ELIZABETH ANN

ELIZABETH ANN is a 1995 passenger vessel (inspected). The Coast Guard has recorded 56 inspections since 1995, most recently in April 2026, along with 31 deficiencies and 4 casualty investigations between 2005 and 2024.

Records from 1995 to 2026. Most recent: inspection, 22 April 2026.

Built
1995
Last inspected
22 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCP8821
418863
Flag
UNITED STATES
367011010
Maury page id
psix-418863

Inspections, by type

…with no type recorded12
Years with a record 26 calendar years (1995–2026)
The 56 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.0 ft × 19.0 ft × 6.0 ft
Registered tonnagegross 48 / net 39
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderARRO YACHTS · BIDDEFORD ME, UNITED STATES · built 1995
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPORT CLYDE, ME
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 10 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it39 - Simplified, Net Ton
48 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCP8821MMSI 367011010 · active · voluntarily equipped · granted 1 February 2025, expires 2 February 2035
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 56

22 April 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8354121
11 December 2025 Administrative Inspection · Drydock Extension
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8282180
20 November 2025 COI Inspection · Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8249366
8 January 2025 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8059873
27 July 2024 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7972166
30 January 2024 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7858625
18 January 2024 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7856078
21 December 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7841694
20 December 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7611706
20 December 2021 Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7370680
9 December 2021 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7366043
23 November 2020 COI Inspection · DAPI Audit
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7100350
15 January 2020 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6897873
17 December 2019 Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6875393
18 December 2018 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6601343
19 December 2017 DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6319232
14 December 2017 Drydock Exam · Administrative Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6319297
15 December 2016 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6059864
26 November 2015 Administrative Inspection · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5773577
12 November 2015 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5762501
6 December 2011 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4203790
29 July 2011 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4144303
30 November 2010 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3901454
18 March 2010 In-Service Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3701109
2 December 2008 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3371883
27 November 2007 COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3104293
1 November 2007 Hull Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3090449
6 April 2007 Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2902892
8 December 2005 Re-Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2546261
10 November 2005 Hull Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2532153
26 July 2005 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2487954
6 December 2004 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2252898
26 April 2004 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2052811
20 November 2003 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1949360
3 December 2002 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1713463
2 January 2002 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1474680
7 December 2001 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 773040
27 November 2001 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1076372
27 November 2001 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1477086
9 September 2001 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 164497
30 April 2001 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1448279
23 December 1999 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 813477
9 December 1999 COI Inspection · Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 812343
30 September 1999 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 179285
14 January 1999 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1413465
11 June 1998 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 110280
6 January 1998 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1467964
6 November 1997 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 775746
8 May 1997 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1099886
8 May 1997 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1101603
6 December 1996 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1188058
26 November 1996 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1392568
30 May 1996 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1086025
3 April 1996 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1078224
27 February 1996 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 884899
12 July 1995 Inclining Experiment · Initial Construction-Excluding Oversight · MARPOL Annex V Examination · COI Inspection · Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1367473

