Records from 1985 to 2008. Most recent: inspection, 11 January 2008.
Inspection history · 165
11 January 2008
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3128669
12 July 2007
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2992452
6 July 2007
In-Service Inspection · Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2985682
5 July 2007
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2990526
5 June 2007
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2954503
19 April 2007
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2911340
28 March 2007
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2896702
9 February 2007
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2869662
22 May 2006
MTSA Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2658924
23 May 2005
MTSA Verification · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2360148
30 September 2004
Internal Structural Exam · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2207479
24 May 2004
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2076505
21 July 2003
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1852810
4 June 2003
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1809075
13 October 2002
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1694950
30 May 2002
COI Inspection · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1623785
5 November 2001
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1435298
20 July 2001
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1389441
15 June 2001
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1065357
1 May 2001
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 100320
3 April 2001
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1471425
20 October 2000
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 823180
20 October 2000
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1054863
1 September 2000
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 822767
13 August 2000
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 102021
24 July 2000
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1379144
21 June 2000
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 124920
6 June 2000
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1051078
27 April 2000
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1399350
28 January 2000
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1403032
22 December 1999
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 813421
9 December 1999
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 812089
30 November 1999
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 812688
1 October 1999
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 174092
1 October 1999
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1421738
15 September 1999
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1388910
14 July 1999
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1098210
10 June 1999
Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1465485
20 May 1999
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 797873
12 May 1999
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 212447
25 March 1999
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1360782
4 January 1999
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1395081
20 October 1998
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1413431
10 September 1998
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1472917
30 July 1998
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1469197
14 June 1998
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 50870
29 May 1998
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 122245
28 May 1998
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 791843
27 May 1998
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 79880
30 April 1998
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1381225
23 March 1998
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 150096
5 March 1998
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1398851
15 January 1998
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 180550
9 December 1997
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1364472
21 November 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 173006
14 October 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 114846
29 September 1997
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1383675
9 September 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 28733
9 September 1997
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1112471
16 August 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 99524
30 June 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 92272
25 November 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 16858
25 November 1996
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1363857
16 October 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 96741
16 October 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 124940
16 October 1996
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1160528
14 October 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 17306
30 September 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 102172
30 September 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 102598
30 September 1996
Damage Survey · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1398541
19 September 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 78788
18 September 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 101006
10 July 1996
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1088012
30 June 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 50308
8 June 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 123528
29 May 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 117689
29 May 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1363652
25 May 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 231346
25 May 1996
Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1470117
14 April 1996
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1380473
13 April 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 110854
13 April 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 166532
10 April 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 131007
6 April 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 113662
1 April 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 30249
7 February 1996
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1357467
16 January 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 882897
15 November 1995
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1367559
13 November 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 75274
9 November 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 59765
31 August 1995
Damage Survey · Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1428487
29 August 1995
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1360234
23 May 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 107836
16 May 1995
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1358752
29 March 1995
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1371034
27 March 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 178267
9 March 1995
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 862825
15 February 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 121491
14 February 1995
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1154861
20 January 1995
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1380146
8 December 1994
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1425521
7 December 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 51772
5 December 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 187014
4 December 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 9881
1 October 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 155271
11 September 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 10467
11 September 1994
Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1354933
21 July 1994
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1173783
2 July 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 126832
7 June 1994
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1322106
22 April 1994
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1168770
22 April 1994
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1436867
22 February 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1163580
16 February 1994
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1163557
10 February 1994
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1163489
12 January 1994
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1373963
7 October 1993
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1366919
19 July 1993
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1422257
16 July 1993
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 14778
16 July 1993
Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1356355
29 January 1993
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1473582
15 December 1992
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1457074
5 December 1992
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 162011
19 October 1992
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1247804
14 May 1992
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1268650
21 April 1992
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 948607
27 January 1992
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 955080
22 November 1991
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 936743
21 October 1991
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1249238
19 August 1991
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 942579
15 August 1991
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1248861
23 July 1991
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 998926
26 April 1991
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 930871
5 April 1991
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 920927
3 April 1991
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 916201
6 February 1991
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 901341
5 December 1990
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 912872
30 September 1990
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 167187
25 September 1990
Re-Inspection · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1217756
7 August 1990
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 901352
16 July 1990
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 904849
11 May 1990
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 923672
12 April 1990
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 925032
29 March 1990
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1291272
13 December 1989
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 927407
7 December 1989
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 917953
31 October 1989
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 997125
26 September 1989
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 998904
2 March 1989
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1197078
20 January 1989
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1200961
11 January 1989
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1196461
9 December 1988
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 899190
7 October 1988
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1198090
29 July 1988
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1341767
11 December 1987
Hull Examination · COI Inspection · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1326845
15 May 1987
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1015704
1 May 1987
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1321549
16 December 1986
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1325514
19 November 1986
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1325517
14 August 1986
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 998780
25 June 1986
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1304344
9 June 1986
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1310877
6 March 1986
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 986698
31 October 1985
Credit Drydock
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1302712
26 April 1985
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1290856
Construction/Loadline › Hull › Bottom Plating
Issued 11 January 2008
Resolved
Conduct thorough cleaning of all bilges/below deck spaces and make vessel available for a complete internal structural examination.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2009
Resolved 7 August 2009
Resolution: Vessel sold for scrap.
