Inspection history · 20
10 November 2025
COI Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8266707
12 August 2024
Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7977715
28 July 2023
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7754729
15 April 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7594972
13 August 2019
DAPI Audit · COI Inspection · Administrative Inspection · Damage Survey
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6782808
13 August 2019
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6851299
4 August 2019
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6773553
4 August 2019
Damage Survey · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6781334
20 June 2019
Annual Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6719971
15 June 2019
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6716766
6 November 2018
Deficiency Check · Administrative Inspection · Damage Survey · Examination of Repairs
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6580659
24 August 2018
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6524374
23 August 2018
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6524182
21 July 2018
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6487900
21 July 2018
Administrative Inspection · Damage Survey
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6487959
9 July 2018
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6473838
21 May 2018
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6419454
7 November 2016
Drydock Exam · Administrative Inspection · Deficiency Check · Plan Review "T" Boat · DAPI Audit · Internal Structural Exam · Annual Inspection · Examination of Repairs
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6040618
26 September 2016
Administrative Inspection · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6009731
31 May 2016
DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5893642
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 November 2025
Resolved
This subpart summarizes the responsibilities of documented and licensed mariners, marine employers, MRO, SAP and other chemical testing service providers in 49 CFR part 40. Conduct a DAPI audit in accordance with chemical testing program compliance audit checklist.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2025
Resolved 4 December 2025
Resolution: DAPI certificate approved with MIS Trinity Cruise Company.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 August 2024
Resolved
A vessel must carry either a first aid kit approved under series 160.041 or a kit with equivalent contents and instructions. MI observed expired medications in first aid kit. Replace with approved kit within 7 days.
46 CFR 184.710
Action required: 705 - Other - as specified
Due 20 August 2024
Resolved 20 August 2024
Resolution: Received objective evidence of first aid being replaced with new kit.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 July 2023
Resolved
The following spaces must be equipped with a fire detection and alarm system of an approved type installed in accordance with 46 CFR part 76, except when a fixed-gas fire extinguishing system that is capable of automatic discharge upon heat detection is installed or when the space is manned: (1) A space containing propulsion machinery.
Vessel does not have fire detection in the machinery space. Vessels heat detectors for their fixed gas fire extinguishing system failed to operate and were not properly installed.
46 CFR 181.405
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 September 2023
Resolution: Vessel installed new heat detector heads in the engine compartment.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 July 2023
Resolved
Cylinders continuously in service without discharging shall be permitted to be retained in service for a maximum of 12 years from the date of the last hydrostatic test.
Vessels Fixed gas fire-extinguishing system cylinder is over due for a hydro static test.
46 CFR 175.600
46 CFR 147.60
NFPA 12
NFPA
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 September 2023
Resolution: Sea Safety installed new co2 bottle with good hydro date.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 28 July 2023
Resolved
ilge Alarm: A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating.
Vessel does not have an indicator light installed at the operating station indicating the Bilge Pump is operating.
46 CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 September 2023
Resolution: Vessel installed new bigle indicator lights.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 July 2023
Resolved
Engine Exhaust: Exhaust gas must not leak from the piping or any connections.
Vessels exhaust coupling at the turbo is deteriorated and the internal bands are exposed. Replace/ repair exhaust coupling.
46 CFR 182.430
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 September 2023
Resolution: Vessel installed new exhaust couplings.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 28 July 2023
Resolved
There must be a means of accurately determining the amount of fuel in each fuel tank either by sounding or by an installed marine type fuel gauge.
Vessels fuel gauge does no accurately display the amount of fuel in the tank.
46 CFR 182.445(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 November 2023
Resolution: Vessel submitted photographic evidence of fuel gauge working.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 July 2023
Resolved
Portable fire extinguishers other than wheeled extinguishers shall be installed using any of the following means. (1) Securely on a hanger intended for the extinguisher (2) In the bracket supplied by the extinguisher manufacture. (3) In a listed bracket approved for such purpose.
