Inspection history · 30
4 October 2024
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8014370
27 May 2022
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7444396
8 November 2021
Administrative Inspection · In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7347332
22 October 2021
Construction Oversight · Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7344819
2 September 2021
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7302698
31 August 2021
COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7300205
24 August 2021
Administrative Inspection · Appeal
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7319427
21 July 2021
Administrative Inspection · In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7274321
7 July 2021
Deficiency Check · In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7248611
15 April 2021
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7176091
2 September 2020
Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7036188
22 April 2020
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6942776
28 February 2020
In-Service Inspection · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6946771
12 September 2019
COI Inspection · In-Service Inspection · MTSA/ISPS Verification · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6804322
22 April 2019
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6668744
10 September 2018
MTSA/ISPS Verification · COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6536706
10 September 2018
Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6536892
23 August 2018
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6520773
10 April 2018
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6388086
4 December 2017
In-Service Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6317645
7 September 2017
Deficiency Check · COI Inspection · MTSA/ISPS Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6260729
21 August 2017
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6247415
8 August 2017
Administrative Inspection
Administrative · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6240316
26 May 2017
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6155900
4 November 2016
Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6035535
2 November 2016
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6038343
12 September 2016
COI Inspection · Deficiency Check · MTSA/ISPS Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5998428
31 May 2016
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5894754
9 May 2016
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5872213
29 January 2016
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5806129
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 31 August 2021
Resolved
Penetrations and openings in watertight bulkheads must be made watertight. Wires/cables were found passing through the watertight bulkhead between the engine room and salon which were not watertight.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2021
Resolved 10 September 2021
Resolution: Vessel applied fire stop putty to openings. District 1 representative was on board and confirmed application, all sat.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 31 August 2021
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the serious marine incident. The alcohol testing strips on board were expired. Cite: 46 CFR 4.06-15(a)(1)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2021
Resolved 4 October 2021
Resolution: Vessel has new test swabs on board
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 31 August 2021
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. The safety radio certificate was expired. Cite: 47 CFR 80.903
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2021
Resolved 10 September 2021
Resolution: Vessel submitted photo of new radio certificate.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 31 August 2021
Resolved
At each initial and subsequent inspection for certification, the marine inspector shall view the vessel afloat and shall conduct the inspections of the hull structure. During the COI inspection, the marine inspector observed an active leak IWO of the horn timber in the main salon. Vessel must address leak prior to leaving the Boston OCMI zone, to the satisfaction of the attending marine inspector.
Cite: 46 CFR 176.25-5 (a)
*Updated due date until next dry dock credit/31MAY22*
Action required: 705 - Other - as specified
Due 31 May 2022
Resolved 13 November 2021
Resolution: Vessel went to drydock and addressed leak in the horn timber. Verified during sea trial that the leak had been fixed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 July 2021
Resolved
The minimum number of mariners holding a MMC officer endorsement as mate, that are required to be carried on every inspected, seagoing, passenger vessel must not be less than the following: Vessels of less than 100 GRT—one mate. The vessel was preparing to get underway for a 10 day voyage with only 1 credentialed mariner on-board. Vessel must not be underway (including anchor) for more than 12 hours in any 24 hour period until a licensed mate is aboard. Due to passengers having access to the vessel during the periods when the vessel is moored, the Captain shall designate, in writing, a senior deckhand to be in charge of the vessel while the credentialed master is resting. The senior deckhand must meet the requirements set forth in NVIC 01-91, "Recommended Qualifications for Small Passenger Vessel Deckhands". Vessel in not authorized to transit outside of Boston's OCMI zone until a licensed mate is onboard.
Action required: 705 - Other - as specified
Resolved 9 July 2021
Resolution: A second credentialed mate arrived onboard the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 July 2020
Resolved
CABLES ENTERING BOXES OR FITTINGS SHALL BE PROTECTED FROM ABRASION AND SHALL CONFORM WITH THE FOLLOWING REQUIRMENTS. OPENINGS THROUGH WHICH CONDOCTORS ENTER SHALL BE ADEQUATLY CLOSED AND THE CABLE ARMOR SHALL BE SECURED TO THE BOX OR FITTING.
NEWLY INSTALLED GENERATOR CABLING IS NOT PROPERLY SUPPORTED AND ELECTRICAL BOXES PENETRATIONS ARE NOT ADEQUATLY CLOSED IN THE FOLLOWING LISTED LOCATIONS.
