Records in 2016. Most recent: inspection, 10 August 2016.
Electrical › Electric Supply System (service) › Cable
Issued 18 June 2016
Resolved
Wiring shall be supported in such a manner to avoid chafing or other injury. An electrical outlet box was found secured to a wooden backing plate which is secured to conduits with a plastic tie. 74SOLAS (UNAMEND) II-1/27(a) (VI)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 July 2016
Resolved 10 August 2016
Resolution: The electric box has been removed permanently including its wirings.
Engineering › Lubricating Oil Service System › Piping
Issued 18 June 2016
Resolved
After any survey of the ship has been completed, no change shall be made in the structural arrangement, machinery, equipment, etc. covered by the survey, without the sanction of the administration. A lube oil pipe above the air compressor was found to have a missing cap inside the compressor room. 74SOLAS (UNAMEND) I/11
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 July 2016
Resolved 10 August 2016
Resolution: Cap has been provided on the end of the lube oil pipe.
Electrical › Electric Supply System (service) › Cable
Issued 18 June 2016
Resolved
Wiring shall be supported in such a manner as to avoid chafing or other injury. In the following spaces, exposed wiring and dead end wires were discovered; escape hatch in emergency generator room and steering room. 74SOLAS (UNAMEND) II-1/27(a) (VI)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 July 2016
Resolved 10 August 2016
Resolution: Loose wirings on escape hatch were properly arranged and supported.
Electrical › Lighting (service) › Lighting Fixture
Issued 18 June 2016
Resolved
Lighting fixtures shall be arranged to prevent temperature rises that would be injurious to the wiring, and to prevent the surrounding material from becoming excessively hot. A light fixture in the aft bilge space was found held to the bottom of a deck plate with plastic strap ties and cover secured with multiple strap ties. 74SOLAS (UNAMEND) II-1/27(v)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 July 2016
Resolved 10 August 2016
Resolution: The emergency light in the bilge space has been repaired by replacing the broken cover and was permanently secured.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 18 June 2016
Resolved
Each discharge operation shall be recorded in the Garbage Record Book. Ship did not record discharge operations to a reception facility on 19FEB2016. MARPOL (2011 CONS) Annex V/9(3) (a)
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 June 2016
Resolved 18 June 2016
Documentation › Logs/Records › Garbage Recordkeeping
Issued 18 June 2016
Resolved
Every ship of 400GT and above shall carry a Garbage Management Plan in accordance with the guidelines developed by the Organization. Vessel's Garbage Record Book required the vessel to obtain receipts from reception facilities. MARPOL (2011 CONS) Annex V/9(2)
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 June 2016
Resolved 18 June 2016
Documentation › Logs/Records › Ballast Water Reporting Form
Issued 18 June 2016
Resolved
The master, owner, operator, agent, or person in charge of a vessel must provide the information required by 151.1070 in electronic or written form to the Nation Ballast Information Clearinghouse within 24 hours of arrival. Vessel did not report any ballast operations to NBIC.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 June 2016
Resolved 18 June 2016