MAURY USCG vessel records Sign in
← All vessels

KELPIE

KELPIE is a 1928 passenger vessel (inspected). The Coast Guard has recorded 68 inspections since 1985, most recently in March 2026, along with 96 deficiencies.

Records from 1985 to 2026. Most recent: inspection, 24 March 2026.

Built
1928
Last inspected
24 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WTR9561
Flag
UNITED STATES
368104380
Maury page id
psix-41855

Inspections, by type

…with no type recorded9
Years with a record 31 calendar years (1985–2026)
The 68 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)57.0 ft × 15.0 ft × 8.6 ft
Registered tonnagegross 30 / net 22
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHARVEY GAMAGE · SOUTH BRISTOL, ME, UNITED STATES · built 1928
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAG HARBOR, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 20 August 2026 · expires 30 September 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it30 - Regulatory (Subpart C or D), Gross Ton
22 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK9516MMSI 368104380 · active · compulsorily equipped · granted 11 July 2019, expires 11 July 2029
WTR9561MMSI 367179220 · expired · compulsorily equipped · granted 10 April 2007, cancelled 10 June 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 68

24 March 2026 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8332265
24 September 2025 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8239662
26 August 2024 Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7986819
24 July 2024 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7965968
29 March 2024 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7887047
13 September 2023 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7790121
16 September 2022 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7560434
6 September 2022 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7548919
7 September 2021 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7306073
27 April 2021 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7183161
16 September 2020 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7055255
14 June 2019 Construction Oversight · Plan Review "T" Boat
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6713832
12 June 2019 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6697753
10 May 2019 Plan Review "T" Boat · COI Inspection · DAPI Audit · Administrative Inspection · Inclining Experiment
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6689728
2 September 2008 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3337184
6 July 2007 COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2985678
22 June 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2952662
21 May 2007 Damage Survey · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2946285
12 September 2006 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2776852
7 July 2006 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2651909
26 May 2006 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2651914
19 September 2005 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2496206
22 July 2005 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2435963
12 April 2004 Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2033478
16 April 2003 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1771534
17 January 2003 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1730826
30 September 2002 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1682874
25 September 2002 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1678208
15 September 2001 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1362482
14 May 2001 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1063516
16 January 2001 Hull Examination · Damage Survey
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1393593
18 January 2000 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1432243
3 June 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1378702
3 June 1999 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1406512
16 February 1999 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1390911
2 February 1998 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1364584
7 March 1997 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1406061
25 February 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 56852
24 January 1997 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1377921
13 December 1995 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 880206
21 November 1995 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1430108
13 February 1995 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1353698
6 July 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 864229
21 June 1994 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1022630
8 March 1994 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 855274
18 January 1994 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1160785
23 February 1993 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1147074
21 January 1993 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1141379
1 September 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 957717
19 June 1992 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1262532
29 January 1992 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1011699
22 January 1992 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1259275
19 April 1991 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 929066
3 April 1991 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1228181
14 March 1991 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 918222
23 January 1991 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 927947
31 October 1990 Hull Examination · Examination of Repairs
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 911432
25 January 1990 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1224803
22 February 1989 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1041211
22 November 1988 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1205489
8 February 1988 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1020335
8 July 1987 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1320193
23 February 1987 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1324032
18 August 1986 Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1030025
25 February 1986 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1304953
30 April 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1292067
16 April 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1291210
19 March 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 982091

Deficiency record · 96

