MAURY USCG vessel records Sign in
← All vessels

NOSCO GLORY

NOSCO GLORY is a 1995 freight ship. The Coast Guard has recorded 13 inspections since 1995, most recently in February 2012, along with 9 deficiencies — 2 with no resolution recorded —.

Records from 1995 to 2012. Most recent: inspection, 3 February 2012.

Built
1995
Last inspected
3 February 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9104469 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
417792
Flag
VIETNAM
—
Maury page id
psix-417792

Inspections, by type

…with no type recorded7
…past their stated due date2
Years with a record 10 calendar years (1995–2012)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it36074 - Convention (Subpart B), Gross Ton
23452 - Convention (Subpart B), Net Ton
78380 - Displacement, Ton
68591 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 13

3 February 2012 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4230270
7 August 2008 Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex V Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3291805
24 May 2006 PII Safety Exam · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2654037
24 January 2004 Ballast Water Examination · MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1990711
22 December 2002 MARPOL Annex I Examination · Annual Inspection · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1716690
10 December 2001 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 296194
24 September 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 293813
21 March 1999 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 426474
23 December 1998 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 423961
15 March 1998 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 413540
9 February 1998 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 412663
2 October 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 396133
30 April 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 377952

Deficiency record · 9

Documentation › Logs/Records › Oil Record Book
Issued 3 February 2012 No resolution recorded
1710 - Oil Record Book - The ORB shall be completed on each occasion whenever the following machinery space operations occurs: collection of oil residues. Soundings for the FO Drain Tank and Stuffing Box Drain Tank have not been record in the ORB since 9 AUG 2011 despite being listed in block 3.1 of the supplement to the IOPP. - MARPOL 2006 Cons. ed. I/17
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 February 2012 — due date passed with no resolution recorded
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 3 February 2012 No resolution recorded
0899 - Other (acid Prevent) - Each transfer pipe system must not leak under static liquid pressure test at 1.5 times the MAWP. The frequency of the test must be annually. The vessel cannot provide documentation attesting to the pipe being hydrostatically tested to 1.5 times the MAWP- 33 CFR 156.170
Action required: 703 - Prior to bunkering operations
Due 6 February 2012 — due date passed with no resolution recorded
Operations/Management › EPA Vessel General Permit (VGP) › 1.5.1-VGP Notice of Intent (NOI)
Issued 3 February 2012 Resolved
9900 - other (not clearly hazardous) - The vessel master and senior crew on board could not produce a VGP and did not appear to be aware of the requirements outlined in the VGP. PSCO instructed the master and crew that they must obtain and read the VGP. PSCO provided the master and crew with a copy of the EPA VGP Fact Sheet.- 33 USC 1251
Action required: 705 - Other - as specified
Due 3 February 2012
Resolved 3 February 2012
Resolution: The vessel''''s master was advised of U.S. EPA VGP requirements.
Operations/Management › EPA Vessel General Permit (VGP) › 4.1.1-Routine Visual Inspections
Issued 3 February 2012 Resolved
9900 - other (not clearly hazardous) - Vessel masters/crew must complete visual inspection in accordance with section 4 of the VGP and record all results in the vessel's recordkeeping documentation. The master/crew could not produce documentation that the visual inspections have been conducted or recorded.- 33 USC 1251 & VGP Part 4
Action required: 705 - Other - as specified
Due 3 February 2012
Resolved 3 February 2012
Resolution: The vessel''''s master was advised of U.S. EPA VGP requirements.
Fire Fighting › Remote Fuel Shutoff › General
Issued 24 January 2004 Resolved
Install remote shutoff valve for emergency generator fuel tank outside the emergency generator space to the satisfaction of class prior to next U.S. port after sailing foreign. SOLAS II-2/15.2.5
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 May 2006
Resolution: Inspected, found repaired.
Fire Fighting
Issued 21 March 1999 Resolved
The safety taglines for the firefighting suits were not fire resistant as required by SOLAS regulations.
Condition: Unknown
Due 22 March 1999
Resolved 22 March 1999
Lifesaving
Issued 9 February 1998 Resolved
PROVIDE/INSTALL WEAK LINKS FOR LIFERAFTS.
Condition: Unknown
Due 16 March 1998
Resolved 16 March 1998
Documentation
Issued 9 February 1998 Resolved
ENSURE MANNING OF SHIP MEETS REQUIREMENTS OF MANNING CERTIFICATE.
Condition: Unknown
Due 9 February 1998
Resolved 10 February 1998
Lifesaving
Issued 9 February 1998 Resolved
PROVE PROPER OPERATION OF RELEASING GEAR FOR STARBOARD SIDE LIFEBOAT.
Condition: Unknown
Due 9 February 1998
Resolved 10 February 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.