MAURY USCG vessel records Sign in
← All vessels

MANTA RAIV

MANTA RAIV is a 1993 passenger vessel (inspected). The Coast Guard has recorded 48 inspections since 1994, most recently in July 2026, along with 70 deficiencies and 1 operational control.

Records from 1994 to 2026. Most recent: inspection, 17 July 2026.

Built
1993
Last inspected
17 July 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDN6497
417959
Flag
UNITED STATES
—
Maury page id
psix-417959

Inspections, by type

…with no type recorded9
Years with a record 26 calendar years (1994–2026)
The 48 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it3 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 48

17 July 2026 Administrative Inspection
Administrative · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8440821
30 April 2026 Internal Structural Exam · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8359018
8 October 2025 Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 8253281
6 October 2025 Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 8253726
24 March 2025 Drydock Exam · Annual Inspection · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8099693
4 March 2024 Annual Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7874077
17 June 2023 Examination of Repairs · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7716774
6 May 2023 Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 7691748
2 March 2023 COI Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7637209
8 November 2022 Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7602974
2 December 2021 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7361120
9 November 2021 Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 7359045
3 December 2020 Internal Structural Exam · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7103901
31 January 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6900508
21 January 2020 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6893150
13 December 2019 Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6893162
31 January 2019 Internal Structural Exam · Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6617507
15 December 2017 Administrative Inspection · Drydock Exam · Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6322462
15 March 2017 Administrative Inspection · Hull Examination · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6102867
24 January 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6077098
18 December 2015 COI Inspection · Administrative Inspection · Hull Examination · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5784529
7 March 2014 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4813440
16 November 2010 Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3880354
18 February 2010 Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3681430
3 December 2008 Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3373411
12 July 2007 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2992774
28 March 2007 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2896984
11 January 2007 Deficiency Check · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2953760
25 September 2006 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2792162
29 November 2005 COI Inspection · Hull Examination · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2542622
7 December 2004 Hull Examination · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2255061
3 December 2003 Hull Examination · Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1959144
14 November 2003 Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1950387
18 March 2003 Deficiency Check · Administrative Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1759255
16 December 2002 Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1717772
5 January 2001 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 825406
23 December 1999 Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1378896
19 February 1999 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 798002
7 January 1999 Hull Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1393071
8 January 1998 MARPOL Annex V Examination · COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1436030
3 January 1997 Hull Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1371628
10 October 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 19618
25 July 1996 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1088029
5 March 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 886312
3 January 1996 Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1469452
16 September 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 155561
17 January 1995 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1459149
19 December 1994 COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1353677

