The 6 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Share this recordDownload vessel cardDownload QRMaury, US Coast Guard vessel record for DAFNIS, retrieved 18 September 2026. mauryrecords.com/v/psix-418506.html
Documentation record
Tonnage as PSIX records it13586 - Regulatory (Subpart C or D), Gross Ton 6447 - Regulatory (Subpart C or D), Net Ton 23000 - Displacement, Ton 16728 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 6
18 June 2002Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1633376
2 May 2002Ballast Water Examination · Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1612116
24 May 2001Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 207187
24 May 2001Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 290388
24 May 2001Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 771195
9 September 2000Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 281981
REPAIR/RENEW AS ORIGINAL, SUCTION GUAGE ON #1 FIRE PUMP. LEGACY COMPONENT DESC: Suction Valve
Action required: 705 - Other - as specified
Due 16 May 2002
Resolved 18 June 2002
Resolution: Sighted classification society correcton report noting gage replaced.
Electrical › Electric Generation Source (service)
Issued 2 May 2002Resolved
REPAIR ALL LEAKING CYLINDER LINERS ON #2 SHIP DIESEL GENERATOR
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2002
Resolved 18 June 2002
Resolution: Reviewed classification society report of repairs completed.
Electrical › Electric Generation Source (emergency)
Issued 2 May 2002Resolved
RENEW AS ORIGINAL, STRIPPED BOLT ON TOP OF #1 SHIP SERVICE DIESEL GENERATOR, SECONDARY FUEL FILTER. AREA IS LEAKING EXCESSIVE FUEL. LEGACY COMPONENT DESC: Generator
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2002
Resolved 18 June 2002
Resolution: Reviewed classification society correction report.
Engineering › Sea-water System (primary cooling)
Issued 2 May 2002Resolved
REPAIR / RENEW AS ORIGINAL, SOFT PATCH ON #3 MAIN SEA WATER PUMP. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2002
Resolved 18 June 2002
Resolution: Pipe section renewed, sighted classification society correction report.
Construction/Loadline › Hull
Issued 2 May 2002Resolved
CLASSIFICATION SOCIETY TO PROVIDE SURVEY OF HULL.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 August 2002
Resolved 25 July 2002
Resolution: Received fax report from BV Class Surveyor. An annual hull exam was completed and found satisfactory.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 2 May 2002Resolved
VESSEL TO HAVE CO2 BOTTLES IN ENGINE ROOM (3 BOTTLES) SERVICED PRIOR TO DEPARTURE FROM THE PORT OF PASCAGOULA, MISSISSIPPI. LEGACY COMPONENT DESC: Tanks
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 May 2002
Resolved 3 May 2002
Resolution: RECEIVED REPORT FROM FIRE PROTECTION SERVICE (FPS) ATTESTING TO THE SERVICING OF 3 BOTTLES.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.