MAURY USCG vessel records Sign in
← All vessels

LUNASEA

LUNASEA is a 1995 passenger vessel (inspected). The Coast Guard has recorded 37 inspections since 1995, most recently in November 2019, along with 131 deficiencies — 11 with no resolution recorded —.

Records from 1995 to 2019. Most recent: inspection, 6 November 2019.

Built
1995
Last inspected
6 November 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDL3005
418845
Flag
UNITED STATES
368117470
Maury page id
psix-418845

Inspections, by type

…with no type recorded1
…past their stated due date10
Years with a record 20 calendar years (1995–2019)
The 37 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it13 - Simplified, Net Ton
16 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDL3005MMSI 368117470 · active · compulsorily equipped · granted 18 October 2019, expires 18 October 2029 · licensed under a name not among this hull’s recorded names (not shown)
WDE9571MMSI 367418780 · expired · compulsorily equipped · granted 16 July 2009, cancelled 21 September 2019 · licensed under a name not among this hull’s recorded names (not shown)
WCZ6143MMSI not assigned · expired · voluntarily equipped · granted 7 January 2000, cancelled 13 March 2010 · licensed under a name not among this hull’s recorded names (not shown)
WCR2976MMSI not assigned · expired · compulsorily equipped · granted 2 May 1995, cancelled 2 July 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 37

6 November 2019 COI Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6846234
28 June 2018 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6458674
14 July 2016 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5940527
26 July 2012 COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4358276
15 June 2012 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4344577
20 July 2011 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4093527
16 September 2010 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3851618
22 July 2009 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3542730
9 June 2008 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3232473
8 November 2007 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3099157
13 April 2007 MARPOL Annex V Examination · Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2907394
3 April 2006 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2615683
14 March 2006 Annual Inspection · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2602111
31 January 2006 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2580912
14 March 2005 MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2309551
15 April 2004 Deficiency Check · Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2044310
14 January 2004 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1983868
17 December 2002 MARPOL Annex V Examination · COI Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1722025
28 January 2002 Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1481707
28 November 2001 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 771991
16 May 2001 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1429479
16 April 2001 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1066494
8 February 2001 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1429478
30 May 2000 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1050137
30 May 2000 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1053374
30 May 2000 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1058960
13 April 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1376119
14 December 1999 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1472360
10 December 1999 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1393310
29 June 1998 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 793250
17 April 1997 Hull Examination · MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1371763
24 September 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1355960
28 June 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1090631
23 May 1996 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1363655
1 June 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1184663
24 April 1995 MARPOL Annex V Examination · Initial Certification · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1360062
17 March 1995 Plan Review "T" Boat · Initial Construction-Excluding Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1443558

Deficiency record · 131

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 November 2019 No resolution recorded
Oil pressure gauge on port engine inoperable. Make repairs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2019 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 November 2019 No resolution recorded
Alternator on starboard engine inoperable. Make repairs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2019 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 November 2019 No resolution recorded
Lifebuoy, line and light installation not in accordance with regulation requirements. Make corrections to comply with requirement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2019 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 November 2019 No resolution recorded
Engine room fuel shut-off inoperable. Make repairs.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 20 November 2019 — due date passed with no resolution recorded
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 6 November 2019 No resolution recorded
Compass light inoperable. Make repairs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2019 — due date passed with no resolution recorded
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 6 November 2019 No resolution recorded
Radio broadcast placard has incorrect call sign. Make corrections.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2019 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 November 2019 No resolution recorded
Missing one required B-II fire extinguisher. Provide all required fire extinguishers.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 November 2019 No resolution recorded
Required fire extinguishers on vessel is not installed in approved brackets. Install correct brackets.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2019 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 November 2019 No resolution recorded
FCC Radiotelephony Safety Certificate not available. Get certificate.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2019 — due date passed with no resolution recorded
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 6 November 2019 No resolution recorded
Vessel has no ship log. Get log and record drills as required.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2019 — due date passed with no resolution recorded
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 June 2018 No resolution recorded
Renew both cutlass bearings.