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 September 2025 Resolved
Label fire buckets
Action required: 15 - Rectify deficiencies by next port
Due 24 September 2025
Resolved 24 September 2025
Resolution: resolved prior to completion of inspection.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 26 August 2024 Resolved
Prove proper operation of fixed FF system shutdowns prior to operations.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 August 2024
Resolved 28 August 2024
Resolution: FF system shutdown solenoid was replaced by servicing company. Shutdowns were witnessed to the satisfaction of the attending MI.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 6 September 2022 Resolved
Replace expired hydrostatic release prior to operating more than 3 miles form shore with passengers for hire.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 September 2022
Resolved 6 September 2022
Resolution: O/O provided proof that item was corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 September 2021 Resolved
Install lines and re-label fire buckets.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2021
Resolved 9 September 2021
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 September 2020 Resolved
Prove proper operation of fixed system engine shutdowns.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 September 2020
Resolved 18 September 2020
Resolution: O/O provided proof of proper operation.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 8 August 2008 Resolved
Vessel may not operate with passengers until the following conditions have been met: 1) Make vsl available for inspection; 2) All defs issued on 03AUG07 have been cleared; 3) A suitable and safe dock space has been established; 4) Conduct check-ride with USCG MI aboard, and an appropriately licensed Master.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 28 September 2009
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 26 September 2007 Resolved
Prior to operating with passengers, prove safe passenger embarkation arrangement.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2007
Resolved 9 October 2007
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 26 September 2007 Resolved
Prior to ops w/psgrs, provide life sling for overboard retrieval situation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2007
Resolved 9 October 2007
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 3 August 2007 Resolved
Provide original COD
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 28 September 2009
Documentation › Certificates/Documents › FCC SSL
Issued 3 August 2007 Resolved
Renew FCC SSL
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 28 September 2009
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 3 August 2007 Resolved
Provide FCC Marine Radio Operator's Permit
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 28 September 2009
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 3 August 2007 Resolved
Provide documentation of current chemical testing program
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 26 September 2007
Communications › Radio Communications › EPIRB
Issued 3 August 2007 Resolved
Verify EPIRB registration
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 26 September 2007
Engineering › Sea-water System (primary cooling) › Piping
Issued 3 August 2007 Resolved
Double-clamp raw water hoses in E/R.
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 28 September 2009
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 3 August 2007 Resolved
Lock MSD o/b
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 26 September 2007
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 3 August 2007 Resolved
Replace 1/2" elbow for jacket water cooling
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 26 September 2007
Electrical › Electrical Distribution System (service) › Junction Box
Issued 3 August 2007 Resolved
Cover anchor winch junction box
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 26 September 2007
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 3 August 2007 Resolved
Make vessel available for check-ride under sail, MOB drill, and passenger embarkation review.
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 26 September 2007
Documentation › Markings/Placards › Official Number (US)
Issued 3 August 2007 Resolved
Stencil vessel name on port & stbd bow.
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 26 September 2007
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 12 September 2006 Resolved
Make LPG system comply with 46CFR184.240. LPG system may not be used.
Action required: 705 - Other - as specified
Resolved 28 September 2009
Fire Fighting › Structural - B Class Divisions › Main Galleys
Issued 17 July 2006 Resolved
Make galley comply with structural fire protection requirements of 46 CFR 177.410. Galley may not be used.
Action required: 705 - Other - as specified
Resolved 28 September 2009
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 17 July 2006 Resolved
Propane bottle used for cooking appliances cannot be located within 24" of any opening leading below deck. Bottle cannot be used.
Action required: 705 - Other - as specified
Due 17 August 2006
Resolved 12 September 2006
Resolution: Cleared and reissued.
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 17 July 2006 Resolved
Make wire penetration in propane cylinder storage box air tight.
Action required: 705 - Other - as specified
Due 17 August 2006
Resolved 12 September 2006
Resolution: Cleared and reissued.
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 17 July 2006 Resolved
Provide vent at bottom of propane cylinder storage box.
Action required: 705 - Other - as specified
Due 17 August 2006
Resolved 12 September 2006
Resolution: Cleared and reissued.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 7 July 2006 Resolved
Ensure fixed firefighting system in engine room is properly serviced and inspected, and provide completed servicing certificate.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 August 2006
Resolved 17 July 2006
Resolution: Provided satisfactory servicing certificate.
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 7 July 2006 Resolved
Ensure proper number of distress signals are on board vessel.
Action required: 705 - Other - as specified
Due 7 August 2006
Resolved 17 July 2006
Resolution: Provided correct number of visual distress signals.
Fire Fighting › Fire Bucket › Lanyard
Issued 7 July 2006 Resolved
Attach proper length lanyard to fire buckets.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 August 2006
Resolved 17 July 2006
Resolution: Attached lanyards to fire buckets.
