HELENE is a 1927 passenger vessel (inspected). The Coast Guard has recorded 27 inspections since 1985, most recently in September 2006, along with 87 deficiencies — 44 with no resolution recorded — and 1 casualty investigation in 2006.

Records from 1985 to 2006. Most recent: casualty investigation, 2 November 2006.

Built
1927
Last inspected
18 September 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WBF5294
Flag
UNITED STATES
—
Maury page id
psix-41837

Inspections, by type

…with no type recorded4
…past their stated due date44
Years with a record 21 calendar years (1985–2006)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCX7806MMSI not assigned · expired · compulsorily equipped · granted 3 October 1997, cancelled 8 December 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 27

18 September 2006 COI Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2763746
3 September 2004 Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 2192521
2 July 2003 Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1855094
18 January 2002 COI Inspection · Hull Examination
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1616558
5 June 2001 Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1066657
5 July 2000 Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1361746
27 May 1999 COI Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1365227
25 June 1998 Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1415017
14 July 1997 Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1375052
16 April 1997 Hull Examination
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1437224
28 May 1996 COI Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1394552
16 May 1995 COI Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1444978
13 May 1994 COI Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1454093
18 May 1993 COI Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1370612
11 May 1992 Hull Examination · COI Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 959975
8 May 1991 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1230383
29 April 1991 COI Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1211476
25 April 1990 COI Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1228301
10 July 1989 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1343138
2 May 1989 COI Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 893063
31 May 1988 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 887329
2 May 1988 COI Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1342985
24 June 1987 Excursion Permit
Administrative · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1314134
13 May 1987 COI Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1330065
7 November 1986 Hull Examination
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1014022
14 May 1986 COI Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1297351
3 May 1985 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 980368

