Records from 1995 to 2023. Most recent: inspection, 13 November 2023.
Inspection history · 41
13 November 2023
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7823830
21 October 2020
PSC A
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7078903
11 October 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7075298
10 October 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7074927
1 February 2019
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6618463
31 January 2019
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6618273
8 October 2018
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6556965
6 October 2018
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6554041
12 February 2018
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6353819
29 January 2018
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6345195
9 November 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6038380
9 November 2016
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6038412
9 November 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6038601
18 July 2016
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5945060
10 July 2016
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5934852
17 February 2012
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4242867
2 August 2011
Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4102535
22 October 2007
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3084552
10 October 2007
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3070173
10 October 2007
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3076609
7 October 2007
PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3074774
8 June 2006
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2673698
1 March 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2594143
1 March 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2594312
6 September 2005
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2485872
3 September 2005
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2482739
22 August 2004
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2175920
17 August 2004
Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2168648
29 May 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2081703
25 May 2004
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2077868
22 May 2004
ISPS II Exam · Ballast Water Examination · Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2074880
21 May 2004
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2074282
30 October 2001
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 295128
25 September 2000
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 25211
22 September 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 282451
27 August 1999
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 432135
24 August 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 407173
18 September 1995
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 450729
23 March 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 497302
22 March 1995
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 376278
2 March 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 376481
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 21 October 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Ships emergency generator cooling radiator found with wastage and leaking fluid.
SOLAS 74 (88 Protocol) I/11
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 October 2020
Resolved 21 October 2020
Resolution: Class survey statement provided and reviewed. Condition of class issued.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 October 2020
Resolved
All the steering gear components and the rudder stock shall be of sound and reliable constructions to the satisfaction of the Administration. #1 Steering gear pump found excessively leaking/spraying during steering gear test with flange bolts loose.
SOLAS 74 II-1/29
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2020
Resolved 21 October 2020
Resolution: Class survey statement provided to attest to ships crew making repairs to hydraulic system.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 21 October 2020
Resolved
Each operation described in paragraph 2 of this regulation shall be fully recorded without delay in the Oil Record Book Part I, so that all entries in the book appropriate to that operation are completed.
IOPP Supplement, section 3.1 (Oily Bilge Tank) states 10.84 m3 capacity. Upon inspection of ORB, it was noted that capacities were being recorded as 15.3m3.
MARPOL 73/78 I/4
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2020
Resolved 21 October 2020
Resolution: Class undersigned, re-issued the IOPP Supplement to
correctly reflect the Oily Bilge Tank capacity @ 15.84m3.
Steering gear
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 February 2019
Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any dangers to persons onboard. PSCO obserbed 1,2 and 3 generators having multiple oil leaks which is pooling oil under generators. Main engine fuel pump number 4 is leaking excessivly and running down main. these items pose a fire hazard and create undue risk to the crew.
CITE: 74SOLAS(04)II-I/26.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 February 2019
Resolved 1 February 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 February 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulation to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO observed an excessive cooling water leak on main engine number 1 cylinder head pipe flange. PSCO found a temp patch on seawater cooling pipe on heat exchanger and a rubber pipe patch on boiler feedwater pump piping.
CITE: 74SOLAS(04)II-I/11.(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 February 2019
Resolved 1 February 2019
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 February 2019
Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons onboard. PSCO found oil pooling in combing around steering gear and pumps.
