Records from 1985 to 1991. Most recent: inspection, 27 August 1991.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 73
27 August 1991
Damage Survey
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1249445
16 August 1991
Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 937141
7 August 1991
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 466158
22 May 1991
COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1235684
1 November 1990
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 906543
21 September 1990
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1210813
22 August 1990
Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 926551
17 August 1990
Examination of Repairs
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 923312
16 July 1990
Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 904077
17 May 1990
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 474291
16 May 1990
COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 931745
16 November 1989
Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1211501
13 October 1989
Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1346367
12 September 1989
Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1207577
17 August 1989
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 534668
31 July 1989
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 504072
11 July 1989
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 896675
18 May 1989
COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1344092
8 March 1989
Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1201554
27 February 1989
Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1195339
14 November 1988
Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1202458
29 September 1988
Examination of Repairs
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1195163
26 August 1988
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1351400
22 August 1988
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1043466
16 August 1988
Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1351397
9 July 1988
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1208026
5 July 1988
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1206884
1 July 1988
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 895883
30 June 1988
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 895859
28 June 1988
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 895856
3 June 1988
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1196866
24 May 1988
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1352229
23 May 1988
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1352316
20 May 1988
COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1037877
25 April 1988
Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1341907
14 April 1988
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1035020
6 April 1988
Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1302531
1 April 1988
Examination of Repairs
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 994927
23 March 1988
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 992991
15 March 1988
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1337367
10 March 1988
Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 989366
7 March 1988
Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1293803
4 March 1988
Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1028797
24 February 1988
Examination of Repairs
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1333492
22 February 1988
Damage Survey
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1331868
19 February 1988
Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1331347
18 February 1988
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1329801
17 February 1988
Examination of Repairs
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1021824
3 February 1988
Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1017731
3 February 1988
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1018675
27 January 1988
Examination of Repairs
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1323504
26 January 1988
Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1014424
30 November 1987
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1339080
12 November 1987
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1024546
9 November 1987
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1023403
6 November 1987
Hull Examination
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1023573
3 November 1987
Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1328155
27 October 1987
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1019649
20 October 1987
Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1016027
15 October 1987
Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1322856
8 October 1987
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1326005
7 October 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1010945
2 September 1987
Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1310989
14 July 1987
Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1020036
25 June 1987
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1009205
30 December 1986
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1311176
2 July 1986
Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1001433
6 June 1986
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 988486
5 June 1986
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 987011
20 November 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 995561
30 August 1985
Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1298886
26 July 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1287624
1 June 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 979847
Engineering
Issued 22 May 1991
Resolved
PROVIDE APPROVED PLANS FOR, AND INSTALLATION OF, STARTING AIR SYSTEM WITH SUFFICIENT CAPACITY TO START THE MAIN DIESEL ENGINE TWELVE TIMES, WHILE MAINTAINING SUFFICIENT CONTROL AIR TO OPERATE THE PROPULSION MACHINERY WITHOUT RECHARGING THE SYSTEM. REF.; 46CFR71.15-1, ABS STEEL RULES SEC 34.37.
Condition: Unknown
Due 1 June 1992
Resolved 24 January 2002
Electrical
Issued 21 September 1990
Resolved
PROVIDE GROUNDED PLUGS ON MAIN DECK GALLEY ELECTRICAL APPLIANCES, PRESENTLYWITH GROUND PRONGS REMOVED. THIS ITEM WAS PREVIOUSLY ITEM D.10. IN CASE MI90029393.
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Accommodation/Occupational Safety
Issued 21 September 1990
Resolved
SECURE THE SODA FOUNTAIN CO2 BOTTLES LOCATED IN THE PORT AND STBD MAIN DECKGALLEYS AGAINST MOVEMENT.
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Electrical
Issued 21 September 1990
Resolved
PROVIDE A COVER ON THE JUNCTION BOX UNDER THE STBD GALLEY COUNTER.
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Engineering
Issued 21 September 1990
Resolved
PROVIDE HEAT DEFLECTORS ON THE FOUR (4) RACOR FUEL FILTERS ON THE PORT AND STBD GENERATORS.
