Door #9 (latch)
Condition: Unknown
Due 17 August 2000
Resolved 17 August 2000
Electrical
Issued 9 May 2000
Resolved
Properly tag and lock out (or remove and blank) main breaker for air handler #8. Breaker is located on the main switchboard in the engineering control room.
Condition: Unknown
Due 29 May 2000
Resolved 29 May 2000
Engineering
Issued 9 May 2000
Resolved
Install treaded plugs in ball valves located on the bottom of all 12 racor fuel filters.
Condition: Unknown
Due 29 May 2000
Resolved 29 May 2000
Engineering
Issued 8 February 2000
Resolved
Make proper repairs to starboard side paddlewheel's outboard shaft bearing.Seal is leaking.
Condition: Unknown
Due 9 March 2000
Resolved 9 March 2000
Construction/Loadline
Issued 8 February 2000
Resolved
Repair defective weld, located in the forward bow-thruster tunnel.
Condition: Unknown
Due 8 February 2000
Resolved 8 February 2000
Fire Fighting
Issued 9 November 1999
Resolved
Provide proof of hydro for all eight portable CO2 fire extinguishers. Due date 11/99.
Condition: Unknown
Due 9 November 1999
Resolved 9 November 1999
Lifesaving
Issued 9 November 1999
Resolved
Properly secure and store spare gaming tables and chairs located on the Texas deck.
Condition: Unknown
Due 16 November 1999
Resolved 16 November 1999
Electrical
Issued 9 November 1999
Resolved
Remove or provide juntion box for wire leading into electrical panel located in the main deck electrical room.
Condition: Unknown
Due 16 November 1999
Resolved 16 November 1999
Electrical
Issued 9 November 1999
Resolved
Secure the two electronic racks located in the electrical room on Texas deck and remove the 10 outlet extension card and provide plans for hard wiring.
Condition: Unknown
Due 9 November 1999
Resolved 9 November 1999
Accommodation/Occupational Safety
Issued 9 November 1999
Resolved
Repair the main drain piping for the main deck drains and beverage bar sinkdrains. Piping runs through the Aux room, engine room and aft void to draininto the aft lift station.
Condition: Unknown
Due 9 November 1999
Resolved 9 November 1999
Accommodation/Occupational Safety
Issued 9 November 1999
Resolved
Secure the three gaming tables in the high roller section on the 2nd deck. Tables were not secured to the deck.
Condition: Unknown
Due 16 November 1999
Resolved 16 November 1999
Electrical
Issued 10 August 1999
Resolved
REMOVE OR INSTALL JUNCTION BOXES ON FOUR SETS OF DEAD END WIRES LOCATED_x001C_ AFTER BULKHEAD IN THE MOTOR ROOM STORAGE COMPARTMENT.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Lifesaving
Issued 10 August 1999
Resolved
PROVIDE LIFE RAFT LUNCHING INSTRUCTIONS AT ALL FOUR EMBARKATION STATIONS. EXSISTING INSTRUCTIONS WERE FADED.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Lifesaving
Issued 10 August 1999
Resolved
PROVIDE FOR TEN PRECENT OF CHILD SIZE LIFE PERSERVERS. (SEE MINS FOR DETAILS)
Condition: Unknown
Due 10 September 1999
Resolved 14 September 1999
Fire Fighting
Issued 16 March 1999
Resolved
Repair closure mechanisms to fire dampers. (#1-13, handle cog stripped; _x001C_ #1-15, handle broken)
Condition: Unknown
Due 16 March 1999
Resolved 2 April 1999
Lifesaving
Issued 16 March 1999
Resolved
Reattach recessed ceiling framing supporting ceiling tiles over aft slot room, main deck, stbd.
Condition: Unknown
Due 16 March 1999
Resolved 2 April 1999
Engineering
Issued 9 December 1998
Resolved
Make permanent repairs to remote "Z" drive thruster control located on portbridgewing station.
Condition: Unknown
Due 9 December 1998
Resolved 9 December 1998
Electrical
Issued 9 December 1998
Resolved
Replace missing rubber mat located behind emergency generator power panel.
