Records from 1996 to 2000. Most recent: inspection, 22 May 2000.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Electrical
Issued 22 May 2000
Resolved
CLASS TO VERIFY INTRINSICALLY SAFE LIGHT FIXTURES IN FORWARD PAINT LOCKER PRIOR TO 22 JUN 00.
Condition: Unknown
Due 3 August 2000
Resolved 3 August 2000
Electrical
Issued 22 May 2000
Resolved
PLACE NON CONDUCTIVE MATTING IN FRONT OF ALL ELECTRICAL PANELS THROUGHOUT THE VESSEL PRIOR TO 22 JUN 00.
Condition: Unknown
Due 3 August 2000
Resolved 3 August 2000
Lifesaving
Issued 22 May 2000
Resolved
REPAINT LOADLINE AT NEXT DRY DOCK.
Condition: Unknown
Due 3 August 2000
Resolved 3 August 2000
Fire Fighting
Issued 22 May 2000
Resolved
PRIOR TO DEPARTURE DEMONSTRATE A SATISFACTORY FIRE DRILL.
Condition: Unknown
Due 22 May 2000
Resolved 26 May 2000
Fire Fighting
Issued 22 May 2000
Resolved
REPLACE INTERNATIONAL SHORE CONNECTION PRIOR TO 22 JUN 00.
Condition: Unknown
Due 24 May 2000
Resolved 30 May 2000
Fire Fighting
Issued 22 May 2000
Resolved
UNTIE ALL STAR TOWER DOORS TO PERMIT PROPER CLOSURE PRIOR TO DEPARTURE.
Condition: Unknown
Due 24 May 2000
Resolved 30 May 2000
Lifesaving
Issued 22 May 2000
Resolved
REPLACE BRIDGEWING LIFE BUOYS WITH BUOYS 4 KGS OR HEAVIER PRIOR TO 22 JUN 00.
Condition: Unknown
Due 3 August 2000
Resolved 3 August 2000
Construction/Loadline
Issued 22 May 2000
Resolved
CLASS TO GAUGE AFT MOORING DECK FOR EXCESSIVE WASTAGE. PROVIDE REPORT OF SATISFACTORY OR UNSATISFACTORY CONDITION PRIOR TO 22 JUN 00.
Condition: Unknown
Due 3 August 2000
Resolved 3 August 2000
Lifesaving
Issued 22 May 2000
Resolved
SEPARATE OXYGEN AND ACETLYNE BOTTLES OUTSIDE LAUNDRY PRIOR TO DEPARTURE.
Condition: Unknown
Due 24 May 2000
Resolved 30 May 2000
Construction/Loadline
Issued 22 May 2000
Resolved
CLASS TO VERIFY REPAIRS / WELDING IN FOREPEAK PRIOR TO 22 JUN 00.
Condition: Unknown
Due 3 August 2000
Resolved 3 August 2000
Accommodation/Occupational Safety
Issued 22 May 2000
Resolved
REPAIR / REPLACE STEPS TO BOAT DECK LEADING FROM AFT MOORING DECK AND STEPSTO BRIDGE PRIOR TO 22 JUN 00.
Condition: Unknown
Due 3 August 2000
Resolved 3 August 2000
Construction/Loadline
Issued 23 June 1998
Resolved
Some fuel oil tank vents were covered with the improper type of mesh to prevent containment of a fire. The size of the mesh was 30x30.
Condition: Unknown
Due 1 July 1998
Resolved 25 August 1998
Construction/Loadline
Issued 23 June 1998
Resolved
Significant wastage of main deck area consisting of: Severe pitting over the entire main deck, two 4 inch holes and a 3 foot fracture located amidship forward of the first hold, failed temporary repairs on the fantailresulting in further wastage on the main deck.
