ATHENA is a 1948 passenger vessel (inspected). The Coast Guard has recorded 13 inspections since 1994, most recently in September 2006, along with 24 deficiencies and 1 operational control.

Records from 1994 to 2006. Most recent: inspection, 22 September 2006.

Built
1948
Last inspected
22 September 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

5383304 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
419009
Flag
PORTUGAL
—
Maury page id
psix-419009

Inspections, by type

…with no type recorded6
Years with a record 5 calendar years (1994–2006)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it14030 - Displacement, Ton
5931 - Convention (Subpart B), Net Ton
16144 - Convention (Subpart B), Gross Ton
15614 - Regulatory (Subpart C or D), Gross Ton
4700 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 13

22 September 2006 ISPS III Exam · PII Safety Exam · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2784379
20 September 2006 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2782679
19 September 2006 ISPS II Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2782419
14 April 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 440108
19 March 1997 Control Verification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1104835
18 March 1997 MARPOL Annex I Examination · Control Verification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1383473
27 January 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 387398
27 January 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 882756
27 October 1995 Administrative
Administrative · Marine Safety Center (MSC) · Activity 1186822
15 March 1995 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 376312
15 March 1995 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1357074
2 December 1994 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 864984
2 December 1994 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 865015

Deficiency record · 24

Engineering › Steering Gear System › Piping
Issued 22 September 2006 Resolved
Steering gear leaking oil, Class to examine the steering gear to ensure that it is suitable for service. Prior to departure.
Action required: 705 - Other - as specified
Due 22 September 2006
Resolved 23 September 2006
Resolution: Rcvd fax from Bureau Veritas on behalf of RINAVE stating two pieces of upper sealing rings were replaced. Steering gear was examined and satisfactory tested in operation from bridge and local control. No further leaks observed.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 22 September 2006 Resolved
Clean oil from the deck in the steering space, oil cam e from leaking steering gear. Corrected while onboard.
Action required: 705 - Other - as specified
Due 22 September 2006
Resolved 22 September 2006
Fire Fighting › Structural - A Class Divisions › Store-rooms
Issued 22 September 2006 Resolved
Crew has installed storeroom in restaurant deck #3, in way of frame 60-75. Class to approve the modification prior to the vessels departure from port or remove all stores.
Action required: 705 - Other - as specified
Due 22 September 2006
Resolved 23 September 2006
Resolution: Rcvd fax from Bureau Veritas on behalf of RINAVE stating the stores have been moved to the approved General Store Room, Deck 1, Fr. 145-164.
Engineering › Sea-water System (primary cooling) › Piping
Issued 22 September 2006 Resolved
Soft patch found on the sea water inlet for the #2 fresh water cooler for the diesel generator, repair to the satisfaction of Class.
Action required: 705 - Other - as specified
Due 22 October 2006
Resolved 23 September 2006
Resolution: Rcvd fax from Bureau Veritas on behalf of RINAVE stating a new sea water branch pipe was fabricated on board, visually examined and satisfactorily tested under working pressure.
Fire Fighting › Means of Escape › Blocked
Issued 22 September 2006 Resolved
Emergency exit out of the potable water tank space inner bottom frame 35 is locked. Remove the lock or re-label the exit direction out of the space. This exit leads to a store room.
Action required: 705 - Other - as specified
Due 22 October 2006
Resolved 23 September 2006
Resolution: Rcvd fax from BV on behalf of RINAVE stating the gate installed on the Port exit was dismantled in entirety. The compartment now has two emergency exits to the ER Store Room between C Deck - Deck 1 from which there is an evacuation route to Deck 1.
