Professional
The full record for this vessel
Behind this panel: 13 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 13
15 November 2019
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6856377
7 May 2019
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6675453
12 October 2018
PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6557467
14 September 2018
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6540519
17 February 2018
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6355649
9 February 2018
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6352764
17 August 2017
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6243725
15 August 2017
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6234680
31 July 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6226039
5 May 2017
PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6131722
27 March 2017
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6112032
30 September 2016
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6013170
14 August 2016
PI Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5961377
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 7 May 2019
Resolved
Watertight doors of satisfactory construction may be fitted to internally subdivide large cargo spaces, provided that the administration is satisfied that such doors are essential. Such doors shall be kept closed during navigation. The time of opening such doors in port and closing them before the ship leaves shall be entered in the log-book. Vessel’s water tight doors were found with numerous dogging equipment out of adjustment and inoperable. Doors are unable to operate properly and cannot ensure water tight integrity. Additionally, vessel did not log door opening and closing times at last port. Cite: 74 SOLAS (04’ CONS) CH II-1/25-9.4 (17C)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 May 2019
Resolved 7 May 2019
Resolution: Vessel adjusted doors and demonstrated proper operation.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 7 May 2019
Resolved
Watertight doors of satisfactory construction may be fitted to internally subdivide large cargo spaces, provided that the administration is satisfied that such doors are essential. Such doors shall be kept closed during navigation. Gasket Material at sealing surface is deteriorated affecting water-tight integrity. Cite: 74 SOLAS (04’ CONS) CH II-1/25-9.4 (50a,c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2019
Resolved 15 November 2019
Resolution: Recieved class report attesting to correction.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 May 2019
Resolved
Fixed gas fire-extinguishing systems: Means shall be provided to close all openings which may admit air to or allow gas to escape from a protected space. Numerous self-closing doors for ladder wells that service cargo spaces were found with hold back devices which would permit CO2 to escape from protected spaces. Cite: 74 SOLAS (97 cons) ch II-2/5-1.4 (10 C)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 7 May 2019
Resolved 7 May 2019
Resolution: hold backs removed: corrected on the spot
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 7 May 2019
Resolved
Each completed page of a vessel's oil record book pt 1. shall be signed by the master. 6 pages from 02MAY19 to 05MAY19 were found not signed. Cite: Marpol (17 cons) Annex 1/17.4 (10C)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 7 May 2019
Resolved 7 May 2019
Resolution: Master Signed respective pages/ Corrected on the Spot
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 7 May 2019
Resolved
Access doors normally closed at sea intended to ensure the watertight integrity,shall be provided with means of indication on the bridge showing whether these doors are open or closed. Indicator on the bridge was inoperable for power operated water tight doors subdividing cargo spaces. Cite: 74 Solas (04 Cons.) CH II-1/25-9.3 (50 a,c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2019
Resolved 15 November 2019
Resolution: Recieved class report attesting to correction.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 7 May 2019
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations. Vessel has checklist for watertight door maintenence and for departure checks to include WTD being inspected / closed. All of the vessel's water tight doors dividing cargo spaces were not dogged fully. One had over half of dogs undone. The other two had over 75% of dogs undone. Dogs were in a condition that took several hours to fully close. Ship has not been logging open/closed in accordance with deficiency 01. Recommend external Audit. Cite: 74 Solas(14) IX/3.1 : ISM Code 3.1 (50 a/c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2019
Resolved 15 November 2019
Resolution: Recieved class report attesting to correction.
Engineering › Generator (propulsion/auxiliary-electric) › Generator Voltage Regulator Circuitry
Issued 15 August 2017
Resolved
1499: Under any survey of the ship under regulations 7, 8, 9, or 10 has been completed, no change shall be made in the structural arrangements, machinery equipment and other items covered by the survey without the sanction of the administration. During test of emergency diesel generator it was observed that the tachometer was not functional. SOLAS 74 Ch. 1 Reg 11(b). action 15a.c.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 August 2017
Resolution: Cause was due to contact failure of the electrical terminal for the tachometer of the emergency generator. After cleaning, tachometer was working properly. Class report attached in documents.
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 14 August 2016
Resolved
PSCO observed a modification in the wet provisions store room consisting of brass tubing protuding the bulkhead to drain condensation from the overhead piping.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 September 2016
Resolution: It is confirmed by a class report that the modification was removed and repaired. Deficiency is cleared.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 14 August 2016
Resolved
Flammable and corrosive liquids were improperly stored throughout the engine room in quantities in excess of the acceptable amounts.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 15 August 2016
Resolution: The crew removed the improperly stored materials. Deficiency was cleared on the spot.