Deficiency record · 70

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 March 2025 Resolved
All vessels required to have exhaust blowers for gasoline engines/fuel tanks must have a red warning sign at the starting switch that states that the blowers must be operated prior to starting the engines for the time sufficient to insure at least one (01) change of air in the space served (02 minutes).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2025
Resolved 28 March 2025
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 March 2025 Resolved
Must add two (02) fasteners to clamp located on starboard transom section of vessel (clamp for collar to superstructure of vessel).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2025
Resolved 28 March 2025
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 24 March 2025 Resolved
Must conduct repair on 1/4" hole in vessel transom to satisfaction of USCG Marine Inspector. Corrected
Action required: 10 - Deficiency Rectified
Resolved 24 March 2025
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 March 2025 Resolved
Vessels on limited coastwise routes are required to carry six (06) red and six (06) orange flares or twelve (12) red flares. Vessel had nine (09) red flares at the time of the inspection. Must add three (03) more flares for vessel's route. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 24 March 2025
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 24 March 2025 Resolved
Vessel EPIRBS must be tested monthly and logged. No log entries for EPIRB tests at time of inspection. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 24 March 2025
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 2 December 2021 Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below. The vessel's port mid tube chamber was not holding pressure due to failure of a baffle . The vessel needs to conduct the overpressure "stress" test IAW Sector Honolulu Work Instruction 07 in the presence of an attending Coast Guard Marine Inspector and prior to operating with passengers.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 January 2022
Resolved 15 March 2022
Resolution: Vessel deactivated due to overdue annual and drydock and no progress on deficiency correction.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 December 2021 Resolved
Electrical equipment in spaces containing machinery powered by, or fuel tanks for, gasoline or other fuels having a flashpoint of 43.3 °C (110 °F) or lower must be explosion-proof or ignition-protected, or be part of an intrinsically safe system. Open electrical wirings in same space as gasoline fuel lines and filters.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 January 2022
Resolved 15 March 2022
Resolution: Vessel deactivated due to overdue annual and drydock and no progress on deficiency correction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 December 2021 Resolved
The owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the External inspection of fuel tanks and inspection of tank vents, piping, and pipe fittings. Gasoline fill and tank vent pipings are cracked and tank vent line does not have flame screen.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 January 2022
Resolved 15 March 2022
Resolution: Vessel deactivated due to overdue annual and drydock and no progress on deficiency correction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 December 2021 Resolved
Nozzles, flanges, or other fittings for pipe connections to a metal tank must be welded or brazed to the tank. Fuel suction fitting connections to tank is severely pitted.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 January 2022
Resolved 15 March 2022
Resolution: Vessel deactivated due to overdue annual and drydock and no progress on deficiency correction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 December 2021 Resolved
A mechanical exhaust system consisting of at least two ventilation exhaust ducts located at the end of the space opposite from where the supply ducts are fitted. Ducts were not fully connected to mechanical exhaust system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 January 2022
Resolved 15 March 2022
Resolution: Vessel deactivated due to overdue annual and drydock and no progress on deficiency correction.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 2 December 2021 Resolved
Inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks. Cannot adequately determine the condition of hull under the aluminum gasoline fuel tank due to limited tank bottom and hull spacing.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 January 2022
Resolved 15 March 2022
Resolution: Vessel deactivated due to overdue annual and drydock and no progress on deficiency correction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 December 2021 Resolved
