Records from 1984 to 1999. Most recent: inspection, 2 June 1999.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 23
2 June 1999
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 800590
17 April 1997
Hull Examination · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1418128
24 May 1996
Hull Examination · Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1360515
23 May 1995
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1434257
5 May 1994
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1374044
4 June 1993
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 831271
6 May 1993
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1141556
15 July 1992
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 943016
27 June 1991
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1220828
27 June 1991
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1352310
18 June 1991
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1194820
17 May 1991
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 916235
21 August 1990
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1220937
6 October 1989
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1022687
28 June 1989
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 891975
22 November 1988
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 897291
28 September 1988
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1193950
14 June 1988
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1352196
24 September 1987
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1000178
25 September 1986
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1008544
19 March 1986
Credit Drydock
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1305743
5 September 1985
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 987208
18 October 1984
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 975414
Lifesaving
Issued 15 July 1992
Resolved
Repair wooden skiff to be watertight _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 July 1992
Resolved 15 July 1992
Engineering
Issued 15 July 1992
Resolved
INSTALL A SPARK ARRESTER ON DRY EXHAUST SYSTEM
Condition: Unknown
Due 15 July 1992
Resolved 15 July 1992
Engineering
Issued 15 July 1992
Resolved
INSTALL A PROTECTIVE GUARD AROUND DRY EXHAUST PIPE IN BRIDGE
Condition: Unknown
Due 15 July 1992
Resolved 15 July 1992
Deck/Cargo
Issued 27 June 1991
Resolved
PROVIDE WARNING SIGN FOR STBD SIDE OF VSL AND RED PENENT (WARNING FLAG).
Condition: Unknown
Due 5 August 1991
Resolved 5 August 1991
Fire Fighting
Issued 27 June 1991
Resolved
PROVIDE SUPPORT BRACKET FOR CO2 BOTTLE IN BRIDGE AND RECHARGE BOTTLE OR PROVIDE STATEMENT FROM BAYSIDE THAT BOTTLE WEIGHT IS SATISFACTORY AND WHY
Condition: Unknown
Due 5 August 1991
Resolved 5 August 1991
Fire Fighting
Issued 27 June 1991
Resolved
PROVIDE BRACKETS AND MOUNT TWO B-II FIRE EXTINGUISHERS
Condition: Unknown
Due 5 August 1991
Resolved 5 August 1991
Engineering
Issued 27 June 1991
Resolved
TIGHTEN CUTLESS BEARING TO REDUCE LEAKAGE
Condition: Unknown
Due 5 August 1991
Resolved 5 August 1991
Construction/Loadline
Issued 27 June 1991
Resolved
DOUBLE CLAMP BILGE LINE IN ENGINE ROOM
Condition: Unknown
Due 5 August 1991
Resolved 5 August 1991
Construction/Loadline
Issued 27 June 1991
Resolved
REPLACE BILGE PIPE IN FWD AND AFT COMPARTMENTS WITH NON-COLLAPSABLE LINE
Condition: Unknown
Due 5 August 1991
Resolved 5 August 1991
Electrical
Issued 27 June 1991
Resolved
SHORE UP BATTERY TO PREVENT MOVEMENT
Condition: Unknown
Due 5 August 1991
Resolved 5 August 1991
Engineering
Issued 27 June 1991
Resolved
REPLACE ENGINE FUEL WITH HARD PIPPING
Condition: Unknown
Due 5 August 1991
Resolved 5 August 1991
Lifesaving
Issued 27 June 1991
Resolved
FIX OR REMOVE OVERHEAD LIGHT IN ENGINE ROOM
Condition: Unknown
Due 5 August 1991
Resolved 5 August 1991
Engineering
Issued 27 June 1991
Resolved
INSULATE ENGINE EXHAUST LINE
Condition: Unknown
Due 5 August 1991
Resolved 5 August 1991
Fire Fighting
Issued 28 June 1989
Resolved
PROVIDE ADDITIONAL B-II FIRE EXTINGUISHER TO MAKE TOTAL OF THREE.
Condition: Unknown
Due 28 June 1989
Resolved 28 June 1989
Fire Fighting
Issued 28 June 1989
Resolved
HAVE FIXED CO2 FIRE EXTINGUISHER SYSTEM SERVICED.
Condition: Unknown
Due 28 June 1989
Resolved 28 June 1989
Lifesaving
Issued 28 June 1989
Resolved
PROVIDE NEW PAINTERS FOR RING BUOYS.
Condition: Unknown
Due 28 June 1989
Resolved 28 June 1989
Lifesaving
Issued 28 June 1989
Resolved
STENCIL HULL OF WORK BOAT WITH NAME OF VESSEL.
Condition: Unknown
Due 28 June 1989
Resolved 28 June 1989
Fire Fighting
Issued 28 September 1988
Resolved
STENCIL NAME OF VESSEL ON FIRE AXE.
Condition: Unknown
Due 28 September 1988
Resolved 28 September 1988
Lifesaving
Issued 28 September 1988
Resolved
STENCIL VESSEL NAME AND CAPACITY ON RESCUE BOAT.
Condition: Unknown
Due 28 September 1988
Resolved 28 September 1988
Fire Fighting
Issued 28 September 1988
Resolved
HAVE FIRE EXTINGUISHERS SERVICED.
Condition: Unknown
Due 28 September 1988
Resolved 28 September 1988