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 29 March 2007
Resolved
Prove operation of vehicle deck sprinkler system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2007
Resolution: Test satisfactory.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 29 March 2007
Resolved
Calibrate magnetic compass.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2007
Engineering › Steering Gear System › Hydraulic Hose
Issued 29 March 2007
Resolved
Replace hoses on #1 and #2 end steering system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2007
Resolution: Hoses renewed
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 29 March 2007
Resolved
Provide approved fire control plan onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2007
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 29 March 2007
Resolved
Make tight cast iron seachests on port and starboard side of #2 end engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2007
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 29 March 2007
Resolved
Load test or replace TEP batteries.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2007
Resolution: load tested satisfactory
Lifesaving › Rescue Boat › Capacity
Issued 22 May 2006
Resolved
Vessel required to carry approved rescue boat on each side of vessel as required by 46 CFR 199.202.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2007
Resolved 29 March 2007
Lifesaving › Launching Appliances › Falls
Issued 22 May 2006
Resolved
Lifeboat/Rescue Boat falls required to renewed after 22 JUN 06 as required by 46 CFR 199.190(j)
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2007
Resolved 29 March 2007
Lifesaving › Launching Appliances › Gate/Opening for Manual Launch
Issued 22 May 2006
Resolved
Vessel to install functional Marine Evacuation Systems in each corner of vessel as required by 46 CFR 199.145
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2007
Resolved 29 March 2007
Operations/Management › Drills/Instruction › Not Conducted
Issued 22 May 2006
Resolved
Vessel required to perform fire, abandoned ship, and man overboard drills
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2007
Resolved 8 May 2007
Resolution: QTRLY completed at Eagle Harbor.
Fire Fighting › Ventilation Systems › Ducts
Issued 22 May 2006
Resolved
Free ventilation dampers on numerous location on car deck
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 22 May 2006
Resolution: Shipyard personnel freed all dampers on car deck to the satisfaction of attending marine inspector.
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 23 May 2005
Resolved
Demonstrate all boiler safeties to the satisfaction of the Coast Guard prior to placing vessel into service.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2007
Resolved 29 March 2007
Engineering › Steam Boiler (auxiliary/waste heat) › Gauge Glass
Issued 23 May 2005
Resolved
Calibrate steam pressure gage for boiler prior to placing vessel into service.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2007
Resolved 29 March 2007
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 23 May 2005
Resolved
Demonstrate proper operation of oxygen alarm and sensor in co2 room prior to placing vessel into service.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2007
Resolved 26 April 2007
Lifesaving › Launching Appliances › Release Mechanism
Issued 24 May 2004
Resolved
Provide survival craft with a total capacity for 391 persons in accordance with 46 CFR 199.630(f) and (g), prior to operating vessel in accordance with its issued Certificate of Inspection.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 January 2007
Resolved 29 March 2007
Lifesaving › Lifejacket/PFD (General)
Issued 4 June 2003
Resolved
Vessel missing 647 adult PFDs and 28 child PFDs. Provide missing PFDs prior to carrying total passengers endorsed on vsl's COI. LEGACY COMPONENT DESC: Quantity
Action required: 705 - Other - as specified
Resolved 21 July 2003
Stability › Watertight Integrity
Issued 4 June 2003
Resolved
Fix inoperative watertight door indication light in way of #2 end watertight door. LEGACY COMPONENT DESC: #2 end watertight door light indicator
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 21 July 2003
Operations/Management › Drills/Instruction › Abandon Ship
Issued 4 June 2003
Resolved
Conduct fire and abandon ship drills (including man overboard) prior carriage of passnegers.
Action required: 705 - Other - as specified
Resolved 21 July 2003
Electrical › Lighting (emergency)
Issued 30 May 2002
Resolved
Emergency Lighting in passenger accomodations on the number 2 end does not work. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 June 2002
Resolved 6 June 2002
Resolution: Repaired to the satisfaction of the attending Coast Guard marine inspector
Lifesaving › Inflatable Liferafts
Issued 30 May 2002
Resolved
Hydrostatic releases out of date, replace. LEGACY COMPONENT DESC: Hydrostatic Release Unit
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2002
Resolved 6 June 2002
Resolution: Repaired to the satisfaction of the attending Coast Guard marine inspector
Lifesaving › Inflatable Liferafts
Issued 30 May 2002
Resolved
Liferaft beyond service date.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2002
Resolved 6 June 2002
Resolution: Repaired to the satisfaction of the attending Coast Guard marine inspector
Lifesaving › Inflatable Liferafts
Issued 30 May 2002
Resolved
Due to modification work being conducted on vessel the liferaft was not installed on port side towards the #2 end. LEGACY COMPONENT DESC: Carriage Requirement
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2002
Resolved 6 June 2002
Resolution: Repaired to the satisfaction of the attending Coast Guard marine inspector
Engineering › Steam Boiler (auxiliary/waste heat)
Issued 30 May 2002
Resolved
Plastic plug on fuel filter of boiler, replace with metal plug. LEGACY COMPONENT DESC: Fuel Oil Burner
Action required: 705 - Other - as specified
Due 18 June 2002
Resolved 6 June 2002
Resolution: Repaired to the satisfaction of the attending Coast Guard marine inspector
Electrical › Mast
Issued 30 May 2002
Resolved
Number 2 end bottom mast light does not work work.