There must be a means of accurately determining the amount of fuel in each fuel tank either by sounding, through a separate sounding pipe or a fill pipe, or by an installed marine type fuel gauge. The fuel level sensor wiring is broken off and not being used.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2022
Resolved 15 March 2022
Resolution: Vessel deactivated due to overdue annual and drydock and no progress on deficiency correction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 December 2021 Resolved
The pump is listed by an independent laboratory as meeti ng the requirements in UL 1113. Submersible bilge pump is not UL 1113.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2022
Resolved 16 March 2022
Resolution: Vessel deactivated due to overdue annual and drydock and no progress on deficiency correction.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 21 January 2020 Resolved
Replace EPIRB Battery
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2020
Resolved 30 January 2020
Resolution: Marine Inspector verified new EPIRB installed on vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 January 2020 Resolved
Exhaust blower switches must be interlocked with starting switch and ignition switch so that the blowers are started before the engine starter motor circuit or the engine ignition is energized.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2020
Resolved 7 February 2020
Resolution: The exhaust blower switches was interlocked with starting switch and ignition switch. The blowers started before the engine ignition energized.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 December 2017 Resolved
Vessel needs to install an all around mast headlight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 December 2018
Resolved 15 December 2017
Resolution: The company installed an all around mast headlight onboard the vessel.
Communications › Alarms/Indicators › Bilge Alarm
Issued 15 December 2017 Resolved
Vessel needs to ensure the visual indicator is operational for its onboard bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2018
Resolved 15 December 2017
Resolution: The vessel installed operable bilge pump visual indicators.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 15 December 2017 Resolved
Vessel needs to replace 04 adult life jackets onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2018
Resolved 15 December 2017
Resolution: The vessel replaced the worn life jackets with new ones.
Lifesaving › Lifebuoys › Serviceable
Issued 15 December 2017 Resolved
The vessel needs to replace its ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2018
Resolved 15 December 2017
Resolution: The company replaced the vessel's ring bouy with a new one.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 March 2017 Resolved
Vessel needs to be equipped with full complement of working navigation lights as required by the vessel’s operation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 20 April 2017
Resolution: Vessel installed red, white, red nav lights for night diving operations.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 15 March 2017 Resolved
Vessel’s name needs to be clearly posted on the vessel.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 20 April 2017
Resolution: Vessel operator installed newly stenciled vessel name in a clearly visible section of the hull.
Documentation › Certificates/Documents › Permit, Other
Issued 15 March 2017 Resolved
Vessel operators need to provide a valid FCC Marine Radio Operator Permit. 47 CFR 176.830
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 15 April 2017
Resolution: Vessel operator provided proof of holding a valid FCC marine radio operator permit.
Construction/Loadline › Structures › Superstructure
Issued 15 March 2017 Resolved
Vessel needs to weld crack forming around the pipe on the portside.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 20 April 2017
Resolution: Vessel operator had a local welder repair the crack forming around the pipe on the portside aft handrail near the ladder.
Construction/Loadline › Hull › Hull Plating
Issued 16 November 2010 Resolved
Starboard aft baffle failed overpressure collar test. Renew failed baffle and conduct satisfactory overpressure test in accordance with Sector Honolulu work instruction #7 prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 December 2010
Resolved 20 December 2010
Engineering › Fuel Oil Service System › Valve
Issued 16 November 2010 Resolved
Renew and prove operation of emergency fuel shut off valve in accordance with 46CFR182.455.
Due 16 December 2010
Resolved 20 December 2010
Communications › Alarms/Indicators › General Alarm
Issued 16 November 2010 Resolved
Prove operation of gasoline vapor detection alarm in accordance with 46CFR182.480
Due 16 December 2010
Resolved 20 December 2010
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 November 2010 Resolved
Provide two portable lights onboard in accordance with 46CFR183.430.
