Documentation record
Registered dimensions (L × B × D)107.0 ft × 24.5 ft × 11.0 ft
Registered tonnagegross 134 / net 134
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJOHN F. JAMES & SON · ESSEX, MA, UNITED STATES · built 1926
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portGLOUCESTER, MA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 9 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it134 - Regulatory (Subpart C or D), Gross Ton
134 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 17 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 17
26 May 2026
COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8345246
3 March 2025
Damage Survey · Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8109964
3 November 2023
Internal Structural Exam · Annual Inspection · Hull Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7819978
14 June 2023
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7714712
19 May 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7493241
30 March 2022
Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7412943
25 June 2021
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7225773
3 March 2021
Hull Examination · Construction Oversight
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7149400
24 April 2020
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6943279
25 November 2019
Drydock Extension
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6862097
24 July 2019
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6754455
14 June 2019
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6713692
29 October 2018
Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6570378
24 May 2018
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6421635
23 October 2017
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6292888
27 July 2017
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6221548
14 March 2016
Annual Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5833491
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 May 2026
Resolved
A vessel must have one or more ring life buoys...at least one ring life buoy must be fitted with a lifeline...a vessel must carry one floating waterlight. 02 of the vessel's ring life buoy's were deteriorated and there was no floating waterlight.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 June 2026
Resolution: Operator installed new liferings with a new floating water light.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 March 2025
Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Vessel has combustible waste receptacles on board. Remove or replace all receptacles with ones that are of noncombustible material.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2025
Resolution: Operator replaced all combustible trash cans.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 25 June 2021
Resolved
Flexible or portable cords such as SO, STO, and similar types cannot be used for permanent wiring. The vessel was utilizing a portable cord for the reefer unit.
46CFR183.10-20(a)(3)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2021
Resolved 19 January 2022
Resolution: Verified proper installation as per approved line drawing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 July 2019
Resolved
Vessels constructed of wood must provide bilge level alarms in all watertight compartments except small buoyancy chambers. No bilge alarm installed in fore peak. Provide required bilge high level alarm as required.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2019
Resolved 22 August 2019
Resolution: Witness operational test of newly installed bilge alarm for fore peak space, observed functional visual and audible alarm.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 24 July 2019
Resolved
Each survival craft must be stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. IBA float free link and hydrostatic link installation not properly configured.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 24 July 2019
Resolution: Vessel operator corrected on the spot.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 24 July 2019
Resolved
When operating a vessel on a body of water where the discharge of untreated sewage is prohibited bt the EPA under 40 CFR 140.3, the operator must secure each Type III device in a manner which prevents the discharge of sewage. Acceptable methods of securing the device include -
(1) Closing each valve leading to an overboard discharge and removing the handle;
(2) Padlocking each valve leading to an overboard discharge in the closed position; or
(3) Using a non-releaseable wire-tie to hold each valve leading to an overboard discharge in the closed position.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 August 2019
Resolution: Vessel operator secured overboard discharge valves forward and aft for black water with plastic ties.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 24 July 2019
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board to determine the presence of alcohol in the system of crew members. Alcohol test strips expired. Provide required alcohol testing strips.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 August 2019
Resolution: Vessel operator provided valid alcohol testing devices readily accessible on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 July 2019
Resolved
Each ring life buoy on a vessel must:
(1) Be approved in accordance with §160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. All 3 required life rings have installed line that does not meet the conditional requirements of sub chapter Q. Provide 03 new life rings.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 August 2019
Resolution: Vessel operator replaced 3 new life buoy's.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 24 July 2019
Resolved
For fixed-gas fire extinguishing systems the owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. No record of fixed fire suppression system available. Provide servicing report listing components of fixed system tested
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 August 2019
Resolution: Vessel operator emailed fire safety technician report, properly testing, override and shutdown of machinery space fire suppression system.
Construction/Loadline › Hull › Hull Plating
Issued 8 November 2017
Resolved
Conduct underway/under-sail sea trials after installation of all rigging is complete.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2018
Resolution: Conducted u/w sea trial IAW sail plan.