Passenger (Inspected) · Passenger Ship class · Built 1920s · USCG Northwest District (CGD-NW) · Other hulls named INTERNATIONAL
INTERNATIONAL is a 1927 passenger vessel (inspected). The Coast Guard has recorded 75 inspections since 1985, most recently in June 2025, along with 117 deficiencies — 1 with no resolution recorded — and 1 operational control.
Records from 1985 to 2025. Most recent: inspection, 11 June 2025.
- Built
- 1927
- Last inspected
- 11 June 2025
- Documentation
- Expired · documentation file of 10 September 2026
- Deficiencies
- 117 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
227179
WDF3795
41854
Flag
UNITED STATES
367444080, 368400830
Maury page id
psix-41854
Inspections, by type
…with no type recorded2
…past their stated due date1
Years with a record
39 calendar years (1985–2025)
The 75 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)73.0 ft × 17.2 ft × 2.8 ft
Registered tonnagegross 56 / net 38
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJ. W. SWANSON · WATERTON LAKE, MT, UNITED STATES · built 1927
Hull materialWood
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSEATTLE, WA
Trade endorsementsRecreational, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it56 - Regulatory (Subpart C or D), Gross Ton
38 - Regulatory (Subpart C or D), Net Ton
38 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDP9630MMSI 368400830 · active · compulsorily equipped · granted 15 January 2025, expires 15 January 2035
WDF3795MMSI 367444080 · active · voluntarily equipped · granted 14 March 2020, expires 23 March 2030
WDF7041MMSI 338530000 · expired · compulsorily equipped · granted 1 March 2011, cancelled 1 May 2021
WTR8987MMSI not assigned · expired · compulsorily equipped · granted 25 March 1997, cancelled 10 June 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 75
11 June 2025
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8157502
8 October 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8026715
13 June 2024
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7934575
19 October 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7813113
13 June 2023
Administrative Inspection · Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7714449
16 June 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7479488
23 September 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7321734
17 May 2021
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7213570
23 September 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7072932
10 July 2020
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7003138
7 October 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6840393
3 June 2019
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6702626
28 September 2018
Internal Structural Exam · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6550788
12 June 2018
COI Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6421912
27 September 2017
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6264347
13 June 2017
Examination of Repairs · COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6162694
6 October 2016
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6020892
27 May 2016
Examination of Repairs · COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5888456
29 September 2015
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5745937
24 June 2014
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4887798
6 June 2012
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4335764
8 December 2011
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4204406
26 September 2011
Hull Examination · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4160281
24 September 2010
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3864416
16 October 2008
Internal Structural Exam · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3359042
18 June 2008
Deficiency Check · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3219012
23 October 2007
Hull Examination · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3085734
11 June 2007
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2958310
6 June 2007
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2953664
2 October 2006
Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2799434
20 June 2006
MTSA/ISPS Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2641773
26 September 2005
Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2505368
20 May 2005
COI Inspection · Internal Structural Exam · MTSA/ISPS Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2363121
20 June 2004
MTSA/ISPS Verification · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2104254
6 February 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2001824
21 October 2003
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1933332
17 June 2003
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1927376
3 October 2002
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1688153
18 June 2002
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1640743
28 May 2002
Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1622073
26 June 2001
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1068150
21 June 2001
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1437924
14 June 2000
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1443047
1 November 1999
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1131113
9 September 1999
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1122453
10 June 1999
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1393191
14 May 1998
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1090122
14 May 1998
Re-Inspection · Hull Examination · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1128436
25 July 1997
Re-Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1386055
24 March 1997
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1104459
21 June 1996
Deficiency Check · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1095491
8 May 1996
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1088240
6 February 1996
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 874088
15 December 1995
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1191416
17 June 1995
Hull Examination · COI Inspection · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1079254
8 August 1994
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1181076
12 July 1994
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1177047
22 June 1994
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1136020
22 June 1994
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1136021
8 September 1993