Due 16 December 2010
Resolved 20 December 2010
Documentation › Markings/Placards › Lifejacket Placard
Issued 16 November 2010 Resolved
Renew and post lifejacket donning placard in accordance with 46CFR185.516.
Due 16 December 2010
Resolved 20 December 2010
Stability › Unintentional Flooding › General
Issued 16 November 2010 Resolved
Provide suitable mechanical patch kit for inflatable collars on board in accordance with Sector Honolulu work instruction #7.
Due 16 December 2010
Resolved 20 December 2010
Operations/Management › Equipment Service/Testing › EPIRB
Issued 3 December 2008 Resolved
Replace EPIRB battery. Sticker indicated battery expired on 12/07.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 December 2008
Documentation › Certificates/Documents › FCC SSL
Issued 11 January 2007 Resolved
Obtain new safety radiotelephony certificate
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 February 2007
Resolved 19 January 2007
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 11 January 2007 Resolved
Show proof of a valid marine radio operators permit
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 February 2007
Resolved 19 January 2007
Communications › Radio Communications › EPIRB
Issued 11 January 2007 Resolved
Install new NOAA registration sticker to EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 February 2007
Resolved 19 January 2007
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 11 January 2007 Resolved
Label stowage of child-sized lifejackets
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 February 2007
Resolved 19 January 2007
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 11 January 2007 Resolved
Provide paperwork proof of negative pre-employment test results
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 February 2007
Resolved 19 January 2007
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 29 November 2005 Resolved
Renew retro on seven adult PFD's
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2005
Resolved 2 December 2005
Communications › Radio Communications › EPIRB
Issued 29 November 2005 Resolved
Renew as original antenna on EPIEB
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2005
Resolved 2 December 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 29 November 2005 Resolved
Renew batteries in Float Light
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2005
Resolved 2 December 2005
Lifesaving › Lifefloat › Paddle
Issued 29 November 2005 Resolved
Stow paddles in life float.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2005
Resolved 2 December 2005
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 29 November 2005 Resolved
Prove sensor on vapor detection system as per system manual testing instructions.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2005
Resolved 2 December 2005
Engineering › Gasoline Engine (propulsion) › Spark Plug (2 stroke)
Issued 29 November 2005 Resolved
Prove proper operation of the Port outboard engine.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2005
Resolved 2 December 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 November 2005 Resolved
Update first aid Kit.
Due 10 December 2005
Resolved 2 December 2005
Engineering › Fuel Oil Storage/Transfer System
Issued 3 December 2003 Resolved
Provide proper fuel hoses (SAE J-1942). LEGACY COMPONENT DESC: Hose
Condition: Placed in Improper Service
Due 3 January 2004
Resolved 17 December 2003
Engineering › Fuel Oil Storage/Transfer System
Issued 3 December 2003 Resolved
Provide grounding strap for independent fuel tank. LEGACY COMPONENT DESC: Tank
Condition: Placed in Improper Service
Due 3 January 2004
Resolved 17 December 2003
Engineering › Fuel Oil Storage/Transfer System
Issued 3 December 2003 Resolved
Provide vapor detector IAW 46CFR182.480 prior to carrying passengers. LEGACY COMPONENT DESC: Ventilation
Condition: Placed in Improper Service
Due 3 December 2003
Resolved 17 December 2003
Engineering › Fuel Oil Storage/Transfer System
Issued 3 December 2003 Resolved
Provide switch for exhaust blower that interlocks with ingintion IAW 46CFR182.460(e) prior to carrying passengers. LEGACY COMPONENT DESC: Ventilation
Condition: Placed in Improper Service
Due 3 December 2003
Resolved 17 December 2003
Construction/Loadline › Structures
Issued 3 December 2003 Resolved
Properly repair fractured welds on bimany cover. LEGACY COMPONENT DESC: Superstructure
Condition: Unknown
Due 3 January 2004
Resolved 17 December 2003
Engineering › Fuel Oil Service System
Issued 16 December 2002 Resolved
Prove proper operation of fuel shut off valves IAW 46CFR182.455. LEGACY COMPONENT DESC: Valve
Condition: Unknown
Due 30 December 2002
Resolved 18 March 2003
Electrical › Electrical Distribution System (service)
Issued 16 December 2002 Resolved
Remove or properly dead end wires located at operating station IAW 46CFR183.340. LEGACY COMPONENT DESC: Wiring
