Records from 2013 to 2026. Most recent: inspection, 16 April 2026.
Inspection history · 15
16 April 2026
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8350282
24 June 2025
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8166951
29 January 2025
Deficiency Check · DAPI Audit · Inclining Experiment · Administrative Inspection · In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8079314
10 July 2020
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7368754
24 June 2020
Examination of Repairs · COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6992333
6 June 2019
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6705666
29 November 2018
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6589321
15 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6512557
4 December 2017
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6317470
17 June 2017
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6180142
10 April 2017
Annual Inspection · Deficiency Check · Administrative Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6119823
5 January 2017
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6068733
3 November 2016
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6037268
13 January 2016
Deficiency Check · Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5797516
5 January 2016
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5790967
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 16 April 2026
Resolved
Provide an updated copy of the U.S. Coast Pilot [name withheld] List, and Tide Tables.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2026
Resolved 1 May 2026
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 April 2026
Resolved
Provide documentation of rigging inspections completed in accordance with the vessel's Rigging Preventative Maintenance Plan.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2026
Resolved 1 May 2026
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 16 April 2026
Resolved
Provide documentation of the most recent abandon ship drill/training and fire fighting drill/training.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2026
Resolved 1 May 2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 April 2026
Resolved
Remove extension cords or use in accordance with NFPA NEC 2002 (IEEE approved, 18 AWG minimum, lights and fans are okay, no appliances, no multiple cords).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2026
Resolved 1 May 2026
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 April 2026
Resolved
If used, a waste receptacle must be constructed of non-combustible material.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2026
Resolved 1 May 2026
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 April 2026
Resolved
Install a cotter pin or mousing wire on the nut securing the main boom throat pin.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2026
Resolved 1 May 2026
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 June 2019
Resolved
Vessel must have valid state registration to operate commercially in state waters. Register vessel with state of Florida prior to operation in Florida State waters.
Action required: 705 - Other - as specified
Resolved 15 July 2019
Resolution: vessel registration not required for vessels current location of operation. Vessel will have FL state registraion before operating in FL state waters.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 June 2019
Resolved
Vessel must post all pages of stability letter.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 June 2019
Resolved
Mark ring buoy with vessel name with legible block capital letters.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 June 2019
Resolution: labled
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 June 2019
Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 June 2019
Resolved
A vessel must carry either a first-aid kit approved under approval series 46 CFR 160.041 or a kit with equivalent contents and instructions. Vessel did not have adequate aspirin.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2019
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 6 June 2019
Resolved
EPRIB must installed to automatically float free and activate. Battery any Hydrostatic are expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 June 2019
Resolution: all new epirb and battery installed
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 6 June 2019
Resolved
Vessel must have paper versions of all required publications and charts.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 June 2019
Resolved
Demonstrate proper operation of overboard discharge valve forward of collision bulkhead on port side. Valve handle broke off.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 July 2019
Resolution: new handle installed
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 June 2019
Resolved
5 amp breaker for VHF Radio, continually trips with no load. replace fuse.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 June 2019
Resolved
Fuses must all be of the cartridge type only and be UL listed. Fuses in galley are not in compliance.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 July 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 June 2019
Resolved
The AC outlet across from refrigerator space needs a cover as well as the conduit box in the galley space.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 June 2019
Resolved
Repair/replace power supply from the battery switch to the panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 June 2019
Resolution: replaced cable
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 June 2019
Resolved
Remove corrosion off all over-current devices or replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2019
Resolution: replaced
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 November 2018
Resolved
Conduct/complete hull examination (drydock), drydock due date listed on current COI is November 30th, 2018. Last credit drydock was completed on November 3rd, 2016. Vessel is restricted from carrying over 6 passengers after November 30th, 2018 until drydock is completed/credited.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 June 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 15 August 2018
Resolved
Vsl is broadcasting NAME with Vsl type precursor (NAME must not include Vsl type precursors, e.g. F/V, M/V),greater than expected LOA.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2018
Resolved 28 June 2019
Engineering › Bilge Water Management System › Pump
Issued 4 December 2017
Resolved
Provide portable bilge pump
Action required: 705 - Other - as specified
Due 11 December 2017
Resolved 6 December 2017
Resolution: Provided new portable bilge pump.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 4 December 2017
Resolved
Provide valid FCC Safety Certificate
Action required: 705 - Other - as specified
Due 11 December 2017
Resolved 6 December 2017
Resolution: Provided valid certificate.
Sail Rigging › Stays/Shrouds › Wires
Issued 26 April 2017
Resolved
Required owner to provide sufficient rigging inspection program and rigging maintenance schedule.
Action required: 705 - Other - as specified
Due 2 May 2017
Resolved 1 May 2017
Resolution: Owner provided satisfactory rigging inspection program
Engineering › Fuel Oil Service System › Piping
Issued 10 April 2017
Resolved
Renew or repair port fuel tank return fitting to ensure a leak free operation. Vessel is restricted to use of STBD fuel tank until leak is corrected.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 9 May 2017
Resolution: Vessel owner provided pictures of repair to leak in fuel system piping.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 10 April 2017
Resolved
Provide FCC Radio Operator Permit, FF Stations License, and MSC Approved sail plan.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 13 April 2017
Resolution: FCC stations license and operator license provide, sail plan provided to owner by USCG.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 January 2017
Resolved
Make permanent repairs to rails to meet 4" course of netting requirement.
Action required: 705 - Other - as specified
Due 9 February 2017
Resolved 27 March 2017
Resolution: Installed rope courses
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 January 2016
Resolved
Remove extension cord in berthing space.
Action required: 705 - Other - as specified
Due 20 January 2016
Resolved 21 January 2016
Resolution: Vessel removed extension cord in berthing space.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 13 January 2016
Resolved
Provide alcohol test strips.
Action required: 705 - Other - as specified
Due 20 January 2016
Resolved 21 January 2016
Resolution: Vessel provided approved alcohol test strips.