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1431271
19 July 1993
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1157885
17 June 1993
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1403631
16 June 1992
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 947008
16 May 1992
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 826008
27 December 1991
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1270998
6 August 1991
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 944014
20 June 1991
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 914054
20 June 1990
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 901321
23 May 1990
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 931885
14 June 1989
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1344819
26 August 1988
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1347349
9 June 1988
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1205038
11 June 1987
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1010924
3 June 1986
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1302184
10 June 1985
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1295818
Deficiency record · 117
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 June 2025
No resolution recorded
Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level. Vessel shaft space has centerline separation, restricting water flow. Sensors independent, but only one alarms on bridge. Vessel to rig both to indicate on bridge before next operational season in 2026.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 13 June 2024
Resolved
At each initial and subsequent inspection for
certification of a vessel, the owner or managing
operator shall be prepared to conduct tests and have
the vessel ready for inspections of the hull structure
and its appurtenances,
The vessel is leaking water near the shaft
penetration / bulkhead. Operator shall identify the
source and cease the water intrusion to the
satisfaction of the marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 June 2024
Resolved
46 CFR 115.810(b); The vessel must conduct the following inspections and tests: For fixed-gas fire extinguishing systems, the inspections and tests required by Table 115.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. Vessel must provide evidence of the required servicing to the inspector. The pre-engineered firefighting system with no servicing reports.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 June 2024
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel had placards only posted below, away from the majority of life jacket stowage.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 June 2024
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Vessel had no marking on the rear stairway access to the upper deck.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 June 2024
Resolved
Each ring life buoy on a vessel must: Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. Vessel had 01 ring buoy with no approval type.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 June 2024
Resolved
The marine employer shall ensure that all persons directly involved in a serious marine incident are chemically tested for evidence of dangerous drugs and alcohol in accordance with the requirements of 46 CFR 4.06. Vessel had no policy nor testing capabilities established to meet the timeline requirements.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 June 2024
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel had 6 un-serviceable lifejackets.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 13 June 2024
Resolved
At each initial and subsequent inspection for
certification of a vessel, the owner or managing
operator shall be prepared to conduct tests and have
the vessel ready for inspections of the hull structure
and its appurtenances,
The vessel is leaking water near the shaft
penetration / bulkhead. Operator shall identify the
source and cease the water intrusion to the
satisfaction of the marine inspector prior to next credit DDX.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 June 2023
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Identification of the items may be in words, or the appropriate symbols in International Maritime Organization (IMO) Resolution A.760(18), “Symbols Related to Life-Saving Appliances and Arrangements.” Letters and numbers must be at least 50 millimeters (2 inches) high. Symbols must be at least 100 millimeters (4 inches) square.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 June 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Port MDE not operational. Must be rectified prior to carrying passengers.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 June 2023
Resolved
L. The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 psi at the pump outlet. The pump outlet shall be fitted with a pressure gauge. Must be corrected prior to carrying passengers.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 13 June 2023
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operations.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 13 June 2023
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, flooding, heavy weather, or man overboard conditions. Instructions faded.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 June 2023
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 13 June 2023
Resolved
Provide evidence of vessel's inflatable buoyant apparatus being placed back on the vessel appropriately.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 June 2023
Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5 °C (150 °F), must be insulated where necessary to prevent injuries. Replace lagging on MDE exhaust.
Construction/Loadline › Hull › Stiffener
Issued 6 October 2016
Resolved
Starboard buttblock at third strake from garboard, located just aft of house structure showed signs of rot and failure. Crop and renew failed block to original scantlings.
Construction/Loadline › Hull › Stringer
Issued 6 October 2016
Resolved
Starboard side strake, 11 strakes outboard of garboard, along the aft of house structure, showed signs of rot and failure. Crop and renew failed plank to original scantlings.
Construction/Loadline › Structures › Plowshare Breakwater
Issued 29 September 2015
Resolved
Stem noted with decay and hood ends of planks also noted with decay at attachment to stem. Replace stem and affected planks to original structure.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 24 September 2010
Resolved
Port and Starboard propellors reveal moderate pitting; Replace both propellers with like original.