Cite: 74SOLAS(04)II/I/26.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 February 2019
Resolved 1 February 2019
Resolution: Hydraulic oil was cleaned up and steering tested with no noticible leaks found.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 2 February 2018
Resolved
1730- Oily Water Separating Equipment- Oil filtering equipment shall be provided with arrangements to ensure that any discharge of oily mixtures in automatically stopped when the oil content of the effluent exceeds 15 ppm. OWS Flow Meter Sensor was not operational. The sensor controls the 3 way valve which directs oily water above 15ppm to bilge holding tank. Chief Engineer made appropriate entries in ORB and tagged out the OWS. Parts have been ordered. Vessel has enough bilge tank capacity to make the voyage to Baltimore Safely. MARPOL 73/78 2011(Cons) Annex I Reg. 14.7- 16a
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 12 February 2018
Lifesaving › Launching Appliances › Falls
Issued 2 February 2018
Resolved
0615- Rescue Boats - Launching and embarkation appliances for rescue boats shall comply with section 6.1 of the code. A launching appliance shall not depend on any means other than gravity or stored mechanical power. Rescue boat Hydraulic Accumulator is inoperable.- 74 SOLAS (04Cons)CHIII/Reg 17.3/LSA Code CH VI 6.1.1.3- 16a
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 12 February 2018
Resolution: SECTOR NEW YORK RECEIVED CLASS REPORT ATTESTING TO THE RECTIFICATION OF THE FOLLOWING DEFICIENCIES
Construction/Loadline › Hull › Side Shell
Issued 9 November 2016
Resolved
Vessel sustained a 20' by 24"+ tear to the starboard aft side shell IWO 10m draft mark. Permanent repairs to be complete to the satisfaction of class.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 December 2016
Resolution: Repairs completed to satisfaction of class & Coast Guard. Vessel authorized to be placed back into service. [name withheld]
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 10 October 2007
Resolved
0725 - VSL LOW PRESSURE CO2 FLOODING SYSTEM IS INOPERATIVE. VSL CAN NOT SAFELY EXTINGUISH FIRES IN ENGINE ROOM OR LARGE AREA (VSL CARRIES CARGO-AUTO) USING FIXED CO2 SYSTEM. SOLAS 74/78(2004) II-2/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2007
Resolution: Vessel repaired to operating status with conditions of class imposed for further repair of the system NLT 14 Nov 07. Ref DNV report.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 10 October 2007
Resolved
0740 - VSL EMERGENCY FIRE PUMP CAN ONLY BE MADE TO SHOW ADEQUATE PRESSURE FOR FIRE FIGHTING. WHEN FIRST PRIMED USING ONE OF THE VSL'S MAIN FIRE PUMPS THEN ISOLATING THE EMERGENCY FIRE PUMP FROM THE MACHINERY SPACE. F/F WATER CANT BE MADE IMMEDIATELY READY FOR EMERGENCY FIRE PUMP AND ONCE MADE READY CANT BE USED TO SUPPLY F/F WATER TO ENGINE ROOM AS REQUIRED. SOLAS 74/78(2004) II-/14.2.1.2
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2007
Resolution: Class attested to proper operation of emergency fire pump. see attached DNV report.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 10 October 2007
Resolved
2545 - VSL HAS BEEN AWARE OF CO2 SYSTEM DEFICIENCIES SINCE SEPT 27 (ATLEAST). VSL HAS BEEN RCVING ALARMS ("CO2 ALARM SYSTEM FAILURE") SINCE OCT 2 AND LIKELY EARLIER DATING BACK TO SEPT 27 OR EVEN EARLIER. VSL DID NOT REPORT THIS TO VSL COMPANY AS REQUIRED BY SECTION 4.1.1. SOLAS 74/78(2004) IX/3 & ISM 9.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2007
Resolution: Vessel was issued major non-conformity which was later downgraded. see attached documentation.
Fire Fighting › Fire Pumps › Power Source
Issued 10 October 2007
Resolved
VSL CREW APPEARED AWARE OF EMERGENCY FIRE PUMP DISCREPANCY AND WERE FAMILIAR WITH TECHNIQUE USED TO DEMONSTRATE APPEARANCE OF SATISFACTORY FIRE MAIN PRESSURE FROM EMERGENCY FIRE PUMP AND INDICATE THAT THE PUMP WAS RECENTLY REPAIRED. REQUEST RO AUDIT VSL ISM IMPLEMENTATION. SOLAS 74/78(2004) IX/3 & ISM Code 9.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2007
Resolution: Vessel submitted corrective action plan to the satisfaction of class/RO/RSO (DNV). see attached documentation.