Action required: 705 - Other - as specified
Due 18 June 2002
Resolved 6 June 2002
Resolution: Repaired to the satisfaction of the attending Coast Guard marine inspector
Accommodation/Occupational Safety
Issued 27 April 2000
Resolved
INSTALL ADEQUATE SAFETY NETTING ACROSS BOTH RESCUE BOAT BOARDING STATION OPENINGS.
Condition: Unknown
Due 27 April 2000
Resolved 27 April 2000
Navigation
Issued 27 April 2000
Resolved
ELIMINATE FALSE "STEERING FAILURE ALARM" INDICATION RECIEVED WHEN #2 END RUDDER IS PLACED IN THE HARD RIGHT POSITION.
Condition: Unknown
Due 27 April 2000
Resolved 27 April 2000
Construction/Loadline
Issued 1 October 1999
Resolved
Vessel seachest vent have PVC piping attached. PVC piping needs to be replaced with ferrous metal piping and fitting.
Condition: Unknown
Due 1 October 1999
Resolved 1 October 1999
Lifesaving
Issued 1 October 1999
Resolved
Rescue boat Jacobs ladder for embarking rescue boat crew, needs to evaluated for crew safety upon retrieval of crew. Current arrangement is unsafe and hard to retrieve crewmembers.
Condition: Unknown
Due 1 October 1999
Resolved 1 October 1999
Fire Fighting
Issued 20 May 1999
Resolved
CONDUCT 12 YEAR HYDROSTATIC TESTS ON ALL FIXED CO2 BOTTLES.
Condition: Unknown
Due 20 May 1999
Resolved 20 May 1999
Construction/Loadline
Issued 5 March 1998
Resolved
REPAIR FRACTURED FRAME IN NO.2 SHAFT ALLEY AT BASE OF UPPER LADDER, OUTBOARD SIDE OF LADDER PLATFORM.
Condition: Unknown
Due 5 March 1998
Resolved 5 March 1998
Lifesaving
Issued 5 March 1998
Resolved
PROVIDE NEW STATION BILLS THAT REFLECT VESSEL MANNING IN ACCORDANCE WITH CURRENT COI.
Condition: Unknown
Due 5 March 1998
Resolved 5 March 1998
Lifesaving
Issued 9 December 1997
Resolved
REPAIR LIMIT SWITCH FOR NO. 1 RESCUE BOAT.
Condition: Unknown
Due 10 December 1997
Resolved 12 December 1997
Documentation
Issued 9 December 1997
Resolved
POST ORIGINAL STABILITY LETTER DATED 25 JAN 94 IN PILOT HOUSE.
Condition: Unknown
Due 9 December 1997
Resolved 9 December 1997
Lifesaving
Issued 9 December 1997
Resolved
SECURE (3) REFRIGERATORS AND RACK FOR OILY PADS LOCATED AT NO. 1 END ENGINEROOM PORTSIDE IN THE AREA OF THE UPPER AND LOWER LEVEL.
Condition: Unknown
Due 9 December 1997
Resolved 9 December 1997
Lifesaving
Issued 9 December 1997
Resolved
REMOVE PADLOCKS AT LIFERAFT AND RESCUE BOAT STATIONS OR PROVIDE KEYBOX FOR THOSE STATIONS.
Condition: Unknown
Due 9 December 1997
Resolved 9 December 1997
Electrical
Issued 29 September 1997
Resolved
Properly wire overhead lighting in No. 2 end engine room.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Navigation
Issued 9 September 1997
Resolved
PROIR TO RETURNING VESSEL TO SERVICE, REPAIR AND TEST NO 1 STEERING GEAR SYSTEM TO THE SATISFACTION OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 18 September 1997
Resolved 18 September 1997
Construction/Loadline
Issued 30 September 1996
Resolved
9 FT OF WATER/OIL WAS FOUND IN #2 STEERING GEAR ROOM. THE COMPARTMENT WAS PUMPED OUT AND INSPECTION COMPLETED ON RIVET LINE. THE ENTIRE COMPARTMENT WAS TO BE CLEANED OUT AND DETAINED INTERNAL INSPECTION IS TO BE COMPLETED.