Condition: Unknown
Due 1 July 1998
Resolved 25 August 1998
Fire Fighting
Issued 30 January 1996
Resolved
PROVIDE ONBOARD FIRE CONTROL PLANS THAT SHOW CLEARLY THE PARTICULARS OF THEFIRE DETECTION AND FIRE ALARM SYSTEMS, THE FIXED CO2 INSTALLATION, THE FIREEXTINGUISHING APPLIANCES, MEANS OF ACCESS TO DIFFERENT COMPARTMENTS, DECKS,ETC. AND THE VENTILATION SYSTEM. SOLAS 74 (AMENDED) II-2/20
Condition: Unknown
Due 6 February 1996
Resolved 8 February 1996
Engineering
Issued 30 January 1996
Resolved
PROVIDE AN ALARM TO THE 15 PPM OILY WATER SEPERATOR AS REQUIRED BY THE SHIPS IOPP CERTIFICATE AND 33 CFR 155.370
Condition: Unknown
Due 6 February 1996
Resolved 8 February 1996
Electrical
Issued 30 January 1996
Resolved
PROVE TO THE SATISFACTION OF THE ATTENDING US COAST GUARD MARINE INSPECTOR SATISFACTORY OPERATION OF THE SHIPS EMERGENCY LIGHTS.
Condition: Unknown
Due 6 February 1996
Resolved 8 February 1996
Fire Fighting
Issued 30 January 1996
Resolved
PROVIDE ONBOARD VESSEL INSTRUCTIONS FOR MAINTENANCE AND OPERATION OF ALL INSTALLATIONS/EQUIPMENT FOR FIGHTING AND CONTAINMENT OF FIRE. SOLAS 74 (AMENDED) II-2/20
Condition: Unknown
Due 15 April 1996
Resolved 15 April 1996
Fire Fighting
Issued 30 January 1996
Resolved
PROVIDE EVIDENCE THAT ALL PROTABLE FIRE EXTINGUISHERS HAVE BEEN SERVICED AND ARE AVAILABLE FOR IMMEDIATE USE. SOLAS 74 (AMENDED) II-2/21_x001C_
Condition: Unknown
Due 6 February 1996
Resolved 8 February 1996
Lifesaving
Issued 30 January 1996
Resolved
REMOVE OIL AND OIL RESIDUE FROM THE OIL SEPERATOR ROOM.
Condition: Unknown
Due 6 February 1996
Resolved 8 February 1996
Lifesaving
Issued 30 January 1996
Resolved
REMOVE PAINT STOWED IN FORWARD BOS'N HOLD. SOLAS 74 (AMENDED) II-2/18.7
Condition: Unknown
Due 6 February 1996
Resolved 8 February 1996
Fire Fighting
Issued 30 January 1996
Resolved
REPLACE MISSING SMOKE DETECTOR IN FORWARD BOS'N HOLD. SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 6 February 1996
Resolved 8 February 1996
Fire Fighting
Issued 30 January 1996
Resolved
SECURELY MOUNT SMOKE DETECTOR LOCATED IN CARPENTERS SHOP.
Condition: Unknown
Due 6 February 1996
Resolved 8 February 1996
Accommodation/Occupational Safety
Issued 30 January 1996
Resolved
RENEW AS ORIGINAL DETERIORATED PIPE TO TYPE III MSD HOLDING TANK.
Condition: Unknown
Due 6 February 1996
Resolved 8 February 1996
Lifesaving
Issued 30 January 1996
Resolved
PROVIDE A SUITABLE STUFFING TUBE FOR THE BULKHEAD PENETRATION LOCATED PORTSIDE ON THE OFFICERS DECK ABOVE THE CREW'S ACCESS.
Condition: Unknown
Due 6 February 1996
Resolved 8 February 1996
Engineering
Issued 30 January 1996
Resolved
PROVIDE SECURING DOGS TO VENTILATION CLOSURE LOCATED ON THE "B" DECK FORWARD ON THE AFT PILOT HOUSE. SOLAS 60 II/47 (a)
Condition: Unknown
Due 6 February 1996
Resolved 8 February 1996
Electrical
Issued 30 January 1996
Resolved
RENEW MISSING EMERGENCY LIGHT LOCATED IN THE EMERGENCY EXIT FOR #5 CARGO HOLD.