Fire extinguisher by the operating station was not installed in a manufactures approved bracket.
46 CFR 175.600
NFPA 10
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 September 2023
Resolution: Vessel mounted extingushier located at console.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 July 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to: (a) Provide services necessary for safety under normal and emergency conditions; (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; (c) Minimize accidental personnel contact with energized parts.
Vessel has multiple spliced wires throughout the vessel and wires not indicating which circuit they are protected by. Repair spliced wires and label circuits so they are readily and easily identifiable.
46 CFR 183.200
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 September 2023
Resolution: Vessel cleaned up wiring and removed dead end wires.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 July 2023
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: (7)Inspection of all interior spaces to ensure that they are adequately ventilated and drained.
De-water bilges in order for CGMI to inspect bilges.
46 CFR 176.802
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 September 2023
Resolution: Vessel dewatered spaces and a visual examination by MI was conducted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 January 2020
Resolved
Propulsion machinery must be suitable in type and design
for propulsion requirements of the hull in which it is
installed and capable of operating at constant marine
load under such requirements without exceeding its
designed limitations. Due to multiple shaft failures,
the vessel was previously required to submit detailed
plans to the Marine Safety Center for review and
comment. The Marine Safety Center came back stating
that the current arrangement does not meet ABYC or ABS
standards and that the current shaft is undersized given
the details provided. Vessel must either submit
revisions to previously submitted plans that show the
current shaft arrangement meets ABYC or ABS standards
and gain MSC approval or submit changes to their current
design and gain approval from the Marine Safety Center.
If changes are required to the current design, all
alterations will need to be overseen by an attending
marine inspector for installation and workmanship. No
passengers are allowed to be carried until this
deficiency is rectified.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 January 2020
Resolved 3 January 2024
Resolution: Uploaded MSC approval to documents tab in edit vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 August 2019
Resolved
Propulsion machinery must be suitable in type and design
for propulsion requirements of the hull in which it is
installed and capable of operating at constant marine
load under such requirements without exceeding its
designed limitations. Vessel's connection to
transmission via sheer pin failed causing vessel to
loose propulsion and maneuverability while underway with
passengers. Vessel must satisfactorily repair failed
sheer pin and test under operational loads in the
presence of an attending Marine Inspector. Vessel is
forbidden from carrying passengers until such time as
this deficiency is cleared.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 August 2019
Resolution: Vessel has satisfactorily replaced failed sheer pin and tested under operational loads in the presence of an attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 August 2019
Resolved
Propulsion machinery must be suitable in type and design
for propulsion requirements of the hull in which it is
installed and capable of operating at constant marine
load under such requirements without exceeding its
designed limitations. Vessel's crew is required to
visually inspect previous replaced sheer pin (beginning
today) once a week and record visual inspection in ships
log. Vessel must also submit detailed propulsion system
casualty/repair history and the following information
concerning the propulsion system (bill of materials,
design calculations, and engine specifications) to the
USCG Marine Safety Center (MSC) for review and comment.
Any recommendations returned from MSC will then be
reviewed by the O/O and Sector Buffalo Inspection Staff
for possible further action.
Action required: 705 - Other - as specified
Resolved 19 December 2019
Resolution: The vessel's O/O submitted calculations to the MSC and they returned that the size of the shaft is too small for ABYC or ABS standards. A new "no sail" deficiency will be written to not allow the vessel to operate until resolved.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 18 July 2019
Resolved
Gages to indicate oil pressure shall be provided for
propulsion engine. The gauge on the vessel is not
currently functioning. Provide proof of correction
within 14 days. 46 CFR 182.20-5 (b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2019
Resolved 31 July 2019
Resolution: The O/O replaced the gauge, which corrected the issue.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 July 2019
Resolved
The life ring on the stern of the vessel is wasted and
needs to be replaced or repaired. Replace or repair
within 14 days and provide proof to Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2019
Resolved 31 July 2019
Resolution: The life ring was replaced.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 18 July 2019
Resolved
Multiple items in the first-aid kit are expired.
