Records from 1995 to 2019. Most recent: inspection, 10 June 2019.
Inspection history · 54
10 June 2019
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6709594
5 June 2019
ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6704211
24 July 2018
Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6482462
3 April 2017
COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6116417
4 October 2016
Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6010960
27 March 2016
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5841376
26 March 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5841086
11 March 2016
Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5831266
10 December 2015
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5779454
23 July 2015
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5193771
10 March 2014
ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4813369
8 July 2012
Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4371749
6 July 2012
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4374601
19 February 2012
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4272143
11 February 2012
Ballast Water Examination · ISPS II Exam · COC-CHEM Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4242611
7 September 2010
Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3843910
4 March 2009
ISPS II Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · COC-CHEM Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3427482
5 May 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3199444
29 June 2007
ISPS II Exam · COC-CHEM Renew · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2977908
1 August 2005
Random ISPS/MTSA/PSC · Ballast Water Examination · COC-CHEM Renew · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2447306
6 August 2004
ISPS II Exam · COC-CHEM Renew
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2158055
9 January 2004
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1985458
27 May 2003
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1802878
3 October 2002
Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1684285
25 March 2002
In-Service Inspection · Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1600774
14 February 2002
Security Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1487347
14 February 2002
Type not recorded
No type recorded · USCGC ASSATEAGUE (WPB 1337) · USCG Oceania District (CGD-O) · Activity 1496421
31 May 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 290598
31 May 2001
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1066256
24 August 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 111016
19 June 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 279071
14 June 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 278965
10 June 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 278777
14 April 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 427260
14 April 1999
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1123970
27 September 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 116712
6 May 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 415605
6 May 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1451297
29 September 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 540712
8 May 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 403367
29 April 1997
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 402960
29 April 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1096539
15 August 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 394525
13 August 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 765892
12 August 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 191844
7 April 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 389765
7 April 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1078674
18 November 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 99858
18 November 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 385251
13 November 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 384902
12 November 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 384868
30 June 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 380233
17 February 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 375372
17 February 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 850046
Electrical › Lighting (service) › Lighting Fixture
Issued 10 December 2015
Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect including those on board tankers or in compartments assigned principally to accumulator batteries or similar spaces, unless the Admin is satisfied that such equipment is of a type which will not ignite the mixture concerned. The bridge battery space contained non-explosion proof lighting.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 9 January 2016
Resolved 23 December 2015
Resolution: Vessel provided documentation attesting to proper installation of explosion proof lighting.
Navigation › Voyage Data Recorder › Voyage Data Recorder (VDR)
Issued 8 July 2012
Resolved
74 SOLAS (09 cons) V/20.1
To aid in casualty investigations, ships, when on international voyages, shall be fitted with a voyage data recorder. Vessel's Voyage Data Recorder was inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2012
Resolution: Vessel sent in tech report attesting to satisfactory condition of VDR.
Deck/Cargo
Issued 29 April 1997
Resolved
PRIOR TO NEXT US VOYAGE, REPAIR PRESSURE GAUGE FOR PUMP (C6) IN CARGO CONTROL PUMP ROOM (NOT OPERATIONAL).
Condition: Unknown
Due 9 May 1997
Resolved 9 May 1997
Engineering
Issued 7 April 1996
Resolved
PROVIDE CLASS SOCIETY REPORT TO [name withheld] REPAIRS TO MINOR LEAK IN WAY OF WELD ON MAIN LUBE OIL PIPE FOR MAIN ENGINE LOCATED OUTBOARD OF THE #1 LUBE OIL PUMP.
Condition: Unknown
Due 20 August 1996
Resolved 20 August 1996
Deck/Cargo
Issued 7 April 1996
Resolved
PRIOR TO UTILIZING THE IGS SYSTEM, PROVIDE CALIBRATION GAS FOR THE OXYGEN ANALYZER.
Condition: Unknown
Due 20 August 1996
Resolved 20 August 1996
Documentation
Issued 17 February 1995
Resolved
PRIOR TO NEXT U.S. VOYAGE, AMEND VESSEL'S OIL TRANSFER PROCEDURES TO ADDRESS VAPOR COLLECTION OPERATIONS TO THE SATISFACTION OF THE FLAG ADMINISTRATION. (REF: 46CFR39.30-1(B)(3))
Condition: Unknown
Due 3 July 1995
Resolved 3 July 1995
Deck/Cargo
Issued 17 February 1995
Resolved
PRIOR TO NEXT U.S. VOYAGE, ADJUST VAPOR CONNECTION FLANGES SUCH THAT THE STUD IS LOCATED AT THE TOP OF THE FLANGE, MIDWAY BETWEEN BOLT HOLES IAW 46CFR39.20-1(E)._x001C_
Condition: Unknown
Due 3 July 1995
Resolved 3 July 1995
Documentation
Issued 17 February 1995
Resolved
PRIOR TO NEXT U.S. VOYAGE, PROVIDE DOCUMENTATION ATTESTING TO THE CONDITIONAND SUITABILITY OF VESSEL'S FIREFIGHTING FOAM AND BREATHING APPARATUS AS REQUIRED BY OR REFERENCED IN IBC CODE 11.3.2 AND 14.2.6 RESPECTIVELY._x001C_
Condition: Unknown
Due 3 July 1995
Resolved 3 July 1995
Documentation
Issued 17 February 1995
Resolved
PRIOR TO NEXT U.S. VOYAGE, AMEND VESSEL'S INERT GAS SYSTEM INSTRUCTION MANUAL (FOR OPERATION AND MAINTENANCE) TO INCLUDE PROCEDURES RELATING TO VAPOR COLLECTION OPERATIONS TO THE SATISFACTION OF THE FLAG ADMINISTRATION.(REF: 46CFR32.53-85(B))._x001C_
Condition: Unknown
Due 3 July 1995
Resolved 3 July 1995
Deck/Cargo
Issued 17 February 1995
Resolved
PRIOR TO NEXT U.S. VOYAGE, PROVE VAPOR COLLECTION SYSTEM'S FLANGED FITTINGSAND SPOOL PIECES ARE ELECTRICALLY CONTINUOUS/BONDED TO THE HULL TO THE SATISFACTION OF THE FLAG ADMINISTRATION. (46CFR39.20-1(A)(5))
Condition: Unknown
Due 3 July 1995
Resolved 3 July 1995
Fire Fighting
Issued 17 February 1995
Resolved
PRIOR TO NEXT U.S. VOYAGE, REPAIR/REPLACE DAMAGED FORWARD DECK FIREFIGHTINGFOAM STATION TO THE SATISFACTION OF THE FLAG ADMINISTRATION.
Condition: Unknown
Due 3 July 1995
Resolved 3 July 1995