Records from 1984 to 1999. Most recent: inspection, 11 February 1999.
Documentation record
Registered dimensions (L × B × D)252.0 ft × 40.1 ft × 12.8 ft
Registered tonnagegross 1,235 / net 744
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · CHESTER, PA, UNITED STATES · built 1924
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationNo Operation - PM · issued 5 May 1983 · expires 31 May 1996
Service, as the file records itTank Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1235 - Regulatory (Subpart C or D), Gross Ton
744 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 32
11 February 1999
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 729951
7 November 1998
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 211001
8 February 1994
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1164392
10 March 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 946991
28 March 1991
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 477264
26 September 1990
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 495865
22 August 1990
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1228317
3 August 1990
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 928096
3 May 1990
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 336950
28 March 1990
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 491587
18 March 1990
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1212447
7 December 1989
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 902440
28 November 1989
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 922061
9 November 1989
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 913115
6 October 1989
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 436568
6 October 1989
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1213085
3 October 1989
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1001941
25 September 1989
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1342484
8 February 1989
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 328449
19 December 1988
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 524666
8 September 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1349935
5 August 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1035484
3 June 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 890122
13 February 1988
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 446321
28 September 1987
Examination of Repairs
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1012958
28 September 1987
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1316559
8 May 1987
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1030315
8 May 1987
MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1337773
6 May 1986
Credit Drydock · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1299205
25 March 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 979856
11 March 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1285803
12 December 1984
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 531007
Navigation
Issued 3 August 1990
Resolved
PROPERLY REPAIR WASTED PORT NAVIGATION LIGHT SHIELD.
Condition: Unknown
Due 3 August 1990
Resolved 3 August 1990
Lifesaving
Issued 3 August 1990
Resolved
PROPERLY INSTALL SUFFICIENT PRIMARY LIFESAVING EQUIPMENT IAW 46 CFR 33.05-1(A)(F) NO LATER THAN 20 AUG 90. VESSEL IS LIMITED LAKES, BAYS, ABD SOUNDS ROUTE UNTIL COMPLETED.
Condition: Unknown
Due 3 August 1990
Resolved 3 August 1990
Lifesaving
Issued 3 August 1990
Resolved
REPLACE LIFEBOAT DAVIT BLOCKS WITH ACCEPTABLE BLOCKS. WOOD IS ROTTEN. (TO BE COMPLETED NO LATER THAN 08 SEP 90).
Condition: Unknown
Due 3 August 1990
Resolved 3 August 1990
Deck/Cargo
Issued 3 August 1990
Resolved
DEMONSTRATE PROPER OPERATION OF PRESSURE VESSEL RELIEF VALVES.
Condition: Unknown
Due 3 August 1990
Resolved 3 August 1990
Construction/Loadline
Issued 18 March 1990
Resolved
PRIOR TO DISCHARGING OR LOADING CARGO, THE HULL MUST BE INSPECTED BY A DIVER FOR DAMAGE AND A REPORT MADE TO THE COAST GUARD MARINE INSPECTION OFFICE, NY,NY.
Condition: Unknown
Due 18 March 1990
Resolved 18 March 1990
Navigation
Issued 3 October 1989
Resolved
PROVE PROPER OPERATION OF ELECTRONIC DEEP SEA SOUNDING APPARATUS (FATHOMETER). VESSEL IS RESTRICTED TO LAKES, BAYS AND SOUNDS ROUTE UNTIL FATHOMETER IS PROVEN OPERABLE.
Condition: Unknown
Due 3 October 1989
Resolved 3 October 1989
Engineering
Issued 3 October 1989
Resolved
PROVE PROPER OPERATION OF AUTOMATION SYSTEM UNTIL AUTOMATION IS PROVER RELIABLE, ADDITIONAL MANNING IS REQUIRED AS FOLLOWS: COASTWISE ; (1) 1ST ASSISTANT ENG, (1) 2ND ASSITANT ENG. LAKES BAYS AND SOUNDS; (1) 1ST ASSISTANT ENG.
Condition: Unknown
Due 3 October 1989
Resolved 3 October 1989
Lifesaving
Issued 5 August 1988
Resolved
CONDUCT SATISFACTORY LIFEBOAT AND FIRE DRILL IN PRESENCE OF COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 5 August 1988
Resolved 5 August 1988
Construction/Loadline
Issued 5 August 1988
Resolved
MAKE PERMANENT REPAIRS TO AFT WALL OF BALLAST TANK EXPANSION TRUNK. REPLACETEMPORARILY BOLTED STEEL PLATES WITH WELDED INSERTS. THIS SHALL BE COMPLETED DURING THE NEXT DRYDOCKING.
Condition: Unknown
Due 5 August 1988
Resolved 5 August 1988
Construction/Loadline
Issued 28 September 1987
Resolved
GAS-FREE AND MAKE PERMANENT REPAIR TO HOLES IN WAY ON NO.2 AND NO.3 STARBOARD CARGO TANKS. NO CARGO MAY BE CARRIED IN THESE TANKS UNTIL PERMANENT REPAIR IS MADE.
Condition: Unknown
Due 28 September 1987
Resolved 28 September 1987
Fire Fighting
Issued 11 March 1985
Resolved
CONDUCT ANNUAL SERVICING FOR FIRE PROTECTION EQUIPMENT.
Condition: Unknown
Due 11 March 1985
Resolved 11 March 1985