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Lifesaving
Issued 22 August 1990
Resolved
RENEW THE BUOYANT APPARATUS WEAK LINKS WITH A TYPE MADE OF CORROSION RESIS-TANT MATERIAL.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Lifesaving
Issued 22 August 1990
Resolved
RENEW THE GRABLINE ON THE MIDDLE 20 MAN BUOYANT APPARATUS.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Electrical
Issued 22 August 1990
Resolved
PLUG THE MISSING KNOCKOUTS ON THE REEFER ELECTRICAL BOX IN THE SHAFT ALLEY SPACE.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Fire Fighting
Issued 22 August 1990
Resolved
PROVIDE A CG OR UL APPROVED MARINE TYPE BII FIRE EXTINGUISHER, WITH BRACKET, FOR THE SALON DECK SNACK BAR.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Electrical
Issued 22 August 1990
Resolved
REMOVE THE SPLICE AND PROPERLY MOUNT THE RECEPTACLE UNDER THE GRILL IN THE SALON DECK SNACK BAR.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Navigation
Issued 22 August 1990
Resolved
STENCIL THE GENERAL ALARM BELL ON THE MAIN DECK FORWARD BHD.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Lifesaving
Issued 22 August 1990
Resolved
DEMONSTRATE OPERATION OF THE LANTERN FOR THE #2 LIFEBOAT.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Fire Fighting
Issued 22 August 1990
Resolved
PROVIDE SPANNER WRENCHES AT FIRE STATIONS #2 AND #4.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Electrical
Issued 22 August 1990
Resolved
PROPERLY DEAD END THE EXPOSED WIRES ON THE MAIN DECK REEFER, PORTSIDE.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Electrical
Issued 22 August 1990
Resolved
PROVIDE GROUNDED PLUGS ON MAIN DECK GALLEY ELECTRICAL APPLIANCES, PRESENTLYWITH GROUND PRONGS REMOVED.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Accommodation/Occupational Safety
Issued 22 August 1990
Resolved
DEMONSTRATE OPERATION OF WATER TO THE URINALS IN THE SALON DECK MEN'S HEAD.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Electrical
Issued 22 August 1990
Resolved
PROVIDE GLOBES ON THE LIGHTS IN THE SALON DECK SNACK BAR AND SHAFT ALLEY COMPANIONWAY.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Electrical
Issued 22 August 1990
Resolved
REPAIR WIRING ON BOW THRUSTER, INSTALL PROPER TERMINATIONS ON WIRES, REMOVE DEAD WIRE RUNS.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Deck/Cargo
Issued 22 August 1990
Resolved
REMOVE OR REPLACE BOW THRUSTER OIL PRESSURE SENDER.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Electrical
Issued 22 August 1990
Resolved
MOUNT PERMANENTLY D.C. GENERATOR BATTERY CHARGER.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Electrical
Issued 22 August 1990
Resolved
INSTALL COVER ON LIGHTING JUNCTION BOX (STBD SIDE AMIDSHIPS, MAIN DECK.)
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Fire Fighting
Issued 22 August 1990
Resolved
INSTALL NEW GLASS IN CO2 PULL BOX (STBD SIDE AMIDSHIPS, MAIN DECK.)
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Electrical
Issued 22 August 1990
Resolved
INSTALL BLANKIN 110VAC BREAKER PANEL, AND LABLE BREAKERS, (STBD SIDE OF E/RCONTROL PLATFORM.)
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Electrical
Issued 22 August 1990
Resolved
INSTALL COVER ON WIRING JUNCTION BOX, (STBD SIDE OF E/R CONTROL PLATFORM.)
