A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 11
27 August 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 753436
26 August 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 209526
26 August 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 209527
26 August 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 753435
29 April 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 947125
17 May 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 939808
21 May 1987
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1334747
28 July 1986
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1294364
22 May 1986
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 988431
12 May 1986
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1303962
22 March 1985
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 988401
Lifesaving
Issued 21 May 1987
Resolved
PROVIDE TWO ADDITIONAL ADULT TYPE I PFD'S.
Condition: Unknown
Due 21 May 1987
Resolved 21 May 1987
Lifesaving
Issued 21 May 1987
Resolved
INDIVIDUALLY ATTACH EACH BUOYANT APPARATUS TO PAINTER.
Condition: Unknown
Due 21 May 1987
Resolved 21 May 1987
Electrical
Issued 21 May 1987
Resolved
INSTALL METAL WIRE HANGERS FOR WIRE RUNS IN MACHINERY SPACE.
Condition: Unknown
Due 21 May 1987
Resolved 21 May 1987
Navigation
Issued 21 May 1987
Resolved
BRING SIDELIGHTS AND MASTHEAD LIGHT IN COMPLIANCE WITH INTERNATIONAL RULES OF THE ROAD.
Condition: Unknown
Due 21 May 1987
Resolved 21 May 1987
Electrical
Issued 21 May 1987
Resolved
REPLACE SO CABLE RUNNING BETWEEN GENERATOR AND DISTRIBUTION PANEL WITH AN APPROVED CABLE.
Condition: Unknown
Due 21 May 1987
Resolved 21 May 1987
Unknown
Issued 28 July 1986
Resolved
PROVIDE PERMANENT REPAIR IN WAY OF TEMPORARY TO EMERGENCY FUEL SHUT-OFF IN ENGINE SPACE.
Condition: Unknown
Due 28 July 1986
Resolved 28 July 1986
Electrical
Issued 28 July 1986
Resolved
PROVIDE PLANS FOR REVIEW AND APPROVAL OF SHIP'S SERVICE GENERATOR. PLANS SHALL INCLUDE ALL GENERATOR SPECIFICATIONS, ALL ELECTRICAL DIAGRAMS, AND WIRING SPECIFICATIONS.
Condition: Unknown
Due 28 July 1986
Resolved 28 July 1986
Accommodation/Occupational Safety
Issued 22 May 1986
Resolved
EXTEND ONE VENT IN MACHINERY SPACE AS CLOSE AS PRACTICAL TO BILGE.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Navigation
Issued 22 May 1986
Resolved
REPLACE STERNLIGHT BULB.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Construction/Loadline
Issued 22 May 1986
Resolved
PROVIDE SECURING DEVICE FOR LAZARETTE HATCH.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Construction/Loadline
Issued 22 May 1986
Resolved
REMOVE DEADEND ELECTRICAL CABLE FROM COLLISION BULKHEAD. MAKE COLLISION BULKHEAD WATERTIGHT.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Electrical
Issued 22 May 1986
Resolved
PROVIDE LIGHT FIXTURES IN MACHINERY SPACE WITH GLOBES AND GUARDS.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Engineering
Issued 22 May 1986
Resolved
REPLACE EXISTING FLEXIBLE FUEL HOSE TO GENERATOR WITH COAST GUARD APPROVED EQUIPMENT.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986