Action required: 705 - Other - as specified
Due 2 August 2019 — due date passed with no resolution recorded
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 25 July 2012 Resolved
Fuel remote shut-off inoperable. Make repairs, test in presence of CGMI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2012
Resolved 27 July 2012
Resolution: Repaired, tested sat.
Engineering › Bilge Water Management System › Piping
Issued 25 July 2012 Resolved
Unable to get suction on any line of the bilge system. Make repairs, test in presence of CGMI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2012
Resolution: Made repairs tested sat.
Documentation › Markings/Placards › Capacity Marking
Issued 25 July 2012 Resolved
Upper deck max person capacity not marked correctly. Mark all access to upper deck with correct person capacity according to the new stability letter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2012
Resolution: Properly maked upper deck passenger capacity.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 25 July 2012 Resolved
Man Overboard and fire drills not conducted. Conduct drills in presence of CGMI.
Action required: 705 - Other - as specified
Due 17 August 2012
Resolved 4 September 2012
Resolution: Conducted man overboard, and fire drill.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 July 2012 Resolved
No machinery guard on generator belts. Provide belt guard.
Action required: 705 - Other - as specified
Due 17 August 2012
Resolved 4 September 2012
Resolution: Guards have been installed, SAT.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 July 2012 Resolved
Multiple dead end wires in tank compartment. Properly terminate unused wires.
Action required: 705 - Other - as specified
Due 17 August 2012
Resolved 13 August 2012
Resolution: All dead end wires have been properly terminated. all SAT.
Engineering › Fuel Oil Service System › Piping
Issued 25 July 2012 Resolved
Generator flex fuel lines are not double claped. Double clamp flex fuel lines on generator.
Action required: 705 - Other - as specified
Due 17 August 2012
Resolved 4 September 2012
Resolution: Flex fuel lines have been double clamped, all SAT.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 25 July 2012 Resolved
Water light on ring buoy inoperable and detachable clip frozen. Replace/repair both, test in presence of CGMI.
Action required: 705 - Other - as specified
Due 10 August 2012
Resolved 13 August 2012
Resolution: Repaired both, test in presence of CGMI.
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 25 July 2012 Resolved
Missing 2 distress signals. Provide distress signals as required for route.
Action required: 705 - Other - as specified
Due 10 August 2012
Resolved 13 August 2012
Resolution: Provided distress signals as required for route.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 25 July 2012 Resolved
No FCC Safety Radio Cert. Provide same.
Action required: 705 - Other - as specified
Due 17 August 2012
Resolved 28 August 2012
Resolution: Provided FCC Safety Radio Cert.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 25 July 2012 Resolved
Child life jackets stowed with adult ones. Provide separate stowage and mark location of child life jackets.
Action required: 705 - Other - as specified
Due 10 August 2012
Resolved 13 August 2012
Resolution: Provided separate stowage and marked location of child life jackets.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 25 July 2012 Resolved
Amp and Hertz meters inoperable on main switchboard. Repair/replace in kind.
Action required: 705 - Other - as specified
Due 17 August 2012
Resolved 4 September 2012
Resolution: meters have been renewed, all SAT.
Engineering › Bilge Water Management System › Piping
Issued 25 July 2012 Resolved
Main bilge system in inoperable due to generator failure. back-up DC system inoperable due to improper wiring and piping.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 September 2012
Resolution: Conducted operational test of vessel''s generator and bilge system. Generator was operating properly and bilge system operational test was sat.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 25 July 2012 Resolved
STBD bilge pump submerged in L/O. Excess L/O can be pumped OVBD if bilge system is operated. Repair L/O leak.
Action required: 705 - Other - as specified
Resolved 7 September 2012
Resolution: Bilges in the E/R were cleaned free of oil preventing the significant threat of discharge of oily water through automatic bilge pumps.
Engineering › Diesel Engine (auxiliary) › Pump, Positive Displacement
Issued 25 July 2012 Resolved
Generator cooling water pump failed. Repair and test.
Action required: 705 - Other - as specified
Resolved 7 September 2012
Resolution: The cooling water pump on the vessel''s generator was replaced with a new one. Operational test of the generator was sat.
