Records from 2016 to 2025. Most recent: inspection, 11 June 2025.
Inspection history · 18
11 June 2025
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8157502
8 October 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8026715
13 June 2024
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7934575
19 October 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7813113
13 June 2023
Administrative Inspection · Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7714449
16 June 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7479488
23 September 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7321734
17 May 2021
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7213570
23 September 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7072932
10 July 2020
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7003138
7 October 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6840393
3 June 2019
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6702626
28 September 2018
Internal Structural Exam · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6550788
12 June 2018
COI Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6421912
27 September 2017
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6264347
13 June 2017
Examination of Repairs · COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6162694
6 October 2016
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6020892
27 May 2016
Examination of Repairs · COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5888456
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 June 2025
No resolution recorded
Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level. Vessel shaft space has centerline separation, restricting water flow. Sensors independent, but only one alarms on bridge. Vessel to rig both to indicate on bridge before next operational season in 2026.
Action required: 705 - Other - as specified
Due 22 June 2026 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 13 June 2024
Resolved
At each initial and subsequent inspection for
certification of a vessel, the owner or managing
operator shall be prepared to conduct tests and have
the vessel ready for inspections of the hull structure
and its appurtenances,
The vessel is leaking water near the shaft
penetration / bulkhead. Operator shall identify the
source and cease the water intrusion to the
satisfaction of the marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2024
Resolved 4 July 2024
Resolution: Vessel has approved temp repairs.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 June 2024
Resolved
46 CFR 115.810(b); The vessel must conduct the following inspections and tests: For fixed-gas fire extinguishing systems, the inspections and tests required by Table 115.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. Vessel must provide evidence of the required servicing to the inspector. The pre-engineered firefighting system with no servicing reports.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 July 2024
Resolution: Confirmed servicing was completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 June 2024
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel had placards only posted below, away from the majority of life jacket stowage.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 July 2024
Resolution: Placards posted.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 June 2024
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Vessel had no marking on the rear stairway access to the upper deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 July 2024
Resolution: Placard installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 June 2024
Resolved
Each ring life buoy on a vessel must: Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. Vessel had 01 ring buoy with no approval type.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 July 2024
Resolution: Correct buoy's installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 June 2024
Resolved
The marine employer shall ensure that all persons directly involved in a serious marine incident are chemically tested for evidence of dangerous drugs and alcohol in accordance with the requirements of 46 CFR 4.06. Vessel had no policy nor testing capabilities established to meet the timeline requirements.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 July 2024
Resolution: Vessel has testing capabilities.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 June 2024
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel had 6 un-serviceable lifejackets.
Action required: 10 - Deficiency Rectified
Resolved 11 July 2024
Resolution: New LJ onboard.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 13 June 2024
Resolved
At each initial and subsequent inspection for
certification of a vessel, the owner or managing
operator shall be prepared to conduct tests and have
the vessel ready for inspections of the hull structure
and its appurtenances,
The vessel is leaking water near the shaft
penetration / bulkhead. Operator shall identify the
source and cease the water intrusion to the
satisfaction of the marine inspector prior to next credit DDX.
Action required: 705 - Other - as specified
Resolved 21 July 2025
Resolution: Vessel 2024 yard repairs significantly decreased water ingress. See narrative for details.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 June 2023
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Identification of the items may be in words, or the appropriate symbols in International Maritime Organization (IMO) Resolution A.760(18), “Symbols Related to Life-Saving Appliances and Arrangements.” Letters and numbers must be at least 50 millimeters (2 inches) high. Symbols must be at least 100 millimeters (4 inches) square.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2023
Resolved 29 July 2023
Resolution: Received signed letter from Master attesting to correction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 June 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Port MDE not operational. Must be rectified prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 July 2023
Resolved 29 July 2023
Resolution: Received signed letter from Master attesting to correction.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 June 2023
Resolved
L. The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 psi at the pump outlet. The pump outlet shall be fitted with a pressure gauge. Must be corrected prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 July 2023
Resolution: Received signed letter from Master attesting to correction.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 13 June 2023
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2023
Resolved 29 July 2023
Resolution: Received signed letter from Master attesting to correction.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 13 June 2023
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, flooding, heavy weather, or man overboard conditions. Instructions faded.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2023
Resolved 29 July 2023
Resolution: Received signed letter from Master attesting to correction.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 June 2023
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2023
Resolved 29 July 2023
Resolution: Received signed letter from Master attesting to correction.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 13 June 2023
Resolved
Provide evidence of vessel's inflatable buoyant apparatus being placed back on the vessel appropriately.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 July 2023
Resolved 29 July 2023
Resolution: Received signed letter from Master attesting to correction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 June 2023
Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5 °C (150 °F), must be insulated where necessary to prevent injuries. Replace lagging on MDE exhaust.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2023
Resolved 29 July 2023
Resolution: Received signed letter from Master attesting to correction.
Construction/Loadline › Hull › Stiffener
Issued 6 October 2016
Resolved
Starboard buttblock at third strake from garboard, located just aft of house structure showed signs of rot and failure. Crop and renew failed block to original scantlings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 13 June 2017
Resolution: Verified repairs during COI inspection.
Construction/Loadline › Hull › Stringer
Issued 6 October 2016
Resolved
Starboard side strake, 11 strakes outboard of garboard, along the aft of house structure, showed signs of rot and failure. Crop and renew failed plank to original scantlings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 13 June 2017
Resolution: Verified repairs during 2017 COI inspection.