Condition: Unknown
Due 9 January 1999
Resolved 30 December 1998
Deck/Cargo
Issued 9 December 1998
Resolved
Provide permanent "hard wiring" to bow rescue boat hoisting winch.
Condition: Unknown
Due 9 December 1998
Resolved 9 December 1998
Engineering
Issued 9 December 1998
Resolved
Make permanent repairs to EOT located in pilothouse.
Condition: Unknown
Due 9 December 1998
Resolved 9 December 1998
Engineering
Issued 9 December 1998
Resolved
Paint "bulls eye" and stencil, in contrasting colors to surrounding area, location of fuel cutoff to emergency generator and direction of motion.
Condition: Unknown
Due 9 December 1998
Resolved 9 December 1998
Lifesaving
Issued 9 December 1998
Resolved
Remove excess cleaning and gaming supplies stored on third deck.
Condition: Unknown
Due 9 December 1998
Resolved 9 December 1998
Lifesaving
Issued 3 September 1998
Resolved
Excess consummables (piping, filters, welding equipt, etc) not stored away.
Condition: Unknown
Due 3 September 1998
Resolved 3 September 1998
Engineering
Issued 3 September 1998
Resolved
Lagging to keel cooler piping in way of #4,5,6 generators removed, requiring re-installation.
Condition: Unknown
Due 3 September 1998
Resolved 3 September 1998
Engineering
Issued 3 September 1998
Resolved
Containment trunks to fuel vent missing plug
Condition: Unknown
Due 3 September 1998
Resolved 29 September 1998
Lifesaving
Issued 3 September 1998
Resolved
Coffee machine, located in 2nd deck fwd servcie bar, not secured
Condition: Unknown
Due 3 September 1998
Resolved 29 September 1998
Accommodation/Occupational Safety
Issued 3 September 1998
Resolved
Aft access/emergency exit to main deck credit office contained storage equipt affecting egress.
Condition: Unknown
Due 3 September 1998
Resolved 29 September 1998
Accommodation/Occupational Safety
Issued 3 September 1998
Resolved
Inadequate hose drain utilized in way of second deck main bar
Condition: Unknown
Due 3 September 1998
Resolved 29 September 1998
Fire Fighting
Issued 19 May 1998
Resolved
Renew relief valve on sprinkler tank to relieve below MAWP of tank.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Fire Fighting
Issued 19 May 1998
Resolved
Test engineroom CO2 shutdown & time delays.
Condition: Unknown
Due 19 June 1998
Resolved 30 June 1998
Construction/Loadline
Issued 19 May 1998
Resolved
Reinstall wedges on weather doors to SCR space on stbd side.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Lifesaving
Issued 19 May 1998
Resolved
Eliminate safety hazards on Texas deck bulkheads (insulation hanger project1 1/2 inches past insulation).
Condition: Unknown
Due 19 June 1998
Resolved 30 June 1998
Engineering
Issued 19 May 1998
Resolved
Repair & reinstall port paddle wheel gear drive & reinstall paddle wheel.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Engineering
Issued 16 April 1998
Resolved
Repair "GE Fanuc" Engineroom Control Monitor. (one of two)
Condition: Unknown
Due 16 April 1998
Resolved 16 April 1998
Electrical
Issued 10 March 1998
Resolved
Remove "power strip" extension cords & provide permanently installed outlets in following spaces: Change Cages, Soft & Hard Count, DCU, Surveillance.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Accommodation/Occupational Safety
Issued 10 March 1998
Resolved
Provide metal covers for plastic coin holders' metal bin.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Fire Fighting
Issued 10 March 1998
Resolved
Install mount for portable fire extinguisher in soft count space.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Construction/Loadline
Issued 10 March 1998
Resolved
Remove excessive combustable material stored in Soft Count, Hard Count, & DCU spaces.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Accommodation/Occupational Safety
Issued 10 March 1998
Resolved
Remove excessive plastic from cart storage areas (fire load).
