MAURY USCG vessel records Sign in
← All vessels

PHOENIX

PHOENIX is a 1931 passenger vessel (inspected). The Coast Guard has recorded 59 inspections since 1985, most recently in September 2006, along with 57 deficiencies and 1 casualty investigation in 2006.

Records from 1985 to 2006. Most recent: inspection, 27 September 2006.

Built
1931
Last inspected
27 September 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCU3217
Flag
UNITED STATES
—
Maury page id
psix-41888

Inspections, by type

…with no type recorded6
Years with a record 22 calendar years (1985–2006)
The 59 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it0 - Dead Weight, Ton
112 - Regulatory (Subpart C or D), Gross Ton
104 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCU3217MMSI not assigned · expired · compulsorily equipped · granted 23 January 1997, cancelled 1 July 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 59

27 September 2006 Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2787860
12 July 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2710485
11 June 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2685084
3 May 2006 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2650163
8 November 2005 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2531018
26 September 2005 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2501847
3 June 2005 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2378427
5 January 2005 Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2269605
16 November 2004 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2242863
5 October 2004 MTSA Verification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2214353
29 July 2004 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2148964
30 June 2004 Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2116345
23 April 2004 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2050904
27 February 2004 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2014560
5 February 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2001251
22 October 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1930039
13 February 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1744437
5 September 2002 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1668832
30 April 2002 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1620453
19 November 2001 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1448375
20 April 2000 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1397403
2 September 1999 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1421730
22 July 1999 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1103002
15 October 1998 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1375523
9 April 1998 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1381208
23 October 1997 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1411553
12 September 1996 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1367936
2 May 1996 Inclining Experiment
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1083255
2 April 1996 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1407650
15 December 1995 Excursion Permit
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 883922
18 September 1995 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1394384
9 August 1995 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 881233
18 April 1995 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 854131
22 March 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1390016
5 October 1994 Hull Examination · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1463132
30 September 1994 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1179137
17 September 1993 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1415889
30 July 1993 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 847895
13 April 1993 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1143547
18 September 1992 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 934979
18 March 1992 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 950796
18 November 1991 Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 932361
18 September 1991 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 942342
26 April 1991 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1233728
17 September 1990 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 924650
9 April 1990 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 915951
26 September 1989 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 898579
18 September 1989 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 895880
8 November 1988 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1203958
19 September 1988 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1351444
11 May 1988 Damage Survey
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1348080
26 February 1988 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1029997
23 September 1987 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1009436
1 May 1987 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1024221
9 April 1987 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1329754
13 May 1986 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 998488
14 April 1986 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1294651
26 March 1986 Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1294648
20 May 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1291448