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Electrical
Issued 22 August 1990
Resolved
REPAIR OR REMOVE UNUSED FLORESCENT LIGHTING FIXTURES IN E/R CONTROL PLATFORM, OVERHEAD AFT.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
REPAIR OR REPLACE PRESSURE SWITCH FOR LOWER AIR COMPRESSOR IN E/R.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Electrical
Issued 22 August 1990
Resolved
MOUNT PERMANENTLY BOW THRUSTER BATTERY CHARGER.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 13 October 1989
Resolved
PERMANENTLY MOUNT MAIN ENGINE SHAFT TACK SENDING UNIT.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Electrical
Issued 13 October 1989
Resolved
HARD WIRE BATTERY CHARGER TO BOW THRUSTER STARTING BATTERIES.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Electrical
Issued 13 October 1989
Resolved
INSTALL NECESSARY BLANKS IN 110 FEEDER BOX ON FACE OF ENGINE ROOMS SWITCHBOARD.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Electrical
Issued 13 October 1989
Resolved
INSTALL COVER AND BLANK OFF MISSING KNOCK OUTS ON SWITCH BOX MOUNTED ON SIDE OF D/C CONTROL BOX.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Electrical
Issued 13 October 1989
Resolved
INSTALL LUGS ON WIRES TO BRIDGE MAIN ENGINE TACK AT CONNECTION BY ENGINE ROOM CONTROL STATION.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Engineering
Issued 13 October 1989
Resolved
REPAIR OR RENEW FRAYED ENGINE ORDER TELEGRAPH CABLE ABOVE STBD MAIN DECK ENTRY DOOR.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Accommodation/Occupational Safety
Issued 13 October 1989
Resolved
CLEAN GRILL HOOD VENT FAN AND DUCTING AT GRILL IN SALON DECK BAR.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Accommodation/Occupational Safety
Issued 13 October 1989
Resolved
PROPERLY SECURE CO2 GAS BOTTLES FOR SODA DISTRIBUTION SYSTEM PORT SIDE MAIN DECK.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Accommodation/Occupational Safety
Issued 13 October 1989
Resolved
SECURE BUFFET LINE HEATING CONTROL PANELS, PORT SIDE MAIN DECK
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Electrical
Issued 13 October 1989
Resolved
PERMANENTLY INSTALL ELECTRICAL OUTLETS PORT SIDE MAIN DECK BUFFET AREA
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Electrical
Issued 13 October 1989
Resolved
REPLACE PLUG ON ICE CREAN FREEZER PORT SIDE MAIN DECK BACK OF BUFFET LINE WITH 3-PRONG PLUG
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Construction/Loadline
Issued 13 October 1989
Resolved
ENSURE ALL DOGS ON WATERTIGHT DOOR AFT BELOW MAIN DECK OPERATES EASILY AND SECURES EFFECTIVELY, RENEW EXISTING HING BOLTS.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Construction/Loadline
Issued 13 October 1989
Resolved
RENEW LOWER HINGE PIN ON WATERTIGHT DOOR AFT MAIN DECK STEERING STATION.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Engineering
Issued 13 October 1989
Resolved
RENEW FLAME SCREEN ON PORT SIDE FUEL OIL VENT.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Electrical
Issued 13 October 1989
Resolved
RENEW OR MAKE PERMANENT REPAIRS TO CRACK IN FLEXABLE SECTION OF D/C GENERATOR EXHAUST LINE.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Electrical
Issued 13 October 1989
Resolved
BLANK OFF MISSING KNOCK OUTS ON LOWER AIR COMPRESSOR CONTROLLER.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Fire Fighting
Issued 11 July 1989
Resolved
REPAIR GENERAL SERVICE PUMP AND MOTOR AND PROVE OPERATION OF PUMP BEFORE OPERATION OF VESSEL. PUMP BROKEN DUE TO AGE AND WEAR MOTOR BURNT OUT DUE TOPUMPS IMPROPER OPERATION. CORRECTED 14 JULY 89.
Condition: Unknown
Due 11 July 1989
Resolved 11 July 1989
Electrical
Issued 18 May 1989
Resolved
MAKE PERMANENT REPAIRS TO DC GENERATOR TACHOMETER
Condition: Unknown
Due 18 May 1989
Resolved 18 May 1989
Navigation
Issued 26 August 1988
Resolved
MAKE PERMANENT REPAIRS TO THE RUDDER STOCK
Condition: Unknown
Due 26 August 1988
Resolved 26 August 1988
Engineering
Issued 16 August 1988
Resolved
REPAIR LEAK IN PORT FUEL TANK SUPPLY VALVE AT TANK.
Condition: Unknown
Due 16 August 1988
Resolved 16 August 1988
Navigation
Issued 16 August 1988
Resolved
INSTALL GUARD OVER HYDRAULIC PUMP COUPLING FOR STEERING SYSTEM.
