Records from 1997 to 2002. Most recent: inspection, 4 September 2002.
Documentation › Manuals/Policy Documentation
Issued 11 July 2002
Resolved
MAKE REVISIONS TO COMPANY SMS PROGRAM FOR MAIN QUALITY PROGRAM MANUAL DATED APRIL 1, 2002.
Action required: 705 - Other - as specified
Due 30 August 2002
Resolved 4 September 2002
Resolution: REVISION MADE ON THE QUALITY PROGRAM MANUAL
Documentation › Manuals/Policy Documentation
Issued 11 July 2002
Resolved
MAKE REVISIONS TO COMPANY SMS PROGRAM FOR OFFICE OPERATION MANUAL DATED JUNE 1, 2002.
Action required: 705 - Other - as specified
Due 30 August 2002
Resolved 4 September 2002
Resolution: REVISION MADE ON THE OFFICE OPERATION MANUAL
Documentation › Manuals/Policy Documentation
Issued 11 July 2002
Resolved
IDENTIFY LANGUAGE ACCEPTABLE FOR OFFICE OPERATION MANUAL IN NORWEGIAN. TO BE MAINTAINED ON BOARD THE VESSEL.
Action required: 705 - Other - as specified
Due 30 August 2002
Resolved 4 September 2002
Resolution: OPERATION MANUAL REVISED INTO ACCEPTABLE LANGUAGE
Documentation › Manuals/Policy Documentation
Issued 11 July 2002
Resolved
PROVIDE PROOF ANNUAL EXAM & CREDIT GIVEN FOR CLASS NOTE TO CONDUCT S. W. BALLAST TANK EXAM.
Action required: 705 - Other - as specified
Due 30 August 2002
Resolved 4 September 2002
Resolution: S.W. BALLAST TANK EXAM CONFIRMED
Documentation › Manuals/Policy Documentation
Issued 11 July 2002
Resolved
IDENTIFY THAT ITEMS LISTED IN 9 JULY 2002 CLASS STATUS NARRATIVE SECTION HAVE BEEN COMPLETED OR ARE IN PROGRESS. TO MEET THE REQUIREMENT OF COMPLETION PRIOR TO FIRST SURVEY AFTER 01 JULY 2002 PER SOLAS REQUIREMENTS.
Action required: 705 - Other - as specified
Due 30 August 2002
Resolved 4 September 2002
Resolution: CONFIRMED THAT ON 24 AUG 02 SOLAS REQUIREMENTS WERE COMPLETED
Documentation › Manuals/Policy Documentation
Issued 11 July 2002
Resolved
ADVISE WRITTEN STATEMENT FROM CLASS FOR COMPLIANCE WITH CLASS NOTE LIF 26-11-98 FOR PERIODICAL TESTING OF LAUNCHING APPLIANCES AND BOAT EQUIPMENT.
Action required: 705 - Other - as specified
Due 30 August 2002
Resolved 4 September 2002
Resolution: CONFIRMED THAT ON 24 AUG 02 THE LAUNCHING APPLIANCES AND BOAT EQUIMENT WERE TESTED
Documentation › Manuals/Policy Documentation
Issued 11 July 2002
Resolved
MAKE REVISIONS TO SHIP OPERATION MANUAL DATED JULY 3, 2002.
Action required: 705 - Other - as specified
Due 30 August 2002
Resolved 4 September 2002
Resolution: OPERATIONS MANUAL WAS REVISED
Documentation › Manuals/Policy Documentation
Issued 11 July 2002
Resolved
ORIGINAL DOCUMENTS IN SHIP OPERATION MANUAL NOT DATED. PROVIDE DOCUMENTATION FOR THE UNDATED MANUAL / PAGES FROM T. B. MANAGEMENT IS MARKED AND IDENTIFIED AS ORIGINAL.
Action required: 705 - Other - as specified
Due 30 August 2002
Resolved 4 September 2002
Resolution: SHIP OPERATIONS MANUAL IN ORDER AND ORIGINAL
Documentation › Manuals/Policy Documentation
Issued 11 July 2002
Resolved
PROVE TRAINING IS BEING PERFORMED PER SMS AS REQUIRED BY COMPANY UNDER IMO RESOLUTION A. 741 (18) SECTION 6.5.
Action required: 705 - Other - as specified
Due 30 August 2002
Resolved 4 September 2002
Resolution: VERIFIED THAT SAFETY TRAINING HAS TAKEN PLACE AND IS DOCUMENTED
Documentation › Manuals/Policy Documentation
Issued 11 July 2002
Resolved
PROVIDE FAMILURIZATION TRAINING REQUIRED FOR NEW CREW MEMBERS PRIOR TO TAKING RESPONSIBILITIES WITHIN 24 HOURS PER SMS AND DOCUMENTATION PROVIDED.
Action required: 705 - Other - as specified
Due 30 August 2002
Resolved 4 September 2002
Resolution: NEW CREW MEMBERS CHECKED IN AND FAMILIARIZED WITH APPROPRIATE WRITTEN DOCUMENTATION OF THE TRAINING.