Condition: Unknown
Due 6 February 1996
Resolved 8 February 1996
Fire Fighting
Issued 30 January 1996
Resolved
SECURE SMOKE DETECTOR LOCATED IN THE EMERGENCY GENERATOR ROOM._x001C_ SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 6 February 1996
Resolved 8 February 1996
Fire Fighting
Issued 30 January 1996
Resolved
RENEW AS ORIGINAL DETERIORATED FIRE MAIN PIPING TO FIRE HYDRANT LOCATED STARBOARD SIDE ON THE MAIN DECK IN WAY OF #2 DECK HOUSE. SOLAS 74 (AMENDEDII-2/21
Condition: Unknown
Due 6 February 1996
Resolved 8 February 1996
Fire Fighting
Issued 30 January 1996
Resolved
RENEW AS ORIGINAL DETERIORATED FIRE MAIN PIPING LOCATED STARBOARD SIDE FORWARD ON THE MAIN DECK. SOLAS 74 (AMENDED)II-2/21
Condition: Unknown
Due 6 February 1996
Resolved 8 February 1996
Engineering
Issued 30 January 1996
Resolved
RENEW/REPAIR IN-OPERABLE VENTILATION CLOSURES LOCATED ON TO OF THE #2 DECK HOUSE. SOLAS 60 II/47(a)
Condition: Unknown
Due 6 February 1996
Resolved 8 February 1996
Lifesaving
Issued 30 January 1996
Resolved
REMOVE SPILLED PAINT FROM THE FORWARD PAINT LOCKER .
Condition: Unknown
Due 6 February 1996
Resolved 8 February 1996
Electrical
Issued 30 January 1996
Resolved
RENEW/REPAIR BROKEN LIGHTING FIXTURE LOCATED PORTSIDE ON THE OFFICERS DECK.SOLAS 60 II/27 (a)(vi)
Condition: Unknown
Due 6 February 1996
Resolved 8 February 1996
Lifesaving
Issued 30 January 1996
Resolved
PROVIDE WEAK LINKS FOR LIFERAFTS SECURED IN A FLOAT FREE ARRANGEMENT THAT WILL NOT BE BROKEN BY THE FORCE REQUIRED TO PULL THE PAINTER FROM THE LIFERAFT CONTAINER. SOLAS 74 (AMENDED) III 38/6.2.1
Condition: Unknown
Due 6 February 1996
Resolved 8 February 1996
Lifesaving
Issued 30 January 1996
Resolved
RENEW RETRO-REFLECTIVE MATERIAL TO PORT AND STARBOARD LIFEBOAT. LIFEBOATS SHALL BE FITTED WITH RETRO-REFLECTIVE MATERIAL IN ACCORDANCE WITH SOLAS 74 (AMENDED) III/30.2.7 AND IMO RESOLUTION A.658(16)
Condition: Unknown
Due 6 February 1996
Resolved 8 February 1996
Lifesaving
Issued 30 January 1996
Resolved
PROVIDE ONBOARD A MEANS FOR BRINGING THE LIFEBOATS AGAINST THE SHIP'S SIDE AND HOLDING THEM SO THAT PERSONS MAY BE SAFELY EMBARKED. _x001C_ SOLAS 60 III/36 (l)
Condition: Unknown
Due 6 February 1996
Resolved 8 February 1996
Lifesaving
Issued 30 January 1996
Resolved
PROVIDE ONBOARD A MEANS FOR ILLUMINATING THE LIFEBOATS AND THEIR LAUNCHING GEAR DURING PREPARATION FOR AND THE PROCESS OF LAUNCHING, AND ALSO FOR ILLUMINATING THE WATER INTO WHICH THE LIFEBOATS ARE LAUNCHED._x001C_ SOLAS 60 III/19(a)(ii)
Condition: Unknown
Due 6 February 1996
Resolved 8 February 1996
Lifesaving
Issued 30 January 1996
Resolved
PROVIDE ONBOARD, SUFFICIENT LADDERS TO FACILITATE EMBARKATION INTO THE LIFERAFTS WHEN WATERBORNE. SOLAS 60 III/19(b)(i)