Condition: Unknown
Due 16 August 1988
Resolved 16 August 1988
Electrical
Issued 16 August 1988
Resolved
ENCLOSE FORWARD SIDE OF MAIN ENGINE ROOM SWITCH BOARD
Condition: Unknown
Due 16 August 1988
Resolved 16 August 1988
Documentation
Issued 16 August 1988
Resolved
PROVIDE DECK LOG BOOK & STABILITY LETTER ON BOARD
Condition: Unknown
Due 16 August 1988
Resolved 16 August 1988
Electrical
Issued 16 August 1988
Resolved
PROVE OPERATION OF PORT SHIPS SERVICE GENERATOR WHEN D/C EXCITATION MOTOR INSTALLED
Condition: Unknown
Due 16 August 1988
Resolved 16 August 1988
Construction/Loadline
Issued 16 August 1988
Resolved
REPAIR LEAK ON FORWARD SIDE OF PORT HAUS PIPE
Condition: Unknown
Due 16 August 1988
Resolved 16 August 1988
Deck/Cargo
Issued 30 June 1988
Resolved
PROVE PROPER OPERATION OF BOW THRUSTER PRIOR TO VESSEL OPERATION.
Condition: Unknown
Due 30 June 1988
Resolved 30 June 1988
Electrical
Issued 30 June 1988
Resolved
PROVE PROPER OPERATION OF VOLTMETER ON MAIN PANEL FOR PORT GENERATOR.
Condition: Unknown
Due 30 June 1988
Resolved 30 June 1988
Navigation
Issued 28 June 1988
Resolved
PROVE PROPER OPERATION OF STEERING GEAR PRIOR TO VESSEL OPERATIONS.
Condition: Unknown
Due 28 June 1988
Resolved 28 June 1988
Navigation
Issued 24 May 1988
Resolved
PROVE PROPER OPERATION OF THE PILOT HOUSE SHAFT TACHOMETER AND DIRECTION INDICATOR. (46CFR113.37)
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Navigation
Issued 24 May 1988
Resolved
PROVE PROPER OPERATION OF THE ENGINE ROOM CONTROL STATION SHAFT TACHOMETER AND DIRECTION INDICATOR. (46CFR113.37)
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Engineering
Issued 24 May 1988
Resolved
PROVIDE MEANS TO PREVENT THE FOREPEAK FROM BEING FLOODED IN THE EVENT THAT THE BILGE PIPING IS SEVERED OR OTHERWISE DAMAGED IN ANY OTHER COMPARTMENT. (46CFR113.37)
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Documentation
Issued 23 May 1988
Resolved
PAINT THE DRAFT AND PLIMSOLL MARKS
Condition: Unknown
Due 23 May 1988
Resolved 23 May 1988
Lifesaving
Issued 23 May 1988
Resolved
PROVIDE LIGHTING FOR LIFEBOAT LAUNCHING AREA FROM THE UPPER DECK TO THE WATER'S EDGE.
Condition: Unknown
Due 23 May 1988
Resolved 23 May 1988
Deck/Cargo
Issued 20 May 1988
Resolved
PROVE PROPER OPERATION OF BOW THRUSTER OIL GAUGE ON BRIDGE.
Condition: Unknown
Due 20 May 1988
Resolved 20 May 1988
Electrical
Issued 20 May 1988
Resolved
PROVE PROPER OPERATION OF THE TACHOMETER ON THE DC GENERATOR PRIME MOVER.
Condition: Unknown
Due 20 May 1988
Resolved 20 May 1988
Electrical
Issued 20 May 1988
Resolved
PROVIDE APPROPRIATE RUBBER MATTING IN FRONT OF MAIN ELECTRICAL SWITCHBOARD IN THE ENGINEROOM.
Condition: Unknown
Due 20 May 1988
Resolved 20 May 1988
Construction/Loadline
Issued 20 May 1988
Resolved
MAKE PERMANENT REPAIRS TO HULL IN WAY OF FR 75 & 76 ABOVE THE WATERLINE PORT SIDE
Condition: Unknown
Due 20 May 1988
Resolved 20 May 1988
Construction/Loadline
Issued 22 February 1988
Resolved
MAKE PERMANENT REPAIRS TO WASTED HULL PLATE AT FRAME 53 STBD., BETWEEN FIRST & SECOND LONGITUDINAL.
Condition: Unknown
Due 22 February 1988
Resolved 22 February 1988
Navigation
Issued 25 June 1987
Resolved
SWING THE COMPASS AND POST A DEVIATION TABLE IN THE WHEEL HOUSE.
Condition: Unknown
Due 25 June 1987
Resolved 25 June 1987
Fire Fighting
Issued 25 June 1987
Resolved
CONDUCT A FIRE AND BOAT DRILL IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 25 June 1987
Resolved 25 June 1987