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Lifesaving
Issued 27 August 1997
Resolved
Secure drill press in AHR
Condition: Unknown
Due 27 August 1997
Resolved 27 August 1997
Accommodation/Occupational Safety
Issued 27 August 1997
Resolved
SECURE "CASH LINK" MACHINES ON MAIN AND 2ND DECK
Condition: Unknown
Due 27 August 1997
Resolved 27 August 1997
Fire Fighting
Issued 27 August 1997
Resolved
LABLE FIRE DAMPER CONTROL (STARWAY 5) TO OUTSIDE OF ENTRY DOOR
Condition: Unknown
Due 27 August 1997
Resolved 27 August 1997
Electrical
Issued 27 August 1997
Resolved
REMOVE EXTENSION CORD TO COMPRESSOR IN BAR STORAGE MAIN DECK FORWARD
Condition: Unknown
Due 27 August 1997
Resolved 27 August 1997
Lifesaving
Issued 27 August 1997
Resolved
REPLACE COMBUSTABLE CABNET (SLOT HOSTESS) WITH METAL CABNET & PROPERLY SECURE IN PLACE. IWO MAIN DECK
Condition: Unknown
Due 27 August 1997
Resolved 27 August 1997
Lifesaving
Issued 27 August 1997
Resolved
INSTALL GUARD ON DRIVE FOR PADDEL WHEEL
Condition: Unknown
Due 27 August 1997
Resolved 27 August 1997
Electrical
Issued 27 August 1997
Resolved
REPLACE ELECTRICAL OUTLETS UNDER BAR SERVICE SINKS WITH GFI OUTLET
Condition: Unknown
Due 27 August 1997
Resolved 27 August 1997
Electrical
Issued 27 August 1997
Resolved
REMOVE OR INSTALL FIXTURES ON DEAD ENDED WIRE IN Z DRIVE SPACE IWO Z DRIVES
Condition: Unknown
Due 27 August 1997
Resolved 27 August 1997
Electrical
Issued 27 August 1997
Resolved
INSTALL FACEPLATE ON ELECTRONICS BOX IWO SERVICE BAR, MAIN DECK AFT
Condition: Unknown
Due 27 August 1997
Resolved 27 August 1997
Electrical
Issued 27 May 1997
Resolved
DAMAGE WIRE AT STUFFING TUBE ON MAIN DECK FORWARD WEATHERDECK IWO CENTERLINE STANCHION.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Construction/Loadline
Issued 27 May 1997
Resolved
REPAINT DRAFT MARKS
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Construction/Loadline
Issued 27 May 1997
Resolved
MANHOLE COVER IN BOW THRUSTER ROOM TO CHAIN LOCKER NOT SECURED.
Condition: Unknown
Due 27 June 1997
Resolved 6 July 1997
Fire Fighting
Issued 27 May 1997
Resolved
MAKE REPAIRS / MODIFICATION TO #1 SPRINKLER & #1 FIRE PUMP SUCTION LINE - PUMPS WILL NOT TAKE PRIME AUTOMATICALLY.
Condition: Unknown
Due 26 June 1997
Resolved 6 July 1997
Electrical
Issued 27 May 1997
Resolved
CLEAR 5 AMP GROUND ON 208VAC SYSTEM LOCATED IN AC&R SPACE_x001C_
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Deck/Cargo
Issued 27 May 1997
Resolved
ANCHOR WINDLASS DRIVE SHAFT FRACTURED AT UPPER SPLINE.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Fire Fighting
Issued 17 March 1997
Resolved
Investigate and make proper repairs to third deck pull stations. Pull stations do not initiate alarms to ring.
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Electrical
Issued 17 March 1997
Resolved
Provide "blank-out" covers for electrical breaker boxes._x001C_ _x001C_
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Electrical
Issued 17 March 1997
Resolved
2nd deck bar fwd - Remove extgension cord to mini-compressor, provide electrical outlet.
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Construction/Loadline
Issued 17 March 1997
Resolved
Ensure all hose thru-deck/bulkhead penetrations located in bar service areas are adaquately protected; thermal insulation, stuffing, ect._x001C_
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Accommodation/Occupational Safety
Issued 17 March 1997
Resolved
Repair access door to port elevator telephone box.
