Records from 1994 to 1995. Most recent: inspection, 5 February 1995.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 5
5 February 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 42321
15 January 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 374252
21 December 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 373634
21 December 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 373701
13 December 1994
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1147175
Construction/Loadline
Issued 15 January 1995
Resolved
REPAINT LOADLINE MARKING PRIOR TO ARRIVING AT NEXT U.S. PORT.
Condition: Unknown
Due 15 March 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 15 January 1995
Resolved
REPAIR INOPERATIVE STARBOARD RINGBUOY WATERLIGHT PRIOR TO DEPARTING.
Condition: Unknown
Due 15 January 1995
Resolved 23 January 1995
Navigation
Issued 13 December 1994
Resolved
DEMONSTRATE PROPER OPERATION OF NAVIGATION ALARM PANEL FOR STERN LIGHT.
Condition: Unknown
Due 21 June 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 13 December 1994
Resolved
PROVIDE RUDDER ANGLE INDICATOR IN STEERING GEAR COMPARMENT.
Condition: Unknown
Due 21 March 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 13 December 1994
Resolved
PROVIDE NON-CONDUCTIVE MAT FOR EMERGENCY GENERATOR SWITCH BOARD.
Condition: Unknown
Due 21 March 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 13 December 1994
Resolved
INSTALL MISSING LIGHT GLOBES THROUGHOUT THE VESSEL.
Condition: Unknown
Due 21 June 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 13 December 1994
Resolved
DISPLAY BLOCK DIAGRAM FOR STEERING GEAR IN STEERING GEAR COMPARTMENT AS_x001C_ PER 33 CFR 164.35 (k)
Condition: Unknown
Due 21 June 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 13 December 1994
Resolved
PROVIDE SAFETY GUARDS AROUND STEERING GEAR PUMP SHAFTS
Condition: Unknown
Due 21 June 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 13 December 1994
Resolved
INSTALL RELIEF VALVES ON FIRE PUMP EMERGENCY FIRE PUMP AND BALLAST PUMP ANDPROVIDE CLASS REPORT TO COGNIZANT OCMI.
Condition: Unknown
Due 21 June 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 13 December 1994
Resolved
DISPLAY ON BRIDGE, MANEUVERING INFORMATION AS REQUIRED BY 33 CFR 164.35 (g)
Condition: Unknown
Due 21 June 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 13 December 1994
Resolved
PROVIDE SAFETY GUARD AROUND FAN AND BELT DRIVE ASSEMBLY FOR EMERGENCY GENERATOR.
Condition: Unknown
Due 21 March 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 13 December 1994
Resolved
PROVIDE SAFETY GUARD AROUND SHAFT OF EMERGENCY GENERATOR.
Condition: Unknown
Due 21 March 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past