Deck/Cargo › Ballast › Tank
Issued 10 October 2007
Resolved
0940 - #4 STBD BALLAST TANK IS HOLED APT SIDE OF FR91. TEMP REPAIR OF EPOXY/CEMENT MATERIAL APPLIED PARTIALLY EFFECTIVE AND HOLDING LEAK FROM BALLAST TANK TO APPRX 1 DRIP/SEC. EARLIER REPAIRS CONSISTING OF DOUBLER PLATES ALSO IN SAME AREA. CREW AWARE OF CONDITION. REQUEST RO AUDIT VSL ISM IMPELMENTATION AND ATTEST TO INTEGRITY OF BALLAST TANK AND REPAIRS THERE TO. SOLAS 74/78(2004) IX/3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2007
Resolution: Vessel removed concrete patch and welded doubler plate. condition of class imposed for permanant repairs not later than 14 Nov 07.
Engineering › Freshwater System (air cooling) › Power Supply
Issued 10 October 2007
Resolved
VSL COOLING FRESH WATER SYSTEM IS NOT BEING MAINTAINED IN ACCORDANCE WITH MANUFACTURERS DESIGN. REQUEST RO AUDIT ISM IMPLEMEMTATION. REQUEST CLASS ATTEST TO PROPER OPERATION OF FRESH WATER COOLING SYSTEM FOR ESSENTIAL MACHINERY. SOLAS 74/78(2004) IX/3 & ISM Code 9.1 SOLAS 74/78(2004) II-1/26.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2007
Resolution: Vessel removed temporary JW aeration system and cond of class imposed for system modification not later than 14 Nov 07, see attached documenation.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 10 October 2007
Resolved
1030- VSL STEERING GEAR POWER FAILURE ALARM DO NOT ACTIVATE UPON LOSS OF POWER TO THE STEERING GEAR MOTORS (BOTH PORT AND STBD MOTORS). BRIDGE WATCH WOULD RECEIVE NO NOTIFICATION IN THE EVENT OF POWER LOSS TO STEERING MOTORS. CLASS TO ATTEST TO PROPER OPERATION OF ALARMS.SOLAS 74/78(2004) II-1/29.5.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2007
Resolution: repaired to the satisfaction of class. see attached class report.
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 10 October 2007
Resolved
VSL OPERATING AUX BOILER IN MANUAL MODE NOT IN AUTOMATED MODE. CONDITION OF BOILER SUGGEST THAT OPERATION OF BOILER IN AUTOMATED MODE MAY NOT BE POSSIBLE OR APPROPRIATE. NUMEROUS DEAD END WIRES, DISCONNECTED GROUNDING STRAPS, OPEN PIPING CONNECTIONS, EXPOSED PROBED WERE OBSERVED. CLASS TO ATTEST TO PROPER OPERATION OF BOILER AND BOILER AUTOMATION SYSTEM. SOLAS 74/78(2004) I/II
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2007
Resolution: boiler tech attended vessel and repaired boiler to proper operation status including boiler automation system. cond of class imposed for attitional repairs to be conducted NLT 14 Nov 07 see attached documentation.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 10 October 2007
Resolved
0715 - FIRE DETECTION SYSTEM INTERFACE PANEL DISPLAYS "FAULT DETECTION" AND "ABNORMAL CONDITION" INDICATOR LIGHTS. ABILITY OF DETECTION SYSTEM TO ACCURATELY DETECT AND ALARM IN THE EVENT OF AN ACTUAL FIRE IS UNKNOWN. CLASS TO ATTEST TO CONDITION AND OPERABILITY OF FIRE DETECTION SYSTEM VARIFYING PROPER FIRE PROTECTION IN ALL SPACES SECURED. SOLAS 74/78(2004) I/II
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2007
Resolution: alarms system serviced and repaired, with class approval. see attached documentation.