Construction/Loadline › Penetrations › Valve Flange
Issued 16 October 2008
Resolved
Requirement to exercise and lube starboard engine cooling water valve.
Construction/Loadline › Hull › Hull Plating
Issued 16 October 2008
Resolved
Replace the completely removed wood transom and starboard end frame that the transom fastens to.
Construction/Loadline › Hull › Bottom Plating
Issued 16 October 2008
Resolved
In #2 water-tight space port side, 3 feet aft of water-tight subdivision bulkhead, 3 planks up from keel, repair rot and schedule plank replacement next DDX.
Construction/Loadline › Hull › Bottom Plating
Issued 16 October 2008
Resolved
Replace 2 planks starboard side before turn of bilge 20 feet forward of transom, outboard of aft engine room space.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 16 October 2008
Resolved
Repair port shaft guide bearing mount located forward of stern tube and shaft packing gland and align and secure guide bearing to new foundation.
Engineering › Steering Gear System › Rudder Bearing
Issued 16 October 2008
Resolved
Re-pour lead babbitt into lower guide bearing for rudder. (Single rudder duel shaft vessel).
Engineering › Diesel Engine (propulsion-reduction gear) › Valve Actuating Gear
Issued 18 June 2008
Resolved
Linkage to Reduction Gear loose
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 18 June 2008
Resolved
Un mounted fire ex
Engineering › Bilge Water Management System › Pump
Issued 18 June 2008
Resolved
Han portable bilge/fire pump diaphram damaged
Construction/Loadline › Hull › Stringer
Issued 18 June 2008
Resolved
WT bulkhead port side of Fantell at shaft log need to be made water tight small gap to be completed at next DDX
Construction/Loadline › Hull › Hull Plating
Issued 23 October 2007
Resolved
Repair plank on port side 5 above from stem to fr 6.
Construction/Loadline › Hull › Hull Plating
Issued 23 October 2007
Resolved
Repair plank stbd side 8 above mid ships located under aft cabin bunk.
Construction/Loadline › Hull › Hull Plating
Issued 23 October 2007
Resolved
Remove and repair rot as requiered on transom.
Construction/Loadline › Hull › Bracket
Issued 23 October 2007
Resolved
Remove/inspect/repair but block located on exterior of hull in way of engine bed port side.
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 June 2007
Resolved
Prove proper operation of bilge alarms.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 6 June 2007
Resolved
Repair s/w cooling leak on port engine exhaust manifold.
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 June 2007
Resolved
Clearly label bilge alarms and automatic bilge pumps operating indicators at operating station.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 6 June 2007
Resolved
Include emergency exit instructions during passenger orientation and label same.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 6 June 2007
Resolved
Provide Echo-sounding Device.
Construction/Loadline › Hull › Hull Plating
Issued 2 October 2006
Resolved
Port side amid ship 3 planks removed and to be replaced
Bent frame port side under fuel tank crack at turn of bilge replace or sister
Construction/Loadline › Structures › Superstructure
Issued 20 June 2006
Resolved
Bring railing into compliance w/ 46 CFR 177.900(d)(1) & (g) -- (177.35-1(c) in "Old T") : 39.5" w/ either wire mesh or 4" slats. Where built in lifejacket seat/container butts against the stern rail back aft where a, measurement is to be taken from seats.
Lifesaving › Rescue Boat › Boarding Ladder
Issued 20 June 2006
Resolved
During drill determined that rescue boat unable to adequately retrieve person from water. Provide adequate means to recover person from water to meet 180.210(b)
Lifesaving › Buoyant Apparatus › Capacity
Issued 20 June 2006
Resolved
Due to cold water, lack of rescue resources CG can no longer exempt all of SOLAS CH III; provide appropriate percentage of primary lifesaving by 06/18/07. Service interval of 2 years used on other company boats-- [name withheld] & Roddy Paul-- is acceptable.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 20 June 2006
Resolved
Change abandon ship/catastrophic ship's procedures, including placard, to have passengers move out of enclosed space & don lifejackets.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 20 June 2006
Resolved
Improve training procedures & documentation for fire/flooding & abandon ship to match vessel configuration after modified.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 20 June 2006
Resolved
Several holes & gaps in all transverse bulkheads; they are not watertight. Make repairs & make all bulkheads watertight.