Construction/Loadline › Hull › Weld
Issued 25 July 2012 Resolved
Identified a 2" hole at weld line on port side air vent to engine room. Repair hole.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 September 2012
Resolution: Hole was repaired with a piece of aluminum plate and 5200.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 20 July 2011 Resolved
Provide updated charts, light list, coast pilot for local area. 46cfr 184.420
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 July 2011
Resolved 25 July 2011
Resolution: Provided receipt for the purchase of coast pilot, light list and Eldridge publications.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 July 2011 Resolved
Provide approved first aid kit 46 cfr 184.710
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2011
Resolved 25 July 2011
Resolution: Provided receipt for uscg approved first aid kit.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 20 July 2011 Resolved
Provide log book for dily operations of vessel. 46cfr185.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2011
Resolved 25 July 2011
Resolution: Received receipt of new log book establish on vessel for cy 2011.
Operations/Management › Drug and Alcohol Testing › MRO Drug Free Certificates
Issued 16 September 2010 Resolved
VESSEL MUST PROVIDE DOCUMENTS TO SHOW CURRENT EMPLOYEE DAPI COMPLIANCE.
Due 23 September 2010
Resolved 17 September 2010
Resolution: VESSEL OWNER FAX PAPER WORK TO SECTOR.
Documentation › Certificates/Documents › FCC SSL
Issued 16 September 2010 Resolved
VESSEL MASTER MUST PROVIDE VALID MARINE OPERATOR'S PERMIT.
Due 23 September 2010
Resolved 17 September 2010
Resolution: FAX RECIEVED WITH COPY OF PERMIT.
Documentation › Markings/Placards › Capacity Marking
Issued 16 September 2010 Resolved
VESSEL MUST PROVIDE/STENCILE PASSENGER COUNT FOR UPPER DECK AS PER THE STABLITY LETTER.
Due 16 October 2010
Resolved 21 September 2010
Resolution: Vessel placed passenger count label for upper deck.
Lifesaving › Lifebuoys › Serviceable
Issued 16 September 2010 Resolved
Vessel must replace life buoy and corrosion resistant clip with new.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 September 2010
Resolved 23 September 2010
Resolution: Vessel purchased and installed new life buoy.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 September 2010 Resolved
Vessel must re-mount all loose rail stanchions on STB upper deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 September 2010
Resolution: Vessel re-mounted and added stantions to upper deck rail to better secure the starboard side.
Construction/Loadline › Structures › Door
Issued 22 July 2009 Resolved
Remove small door for access to the upper deck and replace with an acceptable means of securing.
Due 22 August 2009
Resolved 22 July 2009
Resolution: Door was removed and a chain was installed.
Engineering › Bilge Water Management System › Piping
Issued 22 July 2009 Resolved
Properly secure loose bilge piping IWO two (02) electrical bilge pumps located in the engine room, port side aft.
Action required: 705 - Other - as specified
Due 9 September 2009
Resolved 2 September 2009
Resolution: All piping associated with the electric bilge pumps was properly fastened.
Engineering › Sea-water System (primary cooling) › Piping
Issued 22 July 2009 Resolved
Properly secure wet exhaust cooling water intake hose servicing the port side MDE. Hose is currently being supported by wire ties attached to the overhead frame.
Action required: 705 - Other - as specified
Due 9 September 2009
Resolved 2 September 2009
Resolution: Cooling water intake flex hose was properly secured using mechanical means.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 22 July 2009 Resolved
Replace wasted flex hose IWO the wet exhaust on the port MDE just before the hydro lift muffler.
Action required: 705 - Other - as specified
Due 9 September 2009
Resolved 2 September 2009
Resolution: Flex hose was replaced with an approved hose.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 November 2007 Resolved
C/R Wasted deck rail port side fwd of pilot house.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 November 2007
Resolution: Rail replaced inkind.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 November 2007 Resolved
C/R waste/bent rail IWO STBD side aft corner
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 November 2007
Resolution: Made proper repairs to the satisfaction of the attending marine inspector.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 8 November 2007 Resolved
Repair loose step #3 IWO stairs leading up to upper deck
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 November 2007
Resolution: Made proper repairs to the satisfaction of the attending marine inspector.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 8 November 2007 Resolved
Repost missing support IWO aft STBD tarp located on upper deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 November 2007
Resolution: Made proper repairs to the satisfaction of the attending marine inspector.