Deficiency record · 57

Electrical › Electrical Distribution System (service) › Wiring
Issued 8 November 2005 Resolved
Provide metallic fasteners to wiring every 24" throughout engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 December 2005
Resolved 14 December 2005
Resolution: Metallic fatsteners preovided.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 8 November 2005 Resolved
Exterminate insects in vicinity of CHT.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 December 2005
Resolved 14 December 2005
Resolution: Insects removed.
Construction/Loadline › Structures › Deck Plating
Issued 8 November 2005 Resolved
Scrape & treat angel hair in the portside overhead of the forward compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 December 2005
Resolved 14 December 2005
Resolution: Angel hair scaped and treated.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 8 November 2005 Resolved
Provide servicing for fixed CO2 system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 December 2005
Resolved 17 November 2005
Resolution: Serviced CO2 system.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 8 November 2005 Resolved
Repair and prove operation of all vent closures serving an area serviced by CO2 system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 December 2005
Resolved 17 November 2005
Resolution: Vent closures repaired.
Lifesaving › Hand Flares › Not on Board
Issued 8 November 2005 Resolved
Provide proper number of distress signals.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 December 2005
Resolved 17 November 2005
Resolution: Distress signals provided.
Lifesaving › Lifebuoys › Serviceable
Issued 8 November 2005 Resolved
Replace 2 ring buoys and refurbish a 3rd.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 December 2005
Resolved 17 November 2005
Resolution: Ring buoys replaced
Fire Fighting › Combustible Materials › Partial Bulkheads/Decks
Issued 8 November 2005 Resolved
Clean engine room bilges removing all oil and debris
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 December 2005
Resolved 17 November 2005
Resolution: Bilges cleaned
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 11 June 2004 Resolved
Submit long term repair/maintenance proposal for all viewing ports. Any construction must be pre-approved by LOSMS. (See special note 14 JUN 04) The vessel has many glass bottom viewing ports (boxes) inserted but not integral to the hull. The hull is wood and the boxes are steel. The boxes are deteriorating on the inside and must be removed and inspected (inside and out) during the next drydock.
Action required: 705 - Other - as specified
Due 26 July 2004
Resolved 27 July 2004
Resolution: Repair proposal submitted and is filed.
Construction/Loadline › Structures › Deck Plating
Issued 11 June 2004 Resolved
In Fwd and Aft voids: Provide additional access openings in deck, to allow for a more thorough inspection of bilges/hull.
Action required: 705 - Other - as specified
Due 26 July 2004
Resolved 27 July 2004
Resolution: Additional openings provided.
Documentation
Issued 19 November 2001 Resolved
Provide an emergency evacuation plan in accordance with 46 CFR 116.520.
Condition: Unknown
Due 19 December 2001
Resolved 30 April 2002
Electrical
Issued 19 November 2001 Resolved
Provide a cover for the open circuit breaker box in the upper engine room on the port side.
Condition: Unknown
Due 19 December 2001
Resolved 30 April 2002
Construction/Loadline
Issued 19 November 2001 Resolved
Mark bilge pump suction valves so they are readily identifiable.
Condition: Unknown
Due 19 December 2001
Resolved 30 April 2002
Fire Fighting
Issued 19 November 2001 Resolved
Provide a servicing report for the fixed CO2 fire system. This item must be completed before operating with passengers.
Condition: Unknown
Due 20 December 2001
Resolved 21 November 2001
Documentation
Issued 19 November 2001 Resolved
Provide a fire plan in accordance with 46 CFR 116.530.
Condition: Unknown
Due 19 December 2001
Resolved 30 April 2002
Engineering
Issued 19 November 2001 Resolved
