← All vessels
AFIYA
AFIYA is a 1990 freight ship. The Coast Guard has recorded 37 inspections since 1994, most recently in June 2008, along with 38 deficiencies and 9 operational controls.
Records from 1994 to 2008. Most recent: operational control imposed, 24 June 2008.
- Built
- 1990
- Last inspected
- 23 June 2008
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 38 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8814342 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HAJ8
418310
Flag
MALTA
—
Maury page id
psix-418310
Inspections, by type
The 37 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it4371 - Convention (Subpart B), Gross Ton
1981 - Convention (Subpart B), Net Ton
5177 - Dead Weight, Ton
7753 - Displacement, Ton
1981 - Convention (Subpart B), Net Ton
5177 - Dead Weight, Ton
7753 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 37
23 June 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3246046
20 June 2008
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3242681
19 June 2008
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3241575
22 May 2008
MARPOL Annex I Examination · MARPOL Annex V Examination · ISM Exam · Administrative Inspection · ISPS II Exam · Loadline Exam · PII Safety Exam · Ballast Water Examination · ILO-147 Exam · STCW 95 Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3213369
29 June 2007
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2977508
15 June 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2962504
10 June 2007
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2957140
9 June 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2961412
18 March 2007
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2890075
18 March 2007
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2890750
20 January 2007
ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2858959
6 September 2006
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2771118
5 September 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2769991
10 February 2004
Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2003811
15 August 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1876974
14 August 2003
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1879491
15 June 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1819305
14 February 2003
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1744772
22 November 2002
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1709264
12 November 2002
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1704032
8 November 2002
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1703084
8 November 2002
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1703189
21 January 2002
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1481866
10 June 2000
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 278679
12 July 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 430626
14 June 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 429707
11 December 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 423726
4 October 1996
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 395860
23 June 1996
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 392385
20 December 1995
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 385781
2 October 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 383395
2 October 1995
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 883038
4 June 1995
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 378973
3 February 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 375464
5 January 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 708408
20 December 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 373621
20 December 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1403879
Deficiency record · 38
Construction/Loadline › Structures › Door
Issued 22 May 2008
Resolved
Doors on superstructure wasting away around outer edge holding gasket in. Gasket on doors indented and has excessive gaps at joints and building in corners.
Lifesaving › Lifeboat Equipment › Searchlight
Issued 21 May 2008
Resolved
Port and starboard lifeboat missing spare tools (engine) and searchlights.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 21 May 2008
Resolved
Forward starboard cargo hatch locking mechanism hydraulic cylinder and port aft cylinder leaking hydraulic fluid.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 21 May 2008
Resolved
No markings on bow for bulbous nose or bow thruster. To be repaired during next available dry dock to satisfaction of class.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 21 May 2008
Resolved
Sewage Tank has broken pipe on the top with large hole. Also has hose placed in spot where another pipe once was. Smell of sewage coming from tank.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 21 May 2008
Resolved
Signs of major exhaust leak on #1 main propulsion engine.
Engineering › Thrusters › Motor
Issued 21 May 2008
Resolved
Bow thrusting unit inoperable. To be repaired during next available dry dock to satisfaction of class.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 10 June 2007
Resolved
Vessel was involved in a pollution incident on 09Jun2007. The cause of the pollution was wasted steel along the bottom of the #5 portside fuel tank vent containment. Issued a requirment that the containment be repaired by the next U.S. port after sailing foreign.
Construction/Loadline › Structures › Plowshare Breakwater
Issued 18 March 2007
Resolved
Vessel has damage on Stbd side of bow due to collision with bridge. Class must report and make recommendations prior to vessel sailing.
Navigation › Collision/Grounding Avoidance › Radar
Issued 20 January 2007
Resolved
Vessel had electrical work done on their alert system. It is believed that the electrical supply to radar was disconnected during maintenance. The satisfactionn of Coast Guard
Engineering › Steering Gear System › Rudder Bearing
Issued 20 January 2007
Resolved
During steering test, observed hydraulic leak from steering gear system. To the satisfaction of Classification society surveyor.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Block
Issued 6 September 2006
Resolved
One of Two main generators was found with a water leak in the raw water cooling line. Solas II-I reg 26
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 6 September 2006
Resolved
The current configuration of the OWS system allows for the illegal discharge of oil by way of oil content meters bypass valve. Provide class report attesting to proper configuration of OWS system.
