MAURY USCG vessel records Sign in
← All vessels

CHYORNOE MORE

CHYORNOE MORE is a 1976 freight ship. The Coast Guard has recorded 6 inspections since 1995, most recently in December 1998, along with 40 deficiencies and 1 operational control.

Records from 1995 to 1998. Most recent: inspection, 1 December 1998.

Built
1976
Last inspected
1 December 1998
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7646566 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
419440
Flag
UKRAINE
—
Maury page id
psix-419440

Inspections, by type

…with no type recorded6
Years with a record 3 calendar years (1995–1998)
The 6 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it4863 - Convention (Subpart B), Net Ton
13496 - Convention (Subpart B), Gross Ton
11570 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 6

1 December 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 423044
7 November 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 422589
4 November 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 396839
26 June 1996 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 392748
10 April 1996 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 389751
29 November 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 385181

Deficiency record · 40

Deck/Cargo
Issued 7 November 1998 Resolved
PRIOR TO NEXT US PORT REPLACE FUEL OIL CONTAINMENT PLUGS WITH PROPER MECHANICAL PLUGS.
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Construction/Loadline
Issued 7 November 1998 Resolved
PRIOR TO NEXT US PORT REPAINT LOADLINE MARKS.
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Electrical
Issued 7 November 1998 Resolved
PRIOR TO NEXT US PORT REPAIR BROKEN LIGHT COVERS IN ENGINROOM AND COMPRESSOR ROOM.
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Fire Fighting
Issued 7 November 1998 Resolved
PRIOR TO NEXT US PORT GREASE ALL FIRE NOZZLES THAT ARE DIFFICULT TO OPERATE.
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Accommodation/Occupational Safety
Issued 7 November 1998 Resolved
PRIOR TO NEXT US PORT REPLACE SUPPORT BRACKETSFOR LADDER PLATFORMS TO EMERGENCY FIREPUMP ROOM.
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Fire Fighting
Issued 7 November 1998 Resolved
PRIOR TO NEXT US PORT LABEL INTERNATIONAL SHORE CONNECTION.
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Engineering
Issued 26 June 1996 Resolved
Small discharge containment coaming rusted through near port bow. Repair as required by 33 CFR 155.320(a).
Condition: Unknown
Due 5 November 1996
Resolved 5 November 1996
Fire Fighting
Issued 29 November 1995 Resolved
RENEW AS ORIGINAL FIRE SUPPRESSION SYSTEM TO FWD PAINT LOCKER. PROVIDE SERVICING DOCUMENT TO THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 7 December 1995
Resolved 8 December 1995
Construction/Loadline
Issued 29 November 1995 Resolved
RENEW AS ORIGINAL REMOTE OPERATING RODS FOR BALLASTING VALVES LOCATED IN THE EMERGENCY FIRE PUMP ROOM.
Condition: Unknown
Due 7 December 1995
Resolved 8 December 1995
Fire Fighting
Issued 29 November 1995 Resolved
RENEW/REPLACE SEMI-PORTABLE FOAM FIRE EXTINGUISHERS IN ENGINE ROOM. SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 7 December 1995
Resolved 8 December 1995