Fire Fighting › Remote Fuel Shutoff › General
Issued 13 April 2007 Resolved
Properly install and prove proper operation of emergency fuel shutoff at tank.
Action required: 705 - Other - as specified
Due 20 April 2007
Resolved 23 April 2007
Resolution: Emergency fuel shutoff installed and operational.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 13 April 2007 Resolved
Replace cracked cooling water discharge hose on starboard engine.
Action required: 705 - Other - as specified
Due 20 April 2007
Resolved 23 April 2007
Resolution: Hose replaced.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 13 April 2007 Resolved
Clean bilge strainer in engine room.
Action required: 705 - Other - as specified
Due 20 April 2007
Resolved 23 April 2007
Resolution: Bilge strainer cleaned.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 14 March 2006 Resolved
Properly secure carpet at the bow embarkation area. Carpet comes up easily and is a safety hazard for passengers embarking/disembarking the vessel.
Due 1 April 2006
Resolved 3 April 2006
Construction/Loadline › Structures › Transverse Bulkhead
Issued 14 March 2006 Resolved
Replace PVC cap between tank void and forepeak (stbd side in tank void) with same material as bulkhead.
Due 1 April 2006
Resolved 3 April 2006
Resolution: PVC replaced with steel plug.
Accommodation/Occupational Safety › Heating › Piping
Issued 14 March 2006 Resolved
Replace valve handle for the raw water intake for vessel's heating system in tank void.
Due 1 May 2006
Resolved 3 April 2006
Resolution: Handle replaced with new.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 14 March 2006 Resolved
Update vessls publications to 2006 (Light List, Coast Pilot, Tide and Current Tables).
Due 1 April 2006
Resolved 3 April 2006
Resolution: Newe publications provide (Reeds purchased)
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 14 March 2005 Resolved
Replace the following pubs with current versions: US Coast Pilot, CG light list, Tide tables.
Due 21 March 2005
Resolved 22 March 2005
Resolution: New pubs O/B.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 March 2005 Resolved
Upper deck, stbd side, properly secure gate.
Due 21 March 2005
Resolved 22 March 2005
Resolution: Gate secured and clipped.
Electrical › Electrical Distribution System (service) › Cable
Issued 14 March 2005 Resolved
Upper deck, remove dead end wiring for old VHF arrangement.
Due 21 March 2005
Resolved 22 March 2005
Resolution: Wiring removed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 March 2005 Resolved
Upper deck, cap wiring for hailer w/ proper arrangement.
Due 21 March 2005
Resolved 22 March 2005
Resolution: Wiring removed.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 14 March 2005 Resolved
Port engine - secure leaking shaft which is leaking 1 drip per second.
Due 21 March 2005
Resolved 22 March 2005
Resolution: Shaft packing tightened. Coupling to be serviced next dry dock.
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 March 2005 Resolved
Stbd engine exhaust water hose needs double clamp
Due 21 March 2005
Resolved 22 March 2005
Resolution: Hose is double clamped.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 March 2005 Resolved
Stbd engine belt guard is loose. Secure.
Due 21 March 2005
Resolved 22 March 2005
Resolution: Guard is now secure.
Electrical › Lighting (service) › Lighting Fixture
Issued 14 March 2005 Resolved
Install light covers in E/R and fuel tank voids on all lights.
Due 21 March 2005
Resolved 22 March 2005
Resolution: Light covers installed.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 14 March 2005 Resolved
Install covers on all junction boxes in fuel tank void.
Due 21 March 2005
Resolved 22 March 2005
Resolution: Junction boxes installed.
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 March 2005 Resolved
Generator cooling water intake hose needs double clamp.