Condition: Unknown
Due 9 October 1996
Resolved 9 October 1996
Construction/Loadline
Issued 30 September 1996
Resolved
VALVE HANDLES ON BOTH BILGE MANIFOLDS WERE MISSING.
Condition: Unknown
Due 30 September 1996
Resolved 30 September 1996
Navigation
Issued 25 May 1996
Resolved
DURING TRANSFER OF PASSENGERS FERRY PULLED AWAY FROM THE DOCK. PROVIDE TO MSO PUGET SOUND ROSS HILL DATA READ OUT THAT REFLECTS THE 25 MAY 96 DOCKINGAT LOPEZ ISLAND AT 1634.
Condition: Unknown
Due 29 May 1996
Resolved 30 May 1996
Engineering
Issued 14 April 1996
Resolved
PROVIDE SECURITY BOX AROUND FIRE DAMPENER PULL STATIONS TO SCR ROOMS
Condition: Unknown
Due 14 April 1996
Resolved 14 April 1996
Engineering
Issued 14 April 1996
Resolved
PROVIDE OPERATIONAL DIAGNASTICS OF BOTH INSTALLED DC BOARDS.
Condition: Unknown
Due 14 April 1996
Resolved 14 April 1996
Engineering
Issued 14 April 1996
Resolved
PROVIDE TROUBLESHOOTING INFORMATION AS TO CAUSE OF FAILURE OF THE D/C BOARDFROM TWO WEEKS AGO.
Condition: Unknown
Due 14 April 1996
Resolved 14 April 1996
Engineering
Issued 7 February 1996
Resolved
IN ACCORDANCE WITH 46 CFR 61.40-1, PROVIDE DESIGN VERIFICATION AND PERIODICSAFETY TEST PROCEDURE DOCUMENTS APPROVED BY THE COAST GUARD FOR THE VESSEL'S VITAL SYSTEMS AUTOMATION. FURTHERMORE, IN THE PRESENCE OF A COASTGUARD MARINE INSPECTOR, COMPLETE A SATISFACTORY TEST OF THE APPROVED TEST
Condition: Unknown
Due 7 February 1996
Resolved 7 February 1996
Engineering
Issued 7 February 1996
Resolved
PROCEDURES.
Condition: Unknown
Due 7 February 1996
Resolved 7 February 1996
Fire Fighting
Issued 15 November 1995
Resolved
INSTALL SWITCH OUTSIDE THE GALLEY WHICH WILL SECURE THE GAYLORD AND ENERGIZE THE SOAP SYSTEM.
Condition: Unknown
Due 15 November 1995
Resolved 15 November 1995
Engineering
Issued 31 August 1995
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, SHOW CAUSE OF 23MAY95 PROPULSION FAILURE AND DEMONSTRATE THE ACCEPTABLE REPAIRS HAVE BEEN MADE.
Condition: Unknown
Due 8 September 1995
Resolved 8 September 1995
Construction/Loadline
Issued 31 August 1995
Resolved
REPLACE AND/OR REPAIR HULL PLATE, RUB RAIL, MAIN DECK PLATE, BOTTOM PLATE, BRACKETS, STIFFENERS, GUSSETS, AND ANY BROKEN WELDS ASSOCIATED WITH IMPACT DAMAGE IN WAY OF STEERING GEAR ROOM, NO. 1 END, PORT STBD AND BULL NOSE.
Condition: Unknown
Due 8 September 1995
Resolved 8 September 1995
Accommodation/Occupational Safety
Issued 14 February 1995
Resolved
Post valid elevator permit in elevator.
Condition: Unknown
Due 21 February 1995
Resolved 1 March 1995
Lifesaving
Issued 14 February 1995
Resolved
Provide 20 additional adult PFDs and one child PFD.
Condition: Unknown
Due 14 February 1995
Resolved 21 February 1995
Lifesaving
Issued 14 February 1995
Resolved
Make perminent repairs to limit switch on number 2 rescue boat.
Condition: Unknown
Due 14 February 1995
Resolved 21 February 1995
Accommodation/Occupational Safety
Issued 14 February 1995
Resolved
Clean Galley vent hood.
Condition: Unknown
Due 21 February 1995
Resolved 1 March 1995
Accommodation/Occupational Safety
Issued 14 February 1995
Resolved
clean refrigeration machinery & surfaces on top of stand-up refrigators in galley.
Condition: Unknown
Due 21 February 1995
Resolved 1 March 1995
Accommodation/Occupational Safety
Issued 8 December 1994
Resolved
BROKEN WINDOW IN DOOR TO PASSENGER CABIN END #2 ENTRY 4.