Fire Fighting
Issued 2 December 1994 Resolved
MARK ALL FIRE DOORS AND REPAIR CLOSURE INDICATORS AS NEEDED, DEMONSTRATE PROPER OPERATION OF SAME.
Condition: Unknown
Due 2 December 1994
Resolved 2 December 1994
Fire Fighting
Issued 2 December 1994 Resolved
REPAIR AND DEMONSTRATE SATISFACTORY OPERATION OF THE FIRE MAIN PRESSURE TANK AND SWITCH.
Condition: Unknown
Due 2 December 1994
Resolved 2 December 1994
Engineering
Issued 2 December 1994 Resolved
REMOVE EXCESS OIL AND WATER FROM BILGES IN ENGINEERING SPACES.
Condition: Unknown
Due 2 December 1994
Resolved 2 December 1994
Lifesaving
Issued 2 December 1994 Resolved
LABEL ALL LIFE PRESERVERS WITH THE VESSEL NAME AND PROVIDE LIGHTS FOR THOSEMISSING SAME IN STORAGE BOXES ON DECK.
Condition: Unknown
Due 2 December 1994
Resolved 2 December 1994
Lifesaving
Issued 2 December 1994 Resolved
CONDUCT A FIRE DRILL AND ABANDON SHIP DRILL IN THE PRESENCE OF A U.S. COASTGUARD INSPECTOR.
Condition: Unknown
Due 2 December 1994
Resolved 2 December 1994
Documentation
Issued 2 December 1994 Resolved
PROVIDE THE CERTIFICATE OF REGISTRY, SAFE MANNING CERTIFICATE AND CERTIFICATE OF FINANCIAL RESPONSIBILITY FOR EXAMINATION BY THE COAST GUARD.
Condition: Unknown
Due 2 December 1994
Resolved 2 December 1994
Fire Fighting
Issued 2 December 1994 Resolved
PLACE OPENING DEVICES "KEYS" AT ALL FIRE STATION BOX DOORS WHERE MISSING.
Condition: Unknown
Due 2 December 1994
Resolved 2 December 1994
Engineering
Issued 2 December 1994 Resolved
REMOVE TIE BACKS AND REPAIR REMOTE FUEL SHUT OFF VALVES AND DEMONSTRATE PROPER REMOTE OPERATION OF SAME.
Condition: Unknown
Due 2 December 1994
Resolved 2 December 1994
Fire Fighting
Issued 2 December 1994 Resolved
REPAIR FIRE DOOR AT BUNKERING STATION STBD SIDE, FIRE DOOR TO BRIDGE AND DOOR TA-01 TO ENSURE PROPER CLOSURE AND LATCHING.
Condition: Unknown
Due 2 December 1994
Resolved 2 December 1994
Engineering
Issued 2 December 1994 Resolved
REPAIR AND DEMONSTRATE SATISFACTORY OPERATION OF THE OILY/WATER SEPARATOR.
Condition: Unknown
Due 2 December 1994
Resolved 2 December 1994
Fire Fighting
Issued 2 December 1994 Resolved
PROPERLY INSTALL ONE FIRE HOSE RACK AT FIRE STATION AT THE AFT STARBOARD BULKHEAD OF THE STABILZER ROOM.
Condition: Unknown
Due 2 December 1994
Resolved 2 December 1994
Fire Fighting
Issued 2 December 1994 Resolved
MOUNT THE LOW VELOCITY FOG APPLICATORS IN ENGINEERING SPACES.
Condition: Unknown
Due 2 December 1994
Resolved 2 December 1994
Lifesaving
Issued 2 December 1994 Resolved
REMOVE ALL SHIPS STORES FROM ALL STAIRWAYS, CORRIDORS AND OTHER SPACES NOT DESIGNATED AS STOREROOMS AND PROPERLY STOW.
Condition: Unknown
Due 2 December 1994
Resolved 2 December 1994
Navigation
Issued 2 December 1994 Resolved
REPAIR GYRO COMPASS REPEATER, COMPLETE HYDRAULIC FLUID TANK INSTALLATION AND FILL AND CONDUCT STEERING GEAR TEST IN THE PRESENCE OF A CAOST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 2 December 1994
Resolved 2 December 1994
Construction/Loadline
Issued 2 December 1994 Resolved
POST POLLUTION PLACARD FOR OIL DISCHARGE, PROVIDE BLANK FLANGES FOR BUNKERING STATION, PROVIDE OIL TRANSFER PROCEDURES AND OIL RECORD BOOK IN ACCORDANCE WITH TITLE 33 C.F.R. 155 & 156.
Condition: Unknown
Due 2 December 1994
Resolved 2 December 1994
Documentation
Issued 2 December 1994 Resolved
PROVIDE GARBAGE DISPOSAL PLAN AND GARBAGE DISCHARGE PLACARDS.
Condition: Unknown
Due 2 December 1994
Resolved 2 December 1994
Electrical
Issued 2 December 1994 Resolved
REPAIR EMERGENCY LIGHTS IN SHAFT TUNNEL ESCAPE TRUNK AND IN CORRIDOR PORT SIDE CREW CABIN AREA #1 DECK.
Condition: Unknown
Due 2 December 1994
Resolved 2 December 1994
Lifesaving
Issued 2 December 1994 Resolved
PLACE ON BOARD THE TEN IMMERSION SUITES REQUIRED BY THE PASSENGER SHIP SAFETY CERTIFICATE AND MAKE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 2 December 1994
Resolved 2 December 1994
Documentation
Issued 2 December 1994 Resolved
MODIFY ALL FIRE SAFETY PLANS TO SHOW AS BUILT LOCATIONS OF FIRE AND SAFETY EQUIPMENT. HAVE CORRECT PLANS APPROVED BY FLAG STATE AND PLACE ON BOARD THE VESSEL.
Condition: Unknown
Due 2 December 1994
Resolved 2 December 1994

Ownership record