1. BOTTOM SIDE OF MAIN GENERATOR BREAKER
2. CABLE FEEDS INTO GENERATOR HEADS
3. CABLE FEED FROM MAIN BREAKER TO RANGE SWITCH
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2020
Resolution: Vessel installed proper cabling supports.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 June 2020
Resolved
If individual wires, rather than cable, are used in systems greater than 50 volts, the wire must be in
conduit. Power wires from both generators to their
main breakers are individual conductors. Place
existing wires inside of properly sized conduit or
replace existing wires with properly sized/rated cable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2020
Resolution: Vessel installed properly sized cable for genset
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 June 2020
Resolved
The generator circuit breakers must be interlocked to
prevent the generators from being simultaneously
connected to the switchboard, except for the circuit
breakers of a generator operated in parallel with
another generator when the installation meets
§§111.12-11(f) and 111.30-25(d) in subchapter J of this
chapter. Current dual generator system is not
designed for parallel operation and lacks the required
circuit breaker interlock. Install a interlock system that
prevents both generators from being placed online
simultaneously.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2020
Resolution: Vessel installed interlock for generators.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 10 June 2020
Resolved
Each watertight bulkhead must be of sufficient
strength to be capable of remaining watertight with a
head of water to the top of the bulkhead. Water
ingress observed in the foc'sle space at the forward
watertight bulkhead stbd side. Exact location of
observed leak marked; however, point of ingress has
yet to be determined. Determine cause and location of
water ingress and submit report to attending marine
inspector with plan to repair.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 July 2020
Resolution: Received objective evidence from the vessel master that the bulkhead was not leaking after a temp repair was made with cement.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 19 May 2020
Resolved
Repairs or alterations to the hull,
machinery, or equipment that affect
the safety of the vessel must not be
made without the approval of the cognizant
OCMI. Vessel is replacing both ship service
generators with installations that are not in-kind.
Operator must submit plans for for approval to the
Marine Safety Center.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2020
Resolved 9 November 2020
Resolution: Verified installation iaw regulations. Electrical plans were deemed not necessary for install as all electrical was done in kind. Only weight caluculations were needed. Weight calucations were submitted and deemed satisfatory.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 September 2019
Resolved
Adequate emergency lighting automatically actuated upon failure of the main lighting system shall be fitted along the line of escape in vessel's having lounge areas below the main deck as per §177.30-7 of this subchapter. No emergency lighting installed to show path to emergency escape in forward accommodation space and fish hold accommodations
space. Provide required emergency lighting.
705: No Overnight passengers
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 September 2019
Resolved 20 September 2019
Resolution: Emergency light fixtures added to emergency escape routes in fish hold accommodations and fwd accommodations spaces.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 September 2019
Resolved
Electrical installations and equipment should be installed in a manner that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment, and reasonably safe from electrical shock
of personnel. At numerous locations throughout the vessel's accommodation spaces there are exposed direct current terminal strips and improperly maintained lighting fixtures that present potential shock and fire hazards.
Many of these terminal strips and fixtures are located inside of bunk areas. Enclose or protect terminal strips throughout the vessel and make repairs to all damaged fixtures throughout the vessel to prevent electrical shock.
705: No overnight passengers
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 September 2019
Resolved 20 September 2019
Resolution: Plastic covers installed over all exposed terminals.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 September 2019
Resolved
Each overnight accommodation space on a vessel with overnight
accommodations for passengers must be fitted with an independent modular smoke detector meeting requirements of 181.450. No UL217 smoke detectors installed onboard vessel. Install UL217 smoke detectors as required.