Documentation › Certificates/Documents › FCC SSL
Issued 7 July 2006 Resolved
Provide FCC Radio Safety Certificate.
Action required: 705 - Other - as specified
Due 7 August 2006
Resolved 17 July 2006
Resolution: Provided FCC Safety Radio Certificate.
Lifesaving › Lifebuoys › Size
Issued 7 July 2006 Resolved
Provide 24 inch ring buoy, properly stenciled with vessel's name, and water light attached with a corrosion resistant clip.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 August 2006
Resolved 17 July 2006
Resolution: Provided 24" ring buoy, stenciled with vessel name, and water light with clip attached.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 7 July 2006 Resolved
Provide alcohol testing kit.
Action required: 705 - Other - as specified
Due 7 August 2006
Resolved 17 July 2006
Resolution: Provided alcohol test kits from conforming products list.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 July 2006 Resolved
Tighten grab rails on port and starboard sides of vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 August 2006
Resolved 17 July 2006
Resolution: Tightened life lines.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 7 July 2006 Resolved
Install drip shields for electrical distribution panels.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 August 2006
Resolved 17 July 2006
Resolution: Installed drip shields.
Engineering › Bilge Water Management System › Hose
Issued 7 July 2006 Resolved
Renew kinked bilge discharge hoses in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 August 2006
Resolved 17 July 2006
Resolution: Renewed hoses.
Operations/Management › Drills/Instruction › Fire
Issued 7 July 2006 Resolved
Conduct man overboard and fire drills in the presence of a USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 August 2006
Resolved 17 July 2006
Resolution: Conducted fire and man overboard drill.
Communications › Radio Communications › EPIRB
Issued 7 July 2006 Resolved
Properly mount EPIRB.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 August 2006
Resolved 17 July 2006
Resolution: Properly mounted EBIRB.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 22 July 2005 Resolved
Complete annual and hull examinations prior to carrying passengers.
Action required: 705 - Other - as specified
Due 30 September 2005
Resolved 19 October 2005
Resolution: Vessel voluntarily removed from service by owners.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 15 January 2003 Resolved
Replace expiring EPIRB battery.
Action required: 705 - Other - as specified
Due 15 February 2003
Resolved 24 January 2003
Resolution: EPIRB Battery Replaced.
Engineering › Bilge Water Management System
Issued 25 September 2002 Resolved
Repair installed hand bilge pump. Diaphram is leaking, preventing the pump from operating properly. LEGACY COMPONENT DESC: Pump
Action required: 705 - Other - as specified
Due 25 September 2002
Resolved 25 September 2002
Resolution: Corrected while on board.
Engineering › Bilge Water Management System
Issued 25 September 2002 Resolved
Provide an operable bilge alarm for the main bilge space.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 October 2002
Resolved 30 September 2002
Resolution: Installed a new 3 station bilge alarm system.
Lifesaving › Lifejacket/PFD (Type I)
Issued 25 September 2002 Resolved
Provide 3 additional adult lifejackets. The maximum number of passengers allowed is limited to 41 until this item is corrected. LEGACY COMPONENT DESC: Condition
Action required: 705 - Other - as specified
Due 25 October 2002
Resolved 30 September 2002
Resolution: New lifejackets provided.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 25 September 2002 Resolved
Mark life-ring with vessels name.
Action required: 705 - Other - as specified
Due 25 September 2002
Resolved 25 September 2002
Resolution: Corrected while inspection was in progress.
Lifesaving › Lifebuoys
Issued 25 September 2002 Resolved
Renew the retro-reflective tape on the life-ring.
Action required: 705 - Other - as specified
Due 25 September 2002
Resolved 25 September 2002
Resolution: Corrected while on board.
Documentation › Logs/Records
Issued 25 September 2002 Resolved
Provide a log or training record showing a record of training and emergency drills as per 46 CFR 185.524.
Action required: 705 - Other - as specified
Due 25 October 2002
Resolved 10 October 2002
Resolution: Provided training record with record of drills.
