Records from 1984 to 1992. Most recent: inspection, 26 June 1992.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 10
26 June 1992
Administrative
Administrative · Commandant (CG-INV-3) · Activity 957709
16 August 1987
Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1025165
16 August 1987
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1029576
15 September 1986
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1309391
14 May 1986
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1302920
9 May 1986
Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1302917
27 February 1986
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 987526
9 May 1985
Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 977851
3 April 1985
Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1285646
1 May 1984
COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1295673
Construction/Loadline
Issued 16 August 1987
Resolved
RENEW THE ROTTED FRAME IN WAY OF THE 2ND FLOOR FORWARD OF THE STERN FRAME STARBOARD SIDE.
Condition: Unknown
Due 1 May 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 16 August 1987
Resolved
REBUILD AND RELINE BATTERY BOX.
Condition: Unknown
Due 1 May 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 16 August 1987
Resolved
PROVIDE SUPPORT FOR ALL ELECTRICAL WIRING.
Condition: Unknown
Due 1 May 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 16 August 1987
Resolved
RENEW ROTTED FRAME STARBOARD SIDE FORWARD OF THE AFTER BULKHEAD OF THE PASSENGER CABIN.
Condition: Unknown
Due 1 May 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 16 August 1987
Resolved
RENEW DECK BEAMS 1, 2, 3, 4 AND 5 AFT OF STEM.
Condition: Unknown
Due 1 May 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 16 August 1987
Resolved
RENEW FRAME AFT OF THE 3RD FLOOR FORWARD OF STERN STARBOARD SIDE.
Condition: Unknown
Due 1 May 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 16 August 1987
Resolved
SISTER OR RENEW THE LONGITUDINAL STIFFNER STARBOARD SIDE IN WAY OF THE KEELBETWEEN 1ST AND 2ND FLOOR FORWARD OF THE STERN.
Condition: Unknown
Due 1 May 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 16 August 1987
Resolved
REMOVE THE PORT SIDE WAIST IN THE INTERIOR OF THE FORWARD COMPARTMENT SO ASTO MAKE AVAILABLE FOR INSPECTION THE INTERNAL STRUCTURAL MEMBERS IN THE AREA.
Condition: Unknown
Due 1 May 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 16 August 1987
Resolved
RENEW #2 FLOOR AFT OF STEM.
Condition: Unknown
Due 1 May 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 16 August 1987
Resolved
RENEW ALL FASTNERS IN WAY OF CHINE AFT OF #4 FRAME.
Condition: Unknown
Due 1 May 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 16 August 1987
Resolved
RENEW FRAMES #6, 7, 15 AND 17 STARBOARD SIDE AFT OF STEM.
Condition: Unknown
Due 1 May 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 16 August 1987
Resolved
RENEW DECK BEAM IN WAY OF THE AFTER BULKHEAD OF THE FORWARD (#1) COMPARTMENT.
Condition: Unknown
Due 1 May 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 16 August 1987
Resolved
RENEW THE ROTTED FLOOR IN WAY OF THE AFTER BULKHEAD OF THE FORWARD COMPARTMENT.
Condition: Unknown
Due 1 May 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 16 August 1987
Resolved
RENEW THE THROUGH BOLTS FOR ALL FRAMES IN WAY OF THE CHINE AFT OF THE FORWARD BULKHEAD OF THE ENGINE ROOM COMPARTMENT.
Condition: Unknown
Due 1 May 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 16 August 1987
Resolved
RENEW THE STERN FRAME PORTSIDE.
Condition: Unknown
Due 1 May 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 3 April 1985
Resolved
RENEW APX. 13 FT OF 3"X6" CHINE LOG, 4 EA 2"X4 1/2" FRAMES.
Condition: Unknown
Due 3 April 1985
Resolved 3 April 1985