Records from 2002 to 2026. Most recent: inspection, 16 April 2026.
Documentation record
Registered dimensions (L × B × D)115.9 ft × 24.1 ft × 7.1 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMATHEW ANDERSON · OLALLA, WA, UNITED STATES · built 1922
Hull materialWood
PropulsionSteam Reciprocating
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLISABUELLA, WA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 June 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 22
16 April 2026
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8350683
16 September 2025
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8238865
24 January 2025
Internal Structural Exam · Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8069359
24 April 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7900350
23 January 2024
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7856202
30 November 2023
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7831998
13 November 2023
Special Consideration
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7824154
5 October 2023
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7803842
28 April 2023
In-Service Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7677743
25 January 2023
Underwater Inspection in lieu of Drydock
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7627042
3 August 2021
Administrative Inspection · In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7248781
18 February 2021
Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7134326
18 September 2020
Plan Review "T" Boat
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7061090
8 July 2020
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7015189
13 February 2020
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6908452
9 May 2019
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6680398
28 February 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6634092
21 May 2018
Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6422574
27 April 2018
Annual Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6397828
20 April 2017
COI Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6127185
9 January 2017
Administrative Inspection · Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6068081
20 May 2016
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6081110
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 April 2026
Resolved
An adult life jacket must be provided for each person carried on board. Found 60 life jackets to be defective, vessel required 32 extra life jackets in order to operate at full passenger capacity. Vessel limited to no more than 123 persons.
46 CFR 180.71
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 3 June 2026
Resolved 8 May 2026
Resolution: Received email receipts for new lifejackets.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 April 2026
Resolved
Lamp, paint, and oil lockers and similar compartments shall be constructed of metal or lined with metal.
Vessel had no metal paint locker aboard. Require vessel to provide documentation of satisfactory purchased or constructed paint locker or removal of flammable liquids from vessel.
46 CFR 177.10-5(c) (OLD T)
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2026
Resolved 6 May 2026
Resolution: All flammable liquids previously stored on vessel have been removed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 April 2026
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following: Inspection of each portable fire extinguisher, semi-portable fire extinguisher, and fixed gas fire extinguishing system to check for excessive corrosion and general condition. Vessel had one portable extinguisher that had low pressure charge.
46 CFR 176.810
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2026
Resolved 6 May 2026
Resolution: Fire extinguisher recharged. Deficiency closed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 April 2023
Resolved
Low low water level limit control does not shut down the boiler before the water level drops below the lowest level visible in the sight glass. Adjust so that the boiler automatically shuts down while there is still water visible in the sight glass.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 May 2023
Resolved 4 May 2023
Resolution: Cut out set point adjusted and retested sat.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 28 April 2023
Resolved
Fuel pump #1 (fwd) has a badly leaking shaft seal. Two fuel pumps are required. Repair or replace pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 May 2023
Resolved 4 May 2023
Resolution: Pump replaced and tested sat.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 28 April 2023
Resolved
High pressure fuel service piping between the pump and nozzle is leaking in various locations (unions, strainer, etc.). Repair all leaking components in the burner fuel oil service system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 May 2023
Resolved 4 May 2023
Resolution: Leaking piping repaired.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 28 April 2023
Resolved
Remote emergency controls for forced draft fans, fuel oil service pumps, fuel oil transfer pumps, etc. are not provided outside the space concerned as required by 46 CFR 58.01-25. Provide the OCMI with a proposal for the installation of remote shut off controls meeting 46 CFR 111.103.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2023
Resolved 12 June 2023
Resolution: Proposal received.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 28 April 2023
Resolved
Secondary means of escape from the lower level of the engine room, proceeding aft, requires passing over the tail shaft near the shaft seal. At the time of inspection there was no guard in place requiring an individual in egress to straddle a potentially rotating shaft. Provide guard over shaft of suitable strength to support crew members egressing the space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2023
Resolved 12 June 2023
Resolution: Guard installed.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 28 April 2023
Resolved
Remote emergency controls for forced draft fans, fuel oil service pumps, fuel oil transfer pumps, etc. are not provided outside the space concerned as required by 46 CFR 58.01-25. Provide remote shut off controls meeting 46 CFR 111.103 by November 30, 2023.
Action required: 705 - Other - as specified
Due 30 November 2023
Resolved 23 January 2024
Resolution: Tested two shutdowns all sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 27 June 2022
Resolved
A self priming, power driven fire pump must be installed
on each vessel of more than 19.8 meters (65 feet) in length. Vessels electric fire pump was taken out of service and sent to a facility for repairs. Demonstrate proper operation of fire pump prior to carrying passengers.
46 CFR 181.300(a)(iii)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2022
Resolved 8 July 2022
Resolution: USCG witnessed installation and operation of electric fire pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 June 2022
Resolved
Hydro test on boiler shall be conducted IAW 46 CFR 61.05-10 table. Hydro test on boiler to be completed prior to 15 DEC 2022.
46 CFR 61.05-10
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 December 2022
Resolved 10 November 2022
Resolution: USCG Sector Puget Sound attended vessel and witnessed satisfactory hydro test of boiler.
Lifesaving › Inflatable Liferafts › Servicing
Issued 27 April 2018
Resolved
Provide proof of liferaft servicing certificate; properly reinstall 2x100 liferafts after service IAW 46 CFR 180.10-20 (No Sail).
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2018
Engineering › Feedwater/Condensate Water System › Pump
Issued 27 April 2018
Resolved
Properly replace bolt on #2 feedwater pump currently spraying water and properly seal watertight IAW 46 CFR 61.15-5 NLT 08MAY2018.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2018
Resolved 4 May 2018
Engineering › Pressure Vessel › Maximum Allowable Working Pressure
Issued 27 April 2018
Resolved
Properly conduct test of fired water heater IAW 46 CFR 176.25-32 NLT 27MAY2018.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2018
Resolved 28 April 2023
Resolution: The oil fired Way Wolff ships heater has been removed from the vessel and replaced with an electric heating unit.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 27 April 2018
Resolved
Properly place onboard proof of consortium letter IAW 46 CFR 16 NLT 08MAY2018.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2018
Resolved 4 May 2018
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 27 April 2018
Resolved
Properly place onboard drug and alcohol testing kits that are not expired IAW 46 CFR 16.240 & 46 CFR 4.06 (No Sail).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2018
Documentation › Certificates/Documents › Permit, Other
Issued 27 April 2018
Resolved
Recommend [name withheld] renew CPR card IAW with NVIC 1-91.
Condition: Improper/Lack of Maintenance
Due 24 May 2018
Resolved 4 May 2018
Lifesaving › Lifebuoys › Serviceable
Issued 27 April 2018
Resolved
Replace retroflective tape on all ring lifebouys onboard IAW 46 CFR 180.30 NLT 08MAY2018.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2018
Resolved 4 May 2018
Fire Fighting › Fire Hoses › Condition
Issued 27 April 2018
Resolved
Replace fire hose on #1 Fire Station broke at connection IAW 46 CFR 181-15-10 (No Sail).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2018