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Lifesaving
Issued 17 March 1997
Resolved
Provide adaquate storage for refreshment bottles against motion._x001C_
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Lifesaving
Issued 17 March 1997
Resolved
Remove and prevent coin cart stowage outside 2nd deck cage
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Electrical
Issued 17 March 1997
Resolved
2nd deck fwd bar - Replace missing phone jack cover located near ice machine
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Lifesaving
Issued 17 March 1997
Resolved
Properly secure equipment and tables in crew's break room
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Lifesaving
Issued 9 December 1996
Resolved
Provide cover for electrical outlet in food service bar. Remove surge protector extension cord.
Condition: Unknown
Due 9 December 1996
Resolved 9 December 1996
Lifesaving
Issued 9 December 1996
Resolved
Provide cover for electrical outlet in electronics room.
Condition: Unknown
Due 9 December 1996
Resolved 9 December 1996
Electrical
Issued 9 December 1996
Resolved
Provide cover for electrical distribution panel EP213
Condition: Unknown
Due 9 December 1996
Resolved 9 December 1996
Electrical
Issued 9 December 1996
Resolved
Provide electrical breaker index card for distribution panel EP205
Condition: Unknown
Due 9 December 1996
Resolved 9 December 1996
Fire Fighting
Issued 9 December 1996
Resolved
Provide lead seals for hose reel systems in engineroom and bow thruster room.
Condition: Unknown
Due 9 December 1996
Resolved 9 December 1996
Construction/Loadline
Issued 9 December 1996
Resolved
Repair powered WTD #1. System will not close door with power secured.
Condition: Unknown
Due 9 December 1996
Resolved 9 December 1996
Engineering
Issued 21 October 1996
Resolved
MAKE PERMANENT REPAIRS TO Z-DRIVE SYSTEM TO SATISFACTION OF ATTENDING INSPECTOR. AT NO TIME WILL VSL GET U/W WITH LESS THAN ONE OPERABLE Z-DRIVEUNIT.
Condition: Unknown
Due 28 October 1996
Resolved 30 October 1996
Electrical
Issued 9 September 1996
Resolved
REPAIR "SECTION A" GROUND DETECTION SYSTEM ON MAIN SWITCHBOARD
Condition: Unknown
Due 16 September 1996
Resolved 23 September 1996
Electrical
Issued 9 September 1996
Resolved
VERIFY PROPER OPERATION OF ALL EMERGENCY LIGHTING
Condition: Unknown
Due 9 September 1996
Resolved 23 September 1996
Fire Fighting
Issued 9 September 1996
Resolved
RENEW EMERGENCY SPRINKLER PUMP PRESSURE GUAGE
Condition: Unknown
Due 9 September 1996
Resolved 9 September 1996
Lifesaving
Issued 9 September 1996
Resolved
REPLACE 3RD DECK LIFERING STROBE LT
Condition: Unknown
Due 16 September 1996
Resolved 14 November 1996
Electrical
Issued 9 September 1996
Resolved
REPAIR LOW PRESSURE LUBE OIL ALARM ON #4 MDEG
Condition: Unknown
Due 16 September 1996
Resolved 23 September 1996
Electrical
Issued 9 September 1996
Resolved
TROUBLESHOOT SYSTEM AND IDENTIFY REQUIRED REPAIRS PRIOR TO GETTING UNDERWAY. VERIFY PROPER OPERATION IN MANUAL MODE. EMERGENCY GENERATOR ROOMTO BE MANNED AT ALL TIMES WHILE PASSENGERS ARE ABOARD.
Condition: Unknown
Due 9 September 1996
Resolved 23 September 1996
Lifesaving
Issued 9 September 1996
Resolved
VERIFY PROPER OPERATION OF ALL EMERGENCY ALARM BELLS
Condition: Unknown
Due 22 September 1996
Resolved 14 November 1996
Electrical
Issued 9 September 1996
Resolved
REPAIR EMERGENCY SWITCHBOARD BREAKER PRIOR TO GETTING UNDERWAY._x001C_
Condition: Unknown
Due 9 September 1996
Resolved 23 September 1996
Construction/Loadline
Issued 9 September 1996
Resolved
PROVIDE DOGGING WRENCH FOR WTD TO Z-DRIVE/STERRING GEAR ROOM.