705: No overnight passengers
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 September 2019
Resolved 20 September 2019
Resolution: UL217 smoke detectors installed throughout accommodation spaces.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 September 2019
Resolved
Cables entering boxes or fittings shall be protected from abrasion, and shall be secured to the box or fitting. Starboard aft cable on main generator distribution switch in the engine room is not adequately secured to the box with a fitting. Secure cable entry into box with a fitting designed for enclosure type.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2019
Resolved 20 September 2019
Resolution: Proper cable fitting installed and secured to electrical enclosure.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 September 2019
Resolved
All escape hatches and other emergency exits shall be marked on both sides using at least 1-inch letters: "Emergency Exit, Keep Clear" Emergency escape hatch from the engine room to the galley is not clearly marked. Clearly mark emergency escape hatch from the engine room as required.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2019
Resolved 20 September 2019
Resolution: Emergency escape hatch properly marked.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 September 2019
Resolved
Flexible or portable cables cannot be used for permanently installed wiring. Numerous portable extension cords with deteriorated jacketing and numerous power strips found in use throughout all accommodation spaces. Remove all extension cords and power strips being used.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2019
Resolved 20 September 2019
Resolution: All portable cords and power strips removed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 September 2019
Resolved
Except as otherwise provided in this section, all vessels shall be provided with not less than two avenues of escape from all general areas accessible to the passengers or where the crew may be quartered or normally employed, so located that if one is not available the other may be. Fwd
emergency escape from fwd accommodations space had gear blocking the usage of the hatch. Clear pathway to allow for usage.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 September 2019
Resolved 20 September 2019
Resolution: Crew cleared escape route upon identification.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 12 September 2019
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Fire pump rotating motor coupling is not covered and creates a hazard while the fire pump is operating. Provide a suitable guard or cover to prevent contact with rotating
parts.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2019
Resolved 20 September 2019
Resolution: Guard installed for fire pump coupling.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 12 September 2019
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radio beacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR
part 80. Vessels route requires a operational MF/HF single side band radio. Could not verify operation of Installed MF/HF single side band radio. Provide operational radio as required.
705: Vessel route restricted to no more than 20NM from land
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 26 September 2019
Resolved 20 September 2019
Resolution: Witnessed successful radio HF/MF test with USCGC Escanaba.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 12 September 2019
Resolved
Each garbage management plan under paragraph (a) of this section must be in writing and designate the person who is in charge of carrying out the plan. No person designated to carry out the plan. Provide a garbage management plan as required.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2019
Resolved 20 September 2019
Resolution: Person designated in writing.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 September 2019
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessel did not have a complete first aid kit. Provide approved first aid kit as required.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2019
Resolved 20 September 2019
Resolution: New first aid kit provided with all required contents.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 September 2019
Resolved
Life jackets are required to be marked with the vessels name. 19 life jackets were found not marked with the vessels name. Mark all lifejackets as required.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2019
Resolved 20 September 2019
Resolution: All lifejackets properly marked.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 April 2019
Resolved
A periodic examination made in accordance with the requirements of this subpart shall be of sufficient scope to determine that these items are in a satisfactory conditions for the service intended. Excavate rot in lazarette deckboards and renew to satisfaction of [name withheld] CORRECTED PRIOR TO 2019 SEASONAL SOUTH VOYAGE
46 CFR 176.15-5
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 September 2019
Resolved 10 June 2020
Resolution: Completed satisfactory u/w trial to assess repairs.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 April 2019
Resolved
A periodic examination made in accordance with the requirements of this subpart shall be of sufficient scope to determine that these items are in a satisfactory conditions for the service intended. Complete wormshoe replacement.
46 CFR 176.15-5
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 June 2019
Resolution: Wormshoe replaced in its entirety.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 10 September 2018
Resolved
Vsl is broadcasting greater than expected vessel length and incomplete dimension information (AIS Antenna Position “X” equals 0)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 16 October 2018
Resolution: During a query in VIVS, lengths had been updated and no broadcasting errors existed.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 10 September 2018
Resolved
Vessels operated beyond 20nm must be equipped with a MF-DSC (single side band) radio. Vessel’s single side band radio is inoperable. 47 CFR 80.905(a)(2) Route limited to 20nm.
Action required: 705 - Other - as specified
Resolved 20 September 2018
Resolution: Technician repaired, tested, and issued satisfactory report.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 September 2018
Resolved
All machinery shall be installed to afford protection against fire. Slow fuel leak observed from fuel pump on Engine room fwd bulkhead.46 CFR 182.01-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2018
Resolved 19 September 2018
Resolution: Fuel leak secured
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 September 2018
Resolved
Wiring joints and splices shall be mechanically secure and in junction boxes. Dead end wires in paint locker aft, in battery space, and on new generator install shall be removed or terminated in junction box. Terminal block in Foc’sle port aft bunk shall be mounted. 46 CFR 183.05-50.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2018
Resolved 19 September 2018
Resolution: All wires terminated in junction box or removed
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 10 September 2018
Resolved
Dry pipe vertical exhausts are permissible if suitably insulated. Lagging is missing on upper portion of main engine exhaust. 46 CFR 182.20-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2018
Resolved 19 September 2018
Resolution: Insulation installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 September 2018
Resolved
The number and identification of the items stowed inside and their sizes must be marked in clearly legible letters and numbers on each container for life jackets. Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets. Life jacket stowage not properly marked and child jackets not segregated. 46 CFR 185.604(f); 46 CFR 180.78(a)(5)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2018
Resolved 19 September 2018
Resolution: Life jackets properly stowed and marked
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 10 September 2018
Resolved
Placards containing instructions for the donning and use of life jackets aboard the vessel must be posted. No donning placard posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2018
Resolved 19 September 2018
Resolution: Placards provided and posted
Sail Rigging › Spars › Tangs
Issued 18 April 2018
Resolved
Repair/replace tangs of fwd mast.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2018
Resolved 4 September 2018
Resolution: Replaced.