Lifesaving › Buoyant Apparatus
Issued 25 April 2002
Resolved
LIGHTS ATTACHED TO PORT SIDE/2ND DECK AND STERN/MAIN DECK LIFE RINGS FOUND TO BE INOPERATIVE. HAVE CLASS SURVEYOR PROVIDE REPORT ATTESTING TO REPAIR/REPLACEMENT OF THESE LIGHTS. LEGACY COMPONENT DESC: Light
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 25 April 2002
Resolved 4 May 2002
Resolution: RESOLVED TO SATISFACTION OF CLASS.
Accommodation/Occupational Safety › Occupational Safety
Issued 25 April 2002
Resolved
REMOVE EXCESSIVE AMOUNTS OF OIL FOUND THROUGHOUT MACHINERY SPACES ON DECK PLATING CREATING AN UNSAFE CONDITION FOR CREW MEMBERS. HAVE CLASS SURVEYOR PROVIDE REPORT ATTESTING TO CORRECTION OF THIS CONDITION.
Action required: 15 - Rectify deficiencies by next port
Due 25 April 2002
Resolved 4 May 2002
Resolution: RESOLVED TO SATISFACTION OF CLASS.
Pollution Prevention/Response › Prevention Equipment
Issued 25 April 2002
Resolved
REMOVE TEMPORARY HOSE FROM ENGINE ROOM STBD SIDE SLOP TANK, ENSURE THAT THE REMAINING PIPE IS BLANKED OFF. HAVE CLASS SURVEYOR ISSUE REPORT ATESTING TO REPAIR OF THIS REQUIREMENT. LEGACY COMPONENT DESC: Oily Residue (sludge/slop) Tank
Action required: 15 - Rectify deficiencies by next port
Due 25 April 2002
Resolved 4 May 2002
Resolution: RESOLVED TO SATISFACTION OF CLASS.
Construction/Loadline › Structures
Issued 25 April 2002
Resolved
REPAIR AND HAVE CLASS SURVEYOR ATTEST TO HOLE IN MACHINE SHOP BULKHEAD, STBD SIDE, ABOVE THE DOOR. HAVE CLASS SURVEYOR PROVIDE REPORT ATTESTING TO THIS REQUIREMENT. LEGACY COMPONENT DESC: Longitudinal Bulkhead
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 25 April 2002
Resolved 4 May 2002
Resolution: RESOLVED TO SATISFACTION OF CLASS.
Pollution Prevention/Response › Prevention Equipment
Issued 24 April 2002
Resolved
OWS FOUND TO BE INOPERATIVE. VESSEL ORDERED BY MARINE INSPECTOR TO KEEP ALL OILY WASTES ONBOARD IN SLUGE TANK. HAVE CLASS SURVEYOR PROVIDE REPORT ATTESTING TO PROPER OPERATION OF THIS EQUIPMENT. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 25 April 2002
Resolved 4 May 2002
Resolution: RESOLVED TO SATISFACTION OF CLASS.
Fire Fighting › Fire Pumps
Issued 24 April 2002
No resolution recorded
EMERGENCY FIRE PUMP IN FORCASTLE/BELOW DECKS FOUIND TO BE INOPERATIVE.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 25 April 2002 — due date passed with no resolution recorded
Resolution: EMERGENCY FIRE PUMP REPAIRED, TESTED SATISFACTORY.
Electrical › Lighting (service)
Issued 24 April 2002
Resolved
LIGHTING FIXTURE ABOVE EMERGENCY STEARING GEAR FLAT FOUND TO BE INOPERATIVE. HAVE CLASS SURVEYOR PROVIDE REPORT ATTESTING TO REPAIR OF THIS DESCREPANCY.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 25 April 2002
Resolved 4 May 2002
Resolution: RESOLVED TO SATISFACTION OF CLASS.
Pollution Prevention/Response › Prevention Equipment
Issued 24 April 2002
Resolved
RETAIN ALL OILY WASTES ON BOARD FOR DISPOSAL TO A SHORESIDE FACILITY WHILE OWS IS INOPERABLE. LEGACY COMPONENT DESC: Oily Residue (sludge/slop) Tank
Action required: 15 - Rectify deficiencies by next port
Due 25 April 2002
Resolved 4 May 2002
Resolution: RESOLVED TO SATISFACTION OF CLASS.
Fire Fighting
Issued 27 March 1997
Resolved
Firemans outfit missing tendermans gloves
Condition: Unknown
Due 5 May 1997
Resolved 4 May 2002
Resolution: RESOLVED TO SATISFACTION OF CLASS.
Fire Fighting
Issued 27 March 1997
Resolved
Aux fire pump located in the focastle storage compartment would not take suction after 10min of attempts It was determined the suction opening was above the vessel's waterline during light operations.
Condition: Unknown
Due 15 May 1997
Resolved 15 May 1997