Lifesaving › Lifeboat Equipment › Radio (fixed two-way VHF radio-telephone)
Issued 10 October 2007
Resolved
0673- ONE LIFEBOAT RADIO BATTERY IS EXPIRED, BATTERY EXPIRED AUG 07. VSL REQUESTED 3 NEW BATTERIES AND ONLY GOT 2. RO TO ATTEST TO PROPER IMPLEMENTATION OF ISM CODE RELATED COMMUNICATION AND CORRECTION ON NON CONFORMITIES RPTED TO COMPANY BY VSL. SOLAS 74/78(2004) IX/3 & ISM Code 9.2 SOLAS 74/78(2004) III/6.2.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2007
Resolution: installed on board as required. as noted in class report.
Stability › Watertight Integrity › General
Issued 10 October 2007
Resolved
1240- VSL STERN RAMPHOLED IN TWO PLACES. APPROX 1.5" HOLES IN WAY OF WALKWAY STANTION FITTINGS ON EACH PORT AND STBD SIDE OF RAMP (HINGED END). RAMP NOT WATER TIGHT AS REQUIRED CLASS TO ATTEST TO PROPER WATER TIGHT INTEGRITY OF STERN RAMP (IMMENSURATE WITH SURROUNDING SHELL PLATE) ICLL Annex I/21(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2007
Resolution: vessel welded to repair.
Construction/Loadline › Hull › Weld
Issued 10 October 2007
Resolved
RUDDER SKECT CRACKED ON STBD SIDE 32" LENGTH AND PORT SIDE 40" LENGTH. CLASS TO ATTEST CONDITION OF RUDDER SKECT. SOLAS 74/78(2004) I/II
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2007
Resolution: condition of class imposed. see attached documenation.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 10 October 2007
Resolved
1721- VSL REGISTERING OILY BILGE TANK HIGH ALARM. LRB SHOWS TANK TO HOLD 13.1M3. TANK CAPACITY IS 84M3. VSL TO DEMONSTRATE PLAN FOR HANDLING OILY WASTES. MARPOL Annex I/15
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2007
Resolution: vessel offloaded oily waste. see attached reciepts.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 October 2007
Resolved
1499- VSL ENGINE ROOM HAS SEVERAL WIRING CONNECTIONS WITH WASTED INSULATION. IN MOST CASES TEMP REPAIRS WITH ELECTRICAL TAPE HAVE BEEN MADE. SOLAS 74/78(2004) II-1/3-1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2007
Resolution: class attested to proper repair. see attached documentation.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 10 October 2007
Resolved
1270- GASKETS WASTED IN FOLLOWING LOCATIONS TO POINT WHERE WEATHERTIGHT INTERGRITY IS NOT MET. CLASS TO ATTEST TO PROPER WEATHERTIGHT INTEGRITY. ICLL Annex I/18
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2007
Resolution: condition of class imposed. see attached documentation.
Fire Fighting › Nozzles › Location
Issued 10 October 2007
Resolved
0720- FIRESTATION PORT SIDE AFT OF MID SHIP ON DK 12 MISSING FIRENOZZLE. SOLAS 74/78(2004) II-2/4.2.1.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2007
Resolution: nozzle installed to the satisfaction of class. see attached.
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 10 October 2007
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2007
Resolution: vessel was required to provide Sector Baltimore a LOU for liability regarding pending enforcement case for failure to report hazardous condition. enforcement case pends.
Construction/Loadline › Structures › Door
Issued 10 October 2007
Resolved
Vessel has three doors cracked at each door frame corner, largest is approx 10". Condition had exisisted previously and repairs have subsequently failed. Class to address. Same with crack in cargo deck 7 immediately fwd of moveable ramp/cargo dk. SOLAS 74/78(2004) II-1/3-1 SOLAS 74/78(2004) IX/3 & ISM Code 9.1
Action required: 705 - Other - as specified
Due 10 November 2007
Resolved 14 October 2007
Resolution: condition of class imposed for correction NLT 14 Nov 07.