Replace within 14 days and provide proof to Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2019
Resolved 31 July 2019
Resolution: The O/O replaced all the items in the med kit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 July 2019
Resolved
The battery on the water light that attaches to the ring
buoy is expired. Replace within 14 days and provide
proof to the Coast Guard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2019
Resolved 31 July 2019
Resolution: The O/O replaced the battery in the lifebuoy.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 November 2018
Resolved
During the test of the fixed fire extinguishing system,
the tech rep was not able to show a test of the 02 heat
activated devices nor provide manufacturers testing
procedures. Prove proper operation of 02 heat activated
devices to the satisfaction of a Coast Guard Marine
Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2019
Resolved 14 May 2019
Resolution: Corrected to the satisfaction of marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 November 2018
Resolved
No major repairs or alterations affecting the safety of the vessel shall be made without approval from the Office in Charge of Marine Inspections. All items listed below will require a written repair proposal submitted to our office within 07 days:
1. New Shaft Arrangement
2. Planking on the Port Side
3. All repairs of frames on the port side.
4. Transom caulking issues to include bottom planking
and exhaust piping.
5. Frames in the area forward of the collision
bulkhead.
6. Collision bulkhead repair.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 December 2018
Resolved 7 May 2019
Resolution: Cleared to the satisfaction of attending marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 July 2018
Resolved
Received notification from the owner/operator that
during a trip their shaft sheared off from the
transmission and dropped into the bilge rendering the
vessel with no means of propulsion. All machinery must
be installed and maintained in such a manner as to
afford adequate protection against machinery failure.
Provide the specifications for the new shaft that will
be installed and prove proper operation to Coast Guard
Marine Inspector prior to carrying passenger.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2018
Resolved 25 July 2018
Resolution: Observed new sectional shaft portion (304 SS) coming off of reduction gear. Shaft, coupling, u-joint connection, shear pin, key and keyway were installed and appeared in good order. Future permanent fix pending.
Stability › Weathertight Integrity › General
Issued 19 June 2018
Resolved
On the 19Jun2018 Deficiency Check, we discovered water in the bilge that appeared to be running steadily from aft to forward collecting near the bilge pump under the operating station. We were not able to determine if the water was coming from rain water into the aft hatch or from the hull. The bilge needs to be kept dry and monitored over the next 30 days to determine if further actions needs to be taken.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2018
Resolved 25 July 2018
Resolution: While attending vessel for damage survey related to shaft casualty, the Marine Inspector verifed replacement and relocation of bilge pump.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 7 June 2018
Resolved
The emergency procedures for the vessel to be written
for that specific vessel's operation. The man overboard
procedures state that they will put a crewmember in the water and the fire drill procedures state the Coast Guard would be called in an emergency. Both of these are not accurate to the vessel's operation. Update to reflect accurate procedures.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 19 June 2018
Resolution: Vessel O/O updated emergency procedures.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 5 June 2018
Resolved
At least one ring life buoy must be fitted with a lifeline. The 60ft line attached to the ring life buoy is wasted and needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2018
Resolved 19 June 2018
Resolution: The vessel's O/O replaced the 60ft lifeline on the ring life buoy.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 June 2018
Resolved
A vessel must carry one floating waterlight. The battery on the waterlight was marked 2016. The battery needs to be replaced annually.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 19 June 2018
Resolution: The vessel's O/O replaced the battery in the floating waterlight.
Electrical › Lighting (service) › Conductor
Issued 5 June 2018
Resolved
Electrical equipment exposed to the weather must be watertight. Wires going to the stern light were made with an unauthorized splice. Wires need to be spliced in accordance with 46 CFR 183.340 (g)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 19 June 2018
Resolution: The vessel's O/O removed the splice and ran the wires as required.