Construction/Loadline
Issued 16 January 2001 Resolved
Make vessel available for a sea trial check ride prior to carrying passengers. The sea trial check ride must be conducted under sail.
Condition: Unknown
Due 16 January 2001
Resolved 16 January 2001
Documentation
Issued 18 January 2000 Resolved
PROVIDE MARINE RADIO OPERATORS PERMIT.
Condition: Unknown
Due 20 January 2000
Resolved 26 January 2000
Unknown
Issued 18 January 2000 Resolved
LOG THE REQUIRED "EPIRB" TEST MONTHLY AND DRILLS EVER (3) MONTHS.
Condition: Unknown
Due 18 January 2000
Resolved 26 January 2000
Documentation
Issued 18 January 2000 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 18 January 2000
Resolved 18 January 2000
Documentation
Issued 18 January 2000 Resolved
PROVIDE PROOF OF PARTICIPATION WITH CHEMICAL TESTING PROGRAM.
Condition: Unknown
Due 20 January 2000
Resolved 26 January 2000
Unknown
Issued 3 June 1999 Resolved
NO MANUAL ACTUATION OF FIXED CO2 SYSTEM OUTSIDE SPACE.
Condition: Unknown
Due 15 June 1999
Resolved 18 June 1999
Unknown
Issued 3 June 1999 Resolved
THERE WERE VENT COVERS PROVIDED FOR NATURAL VENT DUCTS.
Condition: Unknown
Due 15 June 1999
Resolved 18 June 1999
Documentation
Issued 3 June 1999 Resolved
Provide a FCC Safety Radio Certificate.
Condition: Unknown
Due 3 June 1999
Resolved 3 June 1999
Lifesaving
Issued 3 June 1999 Resolved
Provide 12 adult PFDs. Vessel is restricted to the carriage of 36 total persons allowed.
Condition: Unknown
Due 3 June 1999
Resolved 3 June 1999
Construction/Loadline
Issued 16 February 1999 Resolved
vessel's 4th and 5th planks on the starboard side 7 feet forward of the base of the rudder to 17 feet forward of the base of the rudder are rotten and need to be replaced in kind.
Condition: Unknown
Due 16 February 1999
Resolved 26 February 1999
Construction/Loadline
Issued 16 February 1999 Resolved
The vessel's port qrt transum 3rd plank up is dry rotted and needs to be replaced.
Condition: Unknown
Due 16 February 1999
Resolved 26 February 1999
Lifesaving
Issued 24 January 1997 Resolved
Provide ring life buoy that meets the requirements of 46CFR180.70.
Condition: Unknown
Due 29 January 1997
Resolved 29 January 1997
Construction/Loadline
Issued 21 November 1995 Resolved
Perform underway drill to examine internal spaces as per CID Policy memo 2-94._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 November 1995
Resolved 21 November 1995
Lifesaving
Issued 18 January 1994 Resolved
SECURELY ATTACH COAST GUARD APPROVAL PLACARD FOR TEN PERSON BOUYANT APPARATUS.
Condition: Unknown
Due 18 January 1994
Resolved 18 January 1994
Navigation
Issued 18 January 1994 Resolved
PROVIDE CORRECTED CHART OF LOCAL OPERATING AREA #18746.
Condition: Unknown
Due 18 January 1994
Resolved 18 January 1994
Documentation
Issued 18 January 1994 Resolved
PROVIDE PROOF OF MARINE RADIO OPERATOR'S PERMIT FOR KEVIN MULLEN. VESSEL TOOPERATE ONLY WITH PERSON WORKING ON BOARD WITH VALID MARINE RADIO OPERATOR'S PERMIT.
Condition: Unknown
Due 18 January 1994
Resolved 18 January 1994
Navigation
Issued 18 January 1994 Resolved
PROVIDE UPDATED COMPASS DEVIATION CARD.
Condition: Unknown
Due 18 January 1994
Resolved 18 January 1994
Electrical
Issued 18 January 1994 Resolved
REMOVE WINGNUTS FROM BATTERY TERMINALS PER GOOD MARINE PRACTICE.