Due 21 March 2005
Resolved 22 March 2005
Resolution: Double clamp installed.
Documentation › Certificates/Documents
Issued 15 April 2004 Resolved
Provide proof of valid certificate of documentation. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Due 17 May 2004
Resolved 18 May 2004
Resolution: Cert of Documentation is valid.
Construction/Loadline › Structures
Issued 15 April 2004 Resolved
Replace PVC through hull fittings with steel (in void #1 to make fitting water tight). LEGACY COMPONENT DESC: Transverse Bulkhead
Due 17 May 2004
Resolved 18 May 2004
Resolution: Replaced through hull fitting with steel and made watertight.
Construction/Loadline › Markings
Issued 15 April 2004 Resolved
Paint hailing port on hull as per 46 CFR 67. LEGACY COMPONENT DESC: Vessel Name/Home Port
Due 17 May 2004
Resolved 18 May 2004
Resolution: Hailing port painted on hull.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 15 April 2004 Resolved
Install lagging on stbd MDE exhaust. LEGACY COMPONENT DESC: Piping (exhaust)
Due 17 May 2004
Resolved 18 May 2004
Resolution: Laffing installed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 15 April 2004 Resolved
Secure battery box covers to all batteries.
Due 17 May 2004
Resolved 15 April 2004
Resolution: Covers were installed prior to MI departure.
Stability › Unintentional Flooding
Issued 15 April 2004 Resolved
Double clamp all vital system piping in e/r.
Due 17 May 2004
Resolved 18 May 2004
Resolution: Piping double clamped.
Operations/Management › Navigation Safety
Issued 17 December 2002 Resolved
Provide current copy of Navigational Charts, U.S. Coast Pilot [name withheld] List, Tide Tables, Tide Current Tables and International Rules of the Road. LEGACY COMPONENT DESC: Carriage of Charts and Publications
Due 30 December 2002
Resolved 30 December 2002
Lifesaving › Hand Flares
Issued 17 December 2002 Resolved
Replace 3 Orange Day Smokes Signaling Devices. LEGACY COMPONENT DESC: Condition
Due 18 December 2002
Resolved 30 December 2002
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 December 2002 Resolved
Replace lanyard for waterlight on ring life bouy. Vsl is restricted from night time operations or limited visibility operations unil requirement is met
Due 17 December 2002
Resolved 17 December 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 17 December 2002 Resolved
Replace First Aid Kit with approved and current items/medications.
Condition: Improper/Lack of Maintenance
Due 30 December 2002
Resolved 30 December 2002
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 17 December 2002 Resolved
Replace B-II Fire Extinguisher and bracket on Upper Deck. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Due 30 December 2002
Resolved 30 December 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 17 December 2002 Resolved
Provide guard on aft end of Port Engine to cover belts. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Design Flaw
Due 30 December 2002
Resolved 30 December 2002
Engineering
Issued 17 December 2002 Resolved
Install double clamps on all vital systems with flexible hosing. LEGACY COMPONENT DESC: Vital Systems
Condition: Design Flaw
Due 30 December 2002
Resolved 30 December 2002
Documentation › Markings/Placards
Issued 17 December 2002 Resolved
Provide a MARPOL V placard. LEGACY COMPONENT DESC: Garbage Placard
Due 30 December 2002
Resolved 30 December 2002
Electrical › Electric Supply System (service)
Issued 17 December 2002 Resolved
Make proper repairs to electrical wiring on fresh water pump in tank space. LEGACY COMPONENT DESC: Cable
Due 30 December 2002
Resolved 30 December 2002
Electrical › Lighting (service)
Issued 28 January 2002 Resolved
Replace lights in engine room with approved UL lighting with covers LEGACY COMPONENT DESC: Lighting Fixture
Due 15 February 2002
Resolved 17 December 2002
Electrical › Electrical Distribution System (service)
Issued 28 January 2002 Resolved
Remove dead end wiring from engine room LEGACY COMPONENT DESC: Wiring
Due 15 February 2002
Resolved 17 December 2002
Engineering › Bilge Water Management System
Issued 28 January 2002 Resolved
Provide a positive stop closure valve to the RULE bilge pump overboard discharge. LEGACY COMPONENT DESC: Valve
Due 15 February 2002
Resolved 17 December 2002
Electrical
Issued 8 February 2001 Resolved
Provide a covered battery box for the generator start battery.