Engineering
Issued 29 November 1995 Resolved
RENEW AS ORIGINAL FRESH WATER SUPPLY PIPING LOCATED STBD SIDE ENGINE ROOM OUTBOARD BOILERS.
Condition: Unknown
Due 7 December 1995
Resolved 8 December 1995
Engineering
Issued 29 November 1995 Resolved
RENEW AS ORIGINAL REMOTE/AUTOMATIC OPERATING AIR SUPPLY LINE TO ISOLATION VALVE FOR ENGINE COOLANT SUPPLY.
Condition: Unknown
Due 7 December 1995
Resolved 8 December 1995
Lifesaving
Issued 29 November 1995 Resolved
RENEW RETRO-REFLECTIVE MATERIAL TO PORT AND STBD LIFEBOATS. SOLAS 74 AMENDED III/30.2.7
Condition: Unknown
Due 7 December 1995
Resolved 8 December 1995
Construction/Loadline
Issued 29 November 1995 Resolved
PROVIDE ONBOARD "DISCHARGE OFM OIL PROHIBITED" PLACARD PRINTED IN THE LANGUAGE OR LANGUAGES UNDERSTOOD BY THE CREW. 33 C.F.R. 155.450
Condition: Unknown
Due 7 December 1995
Resolved 8 December 1995
Lifesaving
Issued 29 November 1995 Resolved
PROVIDE ONBOARD MUSTER LIST AND EMERGENCY INSTRUCTIONS IN THE LANGUAGE OR LANGUAGES UNDERSTOOD BY THE CREW. SOLAS 74 AMENDED III/8
Condition: Unknown
Due 7 December 1995
Resolved 8 December 1995
Engineering
Issued 29 November 1995 Resolved
RENEW AS ORIGINAL SALT WATER COOLING SUPPLY LINE TO MAIN SHAFT BEARING.
Condition: Unknown
Due 7 December 1995
Resolved 8 December 1995
Engineering
Issued 29 November 1995 Resolved
RENEW AS ORIGINAL COOLANT SUPPLY PIPING TO #3 AIR COMPRESSOR.
Condition: Unknown
Due 7 December 1995
Resolved 8 December 1995
Lifesaving
Issued 29 November 1995 Resolved
PROVIDE ONBOARD 57 LIFEJACKETS AS REQUIRED BY VESSELS SAFETY EQUIPMENT CERTIFICATE. SOLAS 74 AMMENDED III/19.2
Condition: Unknown
Due 7 December 1995
Resolved 8 December 1995
Navigation
Issued 29 November 1995 Resolved
PROVE OPERATION OF EMERGENCY STEERING WITH TRICK WHEEL FROM STEERING GEAR COMPARTMENT.
Condition: Unknown
Due 7 December 1995
Resolved 8 December 1995
Fire Fighting
Issued 29 November 1995 Resolved
PROVIDE ONBOARD AN UPDATED FIRE CONTROL PLAN. SOLAS 74 AMENDED II-2/20
Condition: Unknown
Due 7 December 1995
Resolved 8 December 1995
Lifesaving
Issued 29 November 1995 Resolved
PROVIDE FOR REVIEW TRAINING MANUAL FOR LIFESAVING APPLIANCES. SOLAS 74 AMENDED III/18.2/51
Condition: Unknown
Due 15 April 1996
Resolved 15 April 1996
Lifesaving
Issued 29 November 1995 Resolved
PROVIDE FOR REVIEW INSTRUCTIONS FOR ONBOARD MAINTENANCE OF LIFESAVING APPLIANCES. SOLAS 74 AMENDED III/19.3/52
Condition: Unknown
Due 15 April 1996
Resolved 15 April 1996
Lifesaving
Issued 29 November 1995 Resolved
POSTERS OR SIGNS SHALL BE PROVIDED ON OR IN THE VICINITY OF SURVIVAL CRAFT AND THEIR LAUNCHING CONTROLS. SOLAS 74 AMENDED III/9
Condition: Unknown
Due 7 December 1995
Resolved 8 December 1995
Construction/Loadline
Issued 29 November 1995 Resolved
INSTALL VENTILATION CLOSURE TO EMERGENCY BATTERY ROOM VENT SYSTEM IN ACCORDANCE WITH SOLAS 60 II/47.
Condition: Unknown
Due 15 April 1996
Resolved 15 April 1996
Fire Fighting
Issued 29 November 1995 Resolved
RENEW/REPAIR ALL PORTABLE FIRE EXTINGUISHERS. PROVIDE SERVICING DOCUMENT TOU.S. COAST GUARD MARINE INSPECTOR IF EXTINGUISHERS ARE NOT RENEWED. SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 7 December 1995
Resolved 8 December 1995
Lifesaving