Deficiency record · 87

Electrical › Lighting (service) › Lighting Fixture
Issued 20 October 2006 No resolution recorded
Remove electrical light installation and cap off water penetration in the aft laz.
Action required: 705 - Other - as specified
Due 20 October 2006 — due date passed with no resolution recorded
Construction/Loadline › Penetrations › Pipe Flange
Issued 20 October 2006 No resolution recorded
Remove degausing piping in aft laz and install perminant inserts aft and fwd blkd for water tight integrity.
Action required: 705 - Other - as specified
Due 20 October 2006 — due date passed with no resolution recorded
Stability › Watertight Integrity › General
Issued 20 October 2006 No resolution recorded
Double overboard hosein laz.
Action required: 705 - Other - as specified
Due 20 October 2006 — due date passed with no resolution recorded
Stability › Watertight Integrity › General
Issued 20 October 2006 No resolution recorded
Install peminant thru hull valve for laz drain.
Action required: 705 - Other - as specified
Due 20 October 2006 — due date passed with no resolution recorded
Engineering › Steering Gear System › Linkage
Issued 20 October 2006 No resolution recorded
Remove/clean/reinstall stbd side laz sheeve at the steering quadrant.
Action required: 705 - Other - as specified
Due 20 October 2006 — due date passed with no resolution recorded
Engineering › Steering Gear System › Linkage
Issued 20 October 2006 No resolution recorded
Reinstall as original steering wire rope and ensure all "D" rings are moused at wire rope and ensure adjustments are double nutted.
Action required: 705 - Other - as specified
Due 20 October 2006 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 September 2006 No resolution recorded
Noted multiple dead end wires to Master requiring removal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 18 September 2006 No resolution recorded
Watertight gland needed for black water piping through aft main space bulkhead.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Potable Water System › General
Issued 18 September 2006 No resolution recorded
Conduct perm. repairs to soft patch on potable water pipe.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 18 September 2006 No resolution recorded
Re0install lagging missing from port and starboard exhaust piping.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Engineering › Diesel Engine (propulsion-direct drive) › Piping (air intake)
Issued 18 September 2006 No resolution recorded
Replace marine sanitation device hose on main engine with approved negative pressure hose.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Engineering › Diesel Engine (propulsion-direct drive) › Piping (air intake)
Issued 18 September 2006 No resolution recorded
Properly install clamps on main engine breather piping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 18 September 2006 No resolution recorded
Re-install as orignal MDE tachometer.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 September 2006 No resolution recorded
Properly support all wiring in Main Space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 18 September 2006 No resolution recorded
Permanently repair MDE head gasket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Construction/Loadline › Penetrations › Bottom Plug
Issued 18 September 2006 No resolution recorded
Replace wasted scupper drain pipes.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Engineering › Diesel Engine (auxiliary) › Block
Issued 18 September 2006 No resolution recorded
Replace SSG 1, due to fracture in jacket water of block (6' X 12') Steel patch inserted as temp. repair.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Construction/Loadline › Penetrations › Bottom Plug
Issued 18 September 2006 No resolution recorded
Install operational thru hull valves for shell plating penetrations..
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Fire Fighting › Fire Pumps › Suction Valve
Issued 18 September 2006 Resolved
Ship unable to prove proper operation of skin valve on fire pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 September 2006
Resolution: collected in seperate def.
Engineering › Bilge Water Management System › Valve
Issued 18 September 2006 No resolution recorded
Valve #4 in bildge manifold requires removal and capping.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Fire Fighting › Fire Main › Valves
Issued 18 September 2006 No resolution recorded
1. Vessel personnel unable to prove proper operation of the fire main pressure relief valve. 2. Vessel personnel unable to prove proper operation of valve in way of the port generators water tank. 3. Vessel personnel unable to prove proper operation of through hull valve under aft porthole.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Construction/Loadline › Penetrations › Weld
Issued 18 September 2006 No resolution recorded
Prove water/weather tight integrity of portholes.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 18 September 2006 No resolution recorded
Remove oil from bilges.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 September 2006 No resolution recorded
Rewire 120v connections at starboard a/c generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 18 September 2006 No resolution recorded
Double clamp fresh water supply to starboard generator.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 18 September 2006 No resolution recorded
Replace/repair 12v ground wire in bus.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Electrical › Electric Supply System (service) › Cable
Issued 18 September 2006 No resolution recorded
Properly install 2nd battery in starboard battery box, with correct guage wire for load.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 18 September 2006 No resolution recorded
Replace ground wire to A/C generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 18 September 2006 No resolution recorded