Deficiency record · 31

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 November 2025 Resolved
Repair replace retro tape on lifejackets as needed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2025
Resolved 13 January 2026
Resolution: Received pictures of newly replaced retro tape on lifejackets affected.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 November 2025 Resolved
Fire station on second deck needs valve repaired or replaced. Will not close all the way.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2025
Resolved 13 January 2026
Resolution: Received evidence of repaired valve.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 December 2021 Resolved
Electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Dead-end wires present on main deck, port and stbd sides near loading doors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2021
Resolved 18 January 2022
Resolution: Removed all dead-ended electrical wire.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 December 2021 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Sluice valves are not permitted in watertight bulkheads. Vessel's fixed bilge system unable to gain suction in lazerette.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2021
Resolved 18 January 2022
Resolution: Operates as designed.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 9 December 2021 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel did not have a DSC capable VHF radio.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2022
Resolved 18 January 2022
Resolution: Installed VHF-DSC radio.
Engineering › Bilge Water Management System › Hose
Issued 15 December 2016 Resolved
Dry rotted hose found on discharge for bilge/FF overboard. Replace hose in kind.
Due 29 December 2016
Resolved 3 January 2017
Resolution: Hose has been replaced in kind.
Stability › Unintentional Flooding › General
Issued 15 December 2016 Resolved
2. Vessel was found missing secondary securing device (lanyard) for exterior deck hatches as per 46CFR179.360(b). Provide securing device as required.
Due 29 December 2016
Resolved 3 January 2017
Resolution: Secondary securing device (lanyards were added).
Electrical › Electric Supply System (service) › Cable
Issued 30 November 2010 Resolved
Positive battery cable on port battery box was resting against the bottom of the 110-220 AC Panel and chaffing into the cable. 835: Install chaffing gear on port battery cable between bottom of 110/220 AC panel.
Condition: Improper/Lack of Maintenance
Due 30 December 2010
Resolved 8 March 2011
Electrical › Electric Supply System (service) › Cable
Issued 30 November 2010 Resolved
Some electrical cabels were identified that were not supported with plastic wire ties-non metallic. 835: Install Metallic wire supports on all electrical circuits in engine room.
Condition: Improper/Lack of Maintenance
Due 30 December 2010
Resolved 8 March 2011
Engineering › Sea-water System (primary cooling) › Piping
Issued 30 November 2010 Resolved
835: Install chaffing gear on raw water hose for bilge/fire pump system-stbd side of engine.
Condition: Improper/Lack of Maintenance
Due 30 December 2010
Resolved 8 March 2011
Engineering › Diesel Engine (propulsion-direct drive) › Pump, Positive Displacement
Issued 30 November 2010 Resolved
835: Install chaffing gear on hydraulic hoses on stbd side of main engine.
Condition: Improper/Lack of Maintenance
Due 30 December 2010
Resolved 8 March 2011
Lifesaving
Issued 27 November 2001 Resolved
PROVIDE WATERLIGHTS FOR THE 3 NEW BUOYANT APPARATUS
Condition: Unknown
Due 7 December 2001
Resolved 4 December 2001
Fire Fighting
Issued 27 November 2001 Resolved
SERVICE FIXED CO2 SYSTEM
Condition: Unknown
Due 7 December 2001
Resolved 4 December 2001
Lifesaving
Issued 27 November 2001 Resolved
INSTALL NEW EPIRB HYDROSTATIC RELEASE
Condition: Unknown
Due 7 December 2001
Resolved 4 December 2001
Lifesaving › Buoyant Apparatus
Issued 27 November 2001 Resolved
PROVIDE WATERLIGHTS FOR 3 NEW B/A'S
Condition: Improper/Lack of Maintenance
Due 27 November 2001
Resolved 7 December 2001
Fire Fighting
Issued 9 December 1999 Resolved
RAISE FIXED CO2 BOTTLE OFF OF DECK.
Condition: Unknown
Due 17 December 1999
Resolved 23 December 1999
Fire Fighting
Issued 9 December 1999 Resolved
WEIGH FIXED CO2 BOTTLE
Condition: Unknown
Due 17 December 1999
Resolved 23 December 1999
Fire Fighting
Issued 9 December 1999 Resolved
HYDRO-TEST FIXED CO2 BOTTLE
Condition: Unknown
Due 17 December 1999
Resolved 23 December 1999
Navigation
Issued 11 June 1998 Resolved
The pully belt parted, which led to the loss of steering. [name withheld] feelsthat the belt was defective, because the belt was replaced a couple of months ago. He plans on contacting the manufacturer concerning the defect. The belt parted were the ends are connected
Condition: Unknown
Due 15 November 2001
Resolved 4 December 2001
Accommodation/Occupational Safety
Issued 6 January 1998 Resolved
Make permanent replacement to the port side passenger area main deck window. Replacement is to be in kind, safety glass, and to the satisfactionof the attending Marine Inspector.
Condition: Unknown
Due 27 January 1998
Resolved 27 January 1998
Documentation
Issued 26 November 1996 Resolved
UNLESS THIS REQUIREMENT HAS BEEN CLEARED TO THE SATISFACTION OF AN ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 26 December 1996
Resolved 9 December 1996
Documentation
Issued 26 November 1996 Resolved
PROVIDE PROPER DOCUMENTATION OF FULLY COMPLIANT CHEMICAL TESTING PROGRAM FOR THE FOLLOWING DEFICIENCIES, 1)PROVIDE A SIGNED COPY OF THE CONTRACT, 2)PROVIDE A CREW LIST WITH DATES OF EMPLOYMENT. MARINE EMPLOYER IS NOT AUTHORIZED TO OPERATE AFTER 26DEC96 (THIRTY (30) DAYS FROM INSPECTION DATE)
Condition: Unknown
Due 26 December 1996
Resolved 9 December 1996
Lifesaving
Issued 27 February 1996 Resolved
PROVIDE/RELOCATE WATERLIGHT TO PILOT HOUSE RING BUOY
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Documentation
Issued 27 February 1996 Resolved
PROVIDE RENEWAL STICKER FOR DOCUMENT, NOT ATTACHED. VERIFIED RENEWED ON 2/27/96 VIA NAT VESSEL DOC CTR.
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Fire Fighting
Issued 27 February 1996 Resolved
SERVICE/WEIGH 100# FIXED FIRE EXT. BOTTLE/SYSTEM, VESSEL NOT ALLOWED TO CARRY PASSENGERS UNTIL CORRECTED.
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Engineering
Issued 27 February 1996 Resolved
RELOCATE EMERGENCY FUEL SHUT OFF TO PRECLUDE REACHING INTO THE ENGINEROOM TO OPERATE
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Accommodation/Occupational Safety
Issued 27 February 1996 Resolved
PROVIDE DOCUMENTATION ADDRESSING LACK OF VENTILLATION TO FWD VOID, AFT VOID,AND STEERING SPACE. REQ'D BY 46 CFR 177.20-1
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Fire Fighting
Issued 27 February 1996 Resolved
MOUNT SPARE 15# CO2 IN PILOT HOUSE, CURRENTLY ADRIFT, OR REMOVE FROM VESSEL
Condition: Unknown
Due 27 March 1996
Resolved 1 March 1996
Construction/Loadline
Issued 27 February 1996 Resolved
PROVIDE TAG LINE FOR FORWARD SCUTTLE
Condition: Unknown
Due 27 March 1996
Resolved 1 March 1996
Fire Fighting
Issued 27 February 1996 Resolved
PROVIDE DIAGRAM FOR CO2 SYSTEM
Condition: Unknown
Due 27 March 1996
Resolved 1 March 1996
Engineering
Issued 27 February 1996 Resolved
PROVIDE SAFETY VALVE AND PROOF OF AIR RECEIVER COMPLYING WITH ASME CODE, NOT TO BE USED UNTIL CORRECTED
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996

Casualty record · 4

26 July 2005Routine · role: Involved in a Marine Investigation (non-casualty) · 1 injured · activity 2487954
29 July 2011Routine · role: Involved in a Marine Casualty · activity 4144303
18 January 2024Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7856078
27 July 2024Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7972166
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.