Condition: Unknown
Due 18 January 1994
Resolved 18 January 1994
Accommodation/Occupational Safety
Issued 18 January 1994 Resolved
PROVIDE MEANS OF SECURING OVERBOARD DISCHARGE VALVES (2) FOR MARINE SANITATION DEVICES.
Condition: Unknown
Due 18 January 1994
Resolved 18 January 1994
Lifesaving
Issued 18 January 1994 Resolved
PROVIDE FIVE ADULT TYPE I PFDS AND NUMBER OF PASSENGERS IS LIMITED TO 43 PERSONS UNTIL PFDS ARE PROVIDED.
Condition: Unknown
Due 18 January 1994
Resolved 18 January 1994
Navigation
Issued 18 January 1994 Resolved
PROVIDE UPDATED/CORRECTED COAST PILOT OF LOCAL AREA.
Condition: Unknown
Due 18 January 1994
Resolved 18 January 1994
Electrical
Issued 21 January 1993 Resolved
INSTALL AUDIBLE ALARM EQUIPMENT OR BLANK OFF SPACE IN PANEL BOX.
Condition: Unknown
Due 21 January 1993
Resolved 21 January 1993
Fire Fighting
Issued 21 January 1993 Resolved
PROVIDE EVIDENCE OF SERVICING ALL FIRE FIGHTING EQUIPMENT.
Condition: Unknown
Due 21 January 1993
Resolved 21 January 1993
Lifesaving
Issued 21 January 1993 Resolved
CONDUCT UNDERWAY EMERGENCY DRILLS IN PRESENCE OF USCG MARINE INSPECTOR.
Condition: Unknown
Due 21 January 1993
Resolved 21 January 1993
Lifesaving
Issued 21 January 1993 Resolved
PROVIDE ONE ADDITIONAL USCG APPROVED TYPE I ADULT PFD PRIOR TO CARRYING MORE THAN 47 ADULTS.
Condition: Unknown
Due 21 January 1993
Resolved 21 January 1993
Lifesaving
Issued 21 January 1993 Resolved
PROPERLY STENCIL ADULT AND CHILD LIFE PRESERVER STOWAGE COMPARTMENTS.
Condition: Unknown
Due 21 January 1993
Resolved 21 January 1993
Construction/Loadline
Issued 19 June 1992 Resolved
UNTWIST UPPER PORT BILGE LINE IN ENGINE ROOM.
Condition: Unknown
Due 19 June 1992
Resolved 19 June 1992
Construction/Loadline
Issued 19 June 1992 Resolved
INSTALL PORTLIGHT AND FIX CRACKED PORTLIGHT ON PORT SIDE OF LIVING SPACE.
Condition: Unknown
Due 19 June 1992
Resolved 19 June 1992
Construction/Loadline
Issued 19 June 1992 Resolved
RECAULK/TREAT MARKED AREAS OF HULL.
Condition: Unknown
Due 22 June 1992
Resolved 26 June 1992
Lifesaving
Issued 22 January 1992 Resolved
SPLICE SEA PAINTER TO BOUYANT APPARATUS (IN LIEU OF HAND KNOT).
Condition: Unknown
Due 22 January 1992
Resolved 22 January 1992
Unknown
Issued 22 January 1992 Resolved
CONDUCT AN UNDERWAY MAN-OVERBOARD DRILL AND A FIRE DRILL TO THE SATISFACTION OF AN ATTENDING COAST GUARD INSPECTOR.
Condition: Unknown
Due 22 January 1992
Resolved 22 January 1992
Electrical
Issued 22 January 1992 Resolved
PROVIDE DRIP SHIELD OVER BATTERY CHARGER IN ENGINE ROOM.
Condition: Unknown
Due 22 January 1992
Resolved 22 January 1992
Construction/Loadline
Issued 22 January 1992 Resolved
LABEL BILGE MANIFOLD VALVES FOR THE SPACE THEY ARE SERVING.
Condition: Unknown
Due 22 January 1992
Resolved 22 January 1992
Accommodation/Occupational Safety
Issued 22 January 1992 Resolved
LABEL MAIN CABIN EMERGENCY ESCAPE PER 46CFR185.30-15 IN MINIMUM 1-INCH LETTERS ON DECK.