Provide fuel tank vents to exterior of vessel.
Condition: Unknown
Due 19 December 2001
Resolved 30 April 2002
Lifesaving
Issued 19 November 2001 Resolved
Mark adult lifejacket storage lockers with correct number lifejackets.
Condition: Unknown
Due 19 December 2001
Resolved 30 April 2002
Construction/Loadline
Issued 20 April 2000 Resolved
SEAL HOLES IN BULKHEAD TO PREVENT ESCAPE OF CO2.
Condition: Unknown
Due 5 May 2000
Resolved 6 June 2000
Construction/Loadline
Issued 20 April 2000 Resolved
PROVIDE GAGING REPORT FOR TRANSVERSE WATERTIGHT BULKHEADS.
Condition: Unknown
Due 25 April 2000
Resolved 5 June 2000
Fire Fighting
Issued 20 April 2000 Resolved
PROVIDE MECHANICAL CLOSURES IN FLOOR VENTS TO REDUCE THE ESCAPE OF CO2.
Condition: Unknown
Due 5 May 2000
Resolved 6 June 2000
Construction/Loadline
Issued 20 April 2000 Resolved
PROVIDE OCMI WITH A PROPOSAL FOR THE PERMANENT REPAIR OF THE WASTED BULKHEAD MATERIAL IDENTIFIED BY GAGING REPORT.
Condition: Unknown
Due 20 April 2000
Resolved 20 April 2000
Fire Fighting
Issued 20 April 2000 Resolved
STENCIL VENT CLOSURES TO BE CLOSED WHEN FIXED CO2 IS RELEASED.
Condition: Unknown
Due 5 May 2000
Resolved 6 June 2000
Fire Fighting
Issued 20 April 2000 Resolved
READJUST CO2 DISCHARGE NOZZLES SO THE FLOW OF GAS ISN'T BLOCKED BY THE STRUCTURES IN THE ENGINEROOM.
Condition: Unknown
Due 5 May 2000
Resolved 6 June 2000
Unknown
Issued 2 September 1999 Resolved
Provide a written/documentation of the EAP per 46 CFR 16.401 prior to 02 OCT 99. Discovered during an audit on the chemical testing program._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 October 1999
Resolved 4 October 1999
Construction/Loadline
Issued 2 April 1996 Resolved
CONDUCT AN UNDERWAY INTERNAL HULL EXAM WITNESSED BY THE USCG.
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Lifesaving
Issued 18 September 1995 Resolved
Make repairs to, or replace, the 25 person buoyant apparatus. Repairs mustbe factory authorized. The number of persons on board is limited to 116 until adequate primary lifesaving is provided.
Condition: Unknown
Due 27 September 1995
Resolved 27 September 1995
Lifesaving
Issued 18 September 1995 Resolved
Provide six (6) adult Type 1 PFD's.
Condition: Unknown
Due 27 September 1995
Resolved 27 September 1995
Engineering
Issued 18 September 1995 Resolved
Test air received relief valves with a marine inspector or provide certification of testing from a qualified third party.
Condition: Unknown
Due 27 September 1995
Resolved 27 September 1995
Electrical
Issued 18 September 1995 Resolved
Line the battery box in the engine room with a durable acid resistant material.
Condition: Unknown
Due 27 September 1995
Resolved 27 September 1995
Electrical
Issued 18 September 1995 Resolved
Provide a single line electrical plan for all new electrical systems on board. These include the bar water pump, restroom water pump & passenger deck lighting system. Do not energize these electrical systems until they have been approved.
Condition: Unknown
Due 27 September 1995
Resolved 27 September 1995
Construction/Loadline
Issued 18 September 1995 Resolved
Provide strainers on all bilge suctions. Strainers must be at least three (3) times the cross sectional area of the pipe.
Condition: Unknown
Due 27 September 1995
Resolved 27 September 1995
Fire Fighting
Issued 18 September 1995 Resolved
Provide testing certification for the installed CO2 system.
Condition: Unknown
Due 27 September 1995
Resolved 27 September 1995
Lifesaving
Issued 22 March 1995 Resolved
ACQUIRE AND KEEP ONBOARD THE REQUIRED 200 (ADULT) LIFE PRESERVERS AND 20 (CHILD) LIFE PRESERVERS._x001C_
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Lifesaving
Issued 22 March 1995 Resolved
ACQUIRE AND KEEP ONBOARD THE REQUIRED 5 RING BUOYS.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Accommodation/Occupational Safety
Issued 17 September 1993 Resolved
PROVIDE MEANS OF LOCKING MSD OVERBOARD DISCHARGE VALVE.
Condition: Unknown
Due 17 September 1993
Resolved 17 September 1993
Lifesaving
Issued 17 September 1993 Resolved
PROVIDE ON BOARD FOUR ADDITIONAL ADULT PFD'S. PERSONS ON BOARD RESTRICTED TO 156 PENDING FULFILLING THIS REQUIREMENT.