Condition: Unknown
Due 6 February 1996
Resolved 8 February 1996
Lifesaving
Issued 30 January 1996
Resolved
PROVIDE ONBOARD, AT LEAST TWO RING LIFEBOUYS EQUIPPED WITH A SELF-IGNITING LIGHT AND SMOKE CAPABLE OF QUICK RELEASE FROM THE NAVIGATING BRIDGE. _x001C_ SOLAS 60 III/21(g)
Condition: Unknown
Due 6 February 1996
Resolved 8 February 1996
Lifesaving
Issued 30 January 1996
Resolved
RENEW ALL DEFECTIVE RING LIFEBOUYS. PROVIDE TWELVE RING LIFEBOUYS ON STATION IN ACCOARDANCE WITH THE SHIPS SAFETY EQUIPMENT CERTIFICATE IN SERVICEABLE CONDITION AND AVAILABLE FOR IMMEDIATE USE. SOLAS 74 (AMENDED) III/19.2
Condition: Unknown
Due 6 February 1996
Resolved 8 February 1996
Fire Fighting
Issued 30 January 1996
Resolved
RENEW ALL DEFECTIVE FIRE HOSES THROUGHOUT VESSEL NOTED OVER 90% OF THOSE CHECKED WERE HOLED OR INCOMPATIBLE WITH HYDRANTS. ALL FIRE HOSES THROUGHOUT THE VESSEL SHALL BE RENEWED AND/OR PRESSURE TESTED IN THE PRESENCE OF THE US COAST GUARD. SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 6 February 1996
Resolved 8 February 1996
Lifesaving
Issued 30 January 1996
Resolved
REMOVE BATTERIES STOWED ON TOP OF PILOT HOUSE. SOLAS 60 II/27(a)(viii)
Condition: Unknown
Due 6 February 1996
Resolved 8 February 1996
Lifesaving
Issued 30 January 1996
Resolved
PROVIDE AND POST A MUSTER LIST AND EMERGENCY INSTRUCTIONS THAT COMPLY WITH THE REQUIREMENTS OF SOLAS 74 (AMENDED) III/8 AND ARE IN A LANGUAGE EASILY UNDERSTOOD BY THE CREW.
Condition: Unknown
Due 6 February 1996
Resolved 8 February 1996
Fire Fighting
Issued 30 January 1996
Resolved
FROVE TO THE SATISFACTION OF THE ATTENDING US COAST GUARD MARINE INSPECTOR SATISFACTORY OPERATION OF THE SHIPS SMOKE DETECTION SYSTEM. SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 6 February 1996
Resolved 8 February 1996
Lifesaving
Issued 30 January 1996
Resolved
PROVIDE EQUIPMENT FOR PORT AND STARBOARD LIFEBOATS AS REQUIRED BY SOLAS 60 III/11.
Condition: Unknown
Due 6 February 1996
Resolved 8 February 1996
Lifesaving
Issued 30 January 1996
Resolved
PROVID ONBOARD VESSEL TRAINING MANUAL FOR LIFESAVING APPLIANCES. SOLAS 74 (AMENDED) III/18.2/51
Condition: Unknown
Due 6 February 1996
Resolved 8 February 1996
Lifesaving
Issued 30 January 1996
Resolved
PROVIDE ONBOARD VESSEL, INSTRUCTIONS FOR ONBOARD MAINTENANCE OF LIFESAVING APPLIANCES. SOLAS 74 (AMENDED) III/19.3/52
Condition: Unknown
Due 15 April 1996
Resolved 15 April 1996
Lifesaving
Issued 30 January 1996
Resolved
POSTERS OR SIGNS SHALL BE PROVIDED ON OR IN THE VICINITY OF SURVIVAL CRAFT AND THEIR LAUNCHING CONTROLS. SOLAS 74 (AMENDED)III/9
Condition: Unknown
Due 6 February 1996
Resolved 8 February 1996