Condition: Unknown
Due 8 February 2001
Resolved 8 February 2001
Electrical
Issued 8 February 2001 Resolved
Remove deadended wiring from under the operating station through to the other end.
Condition: Unknown
Due 8 February 2001
Resolved 8 February 2001
Documentation
Issued 8 February 2001 Resolved
Provide proof of renewal of vessel Documentation.
Condition: Unknown
Due 9 February 2001
Resolved 9 February 2001
Lifesaving
Issued 8 February 2001 Resolved
Provide a public address system.
Condition: Unknown
Due 8 February 2001
Resolved 8 February 2001
Construction/Loadline
Issued 8 February 2001 Resolved
Provide bilge high level alarms with individual enunciators for the forepeak, engine room, and A/C space.
Condition: Unknown
Due 8 February 2001
Resolved 8 February 2001
Construction/Loadline
Issued 8 February 2001 Resolved
Provide a positive shutoff valve at the hull for the PVC manifolded Secondary Bilge Pumps.
Condition: Unknown
Due 8 February 2001
Resolved 8 February 2001
Documentation
Issued 8 February 2001 Resolved
Provide proof of renewal Drug and Alcohol Testing Consortium Membership.
Condition: Unknown
Due 8 February 2001
Resolved 8 February 2001
Navigation
Issued 8 February 2001 Resolved
Provide a signal strength meter for VHF radio.
Condition: Unknown
Due 8 February 2001
Resolved 8 February 2001
Documentation
Issued 8 February 2001 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 8 February 2001
Resolved 8 February 2001
Documentation
Issued 30 May 2000 Resolved
Vessel allowed to operate with 29 pax w/the following restrictions: disablenew heat & air installations, no pax upper deck, no canopy upper deck, no dead end wiring, mount and secure all fire extinguishers, vessel restrictedto 34th St/Restaurant transit only, w/ radio contact to observer each trip.
Condition: Unknown
Due 30 May 2000
Resolved 30 May 2000
Electrical
Issued 13 April 2000 Resolved
PRIOR TO OPERATING WITH MORE THAN 6 PASSENGERS, SUBMIT LOAD ANALYSIS CALCULATIONS FOR DETERMINING THE LOAD PLACED ON THE GENERATOR WITH THE NEWLY INSTALLED SYSTEMS, I.E. AIR CONDITIONING AND LIGHTING.
Condition: Unknown
Due 13 April 2000
Resolved 13 April 2000
Accommodation/Occupational Safety
Issued 13 April 2000 Resolved
PRIOR TO OPERATING WITH MORE THAN 6 PASSENGERS, SUBMIT PLANS FOR, AND RECEIVE APPROVAL ON, THE NEWLY INSTALLED AIR CONDITIONING AND HEATING UNITSTO INCLUDE DRAWINGS OF DUCTING, WIRING, PIPING, BULKHEAD PENETRATIONS AS WELL AS MAKE AND MODEL OF UNITS.
Condition: Unknown
Due 13 April 2000
Resolved 13 April 2000
Electrical
Issued 13 April 2000 Resolved
Prior to operating with more than 6 passengers, submit plans for, and receive approval on, the newly installed lights through out the vessel to include specifications on the wire, and fixtures used.
Condition: Unknown
Due 13 April 2000
Resolved 13 April 2000
Accommodation/Occupational Safety
Issued 13 April 2000 Resolved
Prior to operating with more than 6 passengers, submit plans for, and receive approval on, removing all seating from upper deck and changing the seating arrangement on main deck and to recalculate new passenger allowancein accordance with 46CFR176.113.