Condition: Unknown
Due 16 September 1996
Resolved 14 November 1996
Fire Fighting
Issued 20 June 1996
Resolved
CONDUCT FIRE, BOAT, AND EVACUATION DRILLS FOR THIRD CREW PRIOR TO GOING ON WATCH.
Condition: Unknown
Due 9 July 1996
Resolved 16 July 1996
Navigation
Issued 23 May 1995
Resolved
REPAIR AND PROVE OPERATION OF SOUND POWERED TELEPHONE IN STEERING ROOM.
Condition: Unknown
Due 23 May 1995
Resolved 23 May 1995
Construction/Loadline
Issued 23 May 1995
Resolved
ADJUST ALARM SWITCH ON WTD #2. REPAIR AND PROVE OPERATION OF WTD #2 AND #3HYDRAULIC SYSTEM. BOTH PUMPS ARE CYCLING TO OFTEN TO MAINTAIN PRESSURE.
Condition: Unknown
Due 23 May 1995
Resolved 23 May 1995
Fire Fighting
Issued 23 May 1995
Resolved
REPAIR AND PROVE OPERATION OF SPRINKLER SYSTEM SEA VALVE TAMPER SWITCH AND ASSOCIATED ALARM IN WHEEL HOUSE.
Condition: Unknown
Due 23 May 1995
Resolved 23 May 1995
Construction/Loadline
Issued 23 May 1995
Resolved
INSTALL EIGHT MISSING DIAGONAL BEAMS IN AMR AS PER APPROVED DWG -360CS-001-100-10 REV C.
Condition: Unknown
Due 23 May 1995
Resolved 23 May 1995
Fire Fighting
Issued 24 March 1995
Resolved
Provide periodic test procedure required by NFPA-72 section 7 as applicable.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Fire Fighting
Issued 24 March 1995
Resolved
Provide periodic test procedure for the sprinkler system IAW NFPA-25, Chapter 2.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Electrical
Issued 24 March 1995
Resolved
Provide approved periodic safety test procedure for vital system automationIAW 46CFR 61.40.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Fire Fighting
Issued 24 March 1995
Resolved
Provide Coast Guard approval for the use of the ZN-34U module currently being used by Pyrotronics System 3, per MSC ltr P000463 dtd 17MAR95 or replace same with approved item.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Engineering
Issued 8 February 1995
Resolved
SATISFY COMMENT (1) OF MSC LTR E2-9500583 DTD 08FEB95. ITEM 6.3 OF F.M.E.A. PROP. SYS. DWG 360CS-001-835-34 REV. C FOR THROTTLE REFERENCE SIGNAL.
Condition: Unknown
Due 8 February 1995
Resolved 8 February 1995
Documentation
Issued 8 February 1995
Resolved
RESOLVE ABS OUTSTANDING ITEM ON TORSIONAL VIBRATION ANALYSIS.
Condition: Unknown
Due 8 February 1995
Resolved 8 February 1995
Engineering
Issued 8 February 1995
Resolved
PROVIDE MONITORING DEVICES FOR GENERATOR EXHAUST TEMPERATURE AND FUEL OIL PRESSURE, AND FUEL OIL PRESSURE ALARMS FOR GENERATORS IAW ABS TABLE 41.1 AND 46 CFR 62.35-50 AND -20(b).
Condition: Unknown
Due 8 February 1995
Resolved 8 February 1995
Documentation
Issued 8 February 1995
Resolved
PROVIDE [name withheld] MOORING AND ANCHOR ARRANGEMENT PLANS 360CS-001-582-02 AND -835-59 (ANCHOR CALCULATIONS).