Personnel › Certificates/Documents/Licenses › Certificate, First Aid Course Completion
Issued 5 June 2018
Resolved
The vessel's crew was not able to demonstrate the ability or knowledge to render basic medical treatment during a man overboard drill. The crew needs training to be able to provide this treatment.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 22 July 2018
Resolution: Received an email from the O/O with first aid certificates for all crewmembers.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 5 June 2018
Resolved
The crew should be trained prior to getting underway for
emergency situations to include responding to a fire. The vessel's crew was not able to explain how to operate the fuel shut offs. Provide training to all crew members prior to getting underway.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 7 June 2018
Resolved 19 June 2018
Resolution: The vessel's O/O provided training to crew members and their knowledge was tested by attending Marine Inspector.
Navigation › Piloting/Steering › US Coast Pilot
Issued 5 June 2018
Resolved
Provide the most updated copies of charts, Coast Pilot and Light List on the vessel for the waters operated.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 19 June 2018
Resolution: The vessel O/O provided updated copies of all navigation publications.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 June 2018
Resolved
The first aid kit on board the vessel contained expired aspirin and neosporin. The kit needs to be updated with new items.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 19 June 2018
Resolution: The vessel O/O updated their first aid kit.
Stability › Watertight Integrity › General
Issued 5 June 2018
Resolved
A small amount of water is coming in through the deck on
the stern. Water was found in the port aft corner of the transom. Find source of water intrusion and correct.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 19 June 2018
Resolution: The vessel O/O caulked the deck on the stern to eliminate the water intrusion.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 15 May 2017
Resolved
Provide adequate storage for life jackets, demonstration required.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 19 May 2017
Resolution: Center wooden slats removed and demonstration of retrieval sat.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 15 May 2017
Resolved
Replace five (05) adult type I life jackets, vessel is limited to 45 passengers until corrected.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2017
Resolved 19 May 2017
Resolution: Additional five (05) adult type I's provided with appropriate markings.
Stability › Watertight Integrity › General
Issued 15 May 2017
Resolved
Reduce excessive leaking from shaft.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2017
Resolved 19 May 2017
Resolution: Witnessed satisfactory corrective measures limiting the ingress of water.
Fire Fighting › Fire Bucket › Stenciling
Issued 31 May 2016
Resolved
Mark fire buckets as required by cite.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2016
Resolved 31 May 2016
Resolution: Required marking completed prior to MI's departure.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 31 May 2016
Resolved
Remove from vessel & destroy 3 adult & 1 child life jackets found unsatisfactory condition.
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 31 May 2016
Resolution: Inspection provided sufficient quantity of jackets on board. Condemned jackets destroyed prior to MI's departure.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 31 May 2016
Resolved
Provide corrosion resistant clip for 3' lanyard for life buoy. When stowed the line must be attached around the body of the ring buoy.
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 17 June 2016
Resolution: Attended vessel and witnessing satisfactory installation of clip and lanyard.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 31 May 2016
Resolved
Provide battery for water light with current expiration date or replace battery annually.
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 31 May 2016
Resolution: New battery with current expiration date installed prior to MI's departure.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 31 May 2016
Resolved
e-water all spaces & maintain dry & free of oil. Verification by Masters required prior to each daily operation. Entry in vessels log shall be completed.
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 31 May 2016
Resolution: Oil water mixture removed from bilge with main space & water from forward void pumped. Space inspected with no further water intrusion identified. Masters verification of spaces required with finding to be logged prior to each daily operation.
Construction/Loadline › Hull › Bottom Plating
Issued 31 May 2016
Resolved
Identify leaking seams in mid-body port side & transom; inspect wood & replace planks or repack as appropriate to make vessel watertight. Make vessel available for in water internal inspection prior to 2017 operating season.
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 7 May 2019
Resolution: Open Deficiency from previous drydock. Cleared to the satisfaction of marine inspector.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 31 May 2016
Resolved
Provide annual servicing record for portable & fixed fire extinguishers.
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 1 June 2016
Resolution: Annual servicing report provided.