Condition: Unknown
Due 17 September 1993
Resolved 17 September 1993
Documentation
Issued 17 September 1993 Resolved
PROVIDE COPIES OF RADIO OPERATOR PERMITS.
Condition: Unknown
Due 17 September 1993
Resolved 25 September 1993
Navigation
Issued 18 September 1992 Resolved
PROVIDE CHART OF OPERATING AREA, COAST PILOT, LIGHT LIST, NOTICE TO MARINERS, AND RULES OF THE ROAD.
Condition: Unknown
Due 18 September 1992
Resolved 18 September 1992
Navigation
Issued 18 September 1992 Resolved
PROVIDE DEVIATION TABLE FOR COMPASS.
Condition: Unknown
Due 18 September 1992
Resolved 18 September 1992
Documentation
Issued 18 March 1992 Resolved
PROVIDE FCC REQUIRED SAFETY RADIOTELEPHONE CERTIFICATE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 March 1992
Resolved 18 March 1992
Lifesaving
Issued 18 September 1991 Resolved
PROVIDE 2 ADDITIONAL ORANGE SMOKE DISTRESS SIGNALS.
Condition: Unknown
Due 18 September 1991
Resolved 18 September 1991
Documentation
Issued 18 September 1991 Resolved
PROVIDE A WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 18 September 1991
Resolved 18 September 1991
Lifesaving
Issued 18 September 1991 Resolved
PROVIDE 34 ADDITIONAL ADULT PFD'S. THE VESSEL IS RESTRICTED TO CARRYING 123 ADULT PASSENGERS UNTIL THIS REQUIREMENT IS MET.
Condition: Unknown
Due 18 September 1991
Resolved 18 September 1991
Fire Fighting
Issued 18 September 1991 Resolved
REPAIR THE BRACKET FOR THE B-I PORTABLE EXTINGUISHER IN THE PILOTHOUSE.
Condition: Unknown
Due 18 September 1991
Resolved 18 September 1991
Lifesaving
Issued 18 September 1991 Resolved
CONDUCT REGULAR TRAINING FOR EMERGENCIES FOR ALL CREW MEMBERS. PROPERLY LOG TRAINING IN THE SHIP'S LOG.
Condition: Unknown
Due 18 September 1991
Resolved 18 September 1991
Construction/Loadline
Issued 9 April 1990 Resolved
REPLACE GENERATOR OUTLET VALVE AND DOUBLE-CLAMP.
Condition: Unknown
Due 9 April 1990
Resolved 9 April 1990
Engineering
Issued 9 April 1990 Resolved
LABEL EMERGENCY FUEL SHUT-OFF STARBOARD AFT PASSENGER COMPARTMENT AND INSTALL PULL CORD FOR ACCESS.
Condition: Unknown
Due 9 April 1990
Resolved 9 April 1990
Construction/Loadline
Issued 9 April 1990 Resolved
SANDBLAST CLOGGED THROUGH-HULL STRAINERS.
Condition: Unknown
Due 9 April 1990
Resolved 9 April 1990
Fire Fighting
Issued 9 April 1990 Resolved
SERVICE ALL FIRE EXTINGUISHERS.
Condition: Unknown
Due 9 April 1990
Resolved 9 April 1990
Construction/Loadline
Issued 9 April 1990 Resolved
TREAT DRY ROT INBOARD KEELSON IN LAZARETTE.
Condition: Unknown
Due 9 April 1990
Resolved 9 April 1990
Lifesaving
Issued 19 September 1988 Resolved
PROVIDE 16 ADULT PFD'S.
Condition: Unknown
Due 19 September 1988
Resolved 19 September 1988
Fire Fighting
Issued 19 September 1988 Resolved
PROVIDE MOUNTING BRACKET FOR FIRE EXTINGUISHER LOCATED ON BOW.
Condition: Unknown
Due 19 September 1988
Resolved 19 September 1988
Engineering
Issued 19 September 1988 Resolved
DOUBLE CLAMP ALL COOLING WATER FLEXIBLE HOSES ON MAIN ENGINES.
Condition: Unknown
Due 19 September 1988
Resolved 19 September 1988
Electrical
Issued 19 September 1988 Resolved
PROPERLY SUPPORT ELECTRICAL WIRING IN OVERHEAD IN AFTER PASSENGER AREA AND ENGINE COMPARTMENT USING METALLIC SUPPORTS EVERY 24".
Condition: Unknown
Due 19 September 1988
Resolved 19 September 1988
Electrical
Issued 19 September 1988 Resolved
PROVIDE PROPER BLANK IN CIRCUIT PANEL.
Condition: Unknown
Due 19 September 1988
Resolved 19 September 1988
Fire Fighting
Issued 23 September 1987 Resolved
PROVIDE A SUITABLE METHOD OF CLOSURE FOR MAIN MACHINERY SPACE VENTILATION DUCTS (2) IAW 46 CFR 181.20-35.
Condition: Unknown
Due 23 September 1987
Resolved 23 September 1987
Fire Fighting
Issued 1 May 1987 Resolved
PROVIDE VENT OPENING CLOSURES FOR EACH OPENING OF THE STARBOARD FUEL TANK COMPARTMENTS.
Condition: Unknown
Due 1 May 1987
Resolved 1 May 1987

Casualty record · 1

11 June 2006Significant Marine Casualty · role: Acknowledged Pollution Source · serious marine incident, as classified · activity 2685084
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.