Condition: Unknown
Due 8 December 1994
Resolved 8 December 1994
Construction/Loadline
Issued 11 September 1994
Resolved
MAKE PERMANENT REPAIRS TO BUCKLED TRANSVERSE FLOOR FRAMES 8-22, #1 END ENGINE ROOM, STARBOARD SIDE, JUST OUTBOARD OF FIRST LONGITUDINAL GIRDER._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1994
Resolved 11 September 1994
Construction/Loadline
Issued 11 September 1994
Resolved
MAKE PERMANENT REPAIRS TO BOTTOM PLATE WHERE INSET, #1 ENGINEROOM, PORT SIDE BETWEEN FRAMES 9-10 AND 11-12, FIRST FRAME BAYS OUTBOARD OF CVK._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1994
Resolved 11 September 1994
Fire Fighting
Issued 22 April 1994
Resolved
40 PSI SALT WATER REDUCING STATION IS NO LONGER UTILIZED AS VESSEL SANITERYSYSTEM HAS BEEN CONVERTED TO FRESH WATER. REMOVE REDUCER AND BLANK FLANGE_x001C_ TO PREVENT OPERATION OF CAR DECK SPRINKLER SYSTEM AT 40 PSI INSTEAD OF AT_x001C_ DESIGN FIREMAIN PRESSURE OF 120 PSI.
Condition: Unknown
Due 22 April 1994
Resolved 22 April 1994
Lifesaving
Issued 22 April 1994
Resolved
GENERAL ALARM INOPERABLE AT EMERGENCY GENERATOR ROOM AND FIRE STATION #9.
Condition: Unknown
Due 22 April 1994
Resolved 29 April 1994
Construction/Loadline
Issued 22 April 1994
Resolved
ONE EIGTH INCH DIAMETER HOLE IN DECK ABOVE AFT END OF NO. 1 MDE. CAUSE_x001C_ DETERMINED TO BE FROM DEICING SALT USED IN FREEZING WEATHER WHICH WAS STOWED UNDER STAIRTOWER ON CAR DECK.
Condition: Unknown
Due 22 April 1994
Resolved 22 April 1994
Engineering
Issued 7 October 1993
Resolved
Install flame impingement bowl on Racor fuel filter for #2 main engine.
Condition: Unknown
Due 7 October 1993
Resolved 7 October 1993
Construction/Loadline
Issued 16 July 1993
Resolved
MAKE PERM REPAIRS IN WAY OF OUTBOARD FR 34 TO 36 #2 END. ALL REPAIRS TO BE_x001C_COMPLETED AT NEXT SCHEDULED DDX BUT NO LATER THAN 31OCT1993.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Construction/Loadline
Issued 15 December 1992
Resolved
EVALUATE AND MAKE PROPOSAL FOR REPAIRS TO DEEP FRAMES 54 ON THE #1 & 2 ENDSTO THE [name withheld] 8 JAN 93.
Condition: Unknown
Due 15 December 1992
Resolved 15 December 1992
Electrical
Issued 15 December 1992
Resolved
MAKE NECESSARY REPAIRS TO CORRECT OUTAGE OF THE FOLLOWING "E" LIGHTING FIXTURES: #1 END PASSENGER AREA, WOMEN TOILET & PORT OUTBOARD CAR DECK, REPAIRS TO BE COMPLETED NLT 23 DEC 92 AND TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 15 December 1992
Resolved 15 December 1992
Lifesaving
Issued 21 April 1992
Resolved
REPLACE PLACARD TO NUMBER 4 LIFERAFT STATION.
Condition: Unknown
Due 21 April 1992
Resolved 21 April 1992
Lifesaving
Issued 21 April 1992
Resolved
REPLACE PLACARD TO NUMBER TWO LIFERAFT STATION.
Condition: Unknown
Due 21 April 1992
Resolved 21 April 1992
Electrical
Issued 21 October 1991
Resolved
REPAIR "E" LIGHTING IN MENS ROOM, #2 ENGINE ROOM, GALLEY AND PASSENGER AREANEAR LOCKER # 7.
Condition: Unknown
Due 21 October 1991
Resolved 21 October 1991
Electrical
Issued 21 October 1991
Resolved
REPAIR LIGHTS OVER RUDDER ANGLE INDICATOR IN BOTH STEERING GEAR ROOMS.
Condition: Unknown
Due 21 October 1991
Resolved 21 October 1991
Fire Fighting
Issued 21 October 1991
Resolved
PROVE ELEVATOR DOORS ARE PROPERLY INSULATED.
Condition: Unknown
Due 21 November 1991
Resolved 9 November 1991
Fire Fighting
Issued 21 October 1991
Resolved
REPAIR,REPLACE OR REMOVE THE COOKSON ROLLING FIRE SCREEN DOOR BETWEEN GALLEY AND PASSENGER AREA. IF ROLLING SCREEN DOOR IS REMOVED THE NEW BULKHEAD INSERT MUST BE INSULATED TO THE SAME VALUE AS THE ORIGINAL BULKHEAD.
Condition: Unknown
Due 21 October 1991
Resolved 21 October 1991
Construction/Loadline
Issued 21 October 1991
Resolved
REPAINT DRAFT MARKS # AT 1 END.
