Records from 1995 to 2003. Most recent: inspection, 13 January 2003.
Inspection history · 23
13 January 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1729445
7 December 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1729380
21 August 2002
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1670853
15 May 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1616903
27 January 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1481634
22 August 2001
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1373589
29 July 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1070067
23 August 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1369812
1 August 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 820832
25 August 1999
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1459538
14 July 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1096292
28 September 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 800682
26 August 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461906
6 March 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1120609
13 October 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1109673
17 September 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 21983
25 August 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1427396
11 August 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 173169
27 March 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1094029
23 October 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1161317
29 August 1996
Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1427251
29 February 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 885759
5 September 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1355584
Fire Fighting
Issued 25 August 1999
Resolved
PROVIDE INFORMATION ON PORTABLE FIRE EXTINGUISHER WHETHER THEY ARE USCG APPROVED OF FLAG ADMINISTRATION APPROVED.
Condition: Unknown
Due 25 August 1999
Resolved 25 August 1999
Unknown
Issued 25 August 1999
Resolved
COMPLETE DET NORSKE VERITAS OUTSTANDING SURVEY REQUIREMENTS TO THE SATISFACTION OF ATTENDING SURVEYOR.
Condition: Unknown
Due 25 August 1999
Resolved 25 August 1999
Lifesaving
Issued 29 August 1996
Resolved
A. repaint international orange. B. restencil all Solas required hull markings. C. renew all reflective tape with Solas approved type. D. makerepairs to minor fiberglass/gelcoat damages. E. renew hatch gaskets as needed.
Condition: Unknown
Due 29 August 1996
Resolved 29 August 1996
Lifesaving
Issued 29 August 1996
Resolved
Recharge the reserve breathing air cylinder (one of four cylinders) on eachlifeboat that is either low or completely discharged. Find source of leak and make approved repairs.
Condition: Unknown
Due 29 August 1996
Resolved 29 August 1996
Electrical
Issued 5 September 1995
Resolved
Repair/replace the fuel pressure guage on #2 generator engine and the waterguage on the #3 generator engine.
Condition: Unknown
Due 18 December 1995
Resolved 18 December 1995
Fire Fighting
Issued 5 September 1995
Resolved
Repair/replace fire hose stations #15 (blocked), #16 (hose), #31 (hose), #34 (hose), #30 (hose), #70 (hose), #27 (hose), #38 (hose). Items to be completed prior to conducting drilling operations.
Condition: Unknown
Due 7 September 1995
Resolved 18 December 1995
Fire Fighting
Issued 5 September 1995
Resolved
Repair leak to #3 fire pump seal located in port forward pump room.
Condition: Unknown
Due 18 December 1995
Resolved 18 December 1995
Lifesaving
Issued 5 September 1995
Resolved
Repair in-operative rescue boat.
Condition: Unknown
Due 18 December 1995
Resolved 18 December 1995
Fire Fighting
Issued 5 September 1995
Resolved
Repair/replace 150 lb. dry chemical wheeled fire extingusher.
Condition: Unknown
Due 18 December 1995
Resolved 18 December 1995
Fire Fighting
Issued 5 September 1995
Resolved
Replace Co2 fire extingusher cardox loops on helocopter deck as required byfire servicing report dated 30 AUG 95.
Condition: Unknown
Due 18 December 1995
Resolved 18 December 1995
Lifesaving
Issued 5 September 1995
Resolved
Provide documentation of life raft annual servicing.
Condition: Unknown
Due 18 December 1995
Resolved 18 December 1995
Electrical
Issued 5 September 1995
Resolved
Preform operational tests of trips and alarms on #2 generator.
Condition: Unknown
Due 18 December 1995
Resolved 18 December 1995