Condition: Unknown
Due 8 February 1995
Resolved 8 February 1995
Documentation
Issued 8 February 1995
Resolved
PROVIDE [name withheld] FIRE AND SMOKE DETECTION ZONE PLAN 360CS-001-436-05 REV. A.
Condition: Unknown
Due 8 February 1995
Resolved 8 February 1995
Documentation
Issued 8 February 1995
Resolved
RESOLVE ABS OUTSTANDING ITEM ON ELECTRIC CABLE CERTIFICATION.
Condition: Unknown
Due 8 February 1995
Resolved 8 February 1995
Documentation
Issued 8 February 1995
Resolved
RESOLVE ABS OUTSTANDING ITEM ON ELEVATOR INSTALLATION.
Condition: Unknown
Due 8 February 1995
Resolved 8 February 1995
Navigation
Issued 8 February 1995
Resolved
PROVIDE MANEUVERING INFO IAW 33 CFR 164.35(g).
Condition: Unknown
Due 8 February 1995
Resolved 8 February 1995
Documentation
Issued 8 February 1995
Resolved
PROVIDE CERTIFICATE OF DOCUMENTATION; VESSEL PROHIBITED FROM ENGAGING IN COASTWISE TRADE UNTIL SATISFIED.
Condition: Unknown
Due 8 February 1995
Resolved 8 February 1995
Engineering
Issued 8 February 1995
Resolved
PROVIDE APPROVED PERIODIC SAFETY TEST PROCEDURE FOR VITAL SYSTEM AUTOMATIONIAW 46 CFR 61.40.
Condition: Unknown
Due 8 February 1995
Resolved 8 February 1995
Documentation
Issued 8 February 1995
Resolved
CONDUCT USCG WITNESSED DEADWEIGHT SURVEY AND PROVIDE/POST MSC ISSUED STABILITY LETTER FOR 2,500 TOTAL PERSONS.
Condition: Unknown
Due 8 February 1995
Resolved 8 February 1995
Documentation
Issued 8 February 1995
Resolved
CONDUCT AND LOG CREW DRILLS AND REQUIRED TRAINING, I.E. FIRE AND BOAT DRILLS, TO THE SATISFACTION OF [name withheld].
Condition: Unknown
Due 8 February 1995
Resolved 8 February 1995
Documentation
Issued 8 February 1995
Resolved
PROVE VESSEL HAS SATISFACTORY FIRELOAD CHARACTERISTICS IAW MSC LTR _x001C_ H2-9500297 DTD 25JAN95 TO [name withheld].
Condition: Unknown
Due 8 February 1995
Resolved 8 February 1995
Engineering
Issued 8 February 1995
Resolved
PROVIDE AUDIBLE AND VISUAL ALARMS IN THE MACHINERY SPACES; ROTATING BEACONSMUST BE PAIRED WITH AUDIBLE DEVICES IAW 46 CFR 62.25-20(d)(2) and (e).
Condition: Unknown
Due 27 February 1995
Resolved 27 February 1995
Documentation
Issued 8 February 1995
Resolved
PROVIDE [name withheld] LIFESAVING EQUIPMENT PLAN; 360CS-001-583-04 REV. D.
Condition: Unknown
Due 8 February 1995
Resolved 8 February 1995
Engineering
Issued 8 February 1995
Resolved
ENTRY ERROR - DISREGARD.
Condition: Unknown
Due 1 April 1995
Resolved 30 March 1995
Lifesaving
Issued 8 February 1995
Resolved
DEMONSTRATE LIFESAVING EQUIPMENT IS AS PER APPROVED PLAN; I.E. ARRANGEMENT,STOWAGE, ETC.
Condition: Unknown
Due 8 February 1995
Resolved 8 February 1995
Documentation
Issued 8 February 1995
Resolved
PROVIDE [name withheld] FIRE AND SAFETY PLAN 360CS-001-835-12 REV. C.
Condition: Unknown
Due 8 February 1995
Resolved 8 February 1995
Accommodation/Occupational Safety
Issued 8 February 1995
Resolved
COMPLETE AND PROVE SATISFACTORY INSTALLATION OF THE BEVERAGE DISTRIBUTION SYSTEM WITH RESPECT TO STRUCTURAL FIRE PROTECTION (DECK PENETRATIONS).