Documentation › Markings/Placards › Lifejacket Placard
Issued 10 October 2007
Resolved
Three life bouys have worn IMO plackards no longer effective for intended puporse. Port and stbd gangway as well as on bow. Class to address. SOLAS 74/78(2004) III/20.3
Action required: 705 - Other - as specified
Due 10 November 2007
Resolved 14 October 2007
Resolution: renewed to the satisfaction of class.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 10 October 2007
Resolved
connection between treatment tank top and vacuum line wasted. fitting gives under hand pressure. existing temp repairs appear to have failed. class to attest to structural integrity of tank top and vacuum connection. SOLAS 74/78(2004) II-1/3-1
Action required: 705 - Other - as specified
Due 10 November 2007
Resolved 14 October 2007
Resolution: condition of class imposed.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 10 October 2007
Resolved
vessel sewage treatment plant is not marked as required by 33 CFR 159.55. Install marking plate in accordance with manf.specifications. Coast Guard to verify. 33CFR 159.55
Action required: 705 - Other - as specified
Due 10 November 2007
Resolved 14 October 2007
Resolution: vessel installed required marking.
Communications › Internal Communications System › Sound-powered Telephone
Issued 10 October 2007
Resolved
vessel electric phone between steering gear room and bridge ineffective during PSC exam. sound powered phone located adjacent is of diminished capacity. ability of vessel to effectively communicate navigation commands in emergency with installed communications systems is diminished. class to attest to proper operation. SOLAS 74/78(2004) II/1
Action required: 705 - Other - as specified
Due 10 November 2007
Resolved 14 October 2007
Resolution: condition of class imposed. see attached documentation. 14 Nov 07
Construction/Loadline › Structures › Superstructure
Issued 10 October 2007
Resolved
window located on aft of bridge, stbd side is shattered and held together by transparent adhesive. window is difficult to see through and weather tight integrity is in question. class to attest to integrity / repair. SOLAS 74/78(2004) II-1/3-1
Action required: 705 - Other - as specified
Due 10 November 2007
Resolved 14 October 2007
Resolution: condition of class imposed for window replacement. 14 nov 07, see attached.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 10 October 2007
Resolved
liferaft servicing certs reference IMO number 9327384 and call sign C4KC2. vessels IMO number is 9075709 and call sign is C6NA4. class to attest to validity of certificates. SOLAS 74/78(2004) III/8.1 SOLAS 74/78(2004) X/3 & ISM Code 11.2
Action required: 705 - Other - as specified
Due 10 November 2007
Resolved 14 October 2007
Resolution: life rafts serviced locally and one new liferaft installed on board to the satisfaction of class. see attached documentation.
Fire Fighting › Fire Hydrants › Condition
Issued 10 October 2007
Resolved
three fire plugs found to be blowing by creating hazardous condition in the event of plug cover/cap removal and potential flooding hazard. plus are located in E/R lower level fwd, port; mid engine room, stbd; and cargo dk 3 fwd, stbd. SOLAS 74/78(2004) I/II
Action required: 705 - Other - as specified
Due 10 November 2007
Resolved 14 October 2007
Resolution: ships crew performed maintenance to the satisfaction of class. see attached documentation.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device Recorder
Issued 21 May 2004
Resolved
Repair/replace echo-depth sounding device recorder at next port IAW technician's report.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 May 2004
Resolved 26 May 2004
Resolution: Echo Sounder paper feed motor and control PCB was renewed by service company Radio Holland USA in Houston, Texas. Unit is now working properly. Unit is now marking properly on paper and reading correct depth.
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 21 May 2004
Resolved
Repair/replace faulty gyro compass repeater. Provide Master's statement attesting to repairs/replacement to COTP/[name withheld].
Due 21 June 2004
Resolved 26 May 2004
Resolution: Gyro Compass Port Bridge Wing Repeater was renewed by service company Sperry Marine in Houston, Texas. Unit is now working properly and synchronized with other repeater.
Engineering
Issued 30 October 2001
Resolved
VSL LOSS PROPULSION ENG INBOUND, AIR CONTROL SYSTEM FAILURE. VSL MADE PERM REPAIRS. RECIEVED CLASS REPORTS OF PERM REPAIRS
Condition: Unknown
Due 31 October 2001
Resolved 31 October 2001