MAURY USCG vessel records
← All vessels

MANATEE QUEEN

MANATEE QUEEN is a 1994 passenger vessel (inspected). The Coast Guard has recorded 9 inspections since 2016, most recently in May 2026, along with 14 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 6 May 2026.

Built
1994
Last inspected
6 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 6 May 2026
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

417767
Flag
UNITED STATES
Maury page id
psix-417767

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

9 inspections, each with its date, unit and type; 14 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 9

6 May 2026 Administrative Inspection · Drydock Exam · Vessel Attendance · Hull Examination · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8367883
17 November 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8249672
21 November 2024 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8020492
19 October 2023 Administrative Inspection · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7811149
22 April 2021 Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7180924
16 June 2020 Administrative Inspection · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6967217
16 April 2019 Drydock Exam · COI Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6663440
9 March 2018 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6344349
8 November 2016 COI Inspection · Hull Examination · DAPI Audit · Examination of Repairs · Deadweight Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6033150

Deficiency record · 14

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 May 2026 Resolved
A vessel that is exposed to salt water not more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every five years. Vessel was due for drydock examination on 30Apr2026 and has yet to receive a drydock exam. 46CFR176.600(c)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2026
Resolved 11 June 2026
Resolution: Vessel completed satisfactory inspection for drydock credit.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 17 November 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection and operation of all watertight closures in the hull, decks, and bulkheads including through hull fittings and sea valves. MI observed water in the center tri-toon two voids from the front. Operator must complete permanent repairs during the next drydock period. 46CFR 176.802
Action required: 705 - Other - as specified
Due 30 April 2026
Resolved 11 June 2026
Resolution: Repairs to center pontoon hull deemed satisfactory upon completion of credit drydock.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 October 2023 Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessel was due for COI inspection on 25JUL21 and has yet to receive a COI inspection. Vessel shall not operate with passengers until new COI has been issued. 46 CFR 176.100
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 October 2023
Resolved 30 November 2023
Resolution: Vessel's COI renewal inspection conducted 30Nov23. Vessel was found to be structurally fit for intended route and service. Temporary COI was endorsed and issued that date.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 June 2020 Resolved
46 CFR 176.810 (b)(1)(iv) The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. All portable fire extinguishers on board are past annual servicing date. Service all portable fire extinguishers prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2020
Resolution: Owner had all fire extinguishers serviced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 June 2020 Resolved
46 CFR 180.70 (d)(1) Each ring life buoy must be approved in accordance with 46 CFR 160.010 Water light battery beyond expiration date.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2020
Resolution: New battery purchased and installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 June 2020 Resolved
46 CFR 180.70 (d)(3) Each floating water light installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion resistant clip to allow the water light to be quickly disconnected from the ring life buoy. Clip corroded shut and no longer operates as intended.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2020
Resolution: New corrosion resistant clip purchased and installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 April 2019 Resolved
To maintain a valid certificate of inspection, you must complete your annual inspection within the periods specified. The vessel's annual inspection date was January 10, 2019 and was required an inspection no later than April 10, 2019. Vessel is prohibited from carrying passengers until a new certificate of Inspection is issued.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 April 2019
Resolved 25 April 2019
Resolution: Vessel completed satisfactory COI inspection
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 April 2019 Resolved
The owner or managing operator shall make a vessel available for dry-dock examination required by 46CFR176.600. Vessel's dry-dock exam was due december 30, 2018. Vessel is prohibited from carrying passengers until a dry-dock is completed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 April 2019
Resolved 25 April 2019
Resolution: Vessel completed satisfactory dry-dock exam.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 9 March 2018 Resolved
Provide 4 adult and 1 child lifejacket. lifejackets were found to be unserviceable. 46CFR180.71
Action required: 705 - Other - as specified
Due 9 March 2018
Resolved 9 March 2018
Resolution: Lifejackets were replaced on the spot.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 9 March 2018 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 March 2018
Resolved 9 March 2018
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 March 2018 Resolved
Provide Coast Guard approved first aid kit or a kit with equivalent contents. 46CFR184.710
Action required: 705 - Other - as specified
Due 18 March 2018
Resolved 9 March 2018
Resolution: Operator ordered CG approved first aid kit.
Electrical › Electric Supply System (service) › Battery Installation
Issued 8 November 2016 Resolved
Batteries were open and exposed to water spray. 46CFR183.350
Action required: 705 - Other - as specified
Due 8 January 2017
Resolved 27 December 2016
Resolution: Owner installed new box to protect batteries.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 8 November 2016 Resolved
Hand rail course spacing exceded 4 inches. 46CFR177.900
Action required: 705 - Other - as specified
Due 8 January 2017
Resolved 10 January 2017
Resolution: Owner added course rails to reduce spacing to the required 4 inches.
Construction/Loadline › Hull › Bracket
Issued 8 November 2016 Resolved
Cracks and corrosion noted at attachment brackets from pontoons to deck. 46CFR176.600
Action required: 705 - Other - as specified
Due 8 January 2017
Resolved 27 December 2016
Resolution: Owner replace all attachment brackets with new material.

Ownership record