Sail Rigging › Spars › Masthead Hardware and Sheaves
Issued 18 April 2018
Resolved
Repair/replace fwd mast IWO checks and wedges.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2018
Resolved 4 September 2018
Resolution: Fwd mast replaced with laminated mast.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 18 April 2018
Resolved
Prove proper operation of generator and ventilation shutdown upon activation of installed FF system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 July 2018
Resolved 24 August 2018
Resolution: Tested sat.
Sail Rigging › Spars › Gaffs/Jaws/Saddles/Fittings
Issued 18 April 2018
Resolved
Repairs/replace main mast gaff jaw.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 July 2018
Resolved 24 August 2018
Resolution: Replaced.
Electrical › Electric Generation Source (service) › Generator
Issued 18 April 2018
Resolved
Prove proper operation of aft generator. Old "T" 46 CFR 183.01-15.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2018
Resolved 24 August 2018
Resolution: Tested sat.
Construction/Loadline › Hull › Stiffener
Issued 18 April 2018
Resolved
Excavate rot in ceiling in fish hole on P/S sides. Old "T" 46 CFR 176.25-1.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2018
Resolved 24 August 2018
Resolution: Areas have been repaired.
Construction/Loadline › Structures › Ventilators
Issued 18 April 2018
Resolved
Complete installation of E/R exhaust fan. Old "T" 46 CFR 182.20-45.
Action required: 705 - Other - as specified
Due 20 July 2018
Resolved 24 August 2018
Resolution: Installation complete.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 7 September 2017
Resolved
Prove proper operation of single side band radio. Old T 46 CFR 176.35-15
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 22 September 2017
Resolution: Vessel repaired loose wire found on back of radio and operationally test.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 7 September 2017
Resolved
Provide proper marking for fish hold emergency escape. Old T 46 CFR 185.30-15
Action required: 705 - Other - as specified
Due 21 September 2017
Resolved 18 September 2017
Resolution: Escape hatch was properly labeled.
Electrical › Electric Supply System (service) › Battery Installation
Issued 7 September 2017
Resolved
Repair or replace corroded starboard battery bank tray. Old T 46 CFR 183.05-20(d)
Action required: 705 - Other - as specified
Due 21 September 2017
Resolved 22 September 2017
Resolution: New battery box lining was installed in both battery bank boxes.
Communications › Public Address System › Announcing Station
Issued 7 September 2017
Resolved
Prove proper operation of the public address system.
Action required: 705 - Other - as specified
Due 21 September 2017
Resolved 18 September 2017
Resolution: Public address system was repaired and satisfactorily tested.
Electrical › Lighting (service) › Switch
Issued 8 August 2017
Resolved
Power supply switch and wiring was modified, and hanging unsecured in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2017
Resolved 21 August 2017
Resolution: Examined operation of sailing lights, dist. panel, and wiring.
Sail Rigging › Chainplates › Materials
Issued 4 November 2016
Resolved
Make permanent repairs to forestay chainplates prior to operating with passengers
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 November 2016
Resolution: Renewed port gammon iron.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 12 September 2016
Resolved
Found 03 life jackets with inop water lights, 01 jackets requiring stenciling, and required 02 additional life jackets in ordrer to comply with COI. Vessel total passenger count reduced to 74.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 September 2016
Resolved 22 September 2016
Resolution: Proper number of life jackets, water lights and stenciling.
Lifesaving › Inflatable Liferafts › Servicing
Issued 31 May 2016
Resolved
Vessel must stay one mile from shore while pirmary lifesaving is being serviced.
Action required: 705 - Other - as specified
Due 14 June 2016
Resolved 21 June 2016
Resolution: Verified installation of IBA and Liferaft