Condition: Unknown
Due 8 February 1995
Resolved 8 February 1995
Fire Fighting
Issued 8 February 1995
Resolved
DEMONSTRATE FIRE AND SAFETY EQUIPMENT IS AS PER APPROVED PLAN; I.E. LOCATION, PHYSICAL LAYOUT, ETC.
Condition: Unknown
Due 8 February 1995
Resolved 8 February 1995
Electrical
Issued 8 February 1995
Resolved
COMPLETE AND PROVE SATISFACTORY INSTALLATION OF ELECTRICAL WIRING ASSOCIATED WITH THE GAMING AND SURVEILLANCE EQUIPMENT.
Condition: Unknown
Due 8 February 1995
Resolved 8 February 1995
Engineering
Issued 8 February 1995
Resolved
SATISFY COMMENT (2) OF MSC LTR E2-9500583 DTD 08FEB95. PROVIDE APPROVED COPIES OF F.M.E.A. PROPULSION, Z-DRIVE, AND ALARM/MONITORING SYSTEM ABOARD VESSEL.
Condition: Unknown
Due 8 February 1995
Resolved 8 February 1995
Engineering
Issued 8 February 1995
Resolved
SATISFY COMMENT (3)(a) OF MSC LTR E2-9500583 DTD 08FEB95. DEMONSTRATE TESTOF ITEM 2.2.19 DLMA-18 DIGITAL I/O CARD FAILURE DWG 360CS-001-835-35 REV. CTO INCLUDE AUDIBLE AND VISUAL ALARM.
Condition: Unknown
Due 8 February 1995
Resolved 8 February 1995
Engineering
Issued 8 February 1995
Resolved
SATISFY COMMENT (3)(b) OF MSC LTR E2-9500583 DTD 08FEB95. DEMONSTRATE TESTOF ITEM 2.2.30 RLSA 3-15 RTD INPUT CARD FAILURE DWG 360CS-001-835-35 REV.C.
Condition: Unknown
Due 8 February 1995
Resolved 8 February 1995
Engineering
Issued 8 February 1995
Resolved
SATISFY COMMENT (4) OF MSC LTR E2-9500583 DTD 08FEB95. DEMONSTRATE PROPULSION UNIT DOES NOT AUTOMATICALLY REGAIN CONTROL UPON RESETTING/RECLOSING TRIPPED SCR CIRCUIT BREAKER FOR Z-DRIVE AND PADDLEWHEELS IAW 46 CFR 62.25-15(e)(2).
Condition: Unknown
Due 8 February 1995
Resolved 8 February 1995
Engineering
Issued 8 February 1995
Resolved
SATISFY COMMENT (5) OF MSC LTR E2-9500583 DTD 08FEB95. PROVE EQUIVALENCY OFSHOTTEL Z DRIVE AZIMUTH FOLLOW-UP STEERING FAILURE SYSTEM TO 46 CFR 113.43 BY PROVIDING MSC APPROVED TEST PROCEDURES, SPECIFICALLY ADDRESSED IN MSC LTR E2-9500226 DTD 02FEB95 COMMENT (8).
Condition: Unknown
Due 8 February 1995
Resolved 8 February 1995
Engineering
Issued 8 February 1995
Resolved
SATISFY COMMENT (12) OF MSC LTR E2-9500266 DTD 02FEB95. RESUBMIT DWG 360CS-001-314-16 PROPULSION DRIVE INTERCONNECTION DIAGRAM FOR APPROVAL.
Condition: Unknown
Due 8 February 1995
Resolved 8 February 1995
Documentation
Issued 8 February 1995
Resolved
SATISFY COMMENT (9) OF MSC LTR E2-9500266 DTD 02FEB95 REGARDING ENVIRONMENTAL DESIGN STANDARDS IN 46 CFR 62.25-30. SEE 46 CFR 62.20-5.
Condition: Unknown
Due 8 February 1995
Resolved 8 February 1995