Pollution Prevention/Response › Prevention Equipment
Issued 12 November 2002
Resolved
Repair OWS; have class attest to proper repair and prove satisfactory operation in presence of USCG inspector. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Operations/Management › Vessel Safety Management › Resources and Personnel
Issued 12 November 2002
Resolved
Prove vessel is ISM compliant.
Electrical › Electric Generation Source (emergency)
Issued 21 January 2002
Resolved
Emergency generator fail to start on automatic, could be started manually. LEGACY COMPONENT DESC: Generator
Lifesaving
Issued 20 December 1995
Resolved
REPAIR OR REPLACE ALL UNSERVICABLE LIFE RINGS. (DRY ROTTED)
Engineering
Issued 20 December 1995
Resolved
PROVIDE POLLUTION PLACARD IN MACHINERY SPACE. (MISSING)
Documentation
Issued 20 December 1995
Resolved
PROVIDE ON BOARD ORIGINAL SAFE MANNING CERTIFICATE. (FAXED COPY ON BOARD)
Navigation
Issued 20 December 1995
Resolved
PROVIDE NON-SKID MATERIAL FOR DECK IN AFTER STEERING. (MISSING)
Lifesaving
Issued 20 December 1995
Resolved
REPLACE 02 SMOKE FLARES ON PORT AND STARBOARD BRIDGE WINGS. (EXPIRED DATES)
Lifesaving
Issued 20 December 1995
Resolved
SERVICE ALL LIFE JACKETS. (MISSING LIGHTS)
Fire Fighting
Issued 20 December 1995
Resolved
PROVIDE FIRE HOSE AND DUAL PURPOSE NOZZLE FOR EACH FIRE STATION. (NUMEROUSNOZZLES MISSING)
Electrical
Issued 20 December 1995
Resolved
PROVIDE NON-CONDUCTIVE MATERIAL FOR DECK IN EMERGENCY GENERATOR SPACE. (MISSING)
Navigation
Issued 20 December 1994
Resolved
VESSEL DID NOT HAVE A COPY OF THE LIGHT LIST.
Unknown
Issued 20 December 1994
Resolved
VESSEL DID NOT HAVE ADEQUATE MEANS OF COMMUNICATING DURING TRANSFER OPERATIONS.
Engineering
Issued 20 December 1994
Resolved
VESSEL DID NOT HAVE OVERBOARD SCUPPERS PROPERLY CLOSED DURING TRANSFER OPERATIONS.
Lifesaving
Issued 20 December 1994
Resolved
VESSEL DID NOT HAVE WARNING SIGNALS DISPLAYED DURING TRANSFER OPERATIONS.
Engineering
Issued 20 December 1994
Resolved
VESSELS' FUEL OIL TANK VENTS CONTAINMENT WAS NOT PROPERLY CLOSED DURING TRANSFER OPERATIONS.
Lifesaving
Issued 20 December 1994
Resolved
CREWMAN WAS SMOKING AT TRANSFER SITE DURING TRANSFER OPERATIONS.
Navigation
Issued 20 December 1994
Resolved
VESSELS CHARTS WERE NOT CURRENTLY CORRECTED.
Navigation
Issued 20 December 1994
Resolved
VESSELS' U.S. COAST PILOT NOT CURRENTLY CORRECTED.
Navigation
Issued 20 December 1994
Resolved
VESSEL DID NOT HAVE TIDAL CURRENT TABLE PUBS. FOR 1994.
Engineering
Issued 20 December 1994
Resolved
VESSEL DID NOT HAVE TRANSFER PROCEDURES AT THE TRANSFER SITE.
Engineering
Issued 20 December 1994
Resolved
VESSELS' TRANSFER PROCEDURES WERE INCOMPLETE.
Navigation
Issued 20 December 1994
Resolved
VESSELS MANEUVERING FACT SHEET DID NOT HAVE WARNING STATEMENT LISTED ON IT.
Navigation
Issued 20 December 1994
Resolved
VESSEL DID NOT HAVE A BLOCK-STEERING DIAGRAM ON THE BRIDGE.
Lifesaving
Issued 20 December 1994
Resolved
REPLACE PROVISIONS BOTH LIFEBOATS NEXT U. S. PORT.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.