Condition: Unknown
Due 30 December 2002
Resolved 18 March 2003
Navigation › Piloting/Steering
Issued 16 December 2002 Resolved
Provide CG light list IAW 46CFR184.420. LEGACY COMPONENT DESC: Coast Guard Light List
Condition: Unknown
Due 30 December 2002
Resolved 18 March 2003
Navigation › Piloting/Steering
Issued 16 December 2002 Resolved
Prove proper operation of compass light. Vessel restricted to day light operations. LEGACY COMPONENT DESC: Magnetic Compass
Condition: Unknown
Due 30 December 2002
Resolved 18 March 2003
Engineering › Bilge Water Management System
Issued 16 December 2002 Resolved
Prove proper operation of visual indicator for automatic bilge pump IAW 46CFR182.520. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Due 30 December 2002
Resolved 18 March 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 16 December 2002 Resolved
Provide 8 adult and 3 child CG approved lifejackets. Vessel is restricted to carrying 14 adults and no children until lifejackets are provided IAW 46CFR180.71. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Due 16 December 2002
Resolved 18 March 2003
Lifesaving › Lifebuoys
Issued 16 December 2002 Resolved
Provide light for lifebuoy IAW COI. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper/Lack of Maintenance
Due 30 December 2002
Resolved 18 March 2003
Lifesaving › Buoyant Apparatus
Issued 16 December 2002 Resolved
Prove proper operatioon of light for BA IAW 46CFR180.175. LEGACY COMPONENT DESC: light
Condition: Improper/Lack of Maintenance
Due 30 December 2002
Resolved 18 March 2003
Communications › Radio Communications › EPIRB
Issued 16 December 2002 Resolved
sticker showing registration renewal was not on the device or availabe during inspection.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 December 2002
Resolved 18 December 2002
Resolution: copy of new registration faxed to CG office
Fire Fighting
Issued 7 January 1999 Resolved
Vent closure device stuck in open position. Prove proper operation of ventclosure to fuel tank space.
Condition: Unknown
Due 1 February 1999
Resolved 1 February 1999
Construction/Loadline
Issued 7 January 1999 Resolved
Relief valve leaked during alternate chamber pressure test. Renew relief valve for starboard aft tube.
Condition: Unknown
Due 7 January 1999
Resolved 7 January 1999
Lifesaving
Issued 7 January 1999 Resolved
Child life jacket strap frayed beyond accepted tolerance. Replace (1) childlife jacket with approved type.
Condition: Unknown
Due 7 January 1999
Resolved 7 January 1999
Accommodation/Occupational Safety
Issued 7 January 1999 Resolved
Handrail found fractured on left side of starboard ladder. Properly repairhandrail fracture on starboard side.
Condition: Unknown
Due 7 January 1999
Resolved 7 January 1999
Lifesaving
Issued 8 January 1998 Resolved
EPIRB NOT MARKED WITH VESSEL NAME.
Condition: Unknown
Due 15 January 1998
Resolved 15 January 1998
Lifesaving
Issued 8 January 1998 Resolved
LIFE RING MISSING RETRO TAPE._x001C_ _x001C_
Condition: Unknown
Due 15 January 1998
Resolved 15 January 1998
Documentation
Issued 3 January 1996 Resolved
Provide evidence of drug awareness training for vessel crew members, minimum sixty minutes for supervisors.
Condition: Unknown
Due 3 January 1996
Resolved 3 January 1996
Documentation
Issued 3 January 1996 Resolved
Incorporate into the company drug testing policy the five elements of drug testing (Random, Pre-employment, Periodic, Marine Incident, and Probable Cause), Medical Review Officer, and Employee Assistance Program to include education and training.
Condition: Unknown
Due 3 January 1996
Resolved 3 January 1996
Lifesaving
Issued 3 January 1996 Resolved
Renew buoyant apparatus water light lanyard with 18ft, U/V resistant, polypropylene lanyard.
Condition: Unknown
Due 3 January 1996
Resolved 3 January 1996
Navigation
Issued 3 January 1996 Resolved
Provide and properly install as per 72COLREGS navigational night dive lights.
Condition: Unknown
Due 3 January 1996
Resolved 3 January 1996
Documentation
Issued 17 January 1995 Resolved
PROVIDE COPY OF FCC SAFETY CERTIFICATE. VESSEL IS RESTRICTED TO A ROUTE NOT MORE THAN 1000 FEET FROM SHORE UNTIL COPY OF CERTIFICATE IS RECEIVED BYMSO HONOLULU.
Condition: Unknown
Due 17 January 1995
Resolved 17 January 1995
Navigation
Issued 19 December 1994 Resolved
PROVIDE COPIES OF ALL REQUIRED PUBLICATIONS NECESSARY FOR SAFE VESSEL OPERATION.
Condition: Unknown
Due 19 December 1994
Resolved 19 December 1994
Navigation
Issued 19 December 1994 Resolved
VESSEL IS RESTRICTED TO DAYTIME OPERATION ONLY UNTIL PLANS FOR NAVIGATION LIGHTS ARE APPROVED.
Condition: Unknown
Due 19 December 1994
Resolved 19 December 1994
Navigation
Issued 19 December 1994 Resolved
PROVE VESSEL IS FULLY OUTFITTED AND OPERATIONAL TO THE MARINE INSPECTOR IN AREA OF OPERATION.
Condition: Unknown
Due 19 December 1994
Resolved 19 December 1994

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.