Construction/Loadline › Hull › Bottom Plating
Issued 26 September 2005
Resolved
Make permanent repairs to two planks found with dry rot prior to placing the vessel back into service following winter layup.
Lifesaving
Issued 21 June 2001
Resolved
OUTFIT THE VESSEL WITH 02 LADDERS THAT CAN BE USED TO EVACUATE VESSEL AND RETRIVE PERSON IN WATER.
Construction/Loadline
Issued 21 June 2001
Resolved
During the vessels next DDX, install bilge pumping system in the space aft of blkhead #4 (lazerette)
Lifesaving
Issued 21 June 2001
Resolved
OUTFIT VESSEL W/08 LIFERINGS (4 WITH LINE) TO BE STATIONED AS FOLLOWS: 02 FWD-BOW AREA 01 WITH LINE, 02 AFT 01 WITH LINE, 04 UPPER DECK 02 WITH LINES.
Documentation
Issued 21 June 2001
Resolved
Within the next 6 months (by DEC 22,2001) the M/V INTERNATIONAL shall come into compliance with the International Safty Managment Code.
Lifesaving
Issued 21 June 2001
Resolved
REVISE THE CURRENT EMERGENCY CHECKOFF LIST TO INCLUDE SPECIFIC CREW MEMBER ASSIGNMENTS FOR ROUGH WEATHER AT SEA OR CROSSING HAZARDOUS BAR, MAN OVERBOARD, FIRE AT SEA.
Documentation
Issued 21 June 2001
Resolved
DEVELOP AN EMERGENCY CHECKOFF LIST FOR ABANDON SHIP
Construction/Loadline
Issued 21 June 2001
Resolved
DURING NEXT DDX MAKE BLKHD #4, TO MAXIUM EXTENT POSSIBLE WATER TIGHT.
Construction/Loadline
Issued 21 June 2001
Resolved
During vessels next DDX,install bilge high level alarm in the space aft of blkhd #4 (lazerette)
Fire Fighting
Issued 9 September 1999
Resolved
TEST NEW ENGINE SPACE FIRE SUPPRESION SYSTEM IN PRESENCE AND TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Fire Fighting
Issued 10 June 1999
Resolved
PROVIDE APPROVED FIRE SUPPRESSION SYSTEM FOR ENGINE ROOM IN ACCORDANCE WITH46CFR118.400.
Construction/Loadline
Issued 14 May 1998
Resolved
REPAIR FRAMES 3,6,7, AND 8 ON PORT SIDE, AFT OF COLLISION BULKHEAD.
Navigation
Issued 14 May 1998
Resolved
MAKE MAST/ANCHOR LIGHT OPERATIONAL.
Construction/Loadline
Issued 14 May 1998
Resolved
INSTALL STRINGER,PORT SIDE AFT, IN ENGINE ROOM TO SUPPORT 4 X 4.
Construction/Loadline
Issued 14 May 1998
Resolved
DOUBLE CLAMP FLEX HOSE IN BILGE OVERBOARD DISCHARGE LINE.
Lifesaving
Issued 21 June 1996
Resolved
POST LIFE JACKET DONNING INSTRUCTIONS.
Construction/Loadline
Issued 21 June 1996
Resolved
MAKE PROPER REPAIR TO #6 PORT FRAME LOCATED IN THE FOREPEAK IN WAY OF SISTER._x001C_ TO BE COMPLETED AT NEXT DDX.
Construction/Loadline
Issued 21 June 1996
Resolved
PROVIDE VALVE ON BILGE LINE THROUGH COLLISION BULKHEAD AS PER 152.25-5d.
Documentation
Issued 21 June 1996
Resolved
PROVIDE COPY OF VALID DATED CERTIFICATE OF DOCUMENTATION TO OFFICE AND HAVEORIGINAL ONBOARD.