Condition: Unknown
Due 21 October 1991
Resolved 21 October 1991
Documentation
Issued 21 October 1991
Resolved
PROVE VESSEL HAS ADEQUATE STABILITY.
Condition: Unknown
Due 21 October 1991
Resolved 21 October 1991
Accommodation/Occupational Safety
Issued 21 October 1991
Resolved
REMOVE TIE WRAPS FROM GUARD RAIL MESH INSERTS THROUGHOUT THE VESSEL AND MAKE PERMANANT REPAIRS TO SAME.
Condition: Unknown
Due 21 October 1991
Resolved 21 October 1991
Fire Fighting
Issued 21 October 1991
Resolved
INSTALL BREAK GLASS BOX FOR GALLEY KEY AT GALLEY DOOR.
Condition: Unknown
Due 21 October 1991
Resolved 21 October 1991
Fire Fighting
Issued 23 July 1991
Resolved
CONDUCT SAT. HYDRO TEST OF OUT OF DATE EXTINGUISHERS OR REPLACE WITH PROPEREXTINGUISHERS.
Condition: Unknown
Due 23 July 1991
Resolved 23 July 1991
Engineering
Issued 23 July 1991
Resolved
CONDUCT AN AUXILIARY BOILER MOUNTINGS REMOVED INSPECTION IN THE PRESENCE OFA USCG MARINE INSPECTOR.
Condition: Unknown
Due 23 July 1991
Resolved 23 July 1991
Fire Fighting
Issued 23 July 1991
Resolved
PROVE PROPER OPERATION OF ROLLING FIRE SCREEN DOOR AT SERVICE WINDOW IN GALLEY.
Condition: Unknown
Due 23 July 1991
Resolved 23 July 1991
Documentation
Issued 3 April 1991
Resolved
ELEVATOR INSPECTION CERTIFICATE OUTDATED AS OF JAN 91._x001C_
Condition: Unknown
Due 3 April 1991
Resolved 3 April 1991
Electrical
Issued 5 December 1990
Resolved
PROPERLY DEAD END ELECTRICAL CABLE IN GALLEY.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Fire Fighting
Issued 5 December 1990
Resolved
SERVICE FIXED FIRE EXTINGUISHING SYSTEM IN GALLEY.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Fire Fighting
Issued 5 December 1990
Resolved
POST INSTRUCTION CARD FOR FIXED FIRE EXTINGUISHING SYSTEM IN GALLEY.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Fire Fighting
Issued 5 December 1990
Resolved
REPAIR FIRE SCREEN DOOR #13 IN GALLEY.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Fire Fighting
Issued 5 December 1990
Resolved
PROPERLY LABEL PAINT LOCKER FIXED SYSTEM DOORS.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Fire Fighting
Issued 5 December 1990
Resolved
SHOW ACCOMODATION SPACE VENTILATION FIRE DAMPERS CAN BE CLOSED IN FIRE.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Lifesaving
Issued 7 August 1990
Resolved
PROVIDE LIFERAFT LAUNCHING INSTRUCTIONS AT #5 LIFERAFT.
Condition: Unknown
Due 7 August 1990
Resolved 7 August 1990
Fire Fighting
Issued 7 August 1990
Resolved
PROVE PROPER OPERATION OF FIRE SCREEN DOOR NO. 16.
Condition: Unknown
Due 7 August 1990
Resolved 7 August 1990
Fire Fighting
Issued 7 August 1990
Resolved
PROPERLY LABEL FIRE AXE NEAR FIRE STATION 17.
Condition: Unknown
Due 7 August 1990
Resolved 7 August 1990
Lifesaving
Issued 7 August 1990
Resolved
PROVIDE LIFE JACKET INSTRUCTIONS FOR KAPOK STYLE LIFE JACKETS AT NO. 1 END CAR DECK LIFE JACKET LOCKER.
Condition: Unknown
Due 7 August 1990
Resolved 7 August 1990
Engineering
Issued 29 March 1990
Resolved
OPERATE AND PROVE SATISFACTORY, VSL OILY WATER SEPERATOR OPERATION.
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990
Accommodation/Occupational Safety
Issued 7 December 1989
Resolved
PROVIDE VALID CERIFICATE OF INSPECTION FOR ELEVATOR OPERATION.
Condition: Unknown
Due 7 December 1989
Resolved 7 December 1989
Engineering
Issued 7 December 1989
Resolved
SATISFACTORILY TEST AND LOG HIGH JACKET WATER ALARM FOR #2 MAIN DIESEL ENGINE.
Condition: Unknown
Due 7 December 1989
Resolved 7 December 1989
Navigation
Issued 7 December 1989
Resolved
PROVIDE VALID DEVIATION TABLE.