Issued 29 November 1995 Resolved
PROVIDE EVIDENCE THAT LIFEBOAT DAVIT FALLS HAVE BEEN END-FOR ENDED WITHIN 30 MONTHS AND/OR REPLACED WITHIN 5 YEARS. SOLAS 74 AMENDED III/19.4
Condition: Unknown
Due 7 December 1995
Resolved 8 December 1995
Fire Fighting
Issued 29 November 1995 Resolved
PROVIDE SERVICING REPORT FOR FIXED FIRE FIGHTING SYSTEM FOR ENG. SPACES. SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 7 December 1995
Resolved 8 December 1995
Lifesaving
Issued 29 November 1995 Resolved
PROVIDE EVIDENCE THAT LIFERAFT HYDRTO-STATIC RELEASES HAVE BEEN SERVICED WITHIN THE PAST 12 MONTHS. SOLAS 74 AMENDED III/19.9
Condition: Unknown
Due 7 December 1995
Resolved 8 December 1995
Lifesaving
Issued 29 November 1995 Resolved
PROVIDE LIFERING BUOYS TO BRIDGEWING THAT OPERATE IN THE QUICK RELEASE ARRAINGEMENT. SOLAS 74 AMENDED III/31.7
Condition: Unknown
Due 7 December 1995
Resolved 8 December 1995
Lifesaving
Issued 29 November 1995 Resolved
PROVIDE EVIDENCE OF LAST SERVICING OF 406mhz EPIRB HYDRO-STATIC RELEASE.
Condition: Unknown
Due 7 December 1995
Resolved 8 December 1995
Fire Fighting
Issued 29 November 1995 Resolved
REPLACE DETERIORATED FIREHOSES THROUGHOUT VESSEL. SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 7 December 1995
Resolved 8 December 1995
Fire Fighting
Issued 29 November 1995 Resolved
PROVIDE FOR REVIEW INSTRUCTIONS FOR MAINTENANCE AND OPERATION OF ALL INSTALLATIONS/EQUIPMENT FOR FIGHTING AND CONTAINMENT OF FIRE. SOLAS 74 AMENDED II-2/20
Condition: Unknown
Due 15 April 1996
Resolved 15 April 1996
Fire Fighting
Issued 29 November 1995 Resolved
RENEW/REPAIR NATURAL VENT DAMPERS IN WAY OF THE STBD LIFEBOAT TO ENSURE SMOOTH OPERATION AND PROPER SEAL.
Condition: Unknown
Due 7 December 1995
Resolved 8 December 1995
Lifesaving
Issued 29 November 1995 Resolved
PROVIDE ONBOARD WEAKLINKS TO EACH LIFERAFT STOWED IN A FLOAT-FREE ARRANGEMENT.
Condition: Unknown
Due 7 December 1995
Resolved 8 December 1995
Lifesaving
Issued 29 November 1995 Resolved
REPLACE DEFECTIVE LIFERING BUOYS THROUGHOUT VESSEL. SOLAS 74 AMENDED III/19.2
Condition: Unknown
Due 7 December 1995
Resolved 8 December 1995
Lifesaving
Issued 29 November 1995 Resolved
RENEW/REPLACE DEFECTIVE WATERLIGHTS TO RING LIFEBUOYS. SOLAS 74 AMENDED III/19.2
Condition: Unknown
Due 7 December 1995
Resolved 8 December 1995
Electrical
Issued 29 November 1995 Resolved
RENEW AS ORIGINAL COOLANT PIPING FROM RADIATOR TO EMERGENCY GENERATOR. (REMOVE SOFT PATCHES)
Condition: Unknown
Due 7 December 1995
Resolved 8 December 1995
Deck/Cargo
Issued 29 November 1995 Resolved
RENEW AS ORIGINAL REQUIRED CONTAINMENT FOR PORT AND STBD BUNKERING STATIONS. MARPOL 73/78 ANNEX I
Condition: Unknown
Due 7 December 1995
Resolved 8 December 1995
Fire Fighting
Issued 29 November 1995 Resolved
RENEW/REPAIR NATURAL VENT DAMPER PORT SIDE #2 MAST TO REFFER ROOM.
Condition: Unknown
Due 7 December 1995
Resolved 8 December 1995
Construction/Loadline
Issued 29 November 1995 Resolved
REMOVE ELECTRICAL CABLE FOULING NATURAL VENTILATION DOOR TO FORKLIFT ROOM. ENSURE VENT DAMPER PROVIDES AN AIRTIGHT SEAL AND PRODUCES SMOOTH OPERATION
Condition: Unknown
Due 7 December 1995
Resolved 8 December 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.