Lifesaving
Issued 21 June 1996
Resolved
CLEAN ENGINE SPACE.
Engineering
Issued 21 June 1996
Resolved
DOUBLE HOSE CLAMP PORT AND STARBOARD ENGINE RAW WATER COOLING HOSES.
Electrical
Issued 21 June 1996
Resolved
PROVIDE INSULATING COVERS ON BATTERIES TERMINALS.
Lifesaving
Issued 21 June 1996
Resolved
REPLACE FWD STARBOARD RING BUOY.
Construction/Loadline
Issued 21 June 1996
Resolved
REMOVE ROT LOCATED AT THE BOTTOM STARBOARD AREA OF THE COLLISION BULKHEAD, AND SUBMIT PROPOSAL FOR PROPER REPAIR.
Navigation
Issued 21 June 1996
Resolved
REMOVE EXCESSIVE SLACK IN STEERING CABLE.
Engineering
Issued 21 June 1996
Resolved
LAG EXHAUST PORT ENGINE.
Fire Fighting
Issued 21 June 1996
Resolved
PROPERLY MOUNT ALL FIRE EXTINGUISHERS.
Fire Fighting
Issued 21 June 1996
Resolved
REPAIR WATER LEAKS STARBOARD FIRE/BILGE PUMP.
Lifesaving
Issued 21 June 1996
Resolved
REPLACE GRAB LINE ON STARBOARD RING BUOY._x001C_ TO BE COMPLETED PRIOR TO CARRYING PASSENGERS
Lifesaving
Issued 21 June 1996
Resolved
INSTALL RETRO REFLECTIVE MATERIAL ON ALL RING BUOYS.
Lifesaving
Issued 21 June 1996
Resolved
LABEL LIFE JACKET STOWAGE LOCATIONS.
Lifesaving
Issued 21 June 1996
Resolved
PROVIDE RETRO REFLECTIVE MATERIAL ON ALL LIFE JACKETS.
Engineering
Issued 8 May 1996
Resolved
INSTALL LOCKING NUT OR PIN FOR PORT PROP.
Navigation
Issued 8 May 1996
Resolved
REPAIR RUDDER BY PROVIDING NEW UPPER AND LOWER BUSHINGS TO ELEVIATE EXCESS PLAY.
Lifesaving
Issued 17 June 1995
Resolved
PROVIDE 9 ADULT TYPE ONE PFD'S. TOTAL PERSONS ALLOWED IS REDUCED TO 195 UNTIL THIS ITEM IS COMPLETED._x001C_ _x001C_ _x001C_
Unknown
Issued 17 June 1995
Resolved
PROVIDE RANDOM DRUG TESTING DOCUMENTATION IAW 46 16.230 AND 46 CFR 16.260. IN ADDITION, PROVIDE PRE-EMPLOYMENT DOCUMENTATION IAW 46 CFR 16.210.
