MAURY USCG vessel records Sign in
← All vessels

SEA JOY

SEA JOY is a 1984 freight ship. The Coast Guard has recorded 5 inspections since 2004, most recently in November 2005, along with 6 deficiencies — 2 with no resolution recorded —.

Records from 2004 to 2005. Most recent: inspection, 17 November 2005.

Built
1984
Last inspected
17 November 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8403648 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
419394
Flag
SOUTH KOREA
—
Maury page id
psix-419394

Inspections, by type

…with no type recorded1
Years with a record 2 calendar years (2004–2005)
The 5 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it2052 - Simplified, Net Ton
2477 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 5

17 November 2005 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2536236
10 December 2004 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2270350
3 September 2004 Deficiency Check · ISPS II Exam · Ballast Water Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2185192
9 June 2004 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2093054
17 March 2004 MARPOL Annex V Examination · Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2025932

Deficiency record · 6

Construction/Loadline › Structures › Door
Issued 17 November 2005 No resolution recorded
Weathertight integrity on 01 and 02 deck aft doors compromised. Make doors on 01 and 02 deck aft weathertight.
Action required: 15 - Rectify deficiencies by next port
Fire Fighting › Fire Main › Condition
Issued 17 November 2005 No resolution recorded
Make permanent repairs to pinhole leak in firemain piping on maindeck stern. SOLAS 74 II-2 / 15
Action required: 15 - Rectify deficiencies by next port
Documentation › Safety Management System › Response Measures Documentation
Issued 9 June 2004 Resolved
Provide documentation from KRS Class Society verifying that items 1,2, and 3 from Activity #2025932 were repaired to class satisfaction.
Action required: 705 - Other - as specified
Due 1 August 2004
Resolved 3 September 2004
Fire Fighting › Fire Pumps
Issued 17 March 2004 Resolved
Fire/General Service Pump casing wasted w/cement box patch in place. Repair to the satisfaction of Class LEGACY COMPONENT DESC: Casing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 9 June 2004
Deck/Cargo › Cargo Transfer (solid)
Issued 17 March 2004 Resolved
Cagro Sheaves wasted. Repair to the satisfaction of Class LEGACY COMPONENT DESC: Sheaves
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 9 June 2004
Construction/Loadline › Structures
Issued 17 March 2004 Resolved
Watertight Doors edges wasted IWO door gasket. Repair to the satisfaction of Class LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 9 June 2004

Ownership record