Hydro.UPV and bench pressure relief valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Engineering › Freshwater System (jacketwater cooling) › Storage Tank
Issued 18 September 2006 No resolution recorded
Permanently repair epoxy weld on starboard side jacket water exhaust MDE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 18 September 2006 No resolution recorded
Instal isolation bus for start batteries.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Engineering › Fuel Oil Service System › Piping
Issued 18 September 2006 No resolution recorded
Properly secure and tighten all loose fuel line connections.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Engineering › Freshwater System (jacketwater cooling) › Storage Tank
Issued 18 September 2006 No resolution recorded
Reinstall failed jacket water heat exchanger on MDE
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 18 September 2006 Resolved
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 September 2006
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 18 September 2006 No resolution recorded
Re-instal- Heat exchanger mounting bolts missing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Washroom/Toilet › Shower/Bathtub
Issued 18 September 2006 No resolution recorded
Blank off or re-route grey water line from showe.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Panelboard
Issued 18 September 2006 No resolution recorded
Properly secure and install all wiring in "C" panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 18 September 2006 No resolution recorded
Conduct permanent repairs to the 120/12v above water tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Engineering › Bilge Water Management System › Interface Detector
Issued 18 September 2006 No resolution recorded
Prove proper operation of bilge water alarms both fore and aft.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Stability › Watertight Integrity › General
Issued 18 September 2006 No resolution recorded
Make main deck water tight. (O/O to provide rec. for perm repairs to failed under deck supports)
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Cable
Issued 18 September 2006 No resolution recorded
Remove all unused open ended wires.
Action required: 705 - Other - as specified
Due 18 September 2006 — due date passed with no resolution recorded
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 3 September 2004 No resolution recorded
Operator does not possess a valid FCC Operator's Permit.
Due 30 September 2004 — due date passed with no resolution recorded
Lifesaving › Lifefloat › Lifeline
Issued 3 September 2004 No resolution recorded
Grablines and stitching attachments on upper lifefloat were deteriorated and need to be renewed as indicated.
Due 17 September 2004 — due date passed with no resolution recorded
Documentation › Logs/Records › Logbook (official)
Issued 3 September 2004 No resolution recorded
Official logs need to be better organized and maintained for the following: VHF radio, crew emergency drills, passenger count, safety equipment checks, etc. Advised operator to record in black ink vice pencil.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 September 2004 — due date passed with no resolution recorded
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 3 September 2004 No resolution recorded
Missing Certificate of Documentation onboard.
Condition: Unknown
Due 6 September 2004 — due date passed with no resolution recorded
Documentation › Logs/Records › Drug Test Records
Issued 3 September 2004 No resolution recorded
Missing Letter of Compliance from drug consortium. Must prove enrollment and random drug testing in effect for all marine employees.
Condition: Unknown
Due 10 September 2004 — due date passed with no resolution recorded
Electrical › Lighting (service)
Issued 2 July 2003 Resolved
Provide globes for lighting fixtures in forward compartment. LEGACY COMPONENT DESC: Lighting Fixture
Due 2 August 2003
Resolved 21 August 2003
Construction/Loadline › Hull › Bottom Plating
Issued 18 January 2002 Resolved
Crop to good metal and renew wasted hull plating iwo rudder post.
Due 18 January 2002
Resolved 18 January 2002
Resolution: A 12" x 13" insert was installed on port side using backing strips.
Construction/Loadline › Hull › Hull Plating
Issued 18 January 2002 Resolved
Provide plan to clad weld pitting in bow thruster tube.
Due 18 January 2002
Resolved 18 January 2002
Resolution: No plan but pits were welded.
Construction/Loadline › Hull › Hull Plating
Issued 18 January 2002 Resolved
Make port f/o tank safe for entry to inspect bottom plating iwo suspect clad weld which appears on bottom of vessel.
Due 18 January 2002
Resolved 18 January 2002
Resolution: Tank was clean but is too small for entry.
Construction/Loadline › Hull
Issued 18 January 2002 Resolved
Make top of f/o tanks available for inspection.
Due 18 January 2002
Resolved 18 January 2002
Construction/Loadline › Penetrations
Issued 18 January 2002 Resolved
Provide plans to address holes in hawse pipe.
Due 18 January 2002
Resolved 18 January 2002
Resolution: Holes were clad welded.
Construction/Loadline › Hull
Issued 18 January 2002 Resolved
Make all f/o tanks available for inspection.
Due 18 January 2002
Resolved 18 January 2002
Resolution: Tanks not entered due to size of tanks but were examined from deck opening.
Construction/Loadline › Hull › Stringer
Issued 18 January 2002 Resolved
Renew deck framing in owners quarters.
Due 18 January 2002
Resolved 18 January 2002
Construction/Loadline › Hull › Hull Plating
Issued 18 January 2002 Resolved
Provide hull gaugings iwo cement ballast.
Due 18 January 2002
Resolved 18 January 2002
Construction/Loadline › Hull
Issued 18 January 2002 Resolved
Make bilge areas accessible for inspection.
Due 18 January 2002
Resolved 18 January 2002
Construction/Loadline › Hull