Condition: Unknown
Due 13 April 2000
Resolved 13 April 2000
Accommodation/Occupational Safety
Issued 13 April 2000 Resolved
Prior to operating with passengers on upper deck, submit plans and receive approval, on the newly installed rails and canopy on upper to ensure they are in accordance with 46CFR177.900
Condition: Unknown
Due 13 April 2000
Resolved 13 April 2000
Electrical
Issued 13 April 2000 Resolved
Remove or properly terminate, in a proper box, all dead end wire runs.
Condition: Unknown
Due 13 April 2000
Resolved 13 April 2000
Documentation
Issued 13 April 2000 Resolved
Prior to operating with more than 6 passengers, submit plans for, receive approval on, and conduct a simplified stability test in accordance with 46CFR178.330
Condition: Unknown
Due 13 April 2000
Resolved 13 April 2000
Navigation
Issued 13 April 2000 Resolved
Submit plans for newly installed navigation equipment to include make, model, power source, and wire schematics.
Condition: Unknown
Due 13 April 2000
Resolved 13 April 2000
Electrical
Issued 13 April 2000 Resolved
Prior to operating with more than 6 passengers, submit plans for, and receive approval on, the newly installed wiring system to include the powerpanel, switches and all wire used.
Condition: Unknown
Due 13 April 2000
Resolved 13 April 2000
Fire Fighting
Issued 13 April 2000 Resolved
Properly mount all portable fire extinguishers.
Condition: Unknown
Due 13 April 2000
Resolved 13 April 2000
Documentation
Issued 13 April 2000 Resolved
Make available all the vessels certificates and documentation for re- inspection
Condition: Unknown
Due 13 April 2000
Resolved 13 April 2000
Documentation
Issued 13 April 2000 Resolved
Due to the numerous ongoing modifications that are not in accordance with Coast Guard approved plans, your vessel is no longer in compliance with applicable federal laws and regulations. Therefore, you are required to surrender your certificate of inspection and all copies there of. SEE MINS.
Condition: Unknown
Due 13 April 2000
Resolved 13 April 2000
Accommodation/Occupational Safety
Issued 13 April 2000 Resolved
PROVE INSTALLATION OF NEW FURNITURE AND FURNISHINGS, ARE IN A ACCORDANCE WITH 46CFR177.115(B), 46CFR177.410(C)(5) AND 46CFR116.423 (SEE MINS).
Condition: Unknown
Due 13 April 2000
Resolved 13 April 2000
Deck/Cargo
Issued 14 December 1999 Resolved
Provide plate to cover old winch mount on upper deck.
Condition: Unknown
Due 3 January 2000
Resolved 3 January 2000
Engineering
Issued 14 December 1999 Resolved
Provide safety guard starboard main engine.
Condition: Unknown
Due 3 January 2000
Resolved 3 January 2000
Construction/Loadline
Issued 14 December 1999 Resolved
Replace bilge pipe in eng room IWO port rudder post.
Condition: Unknown
Due 3 January 2000
Resolved 3 January 2000
Lifesaving
Issued 14 December 1999 Resolved
Provide retroreflective tape on life rings.
Condition: Unknown
Due 3 January 2000
Resolved 3 January 2000
Accommodation/Occupational Safety
Issued 14 December 1999 Resolved
Repair vent on both sides to sewage system w/ goose necks and sceens.
Condition: Unknown
Due 3 January 2000
Resolved 3 January 2000
Documentation
Issued 14 December 1999 Resolved
Provide permanent copy of DOC.
Condition: Unknown
Due 3 January 2000
Resolved 3 January 2000
Documentation
Issued 14 December 1999 Resolved
Provide permanent copy of FCC Station Lic.
Condition: Unknown
Due 3 January 2000
Resolved 3 January 2000
Fire Fighting
Issued 14 December 1999 Resolved
Provide one more fire bucket for a total of 3.
Condition: Unknown
Due 3 January 2000
Resolved 3 January 2000
Lifesaving
Issued 14 December 1999 Resolved
Properly mount life jacket boxes on upper deck.
Condition: Unknown
Due 3 January 2000
Resolved 3 January 2000
Lifesaving
Issued 14 December 1999 Resolved
Mark upper deck w/ max capacity as per stability letter.