Condition: Unknown
Due 22 January 1992
Resolved 22 January 1992
Lifesaving
Issued 22 January 1992 Resolved
PROVIDE REQUIRED SOUND SIGNAL DEVICE.
Condition: Unknown
Due 22 January 1992
Resolved 22 January 1992
Fire Fighting
Issued 22 January 1992 Resolved
PROVIDE PROPER BRACKETS AND MOUNT PORTABLE B-II FIRE EXTINGUISHERS IN FOCSLE AND MAIN CABIN.
Condition: Unknown
Due 22 January 1992
Resolved 22 January 1992
Fire Fighting
Issued 23 January 1991 Resolved
MOUNT B-I FIRE EXTINGUISHER AT HELM STATION.
Condition: Unknown
Due 23 January 1991
Resolved 23 January 1991
Unknown
Issued 23 January 1991 Resolved
PROVIDE DECK PLAN OF INTENDED BELOW DECK ARRANGEMENT.
Condition: Unknown
Due 23 January 1991
Resolved 23 January 1991
Lifesaving
Issued 23 January 1991 Resolved
PROPERLY SECURE RING BUOY WATER LIGHT TO RING BUOY AND MOUNT IT PROPERLY TOVESSEL.
Condition: Unknown
Due 23 January 1991
Resolved 23 January 1991
Navigation
Issued 23 January 1991 Resolved
PROVIDE PROPER ANCHOR LIGHT.
Condition: Unknown
Due 23 January 1991
Resolved 23 January 1991
Fire Fighting
Issued 23 January 1991 Resolved
INSTALL AUTOMATIC ENGINE SHUTDOWN TO BE ACTIVATED BY THE HALON FIRE EXTINGUISHER SYSTEM IN THE ENGINE ROOM.
Condition: Unknown
Due 23 January 1991
Resolved 23 January 1991
Lifesaving
Issued 23 January 1991 Resolved
LABEL ADULT AND CHILDREN LIFE PRESERVER STOWAGE AREAS.
Condition: Unknown
Due 23 January 1991
Resolved 23 January 1991
Unknown
Issued 23 January 1991 Resolved
LABEL EXTERIOR OF EMERGENCY ESCAPE "EMERGENCY ESCAPE, KEEP CLEAR"._x001C_
Condition: Unknown
Due 23 January 1991
Resolved 23 January 1991
Unknown
Issued 23 January 1991 Resolved
PROVIDE RADIO OPERATOR'S PERMIT.
Condition: Unknown
Due 23 January 1991
Resolved 23 January 1991
Construction/Loadline
Issued 23 January 1991 Resolved
PROVIDE SECURING DEVICE FOR ENGINE ROOM HATCH._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1991
Resolved 23 January 1991
Accommodation/Occupational Safety
Issued 23 January 1991 Resolved
INSTALL PROPER CABIN ACCESS LADDER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1991
Resolved 23 January 1991
Electrical
Issued 8 February 1988 Resolved
BATTERY BOXES IN NEED OF LINING.
Condition: Unknown
Due 8 February 1988
Resolved 8 February 1988
Electrical
Issued 8 February 1988 Resolved
BATTERIES IN BOX NEED PROPER INSTALLATION.
Condition: Unknown
Due 8 February 1988
Resolved 8 February 1988
Fire Fighting
Issued 8 February 1988 Resolved
FIRE EXTINGUISHER EXPIRED.
Condition: Unknown
Due 8 February 1988
Resolved 8 February 1988
Construction/Loadline
Issued 16 April 1985 Resolved
RENEW CLEVIS PIN BOTTOM TURNBUCKLE HEADSTAY.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985
Lifesaving
Issued 16 April 1985 Resolved
REPAIR CRACKS IN LIFE FLOATS.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985
Construction/Loadline
Issued 16 April 1985 Resolved
PROVIDE SCREEN ON VENTS FOR FUEL TANKS, (IN BRASS DECK WINCHES).
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985
Lifesaving
Issued 16 April 1985 Resolved
PROVIDE 2 ADDITIONAL ORANGE FLARES.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.