Lifesaving
Issued 22 June 1994
Resolved
PROVIDE ELEVEN ADDITIONAL TYPE I ADULT PFD'S. TOTAL PERSONS ALLOWED IS REDUCED TO 193 UNTIL THIS ITEM IS COMPLETED._x001C_ _x001C_ _x001C_
Electrical
Issued 22 June 1994
Resolved
PROPERLY CONNECT POSITIVE BATTERY CABLES TO PORT BATTERY._x001C_ _x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 22 June 1994
Resolved
RENEW STEERING CABLE AND REPAIR OR RENEW DAMAGED FRAMING AS DISCUSSED WITH THE MARINE INSPECTOR._x001C_ _x001C_ _x001C_
Fire Fighting
Issued 22 June 1994
Resolved
COMPLETE ANNUAL SERVICING OF ALL FIRE EXTINGUISHERS._x001C_ _x001C_ _x001C_ _x001C_
Electrical
Issued 22 June 1994
Resolved
REMOVE "REMOVABLE ELEMENT" FUSE FROM FIRE PUMP CLUTCH CONTROLLER AND REPLACE WITH UL LISTED FUSE RATED FOR THE CABLE SIZE AND LENGTH OF RUN._x001C_ _x001C_ _x001C_
Engineering
Issued 17 June 1993
Resolved
REPAIR LEAKING SEAL ON STBD MAIN ENGINE RAW WATER PUMP._x001C_ _x001C_ _x001C_ _x001C_
Engineering
Issued 17 June 1993
Resolved
REPAIR AND PROVE OPERATION OF DRIVE OIL GUAGE FOR THE STBD GEAR BOX._x001C_ _x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 17 June 1993
Resolved
INSTALL CHECK VALVE ON THE FORWARD 110V BILGE PUMP DISCHARGE LINE PRIOR TO CARRIAGE OF PASSENGERS._x001C_ _x001C_ _x001C_
Accommodation/Occupational Safety
Issued 17 June 1993
Resolved
INSTALL FORWARD HAND RAILS PRIOR TO CARRIAGE OF PASSENGERS._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 17 June 1993
Resolved
PROVIDE 19 ADDITIONAL ADULT PFD'S. TOTAL PERSONS ALLOWED IS REDUCED TO 184 UNTIL THIS ITEM IS COMPLETED._x001C_ _x001C_ _x001C_
Fire Fighting
Issued 17 June 1993
Resolved
REPLACE ONE 50' X 1 1/2" FIRE HOSE PRIOR TO CARRIAGE OF PASSENGERS._x001C_ _x001C_ _x001C_ _x001C_
Documentation
Issued 16 June 1992
Resolved
PROVIDE PROOF OF VALID FCC STATION LICENSE.
Engineering
Issued 16 June 1992
Resolved
PROPERLY MARK PORT FUELTANK SHUTOFF VAVLE IAW 46 CFR 185.30-20.
Lifesaving
Issued 16 June 1992
Resolved
PROPERLY MARK LIFE PRESERVER STORAGE AREAS AFT IAW 46 CFR 185.30-10
Lifesaving
Issued 16 June 1992
Resolved
RENEW RESCUE BOAT FALLS.
Lifesaving
Issued 16 June 1992
Resolved
PROVIDE 4 ADDTIONAL TYPE 1 PFD'S.
Engineering
Issued 16 June 1992
Resolved
RENEW PORT FUEL TANK VENT FLAME SCREEN IAW 46 CFR 182.20-35(d).
Fire Fighting
Issued 20 June 1991
Resolved
REPLACE THE FLEXIBLE HOSE WITH AN ACCEPTABLE HOSE ON THE PORT FIRE PUMP SEACOCK.
Construction/Loadline
Issued 20 June 1991
Resolved
MAKE PERMANENT ACCEPTABLE REPAIRS TO THE FOLLOWING STRUCTURAL MEMBERS: A. CRACKED FRAME ENG. COMPT. FR 14-PORT B. BAD CLAMP, ENG COMPT. FR 1-PORT C. CRACKED FRAME. ENG. COMPT. FR 29-PORT D. CRACKED FRAMES, CREW CABIN, FR 9&10, STARBOARD
Lifesaving
Issued 20 June 1991
Resolved
APPLY RETROREFLECTIVE MATERIAL TO ALL LIFE JACKETS IN ACCORDANCE WITH 46 CFR 180.25-25.
Fire Fighting
Issued 20 June 1991
Resolved
REMOVE THE NON-METALIC PIPE FROM THE FIREMAIN AND REPLACE WITH MATAL PIPE PER 46 CFR 181.15 AND 182.40-5(B).
Fire Fighting
Issued 20 June 1991
Resolved
INSTALL SUITABLE CHECK VALVES ON THE DISCHARGE PIPE OF EACH FIRE PUMP TO EFFECTIVELY ISOLATE EACH PUMP.
Fire Fighting
Issued 20 June 1991
Resolved
PROVIDE ONE FIRE HOSE NOZZLE PER 46 CFR 181.15-10(D)(2)._x001C_ _x001C_ _x001C_ _x001C_
Electrical
Issued 20 June 1991
Resolved
INSTALL ACCEPTABLE SPLICES IN 110 VOLT AC BILGE PUMP AUTOMATIC SWITCH WIRING.
