CEC FUTURE

CEC FUTURE is a 1994 freight ship. The Coast Guard has recorded 20 inspections since 1998, most recently in July 2012, along with 8 deficiencies and 2 operational controls.

Records from 1998 to 2012. Most recent: inspection, 8 July 2012.

Built
1994
Last inspected
8 July 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9076351 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
418529
Flag
BAHAMAS, THE
—
Maury page id
psix-418529

Inspections, by type

…with no type recorded11
Years with a record 11 calendar years (1998–2012)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it4980 - Convention (Subpart B), Gross Ton
2230 - Convention (Subpart B), Net Ton
7308 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CASEY LUCK Commercial Fishing Vessel · MISLE 442943 · 21 December 1998 · activity 35559

Inspection history · 20

8 July 2012 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4364923
23 January 2012 COE-Dockside
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4226691
17 August 2011 Type not recorded
No type recorded · Station Dauphin Island · USCG Heartland District (CGD-H) · Activity 4123665
3 January 2011 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3919284
6 December 2010 COE-Dockside · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3905278
14 July 2008 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3267432
7 October 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3074639
28 September 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3068664
25 February 2007 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2877183
9 May 2004 Annual Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2063719
25 June 2002 Deficiency Check · Examination of Repairs
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1635911
23 August 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 292999
7 April 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 276613
28 May 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 429025
2 April 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 427228
22 December 1998 Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 808512
21 December 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 35559
30 October 1998 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 422121
15 June 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 46138
18 February 1998 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 412944

Deficiency record · 8

Navigation › Collision/Grounding Avoidance › Radar
Issued 7 October 2007 Resolved
Vessel requested a deviation from the rules to enter the COTP zone of New Orleans with an inoperative radar.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 October 2007
Resolved 7 October 2007
Resolution: Received tech report from [name withheld] LTD satisfying requirement.
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 22 June 2002 Resolved
Turbo charger gas outlet casing was holed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 June 2002
Resolution: Satisfactorily repaired. Tech rep changed out turbo charger gas outlet casing and gas inlet casing. Witnessed dock test of system.
Fire Fighting
Issued 23 August 2001 Resolved
Provide adequate gasket for fire doors to allow door to completely seal. SOLAS 74 amd II-2.47_x001C_ Item to be corrected prior to next U.S. port after sailing foreign.
Condition: Unknown
Due 23 September 2001
Resolved 24 June 2002
Fire Fighting
Issued 23 August 2001 Resolved
Repair or replace SCBA air leak, near whistle and gauge assembly._x001C_ SOLAS 74 amd II-2.17_x001C_ ITEM TO BE CORRECTED PRIOT TO DEPARTURE
Condition: Unknown
Due 23 August 2001
Resolved 24 August 2001
Fire Fighting
Issued 2 April 1999 Resolved
PRIOR TO 02MAY99, REPAIR/REPLACE WASTED CO2 STORAGE CABINET AT FORECASTLE PAINT STORES.
Condition: Unknown
Due 28 May 1999
Resolved 28 May 1999
Documentation
Issued 2 April 1999 Resolved
PRIOR TO 02MAY99, PROVIDE FLAG/CLASS SURVEYORS REPORT ADDRESSING LACK OF LIFEJACKET STOWAGE AT MUSTER STATION OR EMBARKATION DECK. CREW STORES ALL LIFEJACKETS IN ACCOMODATIONS, WITH NONE AVAILABLE IN EMERGENCY STOWAGE.
Condition: Unknown
Due 28 May 1999
Resolved 28 May 1999
Documentation
Issued 2 April 1999 Resolved
PRIOR TO 02MAY99, PROVIDE DOCUMENTATION FROM FLAG ADMINISTRATION INDICATINGTHAT THEY ACCEPT HOME FLAG (PHILLIPINE) LICENSES OF OFFICERS ON BOARD.
Condition: Unknown
Due 28 May 1999
Resolved 28 May 1999
Documentation
Issued 18 February 1998 Resolved
PROVIDE OIL TRANSFER PROCEDURES (BUNKERING) THAT MEET THE REQUIREMENTS OF 33 C.F.R. 155.750
Condition: Unknown
Due 18 February 1998
Resolved 18 February 1998

Ownership record