Issued 18 January 2002 Resolved
Seal and secure forward hatch.
Due 18 January 2002
Resolved 18 January 2002
Engineering › Bilge Water Management System
Issued 18 January 2002 Resolved
Renew hose for forward bilge pump operatrion. LEGACY COMPONENT DESC: Piping
Due 18 January 2002
Resolved 18 January 2002
Construction/Loadline › Hull › Side Shell
Issued 18 January 2002 Resolved
Crop and renew wasted starboard sideshell iwo masters cabin along tank top.
Due 18 January 2002
Resolved 18 January 2002
Operations/Management › Drills/Instruction › Safety Orientation
Issued 18 January 2002 Resolved
Provide adequate Passenger Safety Orientation brief
Due 29 May 2002
Resolved 29 May 2002
Construction/Loadline › Structures › Deck Plating
Issued 18 January 2002 Resolved
Make proper repairs to sagging forward salon deck.
Condition: Improper/Lack of Maintenance
Due 29 May 2002
Resolved 29 May 2002
Electrical › Electrical Distribution System (service)
Issued 18 January 2002 Resolved
Provide electrical box/cover for exposed components of aft head's pressure system. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Condition: Improper Installation
Due 26 June 2002
Resolved 24 June 2002
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 18 January 2002 Resolved
Make proper repairs to aft sewage vent line.
Condition: Damaged By Earlier Event
Due 29 May 2002
Resolved 29 May 2002
Lifesaving › Lifebuoys
Issued 18 January 2002 Resolved
Renew aft two ring buoys.
Condition: Improper/Lack of Maintenance
Due 29 May 2002
Resolved 29 May 2002
Lifesaving › Lifejacket/PFD (Type II)
Issued 18 January 2002 Resolved
Renew retro-reflective tape on lifejackets as needed LEGACY COMPONENT DESC: Retroreflective Material
Due 26 June 2002
Resolved 24 June 2002
Lifesaving › Buoyant Apparatus
Issued 18 January 2002 Resolved
Make proper repairs to Lifefloat handling lines and minor punctures.
Condition: Improper/Lack of Maintenance
Due 26 June 2002
Resolved 11 July 2002
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 18 January 2002 Resolved
Provide emergency broadcast placard.
Due 29 May 2002
Resolved 29 May 2002
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 18 January 2002 Resolved
Properly maintain training logs.
Due 29 May 2002
Resolved 29 May 2002
Communications › Audible Communications › SPD (Other)
Issued 18 January 2002 Resolved
Provide proper operation of public address system.
Due 29 May 2002
Resolved 29 May 2002
Personnel › Manning/Qualifications
Issued 18 January 2002 Resolved
Assure 50% of crewmembers have proof of current 1st Aid/CPR training. LEGACY COMPONENT DESC: First Aid Certified Personnel
Condition: Unknown
Due 26 June 2002
Resolved 24 June 2002
Fire Fighting › Combustible Materials
Issued 18 January 2002 Resolved
Relocate liquor locker.
Due 29 May 2002
Resolved 29 May 2002
Lifesaving
Issued 5 June 2001 Resolved
provide reflective tape on bouyant apparatus and renew reflective tape on all lifejackets.
Condition: Unknown
Due 5 June 2001
Resolved 6 June 2001
Lifesaving
Issued 5 June 2001 Resolved
provide lifejacket donning placards.
Condition: Unknown
Due 5 June 2001
Resolved 6 June 2001
Fire Fighting
Issued 5 June 2001 Resolved
provide brackets for portable fire extinguishers in machinery space.
Condition: Unknown
Due 5 June 2001
Resolved 6 June 2001
Lifesaving
Issued 25 June 1998 Resolved
REPAIR/RENEW LIFE FLOAT TO INCLUDE LIFE LINES.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Lifesaving
Issued 25 June 1998 Resolved
REMOVE/SECURE GEAR ADRIFT IN ENGINE ROOM, CREW'S QUARTERS AND BOAT DECK. REMOVE DEBRIS FROM ENGINE ROOM BILGES.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Electrical
Issued 25 June 1998 Resolved
RENEW PORT SIDE GENERATOR BREAKER.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Electrical
Issued 25 June 1998 Resolved
REATTACH DANGLING ELECTRICAL CABLES IN ENGINE ROOM PORT SIDE AFT.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Electrical
Issued 29 April 1991 Resolved
PROPERLY WIRE FAN AND P.A. SYSTEM IN PILOTHOUSE.
Condition: Unknown
Due 29 April 1991
Resolved 29 April 1991
Electrical
Issued 2 May 1989 Resolved
COMPLETE REPAIRS TO STARBOARD GENERATOR AND DEMONSTRATE PROPER OPERATION UNDER LOAD.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Electrical
Issued 2 May 1988 Resolved
REMOVE OR PROPERLY INSTALL ELECTRICAL CABLE ON BOAT DECK WHICH RUNS TO MAST.
Condition: Unknown
Due 2 May 1988
Resolved 2 May 1988
Electrical
Issued 2 May 1988 Resolved
PROVIDE AND INSTALL AN ELECTRICAL BLANK FOR THE 110V POWER PANEL IN THE ENGROOM ON FORWARD BULKHEAD.
Condition: Unknown
Due 2 May 1988
Resolved 2 May 1988
Electrical
Issued 2 May 1988 Resolved
PROVIDE AND INSTALL AN ELECTRICAL BLANK FOR THE 220V POWER PANEL IN THE ENG ROOM ON FORWARD BULKHEAD.
Condition: Unknown
Due 2 May 1988
Resolved 2 May 1988
Lifesaving
Issued 14 May 1986 Resolved
REPLACE CLASS "B" EPIRB WITH CLASS "C" EPIRB AS PER 46CFR180.40-1(C). ROUTE IS LIMITED TO RIVERS BETWEEN LAKE HURON CUT BUOYS 1 AND 2 TO DETROIT RIVER LIGHT UNTIL CORRECTED. DEFICIENCY TO BE CORRECTED IN NO CASE LATER THAN 30 JUNE 1986.
Condition: Unknown
Due 14 May 1986
Resolved 14 May 1986
Engineering
Issued 14 May 1986 Resolved
REPLACE LAGGING ON M/E EXHAUST.
Condition: Unknown
Due 14 May 1986
Resolved 14 May 1986
Electrical
Issued 14 May 1986 Resolved
PROVIDE PROPER ELECTRICAL CONNECTIONS AND JUNCTION BOXES IN THE FURNACE, PORT AND STARBOARD RESCUE BOAT WINCHES AND FORWARD CREW COMPARTMENT. 46CFR183.05-50(B)(1)
Condition: Unknown
Due 14 May 1986
Resolved 14 May 1986
Unknown
Issued 14 May 1986 Resolved
REPLACE FLEXIBLE HOSE WITH SUITABLE RIGID PIPE FOR AFT WATER TANK SIGHT TUBE. INSTALL VALVES AT WATER TIGHT BULKHEAD. 46CFR182.40-1, 46CFR182.40-10
Condition: Unknown
Due 14 May 1986
Resolved 14 May 1986

Casualty record · 1

2 November 2006Routine · role: Acknowledged Pollution Source · activity 2813133
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.