Fire Fighting
Issued 20 June 1991
Resolved
MAKE WHATEVER REPAIRS NECESSARY TO THE TWO INSTALLED FIRE PUMPS SO THAT THEDISCHARGE PRESSURE AND FLOW REQUIREMENTS OF 46 CFR 181.10-1(C) ARE MET.
Fire Fighting
Issued 20 June 1991
Resolved
INSTALL AN ACCEPTABLE FLEXIBLE HOSE BETWEEN THE STARBOARD FIRE PUMP SUCTIONCOCK AND THE SUCTION PIPING.
Construction/Loadline
Issued 14 June 1989
Resolved
MAKE PERMANENT REPAIRS TO THE FOLLOWING FR'S IN WAY OF THE PORT SIDE.3,8,4,&2 FM FWD BLHD VOID AFT OF E/R. FR'S ROTTED AT TURN OF BILGE. PLANK AT FR 8SOFT AND ROT INDICATED. FR'S 3 & 12 FM FWD BLHD PORT SIDE E/R ROTTED AT TURN OF BILGE. TO BE CROPPED AND RENEWED.
Fire Fighting
Issued 9 June 1988
Resolved
REMOVE THE ENGINE ROOM FIXED EXTINGUISHING SYSTEM, PRIOR TP PLACING THE VESSEL IN SERVICE, TO THE SATISFACTION OF THE COGNIZANT OCMI. (ORIGINALLY ISSUED FOR COMPLIANCE NLT 18JUN88.)
Engineering
Issued 9 June 1988
Resolved
REMOVE NON-METALLIC PIPING MATERIALS FROM THE FIRE AND BILGE SYSTEM AND INSTALL ACCEPTABLE METALLIC MATERIALS, PRIOR TO PLACING THE VESSEL IN SERVICE, TO THE SATISFACTION OF THE COGNIZANT OCMI. (ORIGINALLY ISSUED FOR COMPLIANCE NLT 18JUN88.)
Engineering
Issued 9 June 1988
Resolved
INSTALL A METALLIC CHECK VALVE IN THE FORWARD AUTOMATIC BILGE PUMP OVERBOARD LOCATED STARBOARD SIDE, PRIOR TO PLACING THE VESSEL IN SERVICE, TO THE SATISFACTION OF THE COGNIZANT OCMI. (ORIGINALLY ISSUED FOR COMPLIANCE NLT 18JUN88.)
Engineering
Issued 9 June 1988
Resolved
PROPERLY MARK THE EMERGENCY FUEL SHUT OFF, PRIOR TO PLACING THE VESSEL IN SERVICE, TO THE SATISFACTION OF THE COGNIZANT OCMI. (ORIGINALLY ISSUED FOR COMPLIANCE NLT 18JUN88.)
Fire Fighting
Issued 9 June 1988
Resolved
RENEW THE FIREMAIN DISCHARGE PRESSURE GUAGE, PRIOR TO PLACING THE VESSEL INSERVICE, TO THE SATISFACTION OF THE COGNIZANT OCMI. (ORIGINALLY ISSUED FOR COMPLIANCE NLT 18JUN88.)
Lifesaving
Issued 9 June 1988
Resolved
PROVIDE 15 ADDITIONAL ADULT TYPE I PERSONAL FLOTATION DEVICES, PRIOR TO PLACING THE VESSEL IN SERVICE, TO THE SATISFACTION OF THE COGNIZANT OCMI. (ORIGINALLY ISSUED FOR COMPLIANCE NLT 18JUN88.)
Engineering
Issued 9 June 1988
Resolved
PROVIDE SECOND FIXED POWER BILGE PUMP AS REQUIRED BY 46 CFR 182.25-10A, PRIOR TO PLACING THE VESSEL IN SERVICE, TO THE SATISFACTION OF THE COGNIZANT OCMI.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.