Condition: Unknown
Due 3 January 2000
Resolved 3 January 2000
Fire Fighting
Issued 14 December 1999 Resolved
Provide proper mounts for all portable fire extinguishers.
Condition: Unknown
Due 3 January 2000
Resolved 3 January 2000
Documentation
Issued 14 December 1999 Resolved
PROVIDE PASSENGER ORIENTATION BREIFING.
Condition: Unknown
Due 3 January 2000
Resolved 3 January 2000
Engineering
Issued 14 December 1999 Resolved
Double clamp raw water pump main engines.
Condition: Unknown
Due 3 January 2000
Resolved 3 January 2000
Navigation
Issued 14 December 1999 Resolved
ENSURE THAT ALL ATTACHMENT POINTS ON STEERING RAM HAVE DOUBLE NUTS.
Condition: Unknown
Due 3 January 2000
Resolved 3 January 2000
Fire Fighting
Issued 23 May 1996 Resolved
Have the rusted B-II fire extinguisher and the two B-I extinguishers serviced in accordance with the requirements of NFPA 10.
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996
Construction/Loadline
Issued 23 May 1996 Resolved
Remark the vessel's name on the port bow.
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996
Lifesaving
Issued 23 May 1996 Resolved
Conduct fire, flooding and man overboard drill in the presence of a Coast Guard Inspector using the normal vessel crew.
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996
Engineering
Issued 23 May 1996 Resolved
Reinstall the drive belt guards for the starboard main engine and the generator.
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996
Accommodation/Occupational Safety
Issued 24 April 1995 Resolved
Post sign at the bottom of the stair well, "UPPER DECK RESTRICTED TO 25 PERSONS".
Condition: Unknown
Due 24 April 1995
Resolved 24 April 1995
Construction/Loadline
Issued 24 April 1995 Resolved
Install hinges on the engine room access hatch in accordance with approved plan "Framing and Bulkhead S2" to make this space readily accessible.
Condition: Unknown
Due 24 April 1995
Resolved 24 April 1995
Accommodation/Occupational Safety
Issued 24 April 1995 Resolved
Provide metal trash can for the accommodation area.
Condition: Unknown
Due 24 April 1995
Resolved 24 April 1995
Construction/Loadline
Issued 24 April 1995 Resolved
The Myers fixed power driven bilge pump must be elevated as high as possible above the bilge level. Present location is unsatisfactory.
Condition: Unknown
Due 24 April 1995
Resolved 24 April 1995
Construction/Loadline
Issued 17 March 1995 Resolved
INSTALL 6 INCH COAMING IN ALL DOORWAYS.
Condition: Unknown
Due 17 March 1995
Resolved 17 March 1995
Construction/Loadline
Issued 17 March 1995 Resolved
INSTALL ZINC'S ON HULL.
Condition: Unknown
Due 17 March 1995
Resolved 17 March 1995
Engineering
Issued 17 March 1995 Resolved
INSTALL SUPPORTS FOR ALL ENGINE EXHAUST PIPES AND TUBES.
Condition: Unknown
Due 17 March 1995
Resolved 17 March 1995
Navigation
Issued 17 March 1995 Resolved
INSTALL MASTHEAD & ANCHOR LIGHTS.
Condition: Unknown
Due 17 March 1995
Resolved 17 March 1995
Accommodation/Occupational Safety
Issued 17 March 1995 Resolved
INSTALL UPPER DECK RAILS
Condition: Unknown
Due 17 March 1995
Resolved 17 March 1995
Accommodation/Occupational Safety
Issued 17 March 1995 Resolved
INSTALL FIXED SEATING
Condition: Unknown
Due 17 March 1995
Resolved 17 March 1995
Accommodation/Occupational Safety
Issued 17 March 1995 Resolved
INSTALL CEILING IN BOTH BATHROOMS
Condition: Unknown
Due 17 March 1995
Resolved 17 March 1995
Engineering
Issued 17 March 1995 Resolved
INSTALL RUDDERS & PROPELLERS
Condition: Unknown
Due 17 March 1995
Resolved 17 March 1995

Ownership record