Condition: Unknown
Due 7 December 1989
Resolved 7 December 1989
Lifesaving
Issued 7 December 1989
Resolved
RELOCATE AND PROVE PROPER OPERATION OF FORE AND AFT BLOCKS FOR PAINTER TENSION LINES ON BOTH RESCUE BOATS.
Condition: Unknown
Due 7 December 1989
Resolved 7 December 1989
Electrical
Issued 26 September 1989
Resolved
REPAIR THROTTLE DIMMER PANEL SWITCH AT NO.2 END.
Condition: Unknown
Due 26 September 1989
Resolved 26 September 1989
Electrical
Issued 26 September 1989
Resolved
PROVE SOUND POWERED PHONES RING FROM ALL STATIONS.
Condition: Unknown
Due 26 September 1989
Resolved 26 September 1989
Electrical
Issued 26 September 1989
Resolved
PROVE PROPER OPERATION OF NO.2 END SEARCH LIGHT.
Condition: Unknown
Due 26 September 1989
Resolved 26 September 1989
Electrical
Issued 26 September 1989
Resolved
REPAIR LIGHT IN GYRO REPEATER ON NO.2 END.
Condition: Unknown
Due 26 September 1989
Resolved 26 September 1989
Electrical
Issued 26 September 1989
Resolved
PROVE PROPER OPERATION OF WHISTLE BUTTON ON CENTER CONSOLE ON NO.2 END.
Condition: Unknown
Due 26 September 1989
Resolved 26 September 1989
Lifesaving
Issued 26 September 1989
Resolved
REPAIR BROKEN BOAT CHOCK AND GRIPE TIE DOWN FOR NO.1 RESCUE BOAT.
Condition: Unknown
Due 26 September 1989
Resolved 26 September 1989
Lifesaving
Issued 26 September 1989
Resolved
PROVIDE LAUNCHING INSTRUCTIONS FOR NO.5 LIFERAFT.
Condition: Unknown
Due 26 September 1989
Resolved 26 September 1989
Fire Fighting
Issued 26 September 1989
Resolved
PROVIDE DIELECTRIC GLOVES AND POST EQUIPMENT LIST ON EMERGENCY GEAR LOCKER.
Condition: Unknown
Due 26 September 1989
Resolved 26 September 1989
Electrical
Issued 26 September 1989
Resolved
REPAIR INDICATOR LIGHT FOR FIRE DOOR TO ENGINE CONTROL ROOM. INDICATOR LIGHT AT NO.1 END.
Condition: Unknown
Due 26 September 1989
Resolved 26 September 1989
Electrical
Issued 2 March 1989
Resolved
SUBMIT "AS INSTALLED" PLANS FOR APPROVAL OF ELECTRICAL MODIFICATIONS REGAURDING UPS REMOVAL. SPECIFICALLY DWG 3071-090-02, REV I WITH CHANGES ASNOTED DURING 17FEB89 AND 02MAR89 EXAMINATIONS.
Condition: Unknown
Due 2 March 1989
Resolved 2 March 1989
Engineering
Issued 9 December 1988
Resolved
REPAIR OILY WATER SEPARATOR. RETAIN ALL OILY WASTES IN DIRTY OIL TANK FOR DISCHARGE TO SHORE FACILITY UNTIL O.W.S. REPAIRED.
Condition: Unknown
Due 9 December 1988
Resolved 9 December 1988
Fire Fighting
Issued 9 December 1988
Resolved
REPLACE BOTH 60 SEC. TIME DELAYS WITH 20 SEC. TIME DELAYS.
Condition: Unknown
Due 9 December 1988
Resolved 9 December 1988
Lifesaving
Issued 9 December 1988
Resolved
INSTALL LIMIT SWITCHES ON BOTH ELECTRIC BOAT WINCHES IAW 46 CFR 111.95.
Condition: Unknown
Due 9 December 1988
Resolved 9 December 1988
Accommodation/Occupational Safety
Issued 9 December 1988
Resolved
INSTALL PROPER RELIEF VALVE IN POTABLE WATER HEAD TANK.
Condition: Unknown
Due 9 December 1988
Resolved 9 December 1988
Fire Fighting
Issued 11 December 1987
Resolved
INSTALL LATCHES ON FIRE SCREEN DOORS LOCATE AT TOP OF LADDERS FROM AUTO DECK TO PASSENGER DECK (4) AND TWO GALLEY FIRE SCREEN DOORS NOT PRESENTLY HAVING LATCHES INSTALLED, AS REQUIRED BY REGULATION 46CFR 72.05(B)(3).
Condition: Unknown
Due 11 December 1987
Resolved 11 December 1987
Fire Fighting
Issued 16 December 1986
Resolved
PROPERLY TIE IN ALL FIXED CO2 BOTTLES TO CABLE PULL, TIGHTEN LOOSE CONNECTORS, AND REPAIR FLEXIBLE LOOP ON LAST BOTTLE IN BANK.
Condition: Unknown
Due 16 December 1986
Resolved 16 December 1986
Fire Fighting
Issued 16 December 1986
Resolved
REPLACE HOSE ASSEMBLIES ON BOTH ENGINE ROOM SEMI PORTABLE EXTINGUISHING SYSTEMS
Condition: Unknown
Due 16 December 1986
Resolved 16 December 1986
Fire Fighting
Issued 16 December 1986
Resolved
REPLACE JURY RIGGED PIPING ON SEMI PORTABLE EXTINGUISHER IN #1 END
Condition: Unknown
Due 16 December 1986
Resolved 16 December 1986
Electrical
Issued 16 December 1986
Resolved
PROPERLY DEADEND CABLE IN OVERHEAD RUN LOWER LEVEL OF #1 END ENGINEROOM
Condition: Unknown
Due 16 December 1986
Resolved 16 December 1986
Electrical
Issued 16 December 1986
Resolved
REPLACE ALL PLASTIC WIRETIES WITH REQUIRED METAL BANDS IN BOTH ENGINE ROOMS
Condition: Unknown
Due 16 December 1986
Resolved 16 December 1986
Fire Fighting
Issued 16 December 1986
Resolved
REPLACE FIXED CO2 EXTINGUISHER ON GENERATOR WHICH IS OUT OF HYDRO
Condition: Unknown
Due 16 December 1986
Resolved 16 December 1986
Fire Fighting
Issued 16 December 1986
Resolved
REWEIGH FIXED CO2 FOR PAINT LOCKER, AND HAND PORTABLE AT CONTROL STATION
Condition: Unknown
Due 16 December 1986
Resolved 16 December 1986
Fire Fighting
Issued 16 December 1986
Resolved
REPLACE FIXED CO2 BEHIND CONTROL PANEL WITH REQUIRED 200# OF CO2.
Condition: Unknown
Due 16 December 1986
Resolved 16 December 1986
Fire Fighting
Issued 16 December 1986
Resolved
SUPPLY 10 CUBIC FT. OF SAND IN AUX BOILER SPACE.
Condition: Unknown
Due 16 December 1986
Resolved 16 December 1986
Fire Fighting
Issued 16 December 1986
Resolved
REMOUNT PORTABLE EXTINGUISHER AT STATION 34
Condition: Unknown
Due 16 December 1986
Resolved 16 December 1986
Accommodation/Occupational Safety
Issued 16 December 1986
Resolved
SUPPLY REACH ROD FOR VALVE IN PLASTIC PIPE MSD LINE #1 END
Condition: Unknown
Due 16 December 1986
Resolved 16 December 1986
Accommodation/Occupational Safety
Issued 16 December 1986
Resolved
PROVIDE WORKING PRESSURE TEST OF MSD LINE MENTIONED IN ITEM 9 AND DEMONSTRATE BY NON DESTRUCTIVE TEST THE WATER TIGHT INTEGRITY OF THE SPOOL PIECE BULKHEAD PENETRATION.
Condition: Unknown
Due 16 December 1986
Resolved 16 December 1986
Electrical
Issued 16 December 1986
Resolved
REMOUNT THE BATTERY/KNIFE SWITCH ARRANGEMENT FOR THE GASOLINE OPERATED GENERATOR TO PREVENT CHANCE OF VENTING BATTERY GAS BEING IGNITED
Condition: Unknown
Due 16 December 1986
Resolved 16 December 1986
Fire Fighting
Issued 19 November 1986
Resolved
REPLACE HOSE ASSEMBLY ON SEMI PORTABLE EXTINGUISHER IN #1 END.
Condition: Unknown
Due 19 November 1986
Resolved 19 November 1986
Unknown
Issued 6 March 1986
Resolved
HOLD FIRE AND BOAT DRILLS AS REQUIRED BY 46 CFR 78.17-50(A).
Condition: Unknown
Due 6 March 1986
Resolved 6 March 1986
Fire Fighting
Issued 26 April 1985
Resolved
CONDUCT FIRE DRILL. THIS DEFICIENCY WAS TO HAVE BEEN CORRECTED BY 6 MAY 1985.
Condition: Unknown
Due 26 April 1985
Resolved 26 April 1985
Engineering
Issued 26 April 1985
Resolved
INSTALL A U. S. COAST GUARD APPROVED SAFETY VALVE ON THE AUXILIARY BOILER THAT WILL DISCHARGE MORE STEAM THAN THE MAXIMUM STEAM OUTPUT OF THE AUXILIARY BOILER AS PER 46 CFR 53.05-1 AND ASME HG-400-1. THIS DEFICIENCY WAS TO HAVE BEEN CORRECTED BY 3 MAY 1985.
Condition: Unknown
Due 26 April 1985
Resolved 26 April 1985
Lifesaving
Issued 26 April 1985
Resolved
CONDUCT BOAT DRILL. THIS DEFICIENCY WAS TO HAVE BEEN CORRECTED BY 6 MAY 1985.
Condition: Unknown
Due 26 April 1